Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Analysis of Warped April Tag Impacts on Detection and Pose Estimation

This report evaluates the impact of geometric deformation on an April Tag, particularly when warped due to attachment on a curved surface, on its detectability and pose estimation performance. A comparative analysis was conducted using a flat April Tag as a control under identical experimental conditions, which involved recording video sequences with varying viewing angles. For detectability, the warped tag exhibited consistent detection failures at viewing angles beyond 40° and complete failures beyond 60°, whereas the flat tag maintained reliable detection across all angles. For pose estimation, measured by pose jitter (variation in rotation and translation), differences between the warped and flat tags were minimal and statistically insignificant, indicating robust performance even for the deformed tag. These findings suggest that while geometric warping reduces an April Tag’s detectability, its pose estimation accuracy remains relatively unaffected under the tested conditions.

42 ENGINEERING↗

Improving Detection of Disease Re-emergence Using a Web-Based Tool (RED Alert): Design and Case Analysis Study

Background: Currently, the identification of infectious disease re-emergence is performed without describing specific quantitative criteria that can be used to identify re-emergence events consistently. This practice may lead to ineffective mitigation. In addition, identification of factors contributing to local disease re-emergence and assessment of global disease re-emergence require access to data about disease incidence and a large number of factors at the local level for the entire world. This paper presents Re-emerging Disease Alert (RED Alert), a web-based tool designed to help public health officials detect and understand infectious disease re-emergence. Objective: Our objective is to bring together a variety of disease-related data and analytics needed to help public health analysts answer the following 3 primary questions for detecting and understanding disease re-emergence: Is there a potential disease re-emergence at the local (country) level? What are the potential contributing factors for this re-emergence? Is there a potential for global re-emergence? Methods: We collected and cleaned disease-related data (eg, case counts, vaccination rates, and indicators related to disease transmission) from several data sources including the World Health Organization (WHO), Pan American Health Organization (PAHO), World Bank, and Gideon. We combined these data with machine learning and visual analytics into a tool called RED Alert to detect re-emergence for the following 4 diseases: measles, cholera, dengue, and yellow fever. We evaluated the performance of the machine learning models for re-emergence detection and reviewed the output of the tool through a number of case studies. Results: Our supervised learning models were able to identify 82%-90% of the local re-emergence events, although with 18%-31% (except 46% for dengue) false positives. This is consistent with our goal of identifying all possible re-emergences while allowing some false positives. The review of the web-based tool through case studies showed that local re-emergence detection was possible and that the tool provided actionable information about potential factors contributing to the local disease re-emergence and trends in global disease re-emergence. Conclusions: To the best of our knowledge, this is the first tool that focuses specifically on disease re-emergence and addresses the important challenges mentioned above.

60 APPLIED LIFE SCIENCES↗

Nucleic Acid-Based Detection Protease Activity

Proteases include clinically relevant markers for clotting disorders, certain cancers as well as toxins. Assays for protease activity often use designed peptides mimicking natural substrates and detection with colorometric and fluorescence-based detection that is difficult to multiplex without expensive and resource demanding instruments. This work demonstrates detection of proteolytic activity using PCR and sequencing-readable reporter molecules. The assay development focused on binding the constructed peptide-oligonucleotide chimera to immobilized streptavidin. Thrombin, an essential component of the clotting cascade, was used as a model system for testing peptide substrate recognition and release of a designed oligonucleotide for detection. Detection of protease activity was demonstrated in a concentration-dependent manner using MALDI-MS, RT-PCR and DNA sequencing.

Wunschel, David S [Pacific Northwest National Labo↗

Rapid detection of mexX in Pseudomonas aeruginosa based on CRISPR-Cas13a coupled with recombinase polymerase amplification

