Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Spectrophotometric Determination of Tris(2-Chloroethyl)Amine Using Acid Dyes

Methods of extraction-spectrophotometric determination of tris(2-chloroethyl)amine using nine acid dyes from the groups of sulfonephthaleins, sulfonated anthraquinones, and azo dyes have been developed. These procedures are based on the formation of the ion associates of the reactants and their extraction into chloroform. The conditions of the determination were optimized to determine the optimal pH for extraction from the water phase, the optimal excess of the dye, and the time needed for the extraction. The limits of detection and determination, the molar absorptivities of ion associates, extraction efficiency, distribution ratio, and conditional extraction constants for the separate procedures of determination were calculated. Of the studied acid dyes, the most suitable agents for determining the analyte were bromothymol blue and Acid Blue 129. These procedures are relatively undemanding in terms of time and instruments required and can be applied in field analysis of nitrogen mustards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

General Method for Determining Redox Potentials without Electrolyte

A novel method to determine redox potentials without electrolyte is presented here. The method is based on a new ability to determine the dissociation constant, $K°_d$, for ion pairs formed between any radical anion and any inert electrolyte counterion. These dissociation constants can be used to determine relative shifts of redox potential as a function of electrolyte concentration, connecting referenced potentials determined with electrochemistry (with 0.1 M electrolyte) to electrolyte-free values. Pulse radiolysis created radical anions enabling determination of equilibrium constants for electron transfer between anions of donor and acceptor molecules as a function of electrolyte concentration in THF. The measurements determined “composite equilibrium constants”, $K_{eqC}$, which contain information about the dissociation constant for the electrolyte cations, X + , with the radical anions of both the donor, $K°_d$(D –• ,X + ) and the acceptor, $K°_d$(A –• ,X + ). Dissociation constants were obtained for a selection of radical anions with tetrabutylammonium (TBA + ). The electrolyte was found to shift the reduction potentials of small molecules 1-methylpyrene and trans-stilbene by close to +130 mV whereas oligo-fluorenes and polyfluorenes experienced shifts of only (+25 ± 6) mV due to charge delocalization weakening the ion pair. These shifts for reduction of aromatic hydrocarbon molecules are smaller than shifts of +232 and +451 mV seen previously for benzophenone radical anion with TBA + and Na + respectively where the charge on the radical anion is localized largely on one C=O bond, thus forming a more tightly bound ion pair.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single locus sex determination and female heterogamety in the basket willow ( Salix viminalis L.)

Most eukaryotes reproduce sexually and a wealth of different sex determination mechanisms have evolved in this lineage. Dioecy or separate sexes are rare among flowering plants but have repeatedly evolved from hermaphroditic ancestors possibly involving male or female sterility mutations. Willows (Salix spp.) and poplars (Populus spp.) are predominantly dioecious and are members of the Salicaceae family. All studied poplars have sex determination loci on chromosome XIX, however, the position differs among species and both male and female heterogametic system exists. In contrast to the situation in poplars, knowledge of sex determination mechanisms in willows is sparse. In the present study, we have for the first time positioned the sex determination locus on chromosome XV in S. viminalis using quantitative trait locus mapping. All female offspring carried a maternally inherited haplotype, suggesting a system of female heterogamety or ZW. We used a comparative mapping approach and compared the positions of the markers between the S. viminalis linkage map and the physical maps of S. purpurea, S. suchowensis and P. trichocarpa. As we found no evidence for chromosomal rearrangements between chromosome XV and XIX between S. viminalis and P. trichocarpa, it shows that the sex determination loci in the willow and the poplar most likely do not share a common origin and has thus evolved separately. This demonstrates that sex determination mechanisms in the Salicaceae family have a high turnover rate and as such it is excellent for studies of evolutionary processes involved in sex chromosome turnover.

