Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Three Paradigms of Lunar Regolith Evolution

Integration of diverse datasets on the Moon may render some paradigms of lunar science either better-defended or vulnerable. We will consider three paradigms commonly used for understanding the processes of lunar regolith evolution in light of new and accumulated data. Our premise is that all data-sets should converge to a single interpretation if a concept or model is to be accepted as a paradigm. If a convergence is lacking, the paradigm needs fresh scrutiny. SteadyState: Lunar regolith evolution is currently understood in terms of comminution, agglutination, and replenishment as described by McKay and coworkers). Briefly, the model envisages continued micrometeoritic bombardment to comminute exposed soil particles to finer sizes while continued agglutination consumes finer sizes to produce larger constructional particles. Eventually, a balance between these two opposing processes achieves a steady state; soils at steady state maintain their mean grain size (M(sub z)). Episodic higher-energy impacts excavate fresh coarse material from below the soil cover, disturb the steady state, and restart the process to achieve a new steady state. It follows that the thickness of the regolith at any site would control the frequency of replenishment; indeed, the thickness of the regolith at Apollo landing sites was predicted by McKay et al. from the average M(sub z) of local soils. However, replenishment may come also from disintegrating boulders and cobbles at the lunar surface, and rates of comminution and agglutination may depend on the properties of target material. Regression between M(sub z) and I(sub s)/Fe(sup 0) (a measure of maturity or total surface exposure) of Apollo soils at different sites shows the following relations and estimated M(sub z) at a high maturity of I(sub s)/Fe(sup 0)= 100. It is possible that Apollo 12 and 15 sites have the thickest regolith and the Apollo 16 site has the thinnest. It is also possible that Apollo 12 and 15 basalts are comminuted faster than Apollo 16 highland rocks and Apollo 14 and 17 soils are products of mixed parentage. If a soil becomes continually finer as it matures until agglutination catches up, and if comminution is differential-dependent on the physical properties of the constituents, then the composition of the bulk soil has to match the composition of some "fulcrum" grain size fraction, say X Grain size fractions >X and <X will complement each other; their mass balance is the bulk soil. It appears that the 10-20-micron size fraction may be the fulcrum. In general, trace-element chemistry and IR reflectance spectra of this size fraction are closest to that of the bulk soil, regardless of maturity that is surprising. Disaggregated products of regolith breccias may also show similar relationships. If the 10-20 gm is the fulcrum (i.e., X as above) for many soil properties (e.g., major element composition, FMR, solar-wind-implanted elements), then this may be the ultimate mean grain size of lunar soils at steady state. However, different properties of soils may find steady states at different grain size fractions. The steady state of solar-wind-implanted elements, on the other hand, will climb up the grain-size scale as agglutinates transfer surface-correlated components into volume correlated components until a saturation level is reached or the rates of replenishment and implantation become equal. The same will be the case with vapor-deposited reduced metals as they too are incorporated inside constructional particles. Properties that are directly affected by soil-maturation processes will thus have different pathways of achieving steady states. Maturity, i.e., cumulative surface exposure, of lunar soils is best quantified by the amount of nanophase superparamagnetic Fe(sup 0) (np-Fe(sup 0)) normalized to Fe content (=I(sub s)/Fe(sup 0). The majority consensus (paradigm?) for the production of np-Fe(sup 0) is associated with the production of agglutinates. Because large doses of solar-wind H are implanted in all lunar soils upon exposure, any melting (e.g., during agglutinate production) triggers a chemical reduction of Fe-bearing minerals resulting in np-Fe(sup 0) production. The quantity of np-Fe(sup 0) is thus dependent on melting events, (i.e., exposure), and limited by the Fe content of the soil. All freshly produced np-Fe(sup 0) resides in agglutinitic glass, as new TEM images show. Apparently, the correction procedure developed by Lucey et al. to estimate the Fe content of the lunar surface from IR-reflectance spectra depends on accepting the above. However, the process of producing np-Fe(sup 0) may be physical rather than chemical. All np-Fe(sup 0) could be deposits from a vapor produced by micrometeoritic impact on lunar soils. If metal-O bonds in target phases are broken, O being "most volatile" will escape leaving an O-deficient vapor to facilitate the production of np-Fe(sup 0). If so, the quantity of np-Fe(sup 0) is dependent on the vaporizing events, (i.e., exposure), and limited by the efficiency of breaking metal-O bonds and the escape of 0. To the extent that strengths of metal-O bonds are dependent on the local crystal field, production of np-Fe(sup 0) may be limited by the mineral composition of target soils and not by their total Fe content. According to this model, vapor-deposited np-Fe(sup 0) should be found at any retentive sites on lunar soil grains. Indeed, TEM images show np-Fe(sup 0) on plagioclase and ilmenite. Incorporation of such pre-irradiated np-Fe(sup 0)-bearing grains into agglutinates may account for eventual increased emplacement of np-Fe(sup 0) in agglutinates. Such a paradigm shift in understanding the origin of np-Fe(sup 0) will raise questions ranging from the unquestionable use of Is/FeO as the universal maturity parameter of lunar soils to global elemental maps of the Moon from remote-sensing data. Additional information is contained in the original.

