Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The Doppler Wind Temperature Sensor (DWTS) Flight Evaluation and Experiments (TES-16,17)

The Doppler Wind Temperature Sensor instrument (DWTS), developed by Global Atmospheric Technologies and Sciences (GATS), is a powerful yet simple tool with the potential of becoming a new window to upper atmosphere dynamics. Based around a defense-grade infrared camera peering through a static gas cell used as a scanning spectral filter, the DWTS is designed to measure the fingerprints of wind and thermal waves as they propagate to the mesosphere and lower thermosphere. DWTS achieves this scanning by measuring the induced change in the doppler shift of the emission as it passes through the DWTS field of view. DWTS holds promise to aid in more accurate weather determination (Gordley, et al), and the core technology can be easily adapted to study other atmospheres of interest. In partnership with GATS, NOAA, and other collaborators, NASA Ames and the Nano Orbital Workshop group have been working to evaluate the DWTS instrument on orbit and optimize it as a flexible cube satellite payload. The first mission selected for DWTS evaluation is preparing for flight in early 2024, followed by a more capable science mission in 2025, with both missions part of the TES-n/NOW flight series. The first flight, TES-16/DWTS-A, will incorporate a single DWTS instrument in an approximately 2U payload volume with the imaging aperture perpendicular to the flight velocity vector. With an estimated power consumption of 20 watts, supplied via a custom NOW-designed GaN converter, the instrument will maintain the imaging sensor plane at 80K using an integrated pulse-tube cryocooler during instrument evaluation periods. Data from DWTS will be captured via a NOW-designed custom data processor before being transmitted via S-band radio back to select ground stations, with instrument command and control operated via L-band global-coverage radio. After the TES-16/DWTS-A initial demonstration mission, the subsequent TES-17/DWTS-B mission will be a dedicated science mission equipped with three DWTS instruments, each hosting a different gas cell to obtain full altitude coverage from 20 to 200 km both day and night from a single cube satellite. The intention of the flight series, and one of NASA’s interests in the instrument, is to advance a Martian atmospheric instrument (Colaprete, Gordley, et al) which, if successful, would greatly further understanding of Martian atmospheric behavior. The proposed paper will review the flight series in detail, including challenges from the TES-16 flight tests and the projected challenges and application to Mars study. Additional detail regarding the possible applications of a Cognitive Communication technique in current flight development by NOW collaborators at the NASA Glenn Research Center will also be discussed, including the implications of using an automated User Initiated Service (UIS) protocol to maximize the data collected per orbit.

Doppler Wind Temperature Sensor↗

On mechanical waves and Doppler shifts from moving boundaries

We investigate the propagation of infinitesimal harmonic mechanical waves emitted from a boundary with variable velocity and arriving at a stationary observer. In the classical Doppler effect, X s (t)=vt is the location of the source with constant velocity v. In the present work, however, we consider a source co-located with a moving boundary x=X s (t), where X s (t) can have an arbitrary functional form. For ‘slowly moving’ boundaries (i.e., ones for which the timescale set by the mechanical motion is large in comparison to the inverse of the frequency of the emitted wave), we present a multiple-scale asymptotic analysis of the moving boundary problem for the linear wave equation. Here, we obtain a closed-form leading-order (with respect to the latter small parameter) solution and show that the variable velocity of the boundary results not only in frequency modulation but also in amplitude modulation of the received signal. Consequently, our results extend the applicability of two basic tenets of the theory of a moving source on a stationary domain, specifically that (i) $.\atop{x}_s$ for non-uniform boundary motion can be inserted in place of the constant velocity v in the classical Doppler formula and (ii) that the non-uniform boundary motion introduces variability in the amplitude of the wave. The specific examples of decelerating and oscillatory boundary motion are worked out and illustrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient Computation of Doppler-Broadened Elastic Scattering Kernel Moments Using Ladder-Operator Formulation

