Power Distribution System Characterization With Active Probing: Real-World Testing and Analysis
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This paper proposes an online data-driven distributed energy resource management system (DERMS) for distribution system optimal DER dispatch as well as voltage regulation. Here, the key innovation is to leverage the Local Sensitivity Factor (LSF) for transforming the DER control into a computationally efficient linear programming (LP) problem. By taking real-time measurements, the estimation of LSF eliminates the need for an accurate distribution system model as well as full nodal load information, which is difficult to achieve in practice. A robust recursive least squares method is also developed to ensure the robust estimation of LSF, which is initialized using reasonable values from model-derived LSFs. This allows the system to adapt to changing operational conditions effectively. A scenario-based, chance-constrained framework is further employed to ensure voltage remains within acceptable limits in the presence of measurement and estimation uncertainties. Test results on a real-world, 759-node distribution network located in western Colorado, U.S., validate the effectiveness and robustness of the proposed control approach and demonstrate its superior performance as compared to alternative methods.
Federated finetuning is crucial for unlocking the knowledge embedded in pretrained Large Language Models (LLMs) when data are geographically distributed across clients. Unlike finetuning with data from a single institution, federated finetuning allows collaboration across multiple institutions, enabling the utilization of diverse and decentralized datasets while preserving data privacy. Given the high computing costs of LLM training and the emphasis on energy efficiency in Federated Learning (FL), Low-Rank Adaptation (LoRA) has emerged as a widely adopted algorithm due to its significantly reduced number of trainable parameters. However, this assumes that all data silos have the necessary computing resources to compute local updates of LLMs. Nevertheless, in practice, the computing resources across clients are highly heterogeneous: while some may have access to hundreds of GPUs, others might have limited or no GPU access. Recently, federated finetuning using synthetic data has been proposed, allowing clients to participate in a collaborative training run without training LLMs locally. However, our experimental results reveal a performance gap between models trained using synthetic data and those trained using local updates. Motivated by the observed heterogeneity in computing resources and the performance gap, we propose a novel two-stage algorithm that leverages the storage and computing capabilities of a strong server. In the first stage, under the coordination of the strong server, clients with limited computing resources collaborate to generate synthetic data, which is transferred to and stored on the strong server. In the second stage, the strong server uses this synthetic data on behalf of the resource-constrained clients to perform federated LoRA finetuning alongside clients with sufficient computing resources. This approach ensures that all clients can participate in the finetuning process. Experimental results demonstrate that incorporating local updates from even a small fraction of clients improves performance compared to using synthetic data for all clients. Furthermore, we incorporate the Gaussian mechanism in both stages to guarantee client-level differential privacy.
This dataset comprises temporal dynamic graph sequences generated from power grid simulations focused on grid reconfiguration to enhance resilience. The simulations model failure propagation under varying conditions, with nodes assigned distinct failure probabilities. For each time step, the dataset captures the evolution of node states (functional or failed) and features critical to grid operations, such as pv_output, load_profile, load_dispatch, dg_output, loss, and voltage. Node types include sources, normal loads, and nodes with specific equipment like PVs, micro turbines, or shunt capacitors. The dataset is structured to support the training of dynamic graph neural networks, facilitating research on node feature prediction and edge dynamics under failure scenarios. Three distinct configurations are included, providing a robust foundation for modeling power grid resilience.
Vanadium dioxide (VO 2 ) has been widely studied due to its metal-insulator phase transition at 68°C, below which it is a semiconducting monoclinic phase, P2 1 /c, and above it is a metallic tetragonal phase, P4 2 /mnm. Substituting vanadium with transition metals allows transition temperature tunability. An accelerated microwave-assisted synthesis for VO 2 and 5d tungsten substituted VO 2 presented herein decreased synthesis time by three orders of magnitude while maintaining phase purity, particle size, and transition character. Tungsten substitution amount was determined using inductively coupled plasma-optical emission spectroscopy. Differential scanning calorimetry, superconducting quantum interference device measurements, and in-situ heating and cooling experiments monitored through synchrotron x-ray diffraction (XRD) confirmed the transition temperature decreased with increased tungsten substitution. Scanning electron microscopy analyzed through the line-intercept method produced an average particle size of 3 – 5 μm. Average structure and local structure phase purity was determined through Rietveld analysis of synchrotron XRD and least-squares refinement of pair-distribution function data.