Basu, A.↗

Managing Space Radiation Risks On Lunar and Mars Missions: Risk Assessment and Mitigation

Radiation-induced health risks are a primary concern for human exploration outside the Earth's magnetosphere, and require improved approaches to risk estimation and tools for mitigation including shielding and biological countermeasures. Solar proton events are the major concern for short-term lunar missions (<60 d), and for long-term missions (>60 d) such as Mars exploration, the exposures to the high energy and charge (HZE) ions that make-up the galactic cosmic rays are the major concern. Health risks from radiation exposure are chronic risks including carcinogenesis and degenerative tissue risks, central nervous system effects, and acute risk such as radiation sickness or early lethality. The current estimate is that a more than four-fold uncertainty exists in the projection of lifetime mortality risk from cosmic rays, which severely limits analysis of possible benefits of shielding or biological countermeasure designs. Uncertainties in risk projections are largely due to insufficient knowledge of HZE ion radiobiology, which has led NASA to develop a unique probabilistic approach to radiation protection. We review NASA's approach to radiation risk assessment including its impact on astronaut dose limits and application of the ALARA (As Low as Reasonably Achievable) principle. The recently opened NASA Space Radiation Laboratory (NSRL) provides the capability to simulate the cosmic rays in controlled ground-based experiments with biological and shielding models. We discuss how research at NSRL will lead to reductions in the uncertainties in risk projection models. In developing mission designs, the reduction of health risks and mission constraints including costs are competing concerns that need to be addressed through optimization procedures. Mitigating the risks from space radiation is a multi-factorial problem involving individual factors (age, gender, genetic makeup, and exposure history), operational factors (planetary destination, mission length, and period in the solar cycle), and shielding characteristics (materials, mass, and topology). We review optimization metrics for radiation protection including scenarios that integrate biophysics models of radiation risks, operational variables, and shielding design tools needed to assess exploration mission designs. We discuss the application of a crosscutting metric, based on probabilistic risk assessment, to lunar and Mars mission trade studies including the assessment of multi-factorial problems and the potential benefits of new radiation health research strategies or mitigation technologies.

Cucinotta, F. A.↗

Managing Space Radiation Risks on Lunar and Mars Missions: Risk Assessment and Mitigation

Radiation-induced health risks are a primary concern for human exploration outside the Earth's magnetosphere, and require improved approaches to risk estimation and tools for mitigation including shielding and biological countermeasures. Solar proton events are the major concern for short-term lunar missions (<60 d), and for long-term missions (>60 d) such as Mars exploration, the exposures to the high energy and charge (HZE) ions that make-up the galactic cosmic rays are the major concern. Health risks from radiation exposure are chronic risks including carcinogenesis and degenerative tissue risks, central nervous system effects, and acute risk such as radiation sickness or early lethality. The current estimate is that a more than four-fold uncertainty exists in the projection of lifetime mortality risk from cosmic rays, which severely limits analysis of possible benefits of shielding or biological countermeasure designs. Uncertainties in risk projections are largely due to insufficient knowledge of HZE ion radiobiology, which has led NASA to develop a unique probabilistic approach to radiation protection. We review NASA's approach to radiation risk assessment including its impact on astronaut dose limits and application of the ALARA (As Low as Reasonably Achievable) principle. The recently opened NASA Space Radiation Laboratory (NSRL) provides the capability to simulate the cosmic rays in controlled ground-based experiments with biological and shielding models. We discuss how research at NSRL will lead to reductions in the uncertainties in risk projection models. In developing mission designs, the reduction of health risks and mission constraints including costs are competing concerns that need to be addressed through optimization procedures. Mitigating the risks from space radiation is a multi-factorial problem involving individual factors (age, gender, genetic makeup, and exposure history), operational factors (planetary destination, mission length, and period in the solar cycle), and shielding characteristics (materials, mass, and topology). We review optimization metrics for radiation protection including scenarios that integrate biophysics models of radiation risks, operational variables, and shielding design tools needed to assess exploration mission designs. We discuss the application of a crosscutting metric, based on probabilistic risk assessment, to lunar and Mars mission trade studies including the assessment of multi-factorial problems and the potential benefits of new radiation health research strategies or mitigation technologies.

