Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed Network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Comment on 'A dramatic decrease in the growth rate of atmospheric methane in the Northern Hemisphere during 1992' by E. J. Dlugokencky et al.

The carefully measured decrease in the growth rate of atmospheric methane (CH4) in 1992 reported by Dlugokencky et al. (1994) is an impressive accomplishment, and testimony for the importance of maintaining high-quality, long-term monitoring of atmospheric composition. The changing growth rate of atmospheric CH4 has important implications for assessing and understanding the potential magnitude and rates of a future greenhouse gas-induced climate change. Furthermore, the CH4 data from the current Climate Monitoring and Diagnostics Laboratory (CMDL) globally-distributed network of cooperative air sampling sites are clearly the best record of global CH4 trends and distribution currently available. However, we argue briefly here that the speculation by Dlugokencky et al. (1994) on possible mechanisms for the decreased growth rate in 1992 is only one scenario of many that could possibly fit with the constraints imposed by the reported data. Our comments are to (1) illustrate the difficulties of deducing small changes in complex, poorly understood, geographically diverse natural and anthropogenic sources of CH4 from measurements at the remotely-located CMDL sampling sites and (2) emphasize that detailed bottoms-up analyses are necessary to really advance the understanding of changes in source strengths; we are not promoting alternative mechanisms to explain the 1992 decrease in atmospheric CH4.

Hogan, Kathleen B.↗

Distributed Energy Management for Networked Microgrids with Hardware-in-the-Loop Validation

For the cooperative operation of networked microgrids, a distributed energy management considering network operational objectives and constraints is proposed in this work. Considering various ownership and privacy requirements of microgrids, utility directly interfaced distributed energy resources (DERs) and demand response, a distributed optimization is proposed for obtaining optimal network operational objectives with constraints satisfied through iteratively updated price signals. The alternating direction method of multipliers (ADMM) algorithm is utilized to solve the formulated distributed optimization. The proposed distributed energy management provides microgrids, utility-directly interfaced DERs and responsive demands the opportunity of contributing to better network operational objectives while preserving their privacy and autonomy. Results of numerical simulation using a networked microgrids system consisting of several microgrids, utility directly interfaced DERs and responsive demands validate the soundness and accuracy of the proposed distributed energy management. The proposed method is further tested on a practical two-microgrid system located in Adjuntas, Puerto Rico, and the applicability of the proposed strategy is validated through hardware-in-the-loop (HIL) testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Very Large Area Network (VLAN) knowledge-base applied to space communication problems

This paper first describes a hierarchical model for very large area networks (VLAN). Space communication problems whose solution could profit by the model are discussed and then an enhanced version of this model incorporating the knowledge needed for the missile detection-destruction problem is presented. A satellite network or VLAN is a network which includes at least one satellite. Due to the complexity, a compromise between fully centralized and fully distributed network management has been adopted. Network nodes are assigned to a physically localized group, called a partition. Partitions consist of groups of cell nodes with one cell node acting as the organizer or master, called the Group Master (GM). Coordinating the group masters is a Partition Master (PM). Knowledge is also distributed hierarchically existing in at least two nodes. Each satellite node has a back-up earth node. Knowledge must be distributed in such a way so as to minimize information loss when a node fails. Thus the model is hierarchical both physically and informationally.

Zander, Carol S.↗

LBNL Cell controller v1.0

Firmware and software of LBNL's Cell controller logic. Cell logic forms a high-speed data distribution network of FPGAs, transmitting data in a ring topology. This logic is used at ALS for the distribution of BPM data as part of the fast orbit feedback system.

Norum, William↗

Quantifying the generalization error in deep learning in terms of data distribution and neural network smoothness

We report the accuracy of deep learning, i.e., deep neural networks, can be characterized by dividing the total error into three main types: approximation error, optimization error, and generalization error. Whereas there are some satisfactory answers to the problems of approximation and optimization, much less is known about the theory of generalization. Most existing theoretical works for generalization fail to explain the performance of neural networks in practice. To derive a meaningful bound, we study the generalization error of neural networks for classification problems in terms of data distribution and neural network smoothness. We introduce the cover complexity (CC) to measure the difficulty of learning a data set and the inverse of the modulus of continuity to quantify neural network smoothness. A quantitative bound for expected accuracy/error is derived by considering both the CC and neural network smoothness. Although most of the analysis is general and not specific to neural networks, we validate our theoretical assumptions and results numerically for neural networks by several data sets of images. The numerical results confirm that the expected error of trained networks scaled with the square root of the number of classes has a linear relationship with respect to the CC. We also observe a clear consistency between test loss and neural network smoothness during the training process. In addition, we demonstrate empirically that the neural network smoothness decreases when the network size increases whereas the smoothness is insensitive to training dataset size.

