Direct Liquid Cooling for Electronic Equipment

This report documents a demonstration of an electronic-equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water-based cooling fluid into direct contact with high-heat-generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: 1) High-heat-generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less-efficient air-based data center room cooling systems. The combination contributes to the overall savings. 2) The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. 3) The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty-eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used with data center energy use modeling software to estimate overall site energy use. These estimates show that an overall data center energy savings of approximately 20 percent can be expected if a center is retrofitted as specified in the models used. Increasing the portion of heat captured by this technology is an area suggested for further development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

CFD MODELING AND ANALYSIS FOR A-AREA AND H-AREA COOLING TOWERS

Mechanical draft cooling towers are designed to cool process water via sensible and latent heat transfer to air. Heat and mass transfer take place simultaneously. Heat is transferred as sensible heat due to the temperature difference between liquid and gas phases, and as the latent heat of the water as it evaporates. Mass of water vapor is transferred due to the difference between the vapor pressure at the air-liquid interface and the partial pressure of water vapor in the bulk of the air. Equations to govern these phenomena are discussed here. The governing equations are solved by taking a computational fluid dynamics (CFD) approach. The purpose of the work is to develop a three-dimensional CFD model to evaluate the flow patterns inside the cooling tower cell driven by cooling fan and wind, considering the cooling fans to be on or off. Two types of the cooling towers are considered here. One is cross-flow type cooling tower located in A-Area, and the other is counterflow type cooling tower located in H-Area. The cooling tower located in A-Area is mechanical draft cooling tower (MDCT) consisting of four compartment cells as shown in Fig. 1. It is 13.7m wide, 36.8m long, and 9.4m high. Each cell has its own cooling fan and shroud without any flow communications between two adjacent cells. There are water distribution decks on both sides of the fan shroud. The deck floor has an array of about 25mm size holes through which water droplet falls into the cell region cooled by the ambient air driven by fan and wind, and it is eventually collected in basin area. As shown in Fig. 1, about 0.15-m thick drift eliminator allows ambient air to be humidified through the evaporative cooling process without entrainment of water droplets into the shroud exit. The H-Area cooling tower is about 7.3 m wide, 29.3 m long, and 9.0 m high. Each cell has its own cooling fan and shroud, but each of two corner cells has two panels to shield wind at the bottom of the cells. There is some degree of flow communications between adjacent cells through the 9-in gap at the bottom of the tower cells as shown in Fig. 2. Detailed geometrical dimensions for the H-Area tower configurations are presented in the figure. The model was benchmarked and verified against off-site and on-site test results. The verified model was applied to the investigation of cooling fan and wind effects on water cooling in cells when fans are off and on. This report will discuss the modeling and test results.

42 ENGINEERING↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

utility incentives↗

Improving Durability of Turbine Components Through Trenched Film Cooling and Contoured Endwalls

The experimental and computational studies of the turbine endwall and vane models completed in this research program have provided a comprehensive understanding of turbine cooling with combined film cooling and TBC. To correctly simulate the cooling effects of TBC requires the use of matched Biot number models, a technique developed in our laboratories. This technique allows for the measurement of the overall cooling effectiveness which is a measure of the combined internal and external cooling for a turbine component. The overall cooling effectiveness provides an indication of the actual metal temperature that would occur at engine conditions, and is hence a more powerful performance indicator than the film effectiveness parameter that is commonly used for film cooling studies. Furthermore these studies include the effects of contaminant depositions which are expected to occur when gas turbines are operated with syngas fuels. Results from the endwall studies performed at Penn State University and the vane model studies performed at the University of Texas are the first direct measurements of the combined effects of film cooling and TBC. These results show that TBC has a dominating effect on the overall cooling effectiveness, which enhances the importance of the internal cooling mechanisms, and downplays the importance of the film cooling of the external surface. The TBC was found to increase overall cooling effectiveness by a factor of two to four. When combined with TBC, the primary cooling from film cooling holes was found to be due to the convective cooling within the holes, not from the film effectiveness on the surface of the TBC. Simulations of the deposition of contaminants on the endwall and vane surfaces showed that these depositions caused a large increase in surface roughness and significant degradation of film effectiveness. However, despite these negative factors, the depositions caused only a slight decrease in the overall cooling effectiveness on the endwall, and in some cases a slight increase in overall cooling effectiveness on the vane model. This was attributed to the insulating effects of the depositions which compensated for the negative factors.