In this analysis, we report on 250 PV systems throughout the US, comprising 157 MWdc of system capacity and over 10,000 monthly PI values based on high-frequency (subhourly) energy data and satellite-based resource data. The distribution of PI values is analyzed, and multiple causes of underperformance are assessed, including first-year startup issues, snowfall and inverter downtime. An initial distribution of raw monthly PI values was collected with mean measured / modeled performance of PI = 0.935. After correcting for the three identifiable loss factors mentioned above, an average monthly performance of PI = 0.994 was obtained, with a distribution closely following a Gumbel Extreme Value distribution. In particular, inverter availability was found to contribute a system energy loss of 2.3% on average, except in the first six months of operation when availability losses are closer to 8%. Other startup issues beyond inverter downtime such as partial string outage contributed an additional 5% underperformance in the first year of operation across the fleet. Winter performance was also found to be 5%-10% below summer performance on average, likely due to snowfall. A simple linear relationship was found between snow loss and monthly snowfall accumulation in cm, indicating between 6% - 40% loss in months with nonzero snowfall, depending on climate.
This report details the accomplishments from the ASCR funded project “Integrated End-to-end Performance Prediction and Diagnosis for Extreme Scientific Workflows” under the award numbers FWP-66406 and DE-SC0012630, with a focus on the UC San Diego (Award No. DE-SC0012630) part of the accomplishments. We refer to the project as IPPD. The main activities of IPPD were centered on the development and integration of provenance information to capture empirically workflow information and identify the sources of bottlenecks as well as variability, and modeling and simulation to provide insights and predictively explore multiple scenarios for development of advanced techniques for optimization of resources and workflow execution. After a Phase I of the project, a Phase II effort focused on three major aspects: a) observe how data is generated, distributed, and used; b) analyze how data is (repeatedly) consumed with a focus both on repeated patterns and anomalies; and c) explore how to optimize data motion. The project leveraged and extended our existing tools with new research and demonstrated our work on the Belle II workflow suite as well as on workflows from NSLS-II.
Explore the source record for details and available documents.
The Flow Sensor Test Article (F-STAr) is a new test article under development for the Mechanisms Engineering Test Loop (METL) facility at Argonne National Laboratory. F-STAr’s purpose is to provide sodium submersible, high flowrate testing capabilities for the development of sensors, components, fluid studies and more. This report will provide a status update on the assembly and initial qualification testing of F-STAr. All components have been manufactured and received. Some modifications to these components were made to support minor changes in the test article design. Additionally, the power distribution, and data acquisition and control enclosures were designed, completed, and tested along with the control system software. Furthermore, initial qualification testing was completed in water. Finally, the F-STAr submersible Electromagnetic Flowmeter (EMFM) was completed and calibrated in flowing sodium.
Dataset contamination is a problem where benchmarks and tasks used to evaluate the capabilities of Large Language Models (LLMs) have been incorporated into the training dataset of the models. This gives a false sense of performance that can overestimate how these models will function on truly unseen data. This problem becomes worse with commercial LLMs with larger and non-accessible training data, so techniques have been developed to try to measure the degree to which a model is contaminated with a benchmark’s data. To understand the effectiveness of these techniques, particularly when evaluating contamination on coding tasks, we review trends and categorize techniques by the degree of access to the model that is required. The research literature on this topic has reported mixed effectiveness of these techniques, so we select a set of black box (text access only) and grey box (access to model loss/probabilities required) techniques and apply them to both commercial and non-commercial models. We implement these metrics as part of a framework to test the contamination of Python code in LLMs to see to what extent we can replicate the effectiveness (or ineffectiveness) of these contamination detection techniques. Though we find mixed results in the capabilities of these metrics to identify contamination, we do observe evidence that they can identify contamination (broadly) in fine-tuned models when both a baseline and fine-tuned model is present. Additionally, similarity metrics were able to identify between contaminated and uncontaminated data even in situations where the data is distributionally similar (e.g., drawn from the same set of code projects).
Developed for atmospheric science: specifically, a tool for processing sparse photon propagation data
This presentation will cover these topics, followed by a discussion and Q&A: Grid impacts of load growth of the current bulk power system, a review of recent trends and events related to large load integration, what might these new large loads look like, what are options for reducing costs and timelines of integration, and working toward a framework for identifying hot spots for efficiently interconnecting large loads.