97 MATHEMATICS AND COMPUTING↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

Highly Efficient Amplifier for Ka-Band Communications

An amplifier developed under a Small Business Innovation Research (SBIR) contract will have applications for both satellite and terrestrial communications. This power amplifier uses an innovative series bias arrangement of active devices to achieve over 40-percent efficiency at Ka-band frequencies with an output power of 0.66 W. The amplifier is fabricated on a 2.0- by 3.8-square millimeter chip through the use of Monolithic Microwave Integrated Circuit (MMIC) technology, and it uses state-of-the-art, Pseudomorphic High-Electron-Mobility Transistor (PHEMT) devices. Although the performance of the MMIC chip depends on these high-performance devices, the real innovations here are a unique series bias scheme, which results in a high-voltage chip supply, and careful design of the on-chip planar output stage combiner. This design concept has ramifications beyond the chip itself because it opens up the possibility of operation directly from a satellite power bus (usually 28 V) without a dc-dc converter. This will dramatically increase the overall system efficiency. Conventional microwave power amplifier designs utilize many devices all connected in parallel from the bias supply. This results in a low-bias voltage, typically 5 V, and a high bias current. With this configuration, substantial I(sup 2) R losses (current squared times resistance) may arise in the system bias-distribution network. By placing the devices in a series bias configuration, the total current is reduced, leading to reduced distribution losses. Careful design of the on-chip planar output stage power combiner is also important in minimizing losses. Using these concepts, a two-stage amplifier was designed for operation at 33 GHz and fabricated in a standard MMIC foundry process with 0.20-m PHEMT devices. Using a 20-V bias supply, the amplifier achieved efficiencies of over 40 percent with an output power of 0.66 W and a 16-dB gain over a 2-GHz bandwidth centered at 33 GHz. With a 28-V bias, a power level of 1.1 W was achieved with a 12-dB gain and a 36-percent efficiency. This represents the best reported combination of power and efficiency at this frequency. In addition to delivering excellent power and gain, this Ka-band MMIC power amplifier has an efficiency that is 10 percent greater than existing designs. The unique design offers an excellent match for spacecraft applications since the amplifier supply voltage is closely matched to the typical value of spacecraft bus voltage. These amplifiers may be used alone in applications of 1 W or less, or several may be combined or used in an array to produce moderate power, Ka-band transmitters with minimal power combining and less thermal stress owing to the combination of excellent efficiency and power output. The higher voltage operation of this design may also save mass and power because the dc-dc power converter is replaced with a simpler voltage regulator.

Source record↗

LaRC local area networks to support distributed computing

The Langley Research Center's (LaRC) Local Area Network (LAN) effort is discussed. LaRC initiated the development of a LAN to support a growing distributed computing environment at the Center. The purpose of the network is to provide an improved capability (over inteactive and RJE terminal access) for sharing multivendor computer resources. Specifically, the network will provide a data highway for the transfer of files between mainframe computers, minicomputers, work stations, and personal computers. An important influence on the overall network design was the vital need of LaRC researchers to efficiently utilize the large CDC mainframe computers in the central scientific computing facility. Although there was a steady migration from a centralized to a distributed computing environment at LaRC in recent years, the work load on the central resources increased. Major emphasis in the network design was on communication with the central resources within the distributed environment. The network to be implemented will allow researchers to utilize the central resources, distributed minicomputers, work stations, and personal computers to obtain the proper level of computing power to efficiently perform their jobs.