The principal pathogen responsible for chronic urinary tract infections, immunocompromised hosts, and cystic fibrosis patients is Pseudomonas aeruginosa , which is difficult to eradicate. Due to the extensive use of antibiotics, multidrug-resistant P. aeruginosa has evolved, complicating clinical therapy. Therefore, a rapid and efficient approach for detecting P. aeruginosa strains and their resistance genes is necessary for early clinical diagnosis and appropriate treatment. This study combines recombinase polymerase amplification (RPA) and clustered regularly interspaced short palindromic repeats-association protein 13a (CRISPR-Cas13a) to establish a one-tube and two-step reaction systems for detecting the mexX gene in P. aeruginosa . The test times for one-tube and two-step RPA-Cas13a methods were 5 and 40 min (including a 30 min RPA amplification reaction), respectively. Both methods outperform Quantitative Real-time Polymerase Chain Reactions (qRT-PCR) and traditional PCR. The limit of detection (LoD) of P. aeruginosa genome in one-tube and two-step RPA-Cas13a is 10 aM and 1 aM, respectively. Meanwhile, the designed primers have a high specificity for P. aeruginosa mexX gene. These two methods were also verified with actual samples isolated from industrial settings and demonstrated great accuracy. Furthermore, the results of the two-step RPA-Cas13a assay could also be visualized using a commercial lateral flow dipstick with a LoD of 10 fM, which is a useful adjunt to the gold-standard qRT-PCR assay in field detection. Taken together, the procedure developed in this study using RPA and CRISPR-Cas13a provides a simple and fast way for detecting resistance genes.

Zhu, Xiao-Xuan↗

Diagnostic Evaluation of the IS1081-Targeted Real-Time PCR for Detection of Mycobacterium bovis DNA in Bovine Milk Samples

The ability of Mycobacterium bovis (M. bovis) to survive in bovine milk has emerged as a serious public health concern. The first objective of this study was to evaluate the diagnostic utility of IS1081-targeted real-time PCR for the detection of M. bovis DNA in different fractions of bovine milk. In a model study, bovine milk samples were spiked with serially diluted M. bovis BCG to investigate the detection limit of M. bovis DNA in whole milk and milk fractions (cream, pellet, and pellet + cream combined) using IS1081 real-time PCR. The assay was then used to detect M. bovis DNA in whole milk and milk fractions from naturally infected animals. The results showed that the IS1081 real-time PCR was more sensitive when detecting M. bovis DNA in the cream layer alone and cream + pellet combined compared to whole milk or the pellet alone. While PCR-based diagnostic assays for the detection of M. bovis in milk samples provide a quicker diagnostic tool for bovine tuberculosis, safe processing, and handling of M. bovis-infected milk samples remain a challenge and pose a human health risk. PrimeStore Molecular Transport Medium (MTM) has been shown to rapidly inactivate infected specimens while preserving nucleic acid for subsequent Molecular analysis. Therefore, the secondary objective of this study was to evaluate the ability of MTM to inactivate M. bovis BCG in spiked milk samples as well as its ability to preserve BCG DNA for the PCR assay. The results showed that MTM can successfully inactivate BCG alone or in spiked milk samples while preserving DNA for the PCR assay. The CT values of M. bovis BCG alone and spiked milk samples aliquoted in MTM and without MTM were similar at various dilutions. Taken together, our results indicate that using DNA extracted from the milk cream fraction alone or combined milk cream and pellet improved the recovery rate of M. bovis DNA in bovine milk samples. MTM has the potential to provide a safe and rapid sample processing tool for M. bovis inactivation in milk samples and preserve DNA for molecular diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Summertime Continental Shallow Cumulus Cloud Detection Using GOES-16 Satellite and Ground-Based Stereo Cameras at the DOE ARM Southern Great Plains Site

Summertime continental shallow cumulus clouds (ShCu) are detected using Geostationary Operational Environmental Satellite (GOES)-16 reflectance data, with cross-validation by observations from ground-based stereo cameras at the Department of Energy Atmospheric Radiation Measurement Southern Great Plains site. A ShCu cloudy pixel is identified when the GOES reflectance exceeds the clear-sky surface reflectance by a reflectance detection threshold of ShCu, ΔR. We firstly construct diurnally varying clear-sky surface reflectance maps and then estimate the ΔR. A GOES simulator is designed, projecting the clouds reconstructed by stereo cameras towards the surface along the satellite’s slanted viewing direction. The dynamic ShCu detection threshold ΔR is determined by making the GOES cloud fraction (CF) equal to the CF from the GOES simulator. Although there are temporal variabilities in ΔR, cloud fractions and cloud size distributions can be well reproduced using a constant ΔR value of 0.045. The method presented in this study enables daytime ShCu detection, which is usually falsely reported as clear sky in the GOES-16 cloud mask data product. Using this method, a new ShCu dataset can be generated to bridge the observational gap in detecting ShCu, which may transition into deep precipitating clouds, and to facilitate further studies on ShCu development over heterogenous land surface.

