Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Critical infrastructure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Autonomous Tools for Attack Surface Reduction (Final Report)

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic wellbeing. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyberattacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever-growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal was to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The following are the specific tasks that have been successfully completed two phases (2016-2020). Phase I: Task 1: Developed and implemented a robust Project Management and Data Management Plan, coupled with a well thought out Risk Mitigation Plan. Task 2.1: Developed a comprehensive framework that continually assesses and autonomously reduces the attack surface for the power grid control environment spanning across substations, control center and the SCADA network to significantly reduce the risks of cyber attacks. Task 2.2: Developed attack surface analysis techniques, metrics, and tools that assess the attack surface at multiple levels including the control center, substations, and the SCADA network. Task 2.3: Developed attack surface reduction techniques and tools that dynamically reduce attack surface and hence increase attacker’s cost without interfering in the critical functions of the system. Task 2.4: Prototyped, implemented, and quantitatively evaluated/validated the techniques and tools on a realistic industrial CPS security testbed environment by leveraging the unique resources of the team. Task 3: Developed Commercialization plan to transition the developed tools into power system industry stakeholders for a broader adoption by leveraging the expertise of our industrial members. Phase II: Task 4: Successfully completed field demonstration, verification, and evaluation of the effectiveness of the attack surface analysis and reduction techniques on a realistic utility testbed environment. This also involved the development of realistic scenarios, sound metrics, data sets, evaluation criteria, and documentation. Technology integration & Field demonstration: The project had significantly advanced the state-of-the-art research and practice in improving the cybersecurity of our nation’s power grid infrastructure against cyber threats. In particular, the proposed, designed, and deployed attack surface analysis and reduction algorithms and tools have contributed to significantly reducing the exposure and risk of the devices, substations, and the integrated SCADA/EMS/ DMS grid environment to cyber threat. Strong demonstration and evaluation techniques have verified the feasibility of the developed techniques on realistic cyber-physical testbeds and utility partner's real grid environment, and collaborative research and evaluation of attack surface reduction techniques (for wide-are monitoring and control) within a vendor (GE) EMS platform. The Attack Host Analyzer (AHA) tool that was developed through this project was made available through GitHub.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TASTI-GRID: a holistic view of Florida's grid resilience opportunities

In December of 2025, the American Society of Civil Engineers updated Florida’s infrastructure grade to a ”C+” – reflecting overall investments in recent years. With the recommendation to further strengthen the electric grid and establish consistent building standards, extreme weather, aging infrastructure, and population in-migration are still compounding Florida’s grid vulnerabilities. Key challenges related to hurricane and other tropical & marine weather events are not unique to Florida. However, the state’s topography, location, demographics, and variation among rural and urban centers for tourism and industry, demonstrate the need for unique approaches to advancing critical infrastructure resilience, particularly for large concentrations of elderly residents or in areas of historic underinvestment. Florida’s grid asset advancements are credited with a reduction in average power outage durations. Yet, improvements since 2021 have set the stage for future resilience activities – as modernization efforts have greatly improved data collection – enabling better understanding of vulnerabilities and trends across counties and localities (particularly in Central Florida).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Domestic Extremism: Countering the Threat Posed to Critical Assets

Domestic extremism has been a growing concern in the United States in recent months, as illustrated in multiple bulletins from the Department of Homeland Security (DHS) warning law enforcement partners of the heightened threat. As concerns about these actors grows, it is important that facilities in the U.S. and internationally that protect critical assets, such as sensitive information, hazardous materials, or critical infrastructure, have effective methods in place to secure those assets. DE has challenged security systems through the threat of insider attack and violence, creating a new threat to be countered in the Office of Radiological Security’s radiological source security mission. In this effort, we used a literature review and focus group discussions with experts in critical asset security and extremism to understand the nature of the domestic extremist threat, to identify best practices in securing assets, recognize potential gaps in security measures to be corrected, and recommend actions and next steps. Twenty-two subject matter experts participated in a series of five focus group sessions. Questions focused on definitions of domestic extremism, potential changes in the threat, best practices in securing facilities, assets, and personnel, and any perceived gaps. Upon completion of the focus groups, notes were analyzed thematically to identify any recurring patterns in the results. In addition, a review of academic, industry, and government literature was conducted to understand the threat, describe the process of radicalization to extremism, and to identify empirically informed practices in prevention and response. Results of this project demonstrated that further work is needed to define domestic extremism in law, regulation, and policy, to help the U.S. develop a consistent response to the threat within organizations. This is especially important, as SMEs emphasized the need for early intervention in prevention efforts, noting that organizations need clear guidance on when and how to intervene. In addition, the need for social media monitoring was discussed, although challenges remain to do so with appropriate respect for privacy and civil liberties concerns.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Transductive Graph Neural Network learning for Grid Resilience Analysis

