Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Design and modelling of the photonic crystal fano structure for all optical switching applications

In this paper, the optical Fano switch based on the 2D slab photonic crystal is analyzed. Switching characteristics are improved by manipulating the Q factors of cavities. Modified device with enhanced Fano resonance has lower energy consumption than other previous optical switches. Results show that, the switching contrast is enhanced while the quality factor has remained in its highest value. Therefore, the typical important trade off between switching contrast and quality factor has vanished in the modified structure. The switching contrast is improved from 7 to 34 db in constant Δλ{sub peak−peak} of 0.3 nm in the modified structure which leads to decreasing the energy consumption of the device. In the previous devices, the maximum reported contrast is about 20 db for Δλ{sub peak−peak} of 0.6 nm. A coupled mode theory for analyzing the structure is developed. The results of finite difference time domain numerical simulation are in good agreement with the theoretical coupled mode theory. Results show that the switching contrast of the modified Fano switch is enhanced two times, consequently the loss is suppressed and the bandwidth is improved.

36 MATERIALS SCIENCE↗

The application of synchrotron micro-computed tomography to characterize the three-dimensional microstructure in irradiated nuclear fuel

This research demonstrated the first time that synchrotron X-ray micro-computed tomography (μ-CT) was utilized to analyze the three-dimensional (3-D) morphology of the microstructure of irradiated nuclear fuel. Both absorption contrast and propagation-based phase contrast enhanced μ-CT techniques were evaluated. Porosity and phase region volumes were determined in neutron irradiated uranium 10 wt.% zirconium (U-10Zr) using propagation-based phase contrast enhanced μ-CT. Volumes were determined by image processing software and algorithms, with the porosity volume subsequently compared to the ASTM E562 method. The 3-D porosity of a small region (~ 8 x 10 5 µm 3 ) located in the intermediate fuel redistribution zone that was removed via a focused ion beam was determined to be 7.2% via image processing. A detailed 3-D analysis of the porosity with respect to volume and morphology was provided. Five growth stages of pore evolution were observed including: nucleation, growth, coalescence, interconnected porosity, and extended/interconnected porosity. Four distinct phase regions were identified, including the pores, via both absorption contrast and propagation-based phase contrast enhanced μ-CT. A quantitative comparison of fuel swelling between this localized microscopic U-10Zr fuel region, previously irradiated in the Fast Flux Test Facility, and historic U-10Zr fuels irradiated in the Experimental Breeder Reactor-II (EBR-II) was conducted. It was determined that for similar burnups, the localized swelling in this microscopic fuel region was 7.7%, which was approximately one-half of the value of the macroscopic swelling reported in EBR-II irradiated fuel. With the advent of new specimen preparation tools for irradiated materials, as well as advances in characterization techniques, researchers can now obtain previously inaccessible microstructural insight into irradiated fuels. This possibility naturally lends itself to improved fuel performance models for the nuclear community.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Variable Continuous Bimaterial Interface in the San Jacinto Fault Zone Revealed by Dense Seismic Array Analysis of Fault Zone Head Waves

Key factors controlling earthquake ruptures include fault geometry, continuity, and seismic velocity structure around the fault. We present a novel tool that better informs deep bimaterial fault geometry embedded in distributed damage and seismicity, associated velocity contrasts across the fault, and their correlations with surface complexities. The method employs fault zone head and direct body waves and is applied to recordings from five spatiotemporally different seismic arrays along the complex San Jacinto fault zone (SJFZ) in southern California. We detect and distinguish these signals based on instantaneous phase coherence and relative energy in a cascading manner from one scale array to another. The analysis reveals a >70-km long continuous bimaterial interface within the SJFZ with several deep northeast dipping fault segments. The northern SJFZ, for instance, locates ~7 km northeast of its surface expression at 18-km depth. P-wave velocity contrasts range from near 0% to >15%, consistent with other bimaterial faults, and differ by a few % depending on fault-array azimuth, implying directional-dependent velocity contrasts. S-wave head waves and velocity contrasts are also imaged for the first time at the southern SJFZ, averaging to 2.9% in agreement with tomography results. The imaged geometry and continuity suggest the SJFZ initiated along remnant tectonic structures and translates to a rupture potential of M > 7.2, i.e., the sizes of its largest paleo-earthquakes. The P and S contrasts, and their ratios, have important implications for earthquake rupture speed, mode, directivity, and frictional heating along the SJFZ and other major faults globally.