54 ENVIRONMENTAL SCIENCES↗

AEPF: Attention-Enabled Point Fusion for 3D Object Detection

Current state-of-the-art (SOTA) LiDAR-only detectors perform well for 3D object detection tasks, but point cloud data are typically sparse and lacks semantic information. Detailed semantic information obtained from camera images can be added with existing LiDAR-based detectors to create a robust 3D detection pipeline. With two different data types, a major challenge in developing multi-modal sensor fusion networks is to achieve effective data fusion while managing computational resources. With separate 2D and 3D feature extraction backbones, feature fusion can become more challenging as these modes generate different gradients, leading to gradient conflicts and suboptimal convergence during network optimization. To this end, we propose a 3D object detection method, Attention-Enabled Point Fusion (AEPF). AEPF uses images and voxelized point cloud data as inputs and estimates the 3D bounding boxes of object locations as outputs. An attention mechanism is introduced to an existing feature fusion strategy to improve 3D detection accuracy and two variants are proposed. These two variants, AEPF-Small and AEPF-Large, address different needs. AEPF-Small, with a lightweight attention module and fewer parameters, offers fast inference. AEPF-Large, with a more complex attention module and increased parameters, provides higher accuracy than baseline models. Experimental results on the KITTI validation set show that AEPF-Small maintains SOTA 3D detection accuracy while inferencing at higher speeds. AEPF-Large achieves mean average precision scores of 91.13, 79.06, and 76.15 for the car class’s easy, medium, and hard targets, respectively, in the KITTI validation set. Results from ablation experiments are also presented to support the choice of model architecture.

Chemistry↗

Multiple Mutations Associated with Emergent Variants Can Be Detected as Low-Frequency Mutations in Early SARS-CoV-2 Pandemic Clinical Samples

Genetic analysis of intra-host viral populations provides unique insight into pre-emergent mutations that may contribute to the genotype of future variants. Clinical samples positive for SARS-CoV-2 collected in California during the first months of the pandemic were sequenced to define the dynamics of mutation emergence as the virus became established in the state. Deep sequencing of 90 nasopharyngeal samples showed that many mutations associated with the establishment of SARS-CoV-2 globally were present at varying frequencies in a majority of the samples, even those collected as the virus was first detected in the US. A subset of mutations that emerged months later in consensus sequences were detected as subconsensus members of intra-host populations. Spike mutations P681H, H655Y, and V1104L were detected prior to emergence in variant genotypes, mutations were detected at multiple positions within the furin cleavage site, and pre-emergent mutations were identified in the nucleocapsid and the envelope genes. Because many of the samples had a very high depth of coverage, a bioinformatics pipeline, “Mappgene”, was established that uses both iVar and LoFreq variant calling to enable identification of very low-frequency variants. This enabled detection of a spike protein deletion present in many samples at low frequency and associated with a variant of concern.

60 APPLIED LIFE SCIENCES↗

Detection of Cyclopropenylidene on Titan with ALMA

We report the first detection on Titan of the small cyclic molecule cyclopropenylidene (c-C{sub 3}H{sub 2}) from high-sensitivity spectroscopic observations made with the Atacama Large Millimeter/submillimeter Array. Multiple lines of cyclopropenylidene were detected in two separate data sets: ∼251 GHz in 2016 (Band 6) and ∼352 GHz in 2017 (Band 7). Modeling of these emissions indicates abundances of 0.50 ± 0.14 ppb (2016) and 0.28 ± 0.08 (2017) for a 350 km step model, which may either signify a decrease in abundance, or a mean value of 0.33 ± 0.07 ppb. Inferred column abundances are (3–5) × 10{sup 12} cm{sup −2} in 2016 and (1–2) × 10{sup 12} cm{sup −2} in 2017, similar to photochemical model predictions. Previously the C{sub 3}H{sub 3}{sup +} ion has been measured in Titan’s ionosphere by Cassini’s Ion and Neutral Mass Spectrometer (INMS), but the neutral (unprotonated) species has not been detected until now, and aromatic versus aliphatic structure could not be determined by the INMS. Our work therefore represents the first unambiguous detection of cyclopropenylidene, the second known cyclic molecule in Titan’s atmosphere along with benzene (C{sub 6}H{sub 6}) and the first time this molecule has been detected in a planetary atmosphere. We also searched for the N-heterocycle molecules pyridine and pyrimidine finding nondetections in both cases, and determining 2σ upper limits of 1.15 ppb (c-C{sub 5}H{sub 5}N) and 0.85 ppb (c-C{sub 4}H{sub 4}N{sub 2}) for uniform abundances above 300 km. These new results on cyclic molecules provide fresh constraints on photochemical pathways in Titan’s atmosphere, and will require new modeling and experimental work to fully understand the implications for complex molecule formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Mitigating Shear-dependent Object Detection Biases with Metacalibration