Cucinotta, F. A.↗

Managing Space Radiation Risks on Lunar and Mars Missions: Risk Assessment and Mitigation

Radiation-induced health risks are a primary concern for human exploration outside the Earth's magnetosphere, and require improved approaches to risk estimation and tools for mitigation including shielding and biological countermeasures. Solar proton events are the major concern for short-term lunar missions (<60 d), and for long-term missions (>60 d) such as Mars exploration, the exposures to the high energy and charge (HZE) ions that make-up the galactic cosmic rays are the major concern. Health risks from radiation exposure are chronic risks including carcinogenesis and degenerative tissue risks, central nervous system effects, and acute risk such as radiation sickness or early lethality. The current estimate is that a more than four-fold uncertainty exists in the projection of lifetime mortality risk from cosmic rays, which severely limits analysis of possible benefits of shielding or biological countermeasure designs. Uncertainties in risk projections are largely due to insufficient knowledge of HZE ion radiobiology, which has led NASA to develop a unique probabilistic approach to radiation protection. We review NASA's approach to radiation risk assessment including its impact on astronaut dose limits and application of the ALARA (As Low as Reasonably Achievable) principle. The recently opened NASA Space Radiation Laboratory (NSRL) provides the capability to simulate the cosmic rays in controlled ground-based experiments with biological and shielding models. We discuss how research at NSRL will lead to reductions in the uncertainties in risk projection models. In developing mission designs, the reduction of health risks and mission constraints including costs are competing concerns that need to be addressed through optimization procedures. Mitigating the risks from space radiation is a multi-factorial problem involving individual factors (age, gender, genetic makeup, and exposure history), operational factors (planetary destination, mission length, and period in the solar cycle), and shielding characteristics (materials, mass, and topology). We review optimization metrics for radiation protection including scenarios that integrate biophysics models of radiation risks, operational variables, and shielding design tools needed to assess exploration mission designs. We discuss the application of a crosscutting metric, based on probabilistic risk assessment, to lunar and Mars mission trade studies including the assessment of multi-factorial problems and the potential benefits of new radiation health research strategies or mitigation technologies.

Cucinotta, F. A.↗

Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

Non-NASA Center↗

Radiation Safety Issues in High Altitude Commercial Aircraft

The development of a global economy makes the outlook for high speed commercial intercontinental flight feasible, and the development of various configurations operating from 20 to 30 km have been proposed. In addition to the still unresolved issues relating to current commercial operations (12-16 km), the higher dose rates associated with the higher operating altitudes makes il imperative that the uncertainties in the atmospheric radiation environment and the associated health risks be re-examined. Atmospheric radiation associated with the galactic cosmic rays forms a background level which may, under some circumstances, exceed newly recommended allowable exposure limits proposed on the basis of recent evaluations of the A -bomb survivor data (due to increased risk coefficients). These larger risk coefficients, within the context of the methodology for estimating exposure limits, are resulting in exceedingly low estimated allowable exposure limits which may impact even present day flight operations and was the reason for the CEC workshop in Luxembourg (1990). At higher operating altitudes, solar particles events can produce exposures many orders of magnitude above background levels and pose significant health risks to the most sensitive individuals (such as during pregnancy). In this case the appropriate quality factors are undefined, and some evidence exists which indicates that the quality factor for stochastic effects is a substantial underestimate.

Wilson, John W.↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗

Preliminary estimates of galactic cosmic ray exposures for manned interplanetary missions

Preliminary estimates of radiation exposures resulting from galactic cosmic rays are presented for interplanetary missions. The calculations use the Naval Research Laboratory cosmic ray transport code. The heavy ion portion of the transport code can be used with any number of layers of target material, consisting of up to five different constituents per layer. The nucleonic portion of the transport code can be used with any number of layers of target material of arbitrary composition except hydrogen. Calculated galactic cosmic ray particle fluxes, doses, and dose equivalents behind various thicknesses of aluminum shielding are presented for solar maximum and solar minimum periods.