Power grids are critical infrastructures that require robust resilience analysis to ensure reliable and uninterrupted electricity supply. Traditional simulation-based methods for grid resilience analysis suffer from computational complexity and limited ability to capture the full spectrum of potential disruptions. This paper presents a novel approach to enhance grid resilience by leveraging transductive graph neural network (GNN) learning to identify critical nodes and links. By leveraging the graph structure and system features, GNNs effectively learn resilience metrics and accurately identify critical nodes based on actual grid operational behavior. The efficacy of the proposed approach is demonstrated through case studies on node criticality scoring and critical node/line identification in cascading outage scenarios. The results highlight the advantages of learning-based methods over traditional simulation-based approaches and their potential to revolutionize grid resilience analysis. The contributions of this paper include a graph-based scalable approach for fast cascading analysis, an inductive formulation for training GNN models, and a transfer learning-based approach to scale the model to largescale power systems.

grid resilience, graph neural networks, transducti↗

Autonomous Tools for Attack Surface Reduction

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic well being. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyber attacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal is to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The team consisted of leading experts from two major universities – Iowa State University, Washington State University – complemented by reputed researchers from two DOE national laboratories – Pacific Northwest National Lab, and Argonne National Lab, one major utility vendor GE Global Research, and one utility partner – Cedar Falls Utilities (CFU). The team members have proven track record of successful academic-industry collaboration in interdisciplinary R&D projects, and bring onboard some of the best state-of-the-art testbed resources, industry-grade SCADA/EMS/DMS environment for experimentation and field demonstration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Resilience and Social Equity: Twin Pillars of a Sustainable Energy Future

This paper examines the intersection of security and accessibility within energy systems amidst the rise of grid modernization and digitization, especially considering the regulatory changes and the imperatives of inclusive energy strategies. It addresses the dual need for secure, resilient infrastructure and a commitment to mitigate energy poverty while maintaining equitable access to energy. Amid escalating cybersecurity and physical threats, the paper advocates for sustainable energy delivery systems that ensure robust defenses without compromising the goals of reducing energy poverty and ensuring energy security. This paper identifies the pressing need for Cyber-Informed Engineering (CIE) and Secure-by-Design (SbD) principles, highlighting how these strategies can protect critical infrastructure and democratize access to secure energy, particularly for disadvantaged communities. The analysis underscores the challenges presented by the expansion of attack surfaces, interoperability requirements, and grid-edge analytics, offering innovative solutions that leverage advanced technologies and data-driven insights. Furthermore, this paper addresses the workforce development gap, emphasizing the necessity for public-private partnerships and vendor engagement in creating a skilled cybersecurity workforce. This paper has a dual focus on both the technological aspect of cybersecurity and the social dimension of equity within the context of sustainable energy development. It suggests a comprehensive examination of how these two critical elements interact and support the overarching goal of a sustainable energy future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application of Mobile Energy Storage for Enhancing Power Grid Resilience: A Review

Natural disasters can lead to large-scale power outages, affecting critical infrastructure and causing social and economic damages. These events are exacerbated by climate change, which increases their frequency and magnitude. Improving power grid resilience can help mitigate the damages caused by these events. Mobile energy storage systems, classified as truck-mounted or towable battery storage systems, have recently been considered to enhance distribution grid resilience by providing localized support to critical loads during an outage. Compared to stationary batteries and other energy storage systems, their mobility provides operational flexibility to support geographically dispersed loads across an outage area. This paper provides a comprehensive and critical review of academic literature on mobile energy storage for power system resilience enhancement. As mobile energy storage is often coupled with mobile emergency generators or electric buses, those technologies are also considered in the review. Allocation of these resources for power grid resilience enhancement requires modeling of both the transportation system constraints and the power grid operational constraints. These aspects are discussed, along with a discussion on the cost–benefit analysis of mobile energy resources. The paper concludes by presenting research gaps, associated challenges, and potential future directions to address these challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Hydropower Plants for Wildfire Resilient Microgrids