Bogard, David G.↗

Experimental studies of transpiration cooling with shock interaction in hypersonic flow, part B

This report describes the result of experimental studies conducted to examine the effects of the impingement of an oblique shock on the flowfield and surface characteristics of a transpiration-cooled wall in turbulent hypersonic flow. The principal objective of this work was to determine whether the interaction between the oblique shock and the low-momentum region of the transpiration-cooled boundary layer created a highly distorted flowfield and resulted in a significant reduction in the cooling effectiveness of the transpiration-cooled surface. As a part of this program, we also sought to determine the effectiveness of transpiration cooling with nitrogen and helium injectants for a wide range of blowing rates under constant-pressure conditions in the absence of shock interaction. This experimental program was conducted in the Calspan 48-Inch Shock Tunnel at nominal Mach numbers of 6 and 8, for a Reynolds number of 7.5 x 10(exp 6). For these test conditions, we obtained fully turbulent boundary layers upstream of the interaction regions over the transpiration-cooled segment of the flat plate. The experimental program was conducted in two phases. In the first phase, we examined the effects of mass-addition level and coolant properties on the cooling effectiveness of transpiration-cooled surfaces in the absence of shock interaction. In the second phase of the program, we examined the effects of oblique shock impingement on the flowfield and surface characteristics of a transpiration-cooled surface. The studies were conducted for a range of shock strengths with nitrogen and helium coolants to examine how the distribution of heat transfer and pressure and the characteristics of the flowfield in the interaction region varied with shock strength and the level of mass addition from the transpiration-cooled section of the model. The effects of the distribution of the blowing rate along the interaction regions were also examined for a range of blowing rates through the transpiration-cooled panels. The regions of shockwave/boundary layer interaction examined in these studies were induced by oblique shocks generated with a sharp, flat plate, inclined to the freestream at angles of 5 degrees, 7.5 degrees, and 10 degrees. It was found that, in the absence of an incident shock, transpiration cooling was a very effective method for reducing both the heat transfer and the skin friction loads on the surface. The helium coolant was found to be significantly more effective than nitrogen, because of its low molecular weight and high specific heat. The studies of shock-wave/transpiration-cooled surface interaction demonstrated that the interaction region between the incident shock and the low-momentum transpiration-cooled boundary layer did not result in a significant increase in the size of attached or separated interaction regions, and did not result in significant flowfield distortions above the interaction region. The increase in heating downstream of the shock-impingement point could easily be reduced to the values without shock impingement by a relatively small increase in the transpiration cooling in this region. Surprisingly, this increase in cooling rate did not result in a significant increase in size of the region ahead of the incident shock or create a significantly enlarged interaction region with a resultant increase in the distortion level in the inviscid flow. Thus, transpiration cooling appears to be a very effective technique to cool the internal surfaces of scramjet engines, where shocks in the engine would induce large local increases in wall heating and create viscous/inviscid interactions that could significantly disturb the smooth flow through the combustor. However, if hydrogen is used as the coolant, burning upstream of shock impingement might result in localized hot spots. Clearly, further research is needed in this area.