M ETACALIBRATION is a new technique for measuring weak gravitational lensing shear that is unbiased for isolated galaxy images. Here we test M ETACALIBRATION with overlapping, or "blended" galaxy images. Using standard M ETACALIBRATION , we find a few percent shear measurement bias for galaxy densities relevant for current surveys, and that this bias increases with increasing galaxy number density. We show that this bias is not due to blending itself, but rather to shear-dependent object detection. If object detection is shear-independent, no deblending of images is needed, in principle. We demonstrate that detection biases are accurately removed when including object detection in the M ETACALIBRATION process, a technique we call M ETADETECTION . This process involves applying an artificial shear to images of small regions of sky and performing detection on the sheared images, as well as measurements that are used to calculate a shear response. We demonstrate that the method can accurately recover weak shear signals even in highly blended scenes. In the M ETACALIBRATION process, the space between objects is sheared coherently, which does not perfectly match the real universe in which some, but not all, galaxy images are sheared coherently. We find that even for the worst case scenario, in which the space between objects is completely unsheared, the resulting shear bias is at most a few tenths of a percent for future surveys. We discuss additional technical challenges that must be met in order to implement M ETADETECTION for real surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

MEGASIM: Distribution and Detection of Earth Trojan Asteroids

Abstract Using N -body simulation results from the MEGASIM data set, we present spatial distributions of Earth Trojan Asteroids and assess the detectability of the population in current and next-generation ground-based astronomical surveys. Our high-fidelity Earth Trojan Asteroid (ETA) distribution maps show never-before-seen high-resolution spatial features that evolve over timescales up to 1 Gyr. The simulation was synchronized to start times and timelines of two observational astronomy surveys: (1) the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) and (2) the Zwicky Transient Facility (ZTF). We calculate upper limits for the number of ETAs potentially observable with both the ZTF and LSST surveys. Due to the Yarkovsky Effect, we find no stable ETAs on billion-year timescales likely to be detected by any ETA survey, as no C-type or S-type ETAs (with H < 22 and H < 24, respectively) are likely to be stable on billion-year timescales, and ETAs large enough to remain stable on billion-year timescales are very rare relative to the rest of the ETA population. We find that a twilight ETA survey will not drastically increase the likelihood of individual ETA detection, but it would provide orders of magnitude more observations of select ETA populations. The null detection to date from ZTF restricts the potential ETA population to hundreds of objects larger than 100 m (at H ≈ 22), while a null detection by LSST will further restrict the ETA population to tens of objects larger than 100 m.

79 ASTRONOMY AND ASTROPHYSICS↗

A Systematic Search for MeV–GeV Pulsar Wind Nebulae without Gamma-Ray Detected Pulsars

An increasing number of pulsar wind nebulae (PWNe) are being identified in the TeV band by ground-based Imaging Air Cherenkov Telescopes such that they constitute the dominant source class of Galactic TeV emitters. However, MeV–GeV PWN counterparts are still largely lacking. To date, only a dozen PWNe are identified by the Fermi–Large Area Telescope (LAT) in the MeV–GeV band. Most PWNe are located along the Galactic plane embedded within the prominent, diffuse Galactic γ-ray emission, which makes these sources difficult to disentangle from the bright diffuse background. We present a systematic search for γ-ray counterparts to known PWNe in the 300 MeV–2 TeV energy band using the Fermi–LAT. We target the locations of previously identified PWNe that lack detected Fermi–LAT pulsars to minimize associated pulsar contamination. The sample includes six previously identified Fermi PWNe and eight Fermi–LAT sources associated with PWNe. We report the analysis of 58 regions of interest and classify Fermi–LAT detected sources as either a likely PWN or a candidate PWN counterpart based on their morphological and spectral characteristics across the broadband spectrum. There are nine unidentified Fermi–LAT sources that we consider as likely PWN counterparts, which, if confirmed to be PWNe, would greatly increase the PWN population detected by the Fermi–LAT from 12 to 21. The remaining Fermi–LAT detected sources are considered weaker PWN candidates. A second approach in the systematic search for γ-ray emitting PWNe will involve studying the off-pulse phases of Fermi–LAT detected pulsars for the presence of an obscured PWN and will be reported in a subsequent paper.