The increasing occurrence and severity of wildfires in recent years is severely impacting critical infrastructures, including the power grid, compromising the quality of life and provision of essential services, including electricity. The western parts of the United States, more specifically Washington, Oregon, and California, which are prone to large wildfires, are also rich in hydropower resources. Hydropower resources located close to communities vulnerable to wildfire can be utilized to develop wildfire-resilient microgrids to support critical needs of those communities. Therefore, this paper develops a framework to characterize hydropower plants and evaluate their feasibility to operate in microgrids during wildfire-related outages. In the proposed framework, hydropower plants are characterized using various plant and site attributes and evaluated in terms of capability and performance indicative metrics. A case study is carried out evaluating the Hills Creek hydropower plant located in a wildfire-prone region of Oregon for wildfire-resilient microgrid. The results of steady-state and dynamic simulations show that the hydropower plant is capable of providing the essential microgrid services and powering nearby communities during extended wildfire-related outages.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

NASA’s Mid-Atlantic Communities and Areas at Intensive Risk Demonstration: Translating Compounding Hazards to Societal Risk

Remote sensing provides a unique perspective on our dynamic planet, tracking changes and revealing the course of complex interactions. Long term monitoring and targeted observation combine with modeling and mapping to provide increased awareness of hydro-meteorological and geological hazards. Disasters often follow hazards and the goal of NASA’s Disasters Program is to look at the earth as a highly coupled system to reduce risk and enable resilience. Remote sensing and geospatial science are used as tools to help answer critical questions that inform decisions. Data is not the same as information, nor does understanding of processes necessarily translate into decision support for disaster preparedness, response and recovery. Accordingly, NASA is engaging the scientific and decision-support communities to apply remote sensing, modeling, and related applications in Communities and Areas at Intensive Risk (CAIR). In 2017, NASA’s Applied Sciences Disasters Program hosted a regional workshop to explore these issues with particular focus on coastal Virginia and North Carolina. The workshop brought together partners in academia, emergency management, and scientists from NASA and partnering federal agencies to explore capabilities among the team that could improve understanding of the physical processes related to these hazards, their potential impact to changing communities, and to identify methodologies for supporting emergency response and risk mitigation. The resulting initiative, the mid-Atlantic CAIR project, demonstrates the ability to integrate satellite derived earth observations and physical models into actionable, trusted knowledge. Severe storms and associated storm surge, sea level rise, and land subsidence coupled with increasing populations and densely populated, aging critical infrastructure often leave coastal regions and their communities extremely vulnerable. The integration of observations and models allow for a comprehensive understanding of the compounding risk experienced in coastal regions and enables individuals in all positions make risk-informed decisions. This initiative uses a representative storm surge case as a baseline to produce flood inundation maps. These maps predict building level impacts at current day and for sea level rise (SLR) and subsidence scenarios of the future in order to inform critical decisions at both the tactical and strategic levels. To accomplish this analysis, the mid-Atlantic CAIR project brings together Federal research activities with academia to examine coastal hazards in multiple ways: 1) reanalysis of impacts from 2011 Hurricane Irene, using numerical weather modeling in combination with coastal surge and hydrodynamic, urban inundation modeling to evaluate combined impact scenarios considering SLR and subsidence, 2) remote sensing of flood extent from available optical imagery, 3) adding value to remotely sensed flood maps through depth predictions, and 4) examining coastal subsidence as measured through time-series analysis of synthetic aperture radar observations. Efforts and results are published via ArcGIS story maps to communicate neighborhoods and infrastructure most vulnerable to changing conditions. Story map features enable time-aware flood mapping using hydrodynamic models, photographic comparison of flooding following Hurricane Irene, as well as visualization of heightened risk in the future due to SLR and land subsidence.

Rogers, Laura↗

Cyber Threats to Nuclear Infrastructures

Nuclear facility personnel expend considerable efforts to ensure that their facilities can maintain continuity of operations against both natural and man-made threats. Historically, most attention has been placed on physical security. Recently however, the threat of cyber-related attacks has become a recognized and growing world-wide concern. Much attention has focused on the vulnerability of the electric grid and chemical industries to cyber attacks, in part, because of their use of Supervisory Control and Data Acquisition (SCADA) systems. Lessons learned from work in these sectors indicate that the cyber threat may extend to other critical infrastructures including sites where nuclear and radiological materials are now stored. In this context, this white paper presents a hypothetical scenario by which a determined adversary launches a cyber attack that compromises the physical protection system and results in a reduced security posture at such a site. The compromised security posture might then be malevolently exploited in a variety of ways. The authors conclude that the cyber threat should be carefully considered for all nuclear infrastructures.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Multi-Scenario Use Case based Demonstration of Buildings Cybersecurity Framework Webtool