Holden, Michael S.↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemical Water Treatment for Cooling Towers

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also commonly applied to water cooled chilled water plants in medium to large commercial buildings. Cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume a large amount of water. Cooling tower related water consumption is one of largest potable water loads within buildings in the United States, with over 26% of water use associated with heating and cooling. Reducing water consumption is a priority for the General Services Administration (GSA) due to Executive Order 13514, Energy Policy Act of 1992, and regional water shortage concerns. These factors have brought about the investigation of cost effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches rely on chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment, however even when chemicals are used regularly, a certain percentage of condenser water must be blown down and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste issue and can cause building owners to incur additional fees such as disposal or sewer charges. The current state of water treatment in GSA buildings is to contract for a fixed fee with a company specializing in a conventional chemical maintenance. There are many vendors of AWT systems. This project assesses the effectiveness of one technology provided by Dynamic Water Technologies (DWT). This project assesses the effectiveness of DWT for lowering GSA operating costs while maintaining proper water treatment. The application of the DWT technology in place of traditional chemical water treatment has the anticipated benefits of: - Saving water and water/sewer costs by reducing the amount of blowdown required due to being able to remove scale causing minerals that allows the system to operate at a higher cycles of concentration - Eliminating the need for water treatment chemicals for scale, corrosion, and biological growth - Increasing chiller efficiency by preventing scaling and removing some of the existing scale, which improves heat transfer - Maintaining very low corrosion rates. The technology was installed at the Juliette Gordon Low Federal Building located in Savannah, Georgia. The building has two cooling towers utilizing traditional chemical water treatment for the cooling water circulating through the two chiller condensers. Measurement at the site includes the flow of makeup water to the cooling towers and the blowdown flow rate from the cooling tower basins. Additionally, energy measurements include the electrical energy from the chillers, chiller water pumps, condenser water pumps, cooling tower fans and the energy used by the DWT skid and slip stream pump.

15 GEOTHERMAL ENERGY↗

Integrated Turbine Component Cooling Designs Facilitated by Additive Manufacturing and Optimization

This research program involved the development of improved gas turbine cooling by optimizing the combined internal and film cooling configurations used for turbine blades and vanes. Improved cooling of turbine airfoils allows the gas turbines to be operated at higher temperatures which improves efficiency for gas turbine-based power generation. This also facilitates operation with hydrogen-based fuels which inherently generate higher operating temperatures. Designs of the new cooling configurations were based on the added geometric flexibility that is available when using metal additive manufacturing techniques. When making these designs, adjustments were made to account for imperfections occurring in the metal additive manufacturing process. New designs for film cooling holes were developed using computational adjoint gradient optimization techniques which generated a unique film cooling hole with 70% greater film cooling effectiveness compared to conventional shaped film cooling holes. A major factor in improving the film cooling effectiveness were small external protrusions on either side of the new hole which generated vortices that pushed coolant towards the surface and increased the lateral spreading of the coolant. Our studies also included optimization of film cooling holes that can be built with conventional manufacturing techniques and optimizing the internal coolant channels that supply coolant to the film cooling holes. Various internal coolant channel shapes were investigated and designs that maximized the cooling of the airfoil while minimizing pressure losses in the channel flows were identified. Testing and verification of the performance of the final configurations was done with a transonic wind tunnel facility which allowed testing at engine realistic high velocities. Final testing of the combined internal and film cooling configurations was done by incorporating the configurations in Penn State’s National Experimental Turbine (NExT) vane. These tests confirmed the enhanced overall cooling effectiveness provided by the new cooling configuration designs.

03 NATURAL GAS↗

A Multi-Center Controlled Study of the Acute and Chronic Effects of Cooling Therapy for MS