Wilson, John W.↗

Probability of Decompression Sickness and Venous Gas Emboli from 49 NASA Hypobaric Chamber Tests with Reference to Exploration Atmosphere

Introduction: Decompression sickness (DCS) is a complex biophysical event; it combines human perception of pain, for instance, and the presence of a gas phase in the tissues. Living tissues are complex and dynamic. Micronuclei and later bubbles may or may not form given what appears to be the same conditions. Even when bubbles grow, symptoms may or may not develop under what appears to be the same conditions. Therefore, at this time it is appropriate to consider DCS as a probabilistic rather than a deterministic event. Methods: Probabilistic models about hypobaric DCS and venous gas emboli (VGE) require a large amount of quality research data, a definition of decompression dose using physical and physiologic variables, and a flexible analytical approach that can quantify the association between each outcome and all covariates of interest (assuming independence between DCS and VGE) and then ultimately be extended to acknowledge dependencies between DCS and VGE. Our DCS and VGE data are from 1,031 hypobaric decompressions from 1983 to 2016. A total of 577 humans participated in 49 hypobaric chamber tests to evaluate denitrogenation procedures used by astronauts in the Space Shuttle and International Space Station programs. We defined decompression dose as the ratio of computed nitrogen tension in a theoretical 360-minute half-time compartment to ambient pressure, which accounts for denitrogenation and exposure pressure as well as explanatory variables such as age, sex, body mass index, and the presence or absence of ambulation as part of exercise at the exposure pressure. A parametric survival model, using a log-logistic distribution, was used to quantify the time to development of DCS, VGE, and Grade IV VGE. Results: Our survival estimates are applicable to simple hypobaric decompressions, such as depressurizations in 5 to 30 minutes to exposure pressures between 4 and 10 pounds per square inch absolute (psia) and after minutes to hours of denitrogenation, either under resting or exercise conditions to accelerated denitrogenation. The regressions are applicable to exposures between 2 to 6 hours and under conditions of ambulation or no ambulation as part of exercise at the test pressure. We estimate that an exposure to 4.3 psia with simulated extravehicular activity (EVA) that includes ambulation after equilibration to the exploration atmosphere at 8.2 psia with a 34% oxygen atmosphere will result in 3.1% DCS (1.8% to 5.2 95% confidence interval), 23.2% VGE (16.7 to 31.2%), and 8.5% Grade IV VGE (4.7 to 14.7%) in equal samples of men and women exposed for 6 hours. Discussion: Probabilistic models for DCS, VGE, and Grade IV VGE can be used to inform those that plan future EVAs. Their applications are useful to quantify the risk of DCS and VGE in astronauts that perform EVAs in low-pressure space suits while in space or while exploring the surfaces of the moon or Mars.

Johnny Conkin↗

Evaluation of SPE and GCR Radiation Effects in Inflatable, Space Suit and Composite Habitat Materials Project

The radiation resistance of polymeric and composite materials to space radiation is currently based on irradiating materials with Co-60 gamma-radiation to the equivalent total ionizing dose (TID) expected during mission. This is an approximation since gamma-radiation is not truly representative of the particle species; namely, Solar Particle Event (SPE) protons and Galactic Cosmic Ray (GCR) nucleons, encountered in space. In general, the SPE and GCR particle energies are much higher than Co-60 gamma-ray photons, and since the particles have mass, there is a displacement effect due to nuclear collisions between the particle species and the target material. This effort specifically bridges the gap between estimated service lifetimes based on decades old Co-60 gamma-radiation data, and newer assessments of what the service lifetimes actually are based on irradiation with particle species that are more representative of the space radiation environment.