The purpose of this paper is to demonstrate the cybersecurity and software capabilities of Buildings Cybersecurity Framework (BCF) webtool. The webtool is designed based on BCF document and existing NIST standards. It’s capabilities and features are depicted through a building usecase with four different investment scenarios geared towards improving the cybersecurity posture of the building. BCF webtool also facilitates implementation of the goals outlined in Presidential Executive Order (EO) on Strengthening the Cybersecurity of Federal Networks and Critical Infrastructure (May 2017. In realization of the EO goals, BCF includes five core elements: Identify, Protect, Detect, Respond, and Recover, to help determine various policy and process level vulnerabilities and provide mitigation strategies. With the BCF webtool, an organization can perform a cybersecurity self-assessment; determine the current cybersecurity posture; define investment based goals to achieve a target state; connect the cybersecurity posture with business processes, functions, and continuity; and finally, develop plans to answer critical organizational cybersecurity questions. In this paper, the webtool and its core capabilities are depicted by performing an extensive comparative assessment over four different scenarios.

Gourisetti, Sri Nikhil G.↗

Developing Coastal Adaptation to Climate Change in the New York City Infrastructure-Shed: Process, Approach, Tools, and Strategies

While current rates of sea level rise and associated coastal flooding in the New York City region appear to be manageable by stakeholders responsible for communications, energy, transportation, and water infrastructure, projections for sea level rise and associated flooding in the future, especially those associated with rapid icemelt of the Greenland and West Antarctic Icesheets, may be beyond the range of current capacity because an extreme event might cause flooding and inundation beyond the planning and preparedness regimes. This paper describes the comprehensive process, approach, and tools developed by the New York City Panel on Climate Change (NPCC) in conjunction with the region s stakeholders who manage its critical infrastructure, much of which lies near the coast. It presents the adaptation approach and the sea-level rise and storm projections related to coastal risks developed through the stakeholder process. Climate change adaptation planning in New York City is characterized by a multi-jurisdictional stakeholder-scientist process, state-of-the-art scientific projections and mapping, and development of adaptation strategies based on a risk-management approach.

Rosenzweig, Cynthia↗

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

Underground Infrastructure Impacts Due to a Surface Burst Nuclear Device in an Urban Canyon Environment

Investigation of the effects of a nuclear device exploded in an urban environment such as the Chicago studied for this particular report have shown the importance on the effects from the urban canyons so typical of today's urban environment as compared to nuclear test event effects observed at the Nevada Test Site (NTS) and the Pacific Testing Area on which many of the typical legacy empirical codes are based on. This report first looks at the some of the data from nuclear testing that can give an indication of the damage levels that might be experienced due to a nuclear event. While it is well known that an above ground blast, even a ground burst, very poorly transmits energy into the ground (< 1%) and the experimental results discussed here are for fully coupled detonations, these results do indicate a useful measure of the damage that might be expected. The second part of the report looks at effects of layering of different materials that typically would make up the near ground below surface environment that a shock would propagate through. As these simulations support and is widely known in the community, the effects of different material compositions in these layers modify the shock behavior and especially modify the energy dispersal and coupling into the basement structures. The third part of the report looks at the modification of the underground shock effects from a surface burst 1 KT device due to the presence of basements under the Chicago buildings. Without direct knowledge of the basement structure, a simulated footprint of a uniform 20m depth was assumed underneath each of the NGI defined buildings in the above ground environment. In the above ground case, the underground basement structures channel the energy along the line of site streets keeping the shock levels from falling off as rapidly as has been observed in unobstructed detonations. These simulations indicate a falloff of factors of 2 per scaled length as compared to 10 for the unobstructed case. Again, as in the above ground case, the basements create significant shielding causing the shock profile to become more square and reducing the potential for damage diagonal to the line of sight streets. The results for a 1KT device is that the heavily damaged zone (complete destruction) will extend out to 50m from the detonation (≈100m for 10KT). The heavily to moderately damaged zone will extend out to 100m (≈200m for 10KT). Since the destruction will depend on geometric angle from the detonation and also the variability of response for various critical infrastructure, for planning purposes the area out to 100m from the detonation should be assumed to be non-operational. Specifically for subway tunnels, while not operational, they could be human passable for human egress in the moderately damaged area. The results of the simulations presented in this report indicate only the general underground infrastructure impact. Simulations done with the actual basement geometry would be an important improvement. Equally as important or even more so, knowing the actual underground material configurations and material composition would be critical information to refine the calculations. Coupling of the shock data into structural codes would help inform the emergency planning and first response communities on the impact to underground structures and the state of buildings after the detonation.