59 BASIC BIOLOGICAL SCIENCES↗

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MODEL-INDEPENDENT X-RAY MASS DETERMINATIONS

A new method is introduced for making X-ray mass determinations of spherical clusters of galaxies. Treating the distribution of gravitating matter as piecewise constant and the cluster atmosphere as piecewise isothermal, X-ray spectra of a hydrostatic atmosphere are determined up to a single overall normalizing factor. In contrast to more conventional approaches, this method relies on the minimum of assumptions, apart from the conditions of hydrostatic equilibrium and spherical symmetry. The method has been implemented as an XSPEC mixing model called CLMASS, which was used to determine masses for a sample of nine relaxed X-ray clusters. Compared to conventional mass determinations, CLMASS provides weak constraints on values of M{sub 500}, reflecting the quality of current X-ray data for cluster regions beyond r{sub 500}. At smaller radii, where there are high quality X-ray spectra inside and outside the radius of interest to constrain the mass, CLMASS gives confidence ranges for M{sub 2500} that are only moderately less restrictive than those from more familiar mass determination methods. The CLMASS model provides some advantages over other methods and should prove useful for mass determinations in regions where there are high quality X-ray data.

79 ASTRONOMY AND ASTROPHYSICS↗

A new approach to systematic uncertainties and self-consistency in helium abundance determinations

Tests of big bang nucleosynthesis and early universe cosmology require precision measurements for helium abundance determinations. However, efforts to determine the primordial helium abundance via observations of metal poor H II regions have been limited by significant uncertainties (compared with the value inferred from BBN theory using the CMB determined value of the baryon density). This work builds upon previous work by providing an updated and extended program in evaluating these uncertainties. Procedural consistency is achieved by integrating the hydrogen based reddening correction with the helium based abundance calculation, i.e., all physical parameters are solved for simultaneously. We include new atomic data for helium recombination and collisional emission based upon recent work by Porter \etal and wavelength dependent corrections to underlying absorption are investigated. The set of physical parameters has been expanded here to include the effects of neutral hydrogen collisional emission. It is noted that Hγ and Hδ allow better isolation of the collisional effects from the reddening. Because of a degeneracy between the solutions for density and temperature, the precision of the helium abundance determinations is limited. Also, at lower temperatures (T ∼< 13,000 K) the neutral hydrogen fraction is poorly constrained resulting in a larger uncertainty in the helium abundances. Thus, the derived errors on the helium abundances for individual objects are larger than those typical of previous studies. Seven previously analyzed, ''high quality'' H II region spectra are used for a primordial helium abundance determination. The updated emissivities and neutral hydrogen correction generally raise the abundance. From a regression to zero metallicity, we find Y{sub p} as 0.2561 ± 0.0108, in broad agreement with the WMAP result. Alternatively, a simple average of the data yields Y{sub p} 0.2566 ± 0.0028. Tests with synthetic data show a potential for distinct improvement, via removal of underlying absorption, using higher resolution spectra. A small bias in the abundance determination can be reduced significantly and the calculated helium abundance error can be reduced by ∼ 25%.

79 ASTRONOMY AND ASTROPHYSICS↗

A neural network for determination of latent dimensionality in Nonnegative Matrix Factorization

Non-negative Matrix Factorization (NMF) has proven to be a powerful unsupervised learning method for uncovering hidden features in complex and noisy datasets with applications in data mining, text recognition, dimension reduction, face recognition, anomaly detection, blind source separation, and many other fields. An important input for NMF is the latent dimensionality of the data, that is, the number of hidden features, K, present in the explored dataset. Unfortunately, and this quantity is rarely known a priori. The existing methods for determining latent dimensionality, such as Automatic Relevance Determination (ARD), are mostly heuristic and utilize different characteristics to estimate the number of hidden features. However, all of them require human presence to make a final determination of K. Here we utilize a supervised machine learning approach in combination with a recent method for model determination, called NMFk, to determine the number of hidden features automatically. NMFk performs a set of NMF simulations on an ensemble of matrices, obtained by bootstrapping the initial dataset, and estimates which K produces stable groups of latent features that reconstruct the initial dataset well. We then train a Multi-Layter Perceptron (MLP) classifier network to determine the correct number of latent features utilizing the statistics and characteristics of the NMF solution, obtained from NMFk. In order to train the MLP classifier, a training set of 58,660 matrices with predetermined latent features were factorized with NMFk. The MLP classifier in conjunction with NMFk maintains a greater than 95% success rate when applied to a held out test set. Additionally, when applied to two well-known benchmark datasets, the swimmer and MIT face data, NMFk/MLP correctly recovers the established number of hidden features. Finally, we compare the accuracy of our method to the ARD, AIC and Stability-based methods.