58 GEOSCIENCES↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Pictorial review on abdominal applications of ferumoxytol in MR imaging

Though gadolinium-based contrast agents are the most widely used contrast media in MR for clinical use, problems with nephrogenic systemic fibrosis and tissue deposition render their safety debatable, at least in a selected patient population. Ferumoxytol has the potential to be used as an alternate contrast medium for various clinical applications across multiple organs. It has prolonged intravascular signal and delayed intracellular macrophage uptake which are unique properties compared to gadolinium-based agents. This pictorial review aims to review the current and potential clinical applications of ferumoxytol as a contrast agent in abdominal MR imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Utilizing ink composition to tune bulk-electrode gas transport, performance, and operational robustness for a Fe-N-C catalyst in polymer electrolyte fuel cell

With lower site density and turnover frequency, platinum group metal (PGM)-free catalysts based electrodes are often greater than 50 mu m thick in order to increase performance across the fuel cell operating range. Consequently, PGM-free electrodes have an additional bulk electrode transport resistance beyond the local or aggregate level transport in thin platinum-based electrodes. In parallel to the development of more active and durable PGM-free catalysts, advancements in understanding the interplay between PGM-free electrode fabrication, bulk-electrode transport, proton conductivity and performance are needed. Here, the relationship between ionic and gas phase transport through the electrode thickness is modified by adjusting electrocatalyst and ionomer flocculation/interaction at the ink level. The influence of the ink composition (water/n-propanol content) is examined via various in-situ electrochemical and ex-situ characterization techniques and the resulting electrode structure/performance relationship contrasted with electrode performance robustness across a range of relative humidity (RH). For the electrocatalyst examined here, a water-rich (82 wt% H2O) ink formulation was favorable for operation at high RH due to improved molecular diffusion through larger electrode pores. In contrast, the improved interactions between ionomer and electrocatalyst enabled a more robust electrode and higher performance during low RH operation for the 50 wt% H2O content ink.

08 HYDROGEN↗

Heliostat optical error inspection with polarimetric imaging drone

On a Concentrated Solar Power (CSP) field, optical errors have significant impacts on the collection efficiency of heliostats. Fast, cost-effective, labor-efficient, and non-intrusive autonomous field inspection remains a challenge. Approaches using imaging drone, i.e., Unmanned Aerial Vehicle (UAV) system integrated with high resolution visible imaging sensors, have been developed to address these challenges; however, these approaches are often limited by insufficient imaging contrast. Here, in this study, we report a polarimetry-based method with a polarization imaging system integrated on UAV to enhance imaging contrast for in-situ detection of heliostat mirrors without interrupting field operation. We developed an optical model for skylight polarization pattern to simulate the polarization images of heliostat mirrors and obtained optimized waypoints for polarimetric imaging drone flight path to capture images with enhanced contrast. The polarimetric imaging-based method improved the success rate of edge detections in scenarios which were challenging for mirror edge detection with conventional imaging sensors. We have performed field tests to achieve significantly enhanced heliostat edge detection success rate and investigate the feasibility of integrating polarimetric imaging method with existing imaging-based heliostat inspection methods, i.e., Polarimetric Imaging Heliostat Inspection Method (PIHIM). Our preliminary field test results suggest that the PIHIM hold the promise to enable sufficient imaging contrast for real-time autonomous imaging and detection of heliostat field, thus suitable for non-interruptive fast CSP field inspection during its operation.