Waller, Jess M.↗

Assessing the Health and Performance Risks of Reduced Carbon Dioxide Exposures and Resource Utilization

There have been a cluster of anecdotal reports that ISS crews are experiencing adverse health effects from on orbit exposure to CO2 levels well below the current Spacecraft Maximum Allowable Concentration (SMAC), which is 5.3 mmHg for 180 days of exposure. Developing evidence that this standard should be reduced to protect crew health is not a simple process. Dr. John James' team looked at the reports of headaches by the crew during private medical conferences and matched these with CO2 levels around the time of these reports. They then compared these to CO2 levels when there were no reports of headache. Using benchmark dose modeling, they found that the risk of headache could be predicted in concentration ranges from 2 to 5 mmHg. However, the data are incomplete because there were insufficient data when crews were exposed to concentrations below 2 mmHg. James' team also asked whether neuro-cognitive effects could be identified with CO2 exposure levels and found that these could not be associated with CO2 levels. Finally, they addressed the question of resource use to meet various levels of CO2 control if the SMACs were lowered. They estimated that CO2 restrictions approaching 2 mmHg would require substantial increases in power use and up-mass resources. They are refining their data on CO2 and headaches, and are looking at potential interactions of intracranial pressure and CO2 levels in eliciting ocular effects.

James, John T.↗

Determination of the Risk of Radiation-Associated Circulatory and Cancer Disease Mortality in a NASA Early Astronaut Cohort

Of the many possible health challenges posed during extended exploratory missions to space, the effects of space radiation on cardiovascular disease and cancer are of particular concern. There are unique challenges to estimating those radiation risks; care and appropriate and rigorous methodology should be applied when considering small cohorts such as the NASA astronaut population. The objective of this work was to determine if there was sufficient evidence for excess risk of cardiovascular disease and cancer in early NASA astronaut cohorts. NASA astronauts in selection groups 1-7 were chosen; this relatively homogeneous cohort consists of 73 white males, who unlike today's astronauts, maintained similar smoking and drinking habits to the general US population, and have published radiation doses. The participants flew in space on missions Mercury through Shuttle and received space radiation doses between 0-74.1 milligrays. Cause of death information was obtained from the Lifetime Surveillance of Astronaut Health (LSAH) program at NASA Johnson Space Center. Mortality was compared with the US male population. Trends of mortality with dose were assessed using a logistic model, fitted by maximum likelihood. Only 32 (43.84 percent) of the 73 early astronauts have died. Standard mortality ratios (SMRs) for cancer (n=7, SMR=43.4, 95 percent CI 17.8, 84.9), all circulatory disease (n=7, SMR=33.2, 95 percent CI 13.7, 65.0), and ischemic heart disease (IHD) (n=5, SMR=40.1, 95 percent CI 13.2, 89.4) were significantly lower than for the US white male population. For cerebrovascular disease, the upper confidence interval for SMR included 100, indicating it was not significantly different from the US population (n=2, SMR = 77.0, 95 percent CI 9.4, 268.2). The power of the study is low and remains below 10 percent even when risks 10 times those reported in the literature are assumed. Due to small sample size, there is currently insufficient statistical power to evaluate space radiation exposure effects on mortality in NASA astronauts. In addition to a comprehensive longitudinal study of NASA astronauts, a research strategy of low dose epidemiology data integration with cell and animal studies should be utilized for space radiation risk assessment in the astronauts.

Elgart, S. R.↗

Relative Bioavailability of Scopolamine Dosage Forms and Interaction with Dextroamphetamine

The NASA Reduced Gravity Office (RGO) uses scopolamine (SCOP) and in combination with dextoamphetamine (DEX) to manage motion sickness symptoms during parabolic flights. The medications are dispensed as custom dosage forms as gelatin capsules. Anecdotal evidence of efficacy suggests that these formulations are unreliable and less efficacious for the treatment of motion sickness. We estimated bioavailability of four different oral formulations used by NASA for the treatment of motion sickness. Twelve healthy, non-smoking subjects between 21and 48 years of age received four treatments on separate days in a randomized fashion; the treatments were 0.8 mg SCOP alone as tablet, 0.8 mg SCOP alone in gel cap, 0.8 mg SCOP and 10 mg DEX as tablets, and 0.8 mg SCOP and 10 mg DEX in gel cap. After each treatment, blood, saliva, and urine samples were collected at scheduled time intervals for 24 h after dosing. Bioavailability and pharmacokinetic parameters were calculated and compared using ANOVA. After administration of SCOP tablets alone, maximum concentration (C(sub max)) and time for maximum concentration (t(sub max)) were 0.26 plus or minus 0.04 ng/mL and 0.71 plus or minus 0.02 h, respectively; volume of distribution, and clearance were 47.6 plus or minus 4.72 L/kg and 23.0 plus or minus 4.58 L/h/kg, respectively. SCOP t(sub max) after administration as gelcaps was significantly longer than that with tablets (1.04 h, p less than 0.05), but no significant differences in other pharmacokinetic parameters of SCOP were observed between the two dosage forms. When coadministered with DEX, the area underneath the concentration versus time curve (AUC) of SCOP was significantly reduced to 0.61 plus or minus 0.09 and 0.64 plus or minus 0.11 ng (raised dot) h/mL after administration as a tablet or gelcap formulation, respectively; SCOP C(sub max) was lower after coadministration with DEX, this difference, however, was not statistically significant. Delayed absorption with gelcaps coupled with reduced bioavailability with DEX coadministration may have resulted in the observed treatment failure with some of these formulations. This could result from failure to reach minimum effective concentrations after treatment with gelcap formulations before parabolic flights. A new nomogram for dosing is proposed for treatment with SCOP gelcaps or SCOP-DEX combination.