Anefficient routine for computing Legendre moments of the Doppler-broadened elastic scattering kernel, including resonance scattering effects, has been implemented in the ISOXML module of Griffin. Isotropic scattering in the center-of-mass system and the ideal gas model for target motion are assumed. A ladder-operator formulation is introduced to compute all Legendre moments from order 0 to N simultaneously, enabling near-linear scaling of computational cost with respect to the maximum Legendre order. A physics-based strategy for constructing outgoing energy grids has also been developed, in which a tailored base grid is combined with adaptive refinement to maintain accuracy while limiting the number of outgoing energy points. For energies between resonances, a constant cross-section model is employed to further reduce computational cost. In addition, a quantitative criterion is derived to determine isotope-wise cut-off incident energies based on a prescribed up-scattering probability coverage. For 238U, up to incident energies of approximately 75, 230, and 661 eV at 294, 900, and 2500 K (corresponding to a 2% up-scattering probability threshold), computation of P0 kernels requires 1–8 s and computation of P0–P5 kernels requires 0.4–4 min using a single thread, while maintaining 1–3% relative error in up-scattering probability. These results demonstrate that the proposed formulation enables accurate and computationally practical Doppler-broadened kernel generation for online multigroup cross-section production in Griffin.

Doppler-broadening↗

On-the-fly Doppler broadening of unresolved resonance region cross sections

In this paper, two methods for computing temperature-dependent unresolved resonance region cross sections on-the-fly within continuous-energy Monte Carlo neutron transport simulations are presented. The first method calculates Doppler broadened cross sections directly from zero-temperature average resonance parameters. In a simulation, at each event that requires cross section values, a realization of unresolved resonance parameters is generated about the desired energy and temperature-dependent single-level Breit-Wigner resonance cross sections are computed directly via the analytical Ψ-x Doppler integrals. The second method relies on the generation of equiprobable cross section magnitude bands on an energy-temperature mesh. Within a simulation, the bands are sampled and interpolated in energy and temperature to obtain cross section values on-the-fly. Both of the methods, as well as their underlying calculation procedures, are verified numerically in extensive code-to-code comparisons. Energy-dependent pointwise cross sections calculated with the newly-implemented procedures are shown to be in excellent agreement with those calculated by a widely-used nuclear data processing code. Relative differences at or below 0.1% are observed. Integral criticality benchmark results computed with the proposed methods are shown to reproduce those computed with a state-of-the-art processed nuclear data library very well. In simulations of fast spectrum systems which are highly-sensitive to the representation of cross section data in the unresolved region, k-eigenvalue and neutron flux spectra differences of <10 pcm and <1.0% are observed, respectively. The direct method is demonstrated to be well-suited to the calculation of reference solutions — against which results obtained with a discretized representation may be assessed — as a result of its treatment of the energy, temperature, and cross section magnitude variables as continuous. Also, because there is no pre-processed data to store (only temperature-independent average resonance parameters) the direct method is very memory-efficient. Typically, only a few kB of memory are needed to store all required unresolved region data for a single nuclide. However, depending on the details of a particular simulation, performing URR cross section calculations on-the-fly can significantly increase simulation times. Alternatively, the method of interpolating equiprobable probability bands is demonstrated to produce results that are as accurate as the direct reference solutions, to within arbitrary precision, with high computational efficiency in terms of memory requirements and simulation time. Analyses of a fast spectrum system show that interpolation on a coarse energy-temperature mesh can be used to reproduce reference k-eigenvalue results obtained with cross sections calculated continuously in energy and directly at an exact temperature to within <10 pcm. Probability band data on a mesh encompassing the range of temperatures relevant to reactor analysis usually require around 100 kB of memory per nuclide. Finally, relative to the case in which probability table data generated at a single, desired temperature are used, minor increases in simulation times are observed when probability band interpolation is employed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CDB-AP: An application for coincidence Doppler broadening spectroscopy analysis

Coincidence Doppler Broadening (CDB) Positron Annihilation Spectroscopy (PAS) is a material analysis technique that can be used to non-destructively measure characteristics of structural defects in samples. Analyzing and comparing large datasets obtained using this technique, however, can be complicated and time intensive. The Coincidence Doppler Broadening Analysis Program (CDB-AP) is a graphical user interface that facilitates rapid analysis of many data files while using transparent processes. It is already used in three laboratories at Idaho National Laboratory and can be used in laboratories worldwide.