Acharyya, A. [Univ. of Southern Denmark, Odense (D↗

Advanced Intra-Cycle Detection of Pre-Ignition Events through Phase-Space Transforms of Cylinder Pressure Data

The widespread adoption of boosted, downsized SI engines has brought pre-ignition phenomena into greater focus, as the knock events resulting from pre-ignitions can cause significant hardware damage. Much attention has been given to understanding the causes of pre-ignition and identify lubricant or fuel properties and engine design and calibration considerations that impact its frequency. This helps to shift the pre-ignition limit to higher specific loads and allow further downsizing but does not fundamentally eliminate the problem. Real-time detection and mitigation of pre-ignition would thus be desirable to allow safe engine operation in pre-ignition-prone conditions. This study focuses on advancing the time of detection of pre-ignition in an engine cycle where it occurs. Furthermore, phase space transforms through time-delay embedding of cylinder pressure and principal component analysis were applied to same-cycle detection of pre-ignition and shown to enable detection on the order of a crank degree earlier than deviation in cylinder pressure can be identified through direct statistical observation of the pressure data. Additionally, it appears that the deviation of the trajectory in phase space may offer the opportunity to extend this method to further extend the detection window and allow more time for mitigation actions to occur.

42 ENGINEERING↗

Remote-sensing detectability of airborne Arctic dust

Remote-sensing (RS)-based estimates of Arctic dust are oftentimes overestimated due to a failure in separating out the dust contribution from that of spatially homogeneous clouds or low-altitude cloud-like plumes. A variety of illustrations are given with a particular emphasis on questionable claims of using brightness temperature differences (BTDs) as a signature indicator of Arctic dust transported from mid-latitude deserts or generated by local Arctic sources. While there is little dispute about the presence of both Asian and local dust across the Arctic, the direct RS detectability of airborne dust, as ascribed to satellite (MODIS and AVHRR) measurements of significantly negative brightness temperature differences at 11 and 12 µm (BTD 11–12 ), has been misrepresented in certain cases. While it is difficult to account for all examples of strongly negative BTD 11–12 values in the Arctic, it is unlikely that airborne dust plays a significant role. One much more likely contributor would be water clouds in the Arctic inversion layer. The RS detectability of the impact of Arctic dust (notably due to Arctic dust from local sources) can, however, be of significance. Sustained dust deposition can substantially decrease (visible to shortwave IR) snow and ice reflectance albedo (pan-chromatic reflectance) and the signal measured by satellite sensors. Significantly negative BTD 11–12 values would, however, only represent a limited area near the drainage basin sources according to our event-level case studies. The enhanced ice-nucleating particle (INP) role of local Arctic dust can, for example, induce significant changes in the properties of low-level mixed-phase clouds (cloud optical depth changes <~ 1) that can readily be detected by active and passive RS instruments. It is critical that the distinction between the RS detectability of airborne Arctic dust versus the RS detectability of the impacts of that dust be understood if we are to appropriately parameterize, for example, the radiative forcing influence of dust in this climate-sensitive region.

