At least 415 records · Page 23

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Additionally, key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New results from the CUORE experiment

We report that the Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrino-less double-beta (0vββ) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its second result of the search for 0vββ corresponding to a TeO 2 exposure of 372.5 kg∙yr and a median exclusion sensitivity to a 130 Te 0vββ decay half-life of 1.7 ∙ 10 25 yr. We find no evidence for 0vββ decay and set a 90% C.I. Bayesian lower limit of 3.2 ∙ 10 25 yr on the 130 Te 0vββ decay half-life. We present the current status of CUORE’s search for 0vββ. We give an update of the CUORE background model and the measurement of the 130 Te two neutrino double-beta (2vββ) decay half-life. Eventually, we show the preliminary results on half-life limits from the analysis of 130 Te 0vββ and 2vββ decay to the first 0 + excited state of 130 Xe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0\nu\beta\beta$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0\nu\beta\beta$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0\nu\beta\beta$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0\nu\beta\beta$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0\nu\beta\beta$ decay half-life. In this work, we present the current status of CUORE's search for $0\nu\beta\beta$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2\nu\beta\beta$) decay half-life.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of the SPT-SLIM Focal Plane: A Spectroscopic Imaging Array for the South Pole Telescope

The Summertime Line Intensity Mapper (SLIM) is a mm-wave line-intensity mapping (mm-LIM) experiment for the South Pole Telescope (SPT). The goal of SPT-SLIM is to serve as a technical and scientific pathfinder for the demonstration of the suitability and in-field performance of multi-pixel superconducting filterbank spectrometers for future mm-LIM experiments. Scheduled to deploy in the 2023-24 austral summer, the SPT-SLIM focal plane will include 18 dual-polarisation pixels, each coupled to an $R = \lambda / \Delta \lambda = 300$ thin-film microstrip filterbank spectrometer that spans the 2 mm atmospheric window (120–180 GHz). Each individual spectral channel feeds a microstrip-coupled lumped-element kinetic inductance detector, which provides the highly multiplexed readout for the 10k detectors needed for SPT-SLIM. Here, we present an overview of the preliminary design of key aspects of the SPT-SLIM focal plane array, a description of the detector architecture and predicted performance, and initial test results that will be used to inform the final design of the SPT-SLIM spectrometer array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Models of ultraheavy dark matter visible to macroscopic mechanical sensing arrays

In recent years, the sensitivity of optomechanical force sensors has improved leading to increased interest in using these devices as particle detectors. In this study we consider scenarios where dark matter with mass close to the Planck scale may be probed by a large array of optomechanical accelerometers. We motivate a macroscopic mechanical search for ultraheavy dark matter, exemplified by the efforts of the Windchime Collaboration, by providing a survey of the model space that would be visible to such a search. We consider two classes of models, one that invokes a new long-range unscreened force and another that is only gravitationally interacting. We identify significant regions of well-motivated, potentially visible parameter space for versatile models such as Q-balls, composite dark matter, relics of gravitational singularities, and gravitationally produced ultraheavy particles.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm 3 . The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80 %), while those evaluated using the minimum squared difference method (55-59 %) and Three Compton method (45-55 %) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seismic Imaging of the Mw 7.1 Ridgecrest Earthquake Rupture Zone From Data Recorded by Dense Linear Arrays

Abstract We analyze seismograms recorded by four arrays (B1–B4) with 100 m station spacing and apertures of 4–8 km that cross the surface rupture of the 2019 Mw 7.1 Ridgecrest earthquake. The arrays extend from B1 in the northwest to B4 in the southeast of the surface rupture. Delay times between P wave arrivals associated with ∼1,200 local earthquakes and four teleseismic events are used to estimate local velocity variations beneath the arrays. Both teleseismic and local P waves travel faster on the northeast than the southwest side of the fault beneath arrays B1 and B4, but the velocity contrast is less reliably resolved at arrays B2 and B3. We identify several 1–2 km wide low‐velocity zones with much slower inner cores that amplify S waveforms, inferred as damage zones, beneath each array. The damage zones at arrays B2 and B4 also generate fault‐zone head and trapped waves. An automated detector, based on peak ground velocities and durations of high‐amplitude waves, identifies candidate fault‐zone trapped waves (FZTWs) in a localized zone for ∼600 earthquakes at array B4. Synthetic waveform modeling of averaged FZTWs, generated by ∼30 events with high‐quality signals, indicates that the trapping structure at array B4 has a width of ∼300 m, depth of 3–5 km, S wave velocity reduction of ∼20% with respect to the surrounding rock, Q ‐value of ∼30, and S wave velocity contrast of ∼4% across the fault (faster on the northeast side). The results show complex fault‐zone internal structures (velocity contrasts and low‐velocity zones) that vary along fault strike.