36 MATERIALS SCIENCE↗

Reconciling differences between large-eddy simulations and Doppler-lidar observations of continental shallow cumulus cloud-base vertical velocity

We investigate a significant model-observation difference found between cloud-base vertical velocity for continental shallow cumulus simulated using large-eddy simulations (LES) and observed by Doppler lidar measurements over the U.S. Southern Great Plains ARM Facility. The LES cloud-base vertical velocity is dominated by updrafts that are consistent with a general picture for convective clouds but is inconsistent with Doppler lidar observations that also show the presence of considerable downdrafts. The underestimation of simulated downdrafts is found to be a robust feature, being insensitive to various numerical, physical, or dynamical choices. We find that simulations can more closely reproduce observations only after improving the model physics to use size-resolved microphysics and horizontal longwave radiation, both of which modify the cloud buoyancy and velocity structure near cloud side edges. The results suggest that treatments that capture these structures are needed for the proper simulation and subsequent parameterization development of shallow cumulus vertical transport.

54 ENVIRONMENTAL SCIENCES↗

Covariance Matrix of a Double-Differential Doppler-broadened Elastic Scattering Cross Section

Legendre moments of a double-differential Doppler-broadened elastic neutron scattering cross section on {sup 238}U are computed near the 6.67 eV resonance at temperature T = 10{sup 3} K up to angular order 14. A covariance matrix of these Legendre moments is computed as a functional of the covariance matrix of the elastic scattering cross section. A variance of double-differential Doppler-broadened elastic scattering cross section is computed from the covariance of Legendre moments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Doppler spectroscopy of hydrogen Balmer lines in a hollow cathode glow discharge in ammonia and argon-ammonia mixture

The results of Doppler spectroscopy of hydrogen Balmer lines from a stainless steel (SS) and copper (Cu) hollow cathode (HC) glow discharge in ammonia and argon-ammonia mixture are reported. The experimental profiles in ammonia discharge are fitted well by superposing three Gaussian profiles. The half widths, in energy units, of narrow and medium Gaussians are in the ranges 0.3-0.4 eV and 3-4 eV, respectively, for both hollow cathodes what is expected on the basis of earlier electron beam{yields}NH{sub 3} experiments. The half widths of the largest Gaussian in ammonia are 46 and 55 eV for SS and Cu HC, respectively. In argon-ammonia discharge, three Gaussians are also required to fit experimental profiles. While half widths of narrow and medium Gaussians are similar to those in ammonia, the half widths of the largest Gaussians are 35 and 42 eV for SS and Cu HC, respectively. The half widths of the largest Gaussians in ammonia and in argon-ammonia mixture indicate the presence of excessive Doppler broadening.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring D(d,p)T fusion reactant energy spectra with Doppler shifted fusion products

Deuterium fusion reactant energy spectra have been measured using a diagnostic that records the Doppler shift imparted to charged particle fusion products of the D(d,p)T reaction by the center-of-mass velocity of the deuterium reactants. This diagnostic, known as the fusion ion Doppler shift diagnostic (FIDO) measures fast deuterium energy spectra in the inertial electrostatic confinement (IEC) experiment at the University of Wisconsin-Madison {l_brace}Santarius et al. [Fusion Sci. Technol. 47, 1238 (2005)]{r_brace}, a device to confine high energy light ions in a spherically symmetric, electrostatic potential well. This article details the first measurements of the fusion reactant energy spectra in an IEC device as well as the design and principles of operation of the FIDO diagnostic. Scaling of reactant energy spectra with a variety of experimental parameters have been explored.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the role of spectral resolution in velocity shear layer measurements by Doppler reflectometry