Boyd, Jason L.↗

Bioavailability of Promethazine during Spaceflight

Promethazine (PMZ) is the choice anti-motion sickness medication for treating space motion sickness (SMS) during flight. The side effects associated with PMZ include dizziness, drowsiness, sedation, and impaired psychomotor performance which could impact crew performance and mission operations. Early anecdotal reports from crewmembers indicate that these central nervous system side effects of PMZ are absent or greatly attenuated in microgravity, potentially due to changes in pharmacokinetics (PK) and pharmacodynamics in microgravity. These changes could also affect the therapeutic effectiveness of drugs in general and PMZ, in particular. In this investigation, we examined bioavailability and associated pharmacokinetics of PMZ in astronauts during and after space flight. Methods. Nine astronauts received, per their preference, PMZ (25 or 50 mg as intramuscular injection, oral tablet, or rectal suppository) on flight day one for the treatment of SMS and subsequently collected saliva samples and completed sleepiness scores for 72 h post dose. Thirty days after the astronauts returned to Earth, they repeated the protocol. Bioavailability and PK parameters were calculated and compared between flight and ground. Results. Maximum concentration (Cmax) was lower and time to reach Cmax (tmax) was longer in flight than on the ground. Area under the curve (AUC), a measure of bioavailability, was lower and biological half-life (t1/2) was longer in flight than on the ground. Conclusion. Results indicate that bioavailability of PMZ is reduced during spaceflight. Number of samples, sampling method, and sampling schedule significantly affected PK parameter estimates.

Boyd, Jason L.↗

Large-mutation spectra induced at hemizygous loci by low-LET radiation: evidence for intrachromosomal proximity effects

A mathematical model is used to analyze mutant spectra for large mutations induced by low-LET radiation. The model equations are based mainly on two-break misrejoining that leads to deletions or translocations. It is assumed, as a working hypothesis, that the initial damage induced by low-LET radiation is located randomly in the genome. Specifically, we analyzed data for two hemizygous loci: CD59- mutants, mainly very large-scale deletions (>3 Mbp), in human-hamster hybrid cells, and data from the literature on those HPRT- mutants which involve at least deletion of the whole gene, and often of additional flanking markers (approximately 50-kbp to approximately 4.4-Mbp deletions). For five data sets, we estimated f, the probability that two given breaks on the same chromosome will misrejoin to make a deletion, as a function of the separation between the breaks. We found that f is larger for nearby breaks than for breaks that are more widely separated; i.e., there is a "proximity effect". For acute irradiation, the values of f determined from the data are consistent with the corresponding break misrejoining parameters found previously in quantitative modeling of chromosome aberrations. The value of f was somewhat smaller for protracted irradiation than for acute irradiation at a given total dose; i.e., the mutation data show a decrease that was smaller than expected for dose protraction by fractionation or low dose rate.

Non-NASA Center↗

Potential health effects of space radiation

Crewmembers on missions to the Moon or Mars will be exposed to radiation belts, galactic cosmic rays, and possibly solar particle events. The potential health hazards due to these space radiations must be considered carefully to ensure the success of space exploration. Because there is no human radioepidemiological data for acute and late effects of high-LET (Linear-Energy-Transfer) radiation, the biological risks of energetic charged particles have to be estimated from experimental results on animals and cultured cells. Experimental data obtained to date indicate that charged particle radiation can be much more effective than photons in causing chromosome aberrations, cell killing, mutation, and tumor induction. The relative biological effectiveness (RBE) varies with biological endpoints and depends on the LET of heavy ions. Most lesions induced by low-LET radiation can be repaired in mammalian cells. Energetic heavy ions, however, can produce large complex DNA damages, which may lead to large deletions and are irreparable. For high-LET radiation, therefore, there are less or no dose rate effects. Physical shielding may not be effective in minimizing the biological effects on energetic heavy ions, since fragments of the primary particles can be effective in causing biological effects. At present the uncertainty of biological effects of heavy particles is still very large. With further understanding of the biological effects of space radiation, the career doses can be kept at acceptable levels so that the space radiation environment need not be a barrier to the exploitation of the promise of space.