Riddle, E. P.↗

Three-Dimensional Grid Visualization for Planning Activities: A Dubai Case Study

National Laboratory of the Rockies (NLR), in collaboration with the Dubai Electricity and Water Authority (DEWA) and Infra-X, has undertaken the Energy Visualization Analysis Project. The aim of this project is to enhance analytical and 3D visualization capabilities for distribution network planning and renewable energy integration. As modern grid continues to evolve with large-scale solar PV deployment and emerging distributed energy resources (DERs), the ability to effectively analyze, visualize, and communicate complex grid behaviors has become increasingly critical. The project focuses on developing empirical use cases based on real distribution feeder data and engineering workflows, ensuring the outcomes are directly aligned with operational environment. Through time-series power flow simulations and nodal hosting capacity analysis, the study quantifies the impacts of high PV penetration on voltage and thermal limits within representative 11 kV feeders. These analyses identify specific nodes and conditions where DER integration challenges arise. Furthermore, a Battery Energy Storage System (BESS) optimization algorithm was applied to determine the optimal size and placement of storage systems that can mitigate network constraints and enhance hosting capacity. The comparative results between base-case and BESS-augmented scenarios clearly demonstrate improvements in network stability and load management efficiency. In parallel, the NLR team developed an immersive 3D visualization framework, enabling interactive exploration of grid simulations using commodity head-mounted display (HMD) systems. This framework transforms conventional 2D simulation data into spatially intuitive visual environments - allowing engineers to analyze feeder conditions, PV hosting potential, and BESS effects in real time. This report represents the first foundational phase in establishing a visualization-driven analytical ecosystem. It provides a methodological foundation for data integration, visualization architecture, and simulation-based decision support, paving the way for large-scale adoption of immersive visualization across DEWA's Smart Grid Initiative, R&D activities, and future network resilience studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Considerations for Grid-Connected Batteries with Hardware Demonstrations

The share of renewable and distributed energy resources (DERs), like wind turbines, solar photovoltaics and grid-connected batteries, interconnected to the electric grid is rapidly increasing due to reduced costs, rising efficiency, and regulatory requirements aimed at incentivizing a lower-carbon electricity system. These distributed energy resources differ from traditional generation in many ways including the use of many smaller devices connected primarily (but not exclusively) to the distribution network, rather than few larger devices connected to the transmission network. DERs being installed today often include modern communication hardware like cellular modems and WiFi connectivity and, in addition, the inverters used to connect these resources to the grid are gaining increasingly complex capabilities, like providing voltage and frequency support or supporting microgrids. To perform these new functions safely, communications to the device and more complex controls are required. The distributed nature of DER devices combined with their network connectivity and complex controls interfaces present a larger potential attack surface for adversaries looking to create instability in power systems. To address this area of concern, the steps of a cyberattack on DERs have been studied, including the security of industrial protocols, the misuse of the DER interface, and the physical impacts. These different steps have not previously been tied together in practice and not specifically studied for grid-connected storage devices. In this work, we focus on grid-connected batteries. We explore the potential impacts of a cyberattack on a battery to power system stability, to the battery hardware, and on economics for various stakeholders. We then use real hardware to demonstrate end-to-end attack paths exist when security features are disabled or misconfigured. Our experimental focus is on control interface security and protocol security, with the initial assumption that an adversary has gained access to the network to which the device is connected. We provide real examples of the effectiveness of certain defenses. This work can be used to help utilities and other grid-connected battery owners and operators evaluate the severity of different threats and the effectiveness of defense strategies so they can effectively deploy and protect grid-connected storage devices.

25 ENERGY STORAGE↗

Feasibility of critical infrastructure protection using network functions for programmable and decoupled ICS policy enforcement over WAN

Industrial control systems (ICS) represent a major component of our critical infrastructure. With the increasing need for more control and monitoring of such systems, ICS have seen an increase in connectivity to wide area networks (WAN) exposing aging equipment to rapidly evolving cybersecurity threats. Furthermore, the ICS data requires a reliability measure from the networks for critical functions for infrastructure monitoring and control. Especially when remote plant sites are involved such as pipelines, energy distribution networks, and transportation, WAN transport impairments most often provide a best effort delivery with no strict reliability guarantees. Network functions can provide a vendor agnostic, programmable critical infrastructure protection with a single maintenance, policy determination, and reliability assurance surface. A network function (NF) can be utilized for policy enforcement over the communication between remote entities and the main control office. This paper presents the research on transparent integration with existing ICS without disrupting communications, resulting in minimal downtime while decoupling the fast paced evolution of defensive security measures from the upgrade cycle of expensive long term hardware. We report our measurements on the resource requirements and overhead in the network for successful NF insertion under a wide variety of network impairments (network packet delay, reordering, and loss). Our paired NF implementation provides a policy enforcement platform extensible to cover myriad cybersecurity-related communication goals, including packet signing for verification, encryption for data privacy, packet filtering and data diode operation (i.e. protecting against eavesdropping, packet injection, and denial-of-service). Furthermore, bundling communication specifications into packet flows allows for tunability in applying policies as coarse- or fine-grained as the needs of the operator. We report on network function resource requirements in the form of required queue depth and network utilization overhead to inform the decision making against hardware cost constraints.