The signal quality of a Doppler reflectometer depends strongly on its spectral resolution, which is influenced by the microwave beam properties and the radius of curvature of the cutoff layer in the plasma. If measured close to a strong perpendicular velocity shear layer, the spectrum of the backscattered signal is influenced by different velocities. This can give rise to two Doppler shifted peaks in the spectrum as observed in TJ-II H-mode plasmas. It is shown by two-dimensional full wave simulations that the two peaks are separable provided the spectral resolution of the system is sufficient. However, if the spectral resolution is poor, the two peaks blend into one and yield an intermediate and incorrect velocity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasioptical design of integrated Doppler backscattering and correlation electron cyclotron emission systems on the DIII-D tokamak

The quasioptical design of a new integrated Doppler backscattering (DBS) and correlation electron cyclotron emission (CECE) system is presented. The design provides for simultaneous measurements of intermediate wavenumber density and long wavelength electron temperature turbulence behavior. The Doppler backscattering technique is sensitive to plasma turbulence flow and has been utilized to determine radial electric field, geodesic acoustic modes, zonal flows, and intermediate scale (k{approx}1-6 cm{sup -1}) density turbulence. The correlation ECE system measures a second turbulent field, electron temperature fluctuations, and is sensitive to long poloidal wavelength (k{<=}1.8 cm{sup -1}). The integrated system utilizes a newly installed in-vessel focusing mirror that produces a beam waist diameter of 3.5-5 cm in the plasma depending on the frequency. A single antenna (i.e., monostatic operation) is used for both launch and receive. The DBS wavenumber is selected via an adjustable launch angle and variable probing frequency. Due to the unique system design both positive and negative wavenumbers can be obtained, with a range of low to intermediate wavenumbers possible (approximately -3 to 10 cm{sup -1}). A unique feature of the design is the ability to place the DBS and CECE measurements at the same radial and poloidal locations allowing for cross correlation studies (e.g., measurement of nT cross-phase).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of photonic Doppler velocimetry data based on the continuous wavelet transform

The short time Fourier transform (STFT) cannot resolve rapid velocity changes in most photonic Doppler velocimetry (PDV) data. A practical analysis method based on the continuous wavelet transform (CWT) was presented to overcome this difficulty. The adaptability of the wavelet family predicates that the continuous wavelet transform uses an adaptive time window to estimate the instantaneous frequency of signals. The local frequencies of signal are accurately determined by finding the ridge in the spectrogram of the CWT and then are converted to target velocity according to the Doppler effects. A performance comparison between the CWT and STFT is demonstrated by a plate-impact experiment data. The results illustrate that the new method is automatic and adequate for analysis of PDV data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Doppler vibrometry for assessment of arteriosclerosis: A first step towards validation

It has been shown that in cardiovascular risk management, stiffness of large arteries has a very good predictive value for cardiovascular disease and mortality. This parameter can be estimated from the pulse wave velocity (PWV) measured between the common carotid artery (CCA) in the neck and femoral artery (FA) in the groin. However PWV can also be measured locally in the CCA, using non-invasive methods such as ultrasound (US) or laser Doppler vibrometry (LDV). Potential of the latter approach was already explored in previous research, and in this work a first step towards clinical validation is made. 50 hypertension II/III patients aged between 30 and 65 participate in the study. Patients were asked to remain sober for 4 hours prior to the measurements. The trajectory of the CCA in the neck was determined by a trained clinician guided by an US probe. 3 laser Doppler vibrometer (LDV) systems were aimed along the CCA. PWV was then calculated from the distance between beams and the time-shift between waveforms. Immediately after LDV measurements, PWV was measured with US. Additionally, carotid-femoral PWV was measured. As a validation, PWV results of the different techniques were compared with each other, and with medical background of the test subjects. Since data acquisition is still ongoing, data from only 20 patients will be discussed. No trends between measurement methods for PWV are apparent. However, a positive trend was detected between PWV as measured with LDV and blood pressure. More data, including additional experiments will be needed to verify this observation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous-scanning laser Doppler vibrometry: Extensions to arbitrary areas, multi-frequency and 3D capture