To determine the acute and chronic effects of cooling therapy on patients with MS using objective functional performance measures and self-assessed measures of fatigue. Cooling demyelinated nerves can reduce conduction block, potentially improving symptoms of MS. Significant acute and chronic effects of cooling have not been demonstrated in a multi-center, controlled, blinded study using objective measures of neurologic function. Patients (N=84) with definite MS, mild to moderate disability (EDSS less than 6.0), and self-reported heat sensitivity were enrolled at 5 study sites. Acute effects of cooling were assessed by randomly assigning subjects to high-dose or low-dose cooling for one hour using an active cooling vest and cap (Life Enhancement Technologies, Santa Clara, CA). Settings were individualized to maintain the cooling garments at 55 F for the high-dose treatment and 70 F for the low-dose treatment. Both patients and examining investigators were blinded to treatment assignments. The MSFC and visual acuity/contrast sensitivity were assessed before and 30 minutes after treatment. The following week, subjects had an identical visit with the alternate cooling treatment. Chronic effects of cooling were assessed by randomly assigning the same subjects to unblinded daily home cooling or observation for 4 weeks. All subjects completed the Rochester Fatigue Diary (RFD) twice weekly and subjective measures of strength, cognition, and energy level daily. At the end of the period, subjects completed the Modified Fatigue Impact Scale (MFIS) and underwent another high-dose cooling session with assessment of the MSFC and vision. After a one-week washout period, subjects crossed over to the alternate 4-week treatment. Oral temperatures were reduced with both acute treatments (0.8 +/- .06 F, high and 0.5 +/- .06 F, low). While mean MSFC did not change significantly during individual cooling sessions, post hoc analysis pooling the 3 high-dose cooling sessions revealed an improvement in MSFC scores (acute phase 0.064 +/- 0.020, p = 0.0013; chronic phase 0.044 +/- 0.021, p = 0.0368) from before to after cooling. The change in MSFC scores during the acute cooling sessions was not related to the extent of change in oral temperatures. Both the RFD score and the MFIS indicate a significantly lower fatigue level during the cooling month compared to observation (RFD, 2.53 +/- 0.83,p = 0.0033; MFIS 7.63 +/- 1.56, p = 0.0001).

Luna, Bernadette↗

State-of-the-Art Cooling Technology for a Turbine Rotor Blade

Effective internal and external cooling of airfoils is key to maintaining component life for efficient gas turbines. Cooling designs have spanned the range from simple internal convective channels to more advanced double-walls with shaped film-cooling holes. This paper describes the development of an internal and external cooling concept for a state-of-the-art cooled turbine blade. These cooling concepts are based on a review of literature and patents, as well as, interactions with academic and industry turbine cooling experts. The cooling configuration selected and described in this paper is referred to as the “baseline” design, since this design will simultaneously be tested with other more advanced blade cooling designs in a rotating turbine test facility using a “rainbow turbine wheel” configuration. For the baseline design, the leading edge is cooled by internal jet impingement and showerhead film cooling. The midchord region of the blade contains a three-pass serpentine passage with internal discrete V-shaped trip strips to enhance the internal heat transfer coefficient (HTC). The film cooling along the midchord of the blade uses multiple rows of shaped diffusion holes. Furthermore, the trailing edge is internally cooled using jet impingement and externally film cooled through partitioned cuts on the pressure side of the blade.

01 COAL, LIGNITE, AND PEAT↗

Effect of cooling conditions on microstructure and mechanical properties of friction stir welded 7055 aluminium alloy joints

Highlights: • Water cooling improves tensile properties of friction stir welded 7055 Al alloy. • Water cooling results in smaller grains and second phase in nugget zone. • Water cooling results in finer second phase in thermos-mechanically affected zone. • Water cooling results in finer second phase in heat affected zone. • Fracture surface is flat for air-cooled joint but zig-zag for water-cooled one. - Abstract: The microstructure and mechanical properties of friction stir welded 7055 aluminium alloy under air cooling and water cooling were investigated by means of hardness and tensile testing, optical microscopy and transmission electron microscopy. Water cooling results in reduced softening in the weld zone and therefore higher tensile strength compared to air cooling. Fracture generally occurs within the thermo-mechanically affected zone (TMAZ) and heat affected zone (HAZ) on the retreating side in joints welded under air cooling but shifts towards the TMAZ and nugget zone (NZ) in the joints welded under water cooling. The fracture surfaces are generally flat for the air-cooled joint, but exhibits a zig-zag feature for the water-cooled joint. The mechanical behaviour of the weld has been discussed in light of the change in grain structure and precipitation in the NZ, TMAZ and HAZ caused by cooling conditions.

36 MATERIALS SCIENCE↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