99 GENERAL AND MISCELLANEOUS↗

DER Digital Supply Chain Gap Analysis

Solar photovoltaic (PV) cybersecurity is a growing field of research. As deployments of solar PV have increased, cyber risk has also increased. Utility solar PV installations, however, are not required to comply with the North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (CIP) plan unless they meet a minimum generation threshold of 75 MW. Individual residential-scale solar PV deployments will not meet that generation threshold and are therefore excluded from the NERC CIP requirements. With most solar installations less than 75 MW, solar PV has been deployed with minimal oversight and highly variable cybersecurity maturity. The resources that comprise the digital supply chain can include software, code, data, and other digital components. But as clean energy technologies advance, cybersecurity threats and vulnerabilities continue to evolve and grow in sophistication. Supply chain cybersecurity represents a critical area for ensuring safe operations as the U.S. moves toward a clean energy future.

cybersecurity↗

Towards generic memory forensic framework for programmable logic controllers

A Programmable Logic Controller (PLC) is a microprocessor-based controller that is used to automate physical processes in critical infrastructure and various other industries and manufacturing sectors. Initially, PLCs were completely isolated from the Internet, and cyber security was not incorporated at the time of development. The introduction of industry 4.0 and the evolution of ICS systems to communicate over public IP addresses from the Internet enhanced productivity and efficiency, but Internet connectivity exposed the systems and their vulnerabilities, which led to an increase in cyber attacks. When a system is sabotaged/compromised, security analysts need to get to the root cause of the attack as quickly as possible to recover the system. To do so, memory forensic analysis is critical to provide a unique insight into the run-time memory activities and extract a reliable source of evidence. In this paper, we analyze the memory structure of the Schneider Electric Modicon M221 PLC. To build a memory profile, we reverse engineer the communication protocol and conduct differential analysis to gain knowledge about the structure of the memory and the low-level representation of control logic instructions. We then identify dynamic and static memory regions by modifying different project fields and conducting differential analysis, which allows us to identify boundaries of critical memory structures and extract important forensic artifacts that can be found in the memory. The Python implementation of the memory profile can help reduce the time and effort required for manual analysis in case of cyber incident or system failure.

97 MATHEMATICS AND COMPUTING↗

Resilient Hierarchical Networked Control Systems: Secure Controls for Critical Locations and at Edge

Integration of information and communication technology (ICT) offers new opportunities in improving the management and operation of critical infrastructures such as power systems as it allows connection of different sensors and control components via a communication network, leading to the so-called networked control systems (NCS). However, the use of open and pervasive ICT such as the Internet or wireless communication technologies comes at a price of making NCS vulnerable to cyber intrusions/attacks which may cause physical damage. Here, this chapter presents control algorithms to ensure resilient and safe operation of NCS under unknown cyberattacks. Specifically, a variant of dynamic watermarking strategies is presented by embedding encoding/decoding components of chaotic signals into the NCS for secure control for critical locations where the measurement/control signals are transmitted to/from the control center via a communication network. In addition, resilient cooperative control algorithms are discussed to ensure safe operation at edge of the NCS which consists of a large number of distributed controllable devices. Several numerical examples are provided to illustrate the proposed control strategies.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Nuclear Power Plant Simulation and Cybersecurity

Critical infrastructure protection is vital to the day-to-day operation of any country, and those systems need to be protected to the fullest extent possible. As with what was seen in Ukraine in late 2016, with the cyber attack on the power grid, these systems are susceptible to attacks that can cause serious damage, both physically and economically. This incident shut down the power grid for 6 hours, with nearly 80,000 people affected. Cyber security can be referred to as the protection of data and systems in networks, both wired and wireless, from unauthorized access or attack. In nuclear power plants, assessments of cyber security are critical to ensuring the safe and reliable operation of the systems used. According to the Nuclear Regulatory Commission (NRC), the purpose of cyber security assessments is to detect and then eliminate or mitigate vulnerabilities in the digital system that could be exploited either from outside or inside the digital system protected area. These cyber security assessments are essentially intended to reduce cyber security risk. The NRC refers to cyber security risk as the combination of the consequence to the nuclear power plant and the susceptibility of a digital system to internal and external cyber attack.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