97 MATHEMATICS AND COMPUTING↗

A procedure to determine the planar integral spot dose values of proton pencil beam spots

Purpose: Planar integral spot dose (PISD) of proton pencil beam spots (PPBSs) is a required input parameter for beam modeling in some treatment planning systems used in proton therapy clinics. The measurement of PISD by using commercially available large area ionization chambers, like the PTW Bragg peak chamber (BPC), can have large uncertainties due to the size limitation of these chambers. This paper reports the results of our study of a novel method to determine PISD values from the measured lateral dose profiles and peak dose of the PPBS. Methods: The PISDs of 72.5, 89.6, 146.9, 181.1, and 221.8 MeV energy PPBSs were determined by area integration of their planar dose distributions at different depths in water. The lateral relative dose profiles of the PPBSs at selected depths were measured by using small volume ion chambers and were investigated for their angular anisotropies using Kodak XV films. The peak spot dose along the beam's central axis (D{sub 0}) was determined by placing a small volume ion chamber at the center of a broad field created by the superposition of spots at different locations. This method allows eliminating positioning uncertainties and the detector size effect that could occur when measuring it in single PPBS. The PISD was then calculated by integrating the measured lateral relative dose profiles for two different upper limits of integration and then multiplying it with corresponding D{sub 0}. The first limit of integration was set to radius of the BPC, namely 4.08 cm, giving PISD{sub RBPC}. The second limit was set to a value of the radial distance where the profile dose falls below 0.1% of the peak giving the PISD{sub full}. The calculated values of PISD{sub RBPC} obtained from area integration method were compared with the BPC measured values. Long tail dose correction factors (LTDCFs) were determined from the ratio of PISD{sub full}/PISD{sub RBPC} at different depths for PPBSs of different energies. Results: The spot profiles were found to have angular anisotropy. This anisotropy in PPBS dose distribution could be accounted in a reasonable approximate manner by taking the average of PISD values obtained using the in-line and cross-line profiles. The PISD{sub RBPC} values fall within 3.5% of those measured by BPC. Due to inherent dosimetry challenges associated with PPBS dosimetry, which can lead to large experimental uncertainties, such an agreement is considered to be satisfactory for validation purposes. The PISD{sub full} values show differences ranging from 1 to 11% from BPC measured values, which are mainly due to the size limitation of the BPC to account for the dose in the long tail regions of the spots extending beyond its 4.08 cm radius. The dose in long tail regions occur both for high energy beams such as 221.8 MeV PPBS due to the contributions of nuclear interactions products in the medium, and for low energy PPBS because of their larger spot sizes. The calculated LTDCF values agree within 1% with those determined by the Monte Carlo (MC) simulations. Conclusions: The area integration method to compute the PISD from PPBS lateral dose profiles is found to be useful both to determine the correction factors for the values measured by the BPC and to validate the results from MC simulations.