We report the results of a search for long-period (100 < P < 600 days) periodic variability in the SDSS Stripe 82 standards catalog. The SDSS coverage of Stripe 82 enables such a search because there are on average 20 observations per band in ugriz bands for about one million sources, collected over about 6 yr, with a faint limit of r ~ 22 mag and precisely calibrated 1%–2% photometry. We calculated the periods of variable source candidates in this sample using the Lomb–Scargle periodogram and considered the three highest periodogram peaks in each of the gri filters as relevant. Only those sources with gri periods consistent within 0.1% were later studied. We use the Kuiper statistic to ensure uniform distribution of data points in phased light curves. We present five sources with the spectra consistent with quasar spectra and plausible periodic variability. This SDSS-based search bodes well for future sensitive large-area surveys, such as the Rubin Observatory Legacy Survey of Space and Time, which, due to its larger sky coverage (about a factor of 60) and improved sensitivity (~2 mag), will be more powerful for finding such sources.
The Department of Energy's (DOE) Geothermal Data Repository (GDR) is celebrating its tenth anniversary! Over the last decade it has grown from the simple idea of storing public data in a centralized location to a valuable tool at the center of the US geothermal scientific community and an integral part of the DOE Geothermal Technologies Office (DOE GTO) project management strategy. Researchers funded by the DOE GTO have contributed over 1,300 data submissions to the GDR. These data have been used to further advancements in geothermal science, economic analysis, exploration, research, development, and operational efficiency. The adoption of open data methodologies and a data management strategy that prioritizes universal open access and standardized, interoperable data have further increased the value of GDR data, making them available across a distributed network of data sharing partners and improving their utility to other industries and related fields, including material science and space exploration. Incorporating feedback from users has been critical to the GDRs success, allowing it to grow over the years to meet the evolving needs of the geothermal community. This paper will explore some of many changes that occurred throughout the GDRs tenure and the lessons learned along the way, as well as highlight some of the new features and recent improvements that been implemented to support innovation, reduce duplication of effort, and advance the geothermal industry as a whole.
The Department of Energy's (DOE) Geothermal Data Repository (GDR) is celebrating its tenth anniversary! Over the last decade it has grown from the simple idea of storing public data in a centralized location to a valuable tool at the center of the US geothermal scientific community and an integral part of the DOE Geothermal Technologies Office (DOE GTO) project management strategy. Researchers funded by the DOE GTO have contributed over 1,300 data submissions to the GDR. These data have been used to further advancements in geothermal science, economic analysis, exploration, research, development, and operational efficiency. The adoption of open data methodologies and a data management strategy that prioritizes universal open access and standardized, interoperable data have further increased the value of GDR data, making them available across a distributed network of data sharing partners and improving their utility to other industries and related fields, including material science and space exploration. Incorporating feedback from users has been critical to the GDR's success, allowing it to grow over the years to meet the evolving needs of the geothermal community. This paper will explore some of many changes that occurred throughout the GDRs tenure and the lessons learned along the way, as well as highlight some of the new features and recent improvements that been implemented to support innovation, reduce duplication of effort, and advance the geothermal industry as a whole.
The objective of this project is to develop modular data repository and computing architecture with open-source datasets and baseline DER management algorithms.
This dataset comprises Distributed Acoustic Sensing (DAS) data collected from the Utah FORGE monitoring well 16B(78)-32 (the producer well) during hydraulic fracture stimulation operations conducted in April 2024. The data were acquired continuously over the stimulation period at a temporal sampling rate of 10,000 Hz (10 kS/s) and a spatial resolution of approximately 3.35 feet (1.02109 meters). The measurements were captured using a Neubrex NBX-S4100 Time Gated Digital DAS interrogator unit connected to a single-mode fiber optic cable, which was permanently installed within the casing string. All recorded channels correspond to downhole segments of the fiber optic cable, from a measured depth (MD) of 5,369.35 feet to 10,352.11 feet. The DAS data reflect raw acoustic energy generated by physical processes within and surrounding the well during stimulation activities at wells 16A(78)-32 and 16B(78)-32. These data have potential applications in analyzing cross-well strain, far-field strain rates (including microseismic activity), induced seismicity, and seismic imaging. Metadata embedded in the attributes of the HDF5 files include detailed information on the measured depths of the channels, interrogation parameters, and other acquisition details. The dataset also includes a recording of a seminar held on September 19, 2024, where Neubrex's Chief Operating Officer presented insights into the data collection, analysis, and preliminary findings. The raw data files, stored in HDF5 format, are organized chronologically according to the recording intervals from April 9 to April 24, 2024, with each file corresponding to a 12-second recording interval.
Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.