54 ENVIRONMENTAL SCIENCES↗

Detection of small drizzle droplets in a large cloud chamber using ultrahigh-resolution radar

Abstract. A large convection–cloud chamber has the potential to produce drizzle-sized droplets, thus offering a new opportunity to investigate aerosol–cloud–drizzle interactions at a fundamental level under controlled environmental conditions. One key measurement requirement is the development of methods to detect the low-concentration drizzle drops in such a large cloud chamber. In particular, remote sensing methods may overcome some limitations of in situ methods. Here, the potential of an ultrahigh-resolution radar to detect the radar return signal of a small drizzle droplet against the cloud droplet background signal is investigated. It is found that using a small sampling volume is critical to drizzle detection in a cloud chamber to allow a drizzle drop in the radar sampling volume to dominate over the background cloud droplet signal. For instance, a radar volume of 1 cubic centimeter (cm3) would enable the detection of drizzle embryos with diameter larger than 40 µm. However, the probability of drizzle sampling also decreases as the sample volume reduces, leading to a longer observation time. Thus, the selection of radar volume should consider both the signal power and the drizzle occurrence probability. Finally, observations from the Pi Convection–Cloud Chamber are used to demonstrate the single-drizzle-particle detection concept using small radar volume. The results presented in this study also suggest new applications of ultrahigh-resolution cloud radar for atmospheric sensing.

54 ENVIRONMENTAL SCIENCES↗

Investigating lab-scaled offshore wind aerodynamic testing failure and developing solutions for early anomaly detections

As offshore wind systems become more complex, the risk of human error or equipment malfunction increases during experimental testing. This study investigates a lab-scale incident involving a 1 : 50 scale 5 MW wind turbine, where a generator failure led to rotor overspeed and a blade–tower strike. To improve early fault detection, we propose a data-driven method based on multivariate long short-term memory (LSTM) models. High-frequency measurements are projected onto principal components, and anomalies are identified using reconstruction error and its time derivative. Two models are trained on different healthy datasets and tested using single- and multi-principal component (1PC and MPC) variations. Results show that combining both error and error derivative improves detection accuracy. The 1PC model detects faults faster, has a higher recall rate, and achieves a 43 % improvement in anomaly detection accuracy, while the MPC model yields higher precision. This approach provides a simple and effective tool for early anomaly detection in lab-scale experiments, helping to reduce the risk of future failures during the testing of new technologies.

17 WIND ENERGY↗

Accurate in vivo tumor detection using plasmonic-enhanced shifted-excitation Raman difference spectroscopy (SERDS)

For the majority of cancer patients, surgery is the primary method of treatment. In these cases, accurately removing the entire tumor without harming surrounding tissue is critical; however, due to the lack of intraoperative imaging techniques, surgeons rely on visual and physical inspection to identify tumors. Surface-enhanced Raman scattering (SERS) is emerging as a non-invasive optical alternative for intraoperative tumor identification, with high accuracy and stability. However, Raman detection requires dark rooms to work, which is not consistent with surgical settings. Methods: Herein, we used SERS nanoprobes combined with shifted-excitation Raman difference spectroscopy (SERDS) detection, to accurately detect tumors in xenograft murine model. Results: We demonstrate for the first time the use of SERDS for in vivo tumor detection in a murine model under ambient light conditions. We compare traditional Raman detection with SERDS, showing that our method can improve sensitivity and accuracy for this task. Conclusion: Our results show that this method can be used to improve the accuracy and robustness of in vivo Raman/SERS biomedical application, aiding the process of clinical translation of these technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Artificial neural network based isotopic analysis of airborne radioactivity measurement for radiological incident detection

Responders need tools to rapidly detect and identify airborne alpha radioactivity during consequence management scenarios. Traditional continuous air monitor systems used for this purpose compute the net counts in various energy windows to determine the presence of specified isotopes, such as 235U, 239Pu, and 241Am. These calculations rely on having a well-calibrated detector, which is challenging in low-background environments. Here an alternative approach of using artificial neural networks to classify alpha spectra is presented. Two network architectures, fully connected and convolutional networks, were trained to classify alpha spectra into four categories: background and background plus the three isotopes above. Sources were injected into measured background at various fractions of the derived response level (DRL) corresponding to early-phase Protective Action Guides. The convolutional network identifies all sources at 1% of the DRL with average probability of detection of 95% and false alarm probability of 1%. Further, the network identifies sources ranging between 0.25% and 1% of the DRL with higher than 80% probability of detection and lower than 7% false alarm probability. Most significantly, the network performance improves in low-count background conditions, increasing its minimum probability of detection to 93% and reducing the false alarm probabilities to lower than 0.25%. These results show that, once trained on datasets representing a range of detection scenarios, artificial neural networks can accurately identify alpha isotopes of interest without the need for detector calibration.

Woldegiorgis, Surafel F.↗