43 PARTICLE ACCELERATORS↗

TU-FG-BRB-02: The Impact of Using Dual-Energy CT for Determining Proton Stopping Powers: Comparison Between Theory and Experiments

Purpose: To evaluate the clinical performance of dual-energy CT (DECT) in determining proton stopping power ratios (SPR) and demonstrate advantages over conventional single-energy CT (SECT). Methods: SECT and DECT scans of tissue-equivalent plastics as well as animal meat samples are performed with a Siemens SOMATOM Definition Flash. The methods of Schneider et al. (1996) and Bourque et al. (2014) are used to determine proton SPR on SECT and DECT images, respectively. Waterequivalent path length (WEPL) measurements of plastics and tissue samples are performed with a 195 MeV proton beam. WEPL values are determined experimentally using the depth-dose shift and dose extinction methods. Results: Comparison between CT-based and experimental WEPL is performed for 12 tissue-equivalent plastic as well as 6 meat boxes containing animal liver, kidney, heart, stomach, muscle and bones. For plastic materials, results show a systematic improvement in determining SPR with DECT, with a mean absolute error of 0.4% compared to 1.7% for SECT. For the meat samples, preliminary results show the ability for DECT to determine WEPL with a mean absolute value of 1.1% over all meat boxes. Conclusion: This work demonstrates the potential in using DECT for determining proton SPR with plastic materials in a clinical context. Further work is required to show the benefits of DECT for tissue samples. While experimental uncertainties could be a limiting factor to show the benefits of DECT over SECT for the meat samples, further work is required to adapt the DECT formalism in the context of clinical use, where noise and artifacts play an important role.