CSP Field↗

Automated Quantitative Analysis of Extended Irradiation Defects - Dislocations, Voids and Precipitates in Neutron Irradiated HT-9 Steel

Structural alloys that make up the core components of nuclear reactors are exposed to radiation that can substantially alter the microstructure and mechanical properties of the material. Irradiation can cause the formation of extended defects including dislocation line and loops, voids and various types of precipitates. To understand the irradiation effects, it is critical to characterize these defects individually and collectively to quantify how they evolve throughout irradiation stages. Transmission electron microscopy (TEM) is a standard tool for providing extensive size, number density and spatial distribution of extended irradiation defects, however, manual measurement of defect size and number density requires time-intensive effort to analyze enough defects that provide a statistically meaningful result and are prone to errors of subjectivity. In this work, we developed a set of MATLAB algorithms offering robust and automated identification and quantification of extended irradiation defects like dislocation lines, voids and precipitates commonly observed in neutron irradiated cladding alloys [1]. Using a neutron-irradiated HT-9 martensitic alloy irradiated at 412°C to 111.8 dpa, we demonstrate the capability of these algorithms for quantitative defect analysis. Figure 1 presents defect images of the HT-9 using an advanced diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) that suppresses bend contours and provides better defect contrast compared to conventional TEM [2]. The first step of defect analysis is defect identification, a process that can be digitally achieved by contrast thresholding (for simple defect contrast) and by machine learning computer vision for defect semantic segmentation [3]. Here, labeled binary defect images (Figures 2a and 2c) were used. For dislocation density quantification, we employed an optimized circular-grid intersection method first introduced by Dr. John Steeds [4]. This method is shown in Figures 2a and 2b, where the number of intersections of dislocation lines with circular traces was measured. This produces an unbiased sampling of dislocation lines, regardless of their orientation. This process was optimized with automated digital intersection number and grid length registration. Interestingly, it was found that a relatively large number of circles in a set circular gird is was needed to produce an invariant result (Figure 2b), with a low systematic measurement error. This demonstrates the main advantage of computer-based defect analysis, in performing repetitive operations quickly with a reduced systematic error. For the quantitative analysis of voids and precipitates a challenge encountered with automated defect analysis is feature overlap, particularly when the density of voids/precipitates is high. To mitigate this problem, as shown in Figure 2d, we modified the popular circular Hough transformation and treated ‘circular shape’ as the particle descriptor for voids/precipitates, efficiently resolving the overlapping particles. In summary, this automated digital quantification together with machine learning enabled defect identification [3] opens new opportunities for standardizing the characterization workflow for quantitative analysis of extended irradiation defects.

Sainju, Rajat↗

Understanding the Influence of Receptive Field and Network Complexity in Neural Network-Guided TEM Image Analysis

Abstract Trained neural networks are promising tools to analyze the ever-increasing amount of scientific image data, but it is unclear how to best customize these networks for the unique features in transmission electron micrographs. Here, we systematically examine how neural network architecture choices affect how neural networks segment, or pixel-wise separate, crystalline nanoparticles from amorphous background in transmission electron microscopy (TEM) images. We focus on decoupling the influence of receptive field, or the area of the input image that contributes to the output decision, from network complexity, which dictates the number of trainable parameters. For low-resolution TEM images which rely on amplitude contrast to distinguish nanoparticles from background, we find that the receptive field does not significantly influence segmentation performance. On the other hand, for high-resolution TEM images which rely on both amplitude and phase-contrast changes to identify nanoparticles, receptive field is an important parameter for increased performance, especially in images with minimal amplitude contrast. Rather than depending on atom or nanoparticle size, the ideal receptive field seems to be inversely correlated to the degree of nanoparticle contrast in the image. Our results provide insight and guidance as to how to adapt neural networks for applications with TEM datasets.

42 ENGINEERING↗

Structure of Diisobutylene Maleic Acid Copolymer (DIBMA) and Its Lipid Particle as a “Stealth” Membrane-Mimetic for Membrane Protein Research