Qiu, Hongrui↗

Auger@TA: In-situ Cross-Calibration of the World's Largest Cosmic Ray Observatories

The Pierre Auger Observatory (Auger) and the Telescope Array (TA) are the world's two largest ultra-high-energy cosmic ray (UHECR) observatories. They operate in the Southern and Northern hemispheres, respectively, at similar latitudes but with distinct surface detector (SD) designs. A significant challenge in studying UHECR physics across the full sky is the apparent discrepancy in flux measurements between the two experiments. This discrepancy could arise from astrophysical differences and/or systematic effects related to their detector designs and sensitivities to extensive air shower components. To address this, the Auger@TA working group aims to cross-calibrate the two observatories with a self-triggering micro-Auger array within the TA array. This micro-array consists of eight Auger Surface Detector (SD) stations equipped with Water Cherenkov Detectors (WCDs) and AugerPrime Surface Scintillator Detectors. Seven SD stations, configured with a centered-1-PMT design, are arranged in a hexagonal pattern with one station in the center, with 1.5 km spacing, mirroring the Auger layout. The eighth station, which features a standard 3-PMT Auger station, is located in conjunction with a TA detector at the center of the hexagon, forming a triplet for high-statistics and low-uncertainty cross-calibration. A custom communication system that uses readily available components enables seamless communication between stations and remote access to each station through a central computer. The micro-array is now fully deployed, and initial data-taking is about to start. This presentation will detail the instrumentation, communication systems, central data acquisition system, expected performance of the micro-array, and preliminary results as appropriate.

Mocellin, Adriel G.B. [Colorado School of Mines]↗

Physics potential of the IceCube Upgrade for atmospheric neutrino oscillations

The IceCube Upgrade is an extension of the existing IceCube Neutrino Observatory and will be deployed in the 2025–2026 austral summer. It will significantly improve the sensitivity of the detector to atmospheric neutrino oscillations. The existing 86-string IceCube array contains a dense in-fill known as DeepCore which is optimized to measure neutrinos with energies down to a few GeV. The IceCube Upgrade will consist of seven new densely instrumented strings placed within the DeepCore volume to further enhance the performance in the GeV energy range. The additional strings will feature new optical modules, each containing multiple photomultiplier tubes (PMTs), in contrast to the existing modules that each contain a single PMT. This will more than triple the number of PMT channels with respect to the current IceCube configuration, allowing for improved detection efficiency and reconstruction performance at GeV energies. We describe necessary updates to simulation, event selection, and reconstruction to accommodate the higher data rates observed by the upgraded detector and the addition of multi-PMT modules. We determine the expected sensitivity of the IceCube Upgrade to the atmospheric neutrino oscillation parameters sin 2 ⁡𝜃 23 and Δ⁢𝑚$^{2}_{32}$, the appearance of tau neutrinos and the neutrino mass ordering. The IceCube Upgrade will provide neutrino oscillation measurements that are of similar precision to those from accelerator experiments, while providing complementarity by probing higher energies and longer baselines, and with different sources of systematic uncertainties.

artificial neural networks↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.

36 MATERIALS SCIENCE↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

Combined dark matter search towards dwarf spheroidal galaxies with Fermi -LAT, HAWC, H.E.S.S., MAGIC, and VERITAS

Dwarf spheroidal galaxies (dSphs) are excellent targets for indirect dark matter (DM) searches using gamma-ray telescopes because they are thought to have high DM content and a low astrophysical background. The sensitivity of these searches is improved by combining the observations of dSphs made by different gamma-ray telescopes. We present the results of a combined search by the most sensitive currently operating gamma-ray telescopes, namely: the satellite-borne Fermi -LAT telescope; the ground-based imaging atmospheric Cherenkov telescope arrays H.E.S.S., MAGIC, and VERITAS; and the HAWC water Cherenkov detector. Individual datasets were analyzed using a common statistical approach. Results were subsequently combined via a global joint likelihood analysis. We obtain constraints on the velocity-weighted cross section 〈σv〉 for DM self-annihilation as a function of the DM particle mass. This five-instrument combination allows the derivation of up to 2-3 times more constraining upper limits on 〈σv〉 than the individual results over a wide mass range spanning from 5 GeV to 100 TeV. Depending on the DM content modeling, the 95% confidence level observed limits reach 1.5×10 -24 cm 3 s -1 and 3.2×10 -25 cm 3 s -1 , respectively, in the τ + τ - annihilation channel for a DM mass of 2 TeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Birefringence tests of gravity with multimessenger binaries

Extensions to General Relativity (GR) allow the polarization of gravitational waves (GW) from astrophysical sources to suffer from amplitude and velocity birefringence, which respectively induce changes in the ellipticity and orientation of the polarization tensor. Here, we introduce a multi-messenger approach to test this polarization behavior of GWs during their cosmological propagation using binary sources, for which the initial polarization is determined by the inclination and orientation angles of the orbital angular momentum vector with respect to the line of sight. In particular, we use spatially resolved radio imaging of the jet from a binary neutron star (BNS) merger to constrain the orientation angle and hence the emitted polarization orientation of the GW signal at the site of the merger, and compare to that observed on Earth by GW detectors. For GW170817, using past measurements of the inclination angle, we constrain the deviation from GR due to amplitude birefringence to κ A = $-0.12^{+0.60}_ {-0.61}$, while the velocity birefringence parameter κ V remains unconstrained. The inability to constrain κ V is due to the low amplitude of GW170817 in the Virgo detector, and measurements of the polarization orientation require information from a combination of multiple detectors with different alignments. For this reason, we also mock future BNS mergers with resolved afterglow proper motion and project that κ V could be constrained to a precision of 5 rad (corresponding to an angular shift of the GW polarization of δ φV ≈ 0.2 rad for a BNS at 100 Mpc) by a future network of third-generation ground-based GW detectors such as Cosmic Explorer and the radio High Sensitivity Array. Crucially, this velocity birefringence effect cannot be constrained with dark binary mergers as it requires polarization information at the emission time, which can be provided only by electromagnetic emission.

79 ASTRONOMY AND ASTROPHYSICS↗