07 ISOTOPE AND RADIATION SOURCES↗

Q-value (MeV/fission) Determination for the Advanced Test Reactor

This report documents a step-by-step procedure that can be used to calculate a Q-value for the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The Q-value calculation here is an estimate of the total energy released per fission event in the ATR driver fuel in units of MeV/fission and is recognized as a reactor-specific Q-value for the ATR. Such a Q-value is needed INL ATR reactor physicists to normalize calculated fluxes and reaction rates to measured ATR total core and lobe powers. The calculated ATR Q-value and the procedure used to calculate this value are presented in a detailed manner so as to establish a credible basis, such that this single Q-value can be used consistently among all ATR reactor physicists. A Q-value is essentially the summation of all the kinetic energy from all radiation components released from a single fission event that ends up as heat in the reactor coolant. Estimation of a Q-value for a given reactor can theoretically be very complex because it is dependent on several variables, which include (1) the materials in the reactor core, (2) the neutron energy spectrum, and (3) the mix of actinide isotopes that are being simultaneously fissioned. Since these three variables can potentially change over time or with reactor burnup, this potentially makes the Q-value a time-dependent quantity. However, for ATR, we will invoke some simplifying assumptions, based on the unique features of the ATR core and supported by neutronic calculations, which will reduce the complexity of the problem and lead to a single time-independent Q-value. Of the three variables, the materials in the core have the greatest impact on the ATR Q-value. Since the materials in the core are most important, an array of components (materials) have been carefully selected to compose a typical ATR core configuration. It should be noted that the step-by-step procedure here for calculating a reactor-specific Q-value can be applied to any nuclear reactor. In a more general procedure, if one needed to include time-dependent spectral and actinide composition changes as a function of burnup for a specific reactor, this procedure can still be used, but at discrete time steps throughout the burnup. The result will be a set of discrete Q-values as a function of burnup. However, here we will apply the procedure to the ATR, as an example, and obtain a single Q-value that is valid for the ATR reactor as a function of burnup. In the evaluated nuclear data file (ENDF), Q-values for specific actinides are known for a reasonably high degree of accuracy, especially the major uranium and plutonium isotopes. The isotopic Q-values are composed of the kinetic energy of the fission fragments and the energies of the various radiation components emitted from the fission event. One complication is the fact that some of these energy components are dependent on the incident neutron energy (EINC) that induces the fission event (neutron energy spectrum dependence). For ATR, we will estimate an average neutron energy based on the neutron energy flux weighted by the fission cross sections and use this average neutron energy value in the ENDF formulas. This neutron energy dependence is one of two dependencies that make the final ATR Q-value a reactor-specific value. The second dependency, and the most important variable for ATR, involves the materials in the core and the de-excitation radiations produced from neutron radiative capture radiation; radiation energy that becomes heat in the reactor coolant. This important dependency is discussed in detail below. The third dependency, or the mix of fissioning actinides as a function of ATR burnup, is ignored because the bulk of the fissions over a cycle are always due to U-235 in the high-enriched ATR core. In a fission event, the fission energy is partitioned between the fission fragments and the radiation components that include neutrons, gamma rays, and beta particles. The main variable that makes the calculated Q-value reactor-specific is the amount of radiative capture energy produced in the core due to prompt and delayed neutron capture in the reactor core materials and the subsequent release of nuclear binding energy in the form of de-excitation gamma radiation energy in the reactor core. This energy component, neutron radiative capture energy, is not in the ENDF, because it depends on the reactor and its core materials. The radiative capture gamma energy release can be significant, or approximately 3–12 MeV/fission depending on the materials in the reactor core (fuel materials, cladding, structural components, coolant, targets, reflector, etc.). For the ATR, the energy released from radiative capture gamma radiation is calculated to be near the middle of the 3–12 MeV range. This makes the radiative capture radiation component an important and significant contribution to the total ATR Q-value. The ATR has unique reactor features that will allow us to simplify the complex procedure for determining an ATR reactor-specific Q-value. For example, the ATR is a thermal reactor and contains high-enriched fuel (93.15 wt% U-235). Consequently, the bulk of the fissions in the ATR core from beginning-of-cycle (BOC) to end-of-cycle are from U-235. Even though U-238 makes up approximately 7% of the uranium atoms in the fuel, the number of fissions relative to U-235 is insignificant, since U-238 is fertile and ATR is a thermal reactor. The same is true for U-234 and U-236 (both fertile). The ATR’s high-enriched uranium fuel also inhibits the buildup of large quantities of plutonium isotopes. So, even though there is some buildup of U-236, Np-237, and Pu-239 in the ATR driver fuel, the impact or contribution of these isotopes fissions on the ATR Q-value is minor compared to U-235. Nonetheless, we will include fission contributions from all the major uranium isotopes (U-234, U-235, U-236, and U-238) in the determination of an average isotopic Q-value that is used in the ATR Q-value determination. Although the ATR Q-value calculated here is based on BOC conditions (fresh fuel with no higher order actinide buildup), it is believed that the ATR Q-value is relatively constant with burnup or during any given ATR power cycle (14–60 days). The reason is that the vast majority of the core driver fuel fissions are always from U-235 during the cycle. Also, since we effectively assume instantaneous energy release for the fission product gammas and beta particles and delayed neutrons from a fission event, this corresponds to equilibrium conditions for all fission product concentrations in the ATR driver fuel too. The goal of this effort was to determine a specific numerical and core-average Q-value for the recoverable energy released by a single fission event (MeV/fission) for the ATR. This calculated value has the potential to help standardize and add credibility to not only the Monte Carlo tally normalization process used by many ATR core physics analysts, but also to the normalization process for all reactor physics calculation methods involving ATR analyses. Currently, the ATR core physics analysts use slightly different Q-values. Some values are known to be conservative for specific applications. However, sometimes a more accurate Q-value is needed for the calculation in which ATR test specimens require non-conservative and as-accurate-as-possible Q-values to estimate burnups, heat rates, neutron fluxes, nuclear reaction rates, etc., where corresponding measured post-irradiation examination data provides the ultimate validation for the calculated results. A detailed Q-value procedure was developed and is outlined in this document along with numerical values calculated specifically for the determination of the ATR Q-value. This report attempts to document in some detail the calculation methodology, nuclear data, computer code, computer model, code calculated results, hand calculations, assumptions, and logic that went into the determination of the ATR Q-value.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Holistic Framework for Environmental Flows Determination in Hydropower Contexts