42 ENGINEERING↗

The energy balance in coronal holes and average quiet-sun regions

Emission measure curves are presented for average coronal hole and quiet-sun spectra taken during the Skylab mission by Vernazza and Reeves (1978), and the curves are used to discuss the energy balance in each region. Close-coupling calculations are used for the Be sequence, assuming a 10 level ion; for B sequence ions mainly distorted wave calculations in an 11 level ion are used, but close-coupling cross sections are used for some ions; for C and Mg sequence ions, distorted wave calculations are used with 15 and 10 level ions, respectively, and close-coupling results are used for Li-like ions with two levels. Results are presented and include the following: the coronal hole spectrum shows a smaller slope in the emission measure distribution, consistent with the expected outflow effects. It is concluded that the simple constant pressure models of static coronal loops of constant cross section are basically able to match the observed emission measure distribution of the average quiet sun between 1,000,000 and 10,000,000 K. However, the cell center and network distributions are respectively steeper and shallower than predicted by the detailed cooling curve.

Raymond, J. C.↗

Postdisaster Routing of Movable Energy Resources for Enhanced Distribution System Resilience: A Deep Reinforcement Learning-Based Approach

The deployment of movable energy resources (MERs) can be an effective strategy to restore critical loads to enhance power system resilience when no other energy sources are available after the occurrence of an extreme event. Since the optimal locations of MERs following an extreme event are dependent on system operating states (e.g., the loads at each node, on/off status of system branches, and so on), existing analytical and population-based approaches must repeat the entire analysis and calculation when the system operating states change. On the contrary, if deep reinforcement learning (DRL)-based algorithms are sufficiently trained with a wide range of scenarios, they can quickly find optimal or near-optimal locations irrespective of changes in system states. A deep Q-learning-based approach is proposed for optimal MER deployment to enhance power system resilience. MERs can be also utilized to complement other types of resources, if available. The proposed approach operates in two stages after the occurrence of extreme events. In the first stage, the distribution network is represented as a graph, and the network is then reconfigured using tie switches by using Kruskal’s spanning forest search algorithm (KSFSA). To maximize critical load recovery, the optimal or near-optimal locations of MERs are chosen in the second stage. Further, case studies on a 33-node distribution system and a modified IEEE 123-node system demonstrate the effectiveness of the proposed approach for postdisaster routing of MERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monte Carlo Dropout Uncertainty Quantification of Long Short-Term Memory Autoencoder Anomaly Detection in a Liquid Sodium Cold Trap

Advanced high-temperature fluid reactors, such as sodium-cooled fast reactors (SFRs) and molten salt–cooled reactors (MSCRs), require coolant purification systems to prevent fluid contamination and local freezing that can lead to plugging. Liquid sodium purification can be achieved with a cold trap, where the sodium temperature is reduced to a near-freezing point to precipitate out impurities. Automation of monitoring of the cold trap performance with machine learning algorithms can aid in early detection of incipient anomalies. An efficient approach to loss-of-coolant–type anomaly detection in a cold trap monitored with more than two dozen thermal-hydraulic sensors consists of a long short-term memory (LSTM) autoencoder. This work develops the uncertainty quantification of the LSTM autoencoder performance for cold trap anomaly detection using the Monte Carlo (MC) dropout method. The MC dropout methodology creates a distribution of sister distributions that all slightly differ from each other because of random neurons being turned off for testing. The variances of the sister network distributions are used to make an uncertainty interval. Our analysis shows that the uncertainty in the autoencoder performance is largest near the peak of the anomaly signal. Using the MC dropout method, we investigate the uncertainty in the anomaly detection with missing sensor inputs. This capability allows the reactor operator to evaluate resilience of the anomaly detection system and to make informed decisions about continuity of operation in the event of sensor failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