To date, differing implementations of continuous scan laser Doppler vibrometry have been demonstrated by various academic institutions, but since the scan paths were defined using step or sine functions from function generators, the paths were typically limited to 1D line scans or 2D areas such as raster paths or Lissajous trajectories. The excitation was previously often limited to a single frequency due to the specific signal processing performed to convert the scan data into an ODS. In this paper, a configuration of continuous-scan laser Doppler vibrometry is demonstrated which permits scanning of arbitrary areas, with the benefit of allowing multi-frequency/broadband excitation. Various means of generating scan paths to inspect arbitrary areas are discussed and demonstrated. Further, full 3D vibration capture is demonstrated by the addition of a range-finding facility to the described configuration, and iteratively relocating a single scanning laser head. Here, the range-finding facility was provided by a Microsoft Kinect, an inexpensive piece of consumer electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a Doppler reflectometer for KSTAR

A Doppler reflectometer has been designed to measure the poloidal propagation velocity on the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. It has the operating frequency range of V-band (50-75 GHz) and the monostatic antenna configuration with extraordinary mode (X-mode). The single sideband modulation with an intermediate frequency of 50 MHz is used for the heterodyne measurement with the 200 MHz in-phase and quadrature (I/Q) phase detector. The corrugated conical horn antenna is used to approximate the Gaussian beam propagation and it is installed together with the oversized rectangular waveguides in the vacuum vessel. The first commissioning test of the Doppler reflectometer system on the KSTAR tokamak is planned in the 2014 KSTAR experimental campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In vivo visualization method by absolute blood flow velocity based on speckle and fringe pattern using two-beam multipoint laser Doppler velocimetry

Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensional space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvements to the Ion Doppler Spectrometer Diagnostic on the HIT-SI Experiments

An Ion Doppler Spectrometer diagnostic system measuring impurity ion temperature and velocity on the HIT-SI and HIT-SI3 spheromak devices has been improved with higher spatiotemporal resolution and lower error than previously described devices. Hardware and software improvements to the established technique have resulted in a record 6.9 µs temporal and <=2.8 cm spatial resolution in the midplane of each device. These allow C III and O II flow, displacement, and temperature profiles to be simultaneously observed. With 72 fused-silica fiber channels in two independent bundles, and an f/8.5 Czerny-Turner spectrometer coupled to video camera, frame-rates of up to ten times the imposed magnetic perturbation frequency of 14.5 kHz were achieved in HIT-SI, viewing the upper 1/2 of the midplane. In HIT-SI3 frame-rates of up to eight times the perturbation frequency were achieved viewing both halves of the midplane. Biorthogonal Decomposition is used as a novel filtering tool, reducing uncertainty in ion temperature from <=13 to <=5 eV (with an instrument temperature of 8-16 eV), and uncertainty in velocity from <=2 to <=1 km/s. Doppler shift and broadening is calculated via the Levenberg-Marquart algorithm, after which errors in velocity and temperature are uniquely specified. Axisymmetric temperature profiles on HIT-SI3 for C III peaked near the inboard current separatrix at approximately 40 eV are observed. Axisymmetric plasma displacement profiles have been measured on HIT-SI3, peaking at approximately 6 cm at the outboard separatrix. Both profiles agree with the upper half of the midplane observable by HIT-SI. With its complete midplane view, HIT-SI3 has unambiguously extracted axisymmetric, toroidal current dependent rotation of up to 3 km/s. Analysis of the temporal phase of the displacement uncovers a coherent structure, locked to the applied perturbation. Previously described diagnostic systems could not achieve such results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