Among the ecological science community, the consensus view is that the natural flow regime sustains the ecological integrity of river systems. This prevailing viewpoint by many environmental stakeholders has progressively led to increased pressure on hydropower dam owners to change plant operations to affect downstream river flows with the intention of providing better conditions for aquatic biological communities. Identifying the neccessary magnitude, frequency, duration, timing, or rate of change of stream flows to meet ecological needs in a hydropower context is challenging because the ecological responses to changes in flows may not be fully known, there are usually a multitude of competing users of flow, and implementing environmental flows usually comes at a price to energy production. Realistically, hydropower managers must develop a reduced set of goals that provide the most benefit to the identified ecological needs. As a part of the Department of Energy (DOE) Water Power Program, the Instream Flow Project (IFP) was carried out by Oak Ridge National Laboratory (ORNL), Pacific Northwest National Laboratory (PNNL), and Argon National Laboratory (ANL) as an attempt to develop tools aimed at defining environmental flow needs for hydropower operations. The application of these tools ranges from national to site-specific scales; thus, the utility of each tool will depend on various phases of the environmental flow process. Given the complexity and sheer volume of applications used to determine environmentally acceptable flows for hydropower, a framework is needed to organize efforts into a staged process dependent upon spatial, temporal, and functional attributes. By far, the predominant domain for determining environmental flows related to hydropower is within the Federal Energy Regulatory Commission (FERC) relicensing process. This process can take multiple years and can be very expensive depending on the scale of each hydropower project. The utility of such a framework is that it can expedite the environmental flow process by 1) organizing data and applications to identify predictable relationships between flows and ecology, and 2) suggesting when and where tools should be used in the environmental flow process. In addition to regulatory procedures, a framework should also provide the coordination for a comprehensive research agenda to guide the science of environmental flows. This research program has further reaching benefits than just environmental flow determination by providing modeling applications, data, and geospatial layers to inform potential hydropower development. We address several objectives within this document that highlight the limitations of existing environmental flow paradigms and their applications to hydropower while presenting a new framework catered towards hydropower needs. Herein, we address the following objectives: 1) Provide a brief overview of the Natural Flow Regime paradigm and existing environmental flow frameworks that have been used to determine ecologically sensitive stream flows for hydropower operations. 2) Describe a new conceptual framework to aid in determining flows needed to meet ecological objectives with regard to hydropower operations. The framework is centralized around determining predictable relationships between flow and ecological responses. 3) Provide evidence of how efforts from ORNL, PNNL, and ANL have filled some of the gaps in this broader framework, and suggest how the framework can be used to set the stage for a research agenda for environmental flow.

dams↗

Groundwater Potability Determination Report for Sylvan Grove, Kansas

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility from 1954 to 1966 at the northeastern edge of Sylvan Grove, Kansas (Figures 1.1 and 1.2). During this time, commercial grain fumigants containing carbon tetrachloride were in common use to preserve grain in storage. The CCC/USDA is in the process of preparing a Corrective Action Study (CAS) to address carbon tetrachloride contamination in groundwater on the portion of the site that it formerly leased and operated. As stated in the Kansas Department of Health and Environment (KDHE) Bureau of Environmental Remediation (BER) policy BER-RS-045 (KDHE 2016), Considerations for Groundwater Potability and Use Determinations (hereafter referred to as “Potability Determination Guidance”), the KDHE considers all groundwater to be a potential source of potable water. This report, however, substantiates that groundwater resources in the Cretaceous Dakota Formation—more specifically, that localized portions of water bearing strata affected by operations at the former CCC/USDA site—are non-potable. The purpose of this report, therefore, is to provide additional information to support the KDHE’s decision-making process with regard to the disposition and closure of the Sylvan Grove site. Per the Potability Determination Guidance the results of this potability evaluation will play a role in selecting the site remedial action objectives and the overall proposed path for long-term management. This report presents the data and analyses of the potability study and the results of the potability determination, which will be taken into consideration during the development of cleanup goals for the CAS or for any other future remedial or long-term management action agreed to by the CCC/USDA and KDHE. The Potability Determination Guidance provides a framework to evaluate groundwater potability by outlining: The set of threshold criteria under which KDHE will consider an aquifer to be non-potable; The data and information necessary to evaluate potability; and, Considerations for long-term management of aquifers that are deemed non potable. According to the guidance, the KDHE may determine that groundwater is non-potable due to natural conditions such as water quality or quantity characteristics. As suggested in the guidance, this report will discuss the initial potability threshold screening for entering the evaluation process (Section 2); justify the work plan that was covered by the site investigation planning (also in Section 2); and present the relevant data and evaluation results (Sections 3-6).