Yang, Chui-Hsu↗

Evaluation of Intranasal Scopolamine for the Prevention of Wave Motion Induced Motion Sickness While Maintaining Performance on Operationally Relevant Tasks

Motion sickness represents one of the greatest clinical challenges impacting crew activities during and following g-transitions. Our overall goal is to characterize the effectiveness of motion sickness countermeasures during controlled laboratory experiments using capsule wave motion simulation and during field testing in operational environments. This laboratory study focused on prevention of motion sickness using intranasal scopolamine using a double-blinded repeated measures design in 30 subjects (19M, 11F). Intranasal scopolamine was provided by Defender Pharmaceuticals, Inc. (DPI-386 Nasal Gel, referred to as Inscop) self-administered by a nasal pump (Aptar Pharma) that delivers 0.4 mg dose (0.2 mg / nostril). During each session, subjects were exposed to complex wave motion on a six degree-of-freedom platform that included pitch, roll and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Motion sickness symptoms were compared across treatment and placebo control sessions counterbalanced across subjects and separated by at least one week. The time-to-motion sickness endpoint was based on severe malaise, defined as symptom score of ≥8 points using the Pensacola Diagnostic Index [1]. The bioavailability of scopolamine for each session was estimated from plasma concentrations obtained every 15 min[2]. Side effects during the treatment session were minimal, and performance was not impaired on a test battery including motion perception tracking, tablet-based eye-hand coordination and psychomotor vigilance testing. The plasma concentration remained near-peak levels throughout the 45 min motion sickness testing for most subjects. The percentile ranking on the Motion Sickness Susceptibility Questionnaire [MSSQ, 3]was moderately correlated with the motion sickness time-to-endpoint during the placebo control session (rho = –0.3, p=0.056). Seventeen subjects did not reach an endpoint during their placebo session and were eliminated from subsequent analysis. Another subject was excluded due to insufficient plasma concentration during the treatment session. For the remaining 12 subjects, the change in time-to-motion sickness endpoint between placebo and treatment sessions was moderately correlated with plasma concentration (rho =0.48, p = 0.056), improving on average 4.4 ± 18.4 min, mean ± std with Inscop versus placebo. Our results are consistent with previous findings that intranasal delivery of scopolamine can be effective at reducing motion sickness symptoms with minimal cognitive or sedative side effects. Future work is needed to optimize the delivery of Inscop for rescue (treatment) of symptoms following g-transitions as one of the key advantages of this formulation is self-administration in a suited environment. We will also explore how the combination of Inscop with non-pharmaceutical sensory aids, e.g., vibrotactile feedback of Earth vertical, may further mitigate motion sickness and improve task performance.

S J Wood↗

Radiation protection guidelines for space missions

NASA's current radiation protection guidelines date from 1970, when the career limit was set at 400 rem. Today, using the same approach, but with the current risk estimates, a considerably lower career limit would obtain. Also, there is considerably more information about the radiation environments to be experienced in different missions than previously. Since 1970 women have joined the ranks. For these and other reasons it was necessary to reexamine the radiation protection guidelines. This task was undertaken by the National Council on Radiation Protection and Measurements Scientific Committee 75 (NCRP SC 75). Below the magnetosphere the radiation environment varies with altitude and orbit inclination. In outer space missions galactic cosmic rays, with the small but important heavy ion component, determine the radiation environment. The new recommendations for career dose limits, based on lifetime excess risk of cancer mortality, take into account age at first exposure and sex. The career limits range from 100 rem (4.0Sv) for a 24 year old female to 400 rem for a 55 year old male compared to the previous single limit of 400 rem (4.0 Sv). The career limit for the lens of the eye was reduced from 600 to 400 rem (6.0 to 4.0 Sv.)

Fry, R. J. M.↗