54 ENVIRONMENTAL SCIENCES↗

Spectroscopic Determination of Stellar Parameters and Oxygen Abundances for Hyades/Field G–K Dwarfs

It has been suggested that Fe abundances of K dwarfs derived from Fe i and Fe ii lines show considerable discrepancies, and oxygen abundances determined from high-excitation O i 7771–5 triplet lines are appreciably overestimated (the problem becoming more serious toward lower T {sub eff}), which, however, has not yet been widely confirmed. With the aim of clarifying this issue, we spectroscopically determined the atmospheric parameters of 148 G–K dwarfs (Hyades cluster stars and field stars) by assuming the classical Fe i/Fe ii ionization equilibrium as usual, and determined their oxygen abundances by applying the non-local thermal equilibrium spectrum fitting analysis to O i 7771–5 lines. It turned out that the resulting parameters did not show any significant inconsistency with those determined by other methods (for example, the mean differences in T {sub eff} and logg from the well-determined solutions of Hyades dwarfs are mostly ≲100 K and ≲0.1 dex). Likewise, the oxygen abundances of Hyades stars are around [O/H] ∼ +0.2 dex (consistent with the metallicity of this cluster) without exhibiting any systematic T {sub eff}-dependence. Accordingly, we conclude that parameters can be spectroscopically evaluated to a sufficient precision in the conventional manner (based on the Saha–Boltzmann equation for Fe i/Fe ii) and oxygen abundances can be reliably determined from the O i 7771–5 triplet for K dwarfs as far as stars of T {sub eff} ≳ 4500 K are concerned. We suspect that previously reported strongly T {sub eff}-dependent discrepancies may have stemmed mainly from overestimation of weak-line strengths and/or improper T {sub eff} scale.

79 ASTRONOMY AND ASTROPHYSICS↗

Lander Locations, Mars Physical Ephemeris, and Solar System Parameters: Determination from Viking Lander Tracking Data

Radio tracking data from the Viking landers have been analyzed to determine the parameters of the Mars physical ephemeris, the radii of Mars at the landing sites, and the lander locations. The orientation of the Mars rotation axis, referred to the 1950.0 earth mean equator, equinox, and epoch, was determined to be 317.340+/-0.003 degrees right ascension and 52.710+/-0.002degrees declination. The planet's rotation period was determined to be 24 h, 37 min, 22.663+/-0.002 s. Analyses indicate that the determination of the motions of the Mars rotation axis will require additional tracking data. The Mars radii at the sites of landers 1 and 2 are 3389.38+/-0.06 km and 3381.91+/-0.08 km, respectively. The areocentric location of lander 1 is 22.272+/-0.002 degrees N, 47.94+/-0.2 degrees W. The lander 2 location is 47.670+/-0.002 degrees N, 225.71+/-0.2 degrees W. The areocentric right ascensions of the landers are determined to be 277.314+/-0.002 degrees for lander 1 and 99.546+/-0.002degrees for lander 2 at 0000 hours, January 1, 1977 (Julian date 2443144.57). Possible determinations of relativity parameters, solar oblateness, asteroid mass, and variations of the universal gravitational constant, from their effects on the planetary motions, will require the additional tracking data of the Viking extended mission.

Mayo, A. P.↗

Precision attitude determination for multimission spacecraft

Attitude determination algorithms for a multimission spacecraft are derived and their performance analyzed. The attitude determination system is composed of a strapdown Inertial Reference Unit (IRU), two fixed head star trackers, and an onboard computer. IRU data is processed to maintain real-time knowledge of spacecraft attitude relative to an inertial reference frame. Star tracker data is processed using Kalman filtering techniques to estimate and correct the attitude determination errors and the gyro drift compensation errors. The results of a star availability analysis for stellar, solar and earth pointing missions are presented. Linear covariance analysis techniques are used to evaluate nominal attitude determination performance, the effects of sensor measurement accuracy variations, the effects of errors in knowledge of sensor measurement accuracy, and the effects of star tracker misalignment errors. Results of a nonlinear simulation analysis of attitude determination performance are also presented. These analyses show that precision attitude determination for stellar, solar and earth pointing missions is achieved.

Murrell, J. W.↗

Feasibility of determining flat roof heat losses using aerial thermography

The utility of aerial thermography for determining rooftop heat losses was investigated experimentally using several completely instrumented test roofs with known thermal resistances. Actual rooftop heat losses were obtained both from in-situ instrumentation and aerial thermography obtained from overflights at an altitude of 305 m. In general, the remotely determined roof surface temperatures agreed very well with those obtained from ground measurements. The roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from 1/R delta T using ground measurements. However, this agreement may be fortuitous since the convective component of the heat loss is sensitive to small changes in roof temperature and to the average heat transfer coefficient used, whereas the radiative component is less sensitive. This, at this time, it is felt that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. The sensitivity of the heat loss determination to environmental conditions was also evaluated. The analysis showed that the most reliable quantitative heat loss determinations can probably be obtained from aerial thermography taken under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

Bowman, R. L.↗

An approach to autonomous, onboard orbit determination

An orbit determination subsystem that will operate as an integral part of an autonomous, onboard navigation system is presented and analyzed. The navigation system is required to interface solely with the downlink telemetry stream and uplink command stream of an existing class of geostationary satellites. In particular, the orbit will be determined from a set of onboard sensors, which previously were used only for attitude determination. The design of the orbit determination subsystem is described in detail. The rationale behind the choice of each component of the design is given. Finally, the performance of the orbit determination subsystem, under a variety of assumptions, is determined by a combination of numerical simulation and analytical methods.

Mease, K. D.↗

Determination of lifetime and surface recombination velocity of p-n junction solar cells and diodes by observing transients

The unified view of transient methods for the determination of recombination lifetime tau and back surface recombination velocity S presented here for silicon solar cells and diodes attempts to define limitations of existing methods and to evolve improvements. The presence of sizable junction capacitance for silicon devices under forward voltage invalidates the use of conventional open-circuit voltage decay (OCVD) and reverse recovery. This led Green (1983) to his method of compensated open-circuit voltage decay, in which the addition of an external resistor shunting the solar cell partially corrects for the presence of the junction capacitance. Setting this resistance to zero produces an electrical short-circuit current-decay method, which has the advantage of enabling determination of both tau and S. In an alternate approach, one may insert the functional dependence of the junction capacitance on forward voltage. This new method, denoted by the acronym OCVDCAP, enables the determination of tau with apparently greater accuracy than that obtained by previous methods utilizing voltage transients. But OCVDCAP has in common with the previous methods that it determines tau only and has practical utility only for determining tau of long-base devices. This means that it is useful only for thick base regions. In principle, however, it has an advantage over short-circuit current decay: it requires only pressure contacts, not ohmic contacts, and therefore may be used to determine tau after key processing steps in manufacturing.

Lindholm, Fredrik A.↗