The study of membrane proteins remains challenging, especially in a native membrane environment. Recently, major progress has been made using maleic acid copolymers, such as styrene maleic acid, to purify membrane proteins and study them directly with native lipids associated with the membrane. Additional maleic acid copolymers, such as diisobutylene maleic acid (DIBMA) membrane-mimetic systems, are being developed and found to have improved spectroscopic properties and pH stability. We studied DIBMA and its lipid particles in solution to better understand its assembly, without and with the lipids, to provide an insight regarding how to use it in solution for better membrane extraction. Using small-angle neutron and X-ray scattering (SANS/SAXS), we show that DIBMA organizes into structures of different size scales at various concentrations and ionic strengths. The polymer performed reasonably well under most solvent conditions except in very low concentrations and high-salt conditions that could result in limited interaction with lipids. To explore DIBMA lipid particles as a suitable membrane-mimetic system for neutron scattering studies of membrane proteins, we measured and determined the contrast-matching point of DIBMA to be ~12% (v/v) D 2 O — similar to that of most protiated lipid molecules but distinct from that of regular protiated proteins — providing a natural contrast for separating their neutron scattering signals. Using SANS contrast variation, we demonstrated that the scattering from the whole lipid particle can be annihilated. Further, we determined that a well-defined lipid nanodisc structure with DIBMA was contrast-matched. These results demonstrate that the DIBMA lipid particle is an outstanding “stealth” membrane-mimetic for membrane proteins. The results provide a structural framework for understanding the organization and assembly process of the polymer itself and the lipid molecules. Such an understanding is imperative for structural techniques such as cryo-electron microscopy, nuclear magnetic resonance, small-angle scattering, and other biophysical techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulating a Mesoscale Convective System Using WRF with a New Spectral Bin Microphysics: Part 1: Hail vs Graupel

A modified Fast Spectral Bin Microphysics scheme (FSBM-2) embedded into the Weather Research and Forecasting Model (WRF) is used to simulate a mesoscale deep convective system observed during the Midlatitude Continental Convective Clouds Experiment (MC3E). FSBM-2 uses modified source codes as compared to the current FSBM (FSBM-1). In contrast to FSBM-1, FSBM-2 can simulate hail of several cm in diameter and includes additional processes such as spontaneous breakup of raindrops and aerosol regeneration by drop evaporation. It is shown that allowing large hail particles of diameters exceeding about 1 cm substantially increases the agreement between the simulated and observed squall-line structures both in the convective and stratiform regions. In contrast, if graupel particles are used to represent high-density hydrometeors in convective areas, the ratio of convective-to-stratiform areas diverges from the ratio seen in observations and maximum radar reflectivities are substantially underestimated. Analysis of snow size distributions in the stratiform area shows an important link between the ice crystals formed by homogeneous freezing in the convective area to ice particle number concentration in the stratiform region. Simulated raindrop size distributions in the stratiform area below the melting level from FSBM-2 show a good agreement with observations. The regeneration of CCN by droplet evaporation and detrainment of these CCN to the stratiform region increases the concentration of CCN there up to 8-9 km altitude; the additional CCN penetrate clouds and produce new droplets, leading to some convection intensification. Key words: Mesoscale convective systems (MCS), squall lines, spectral bin microphysics, large hail, in-cloud nucleation, size distributions of hydrometeors in MCS.

Shpund, Kobby↗

2D-to-3D image translation of complex nanoporous volumes using generative networks

Image-based characterization offers a powerful approach to studying geological porous media at the nanoscale and images are critical to understanding reactive transport mechanisms in reservoirs relevant to energy and sustainability technologies such as carbon sequestration, subsurface hydrogen storage, and natural gas recovery. Nanoimaging presents a trade off, however, between higher-contrast sample-destructive and lower-contrast sample-preserving imaging modalities. Furthermore, high-contrast imaging modalities often acquire only 2D images, while 3D volumes are needed to characterize fully a source rock sample. In this work, we present deep learning image translation models to predict high-contrast focused ion beam-scanning electron microscopy (FIB-SEM) image volumes from transmission X-ray microscopy (TXM) images when only 2D paired training data is available. We introduce a regularization method for improving 3D volume generation from 2D-to-2D deep learning image models and apply this approach to translate 3D TXM volumes to FIB-SEM fidelity. We then segment a predicted FIB-SEM volume into a flow simulation domain and calculate the sample apparent permeability using a lattice Boltzmann method (LBM) technique. Results show that our image translation approach produces simulation domains suitable for flow visualization and allows for accurate characterization of petrophysical properties from non-destructive imaging data.

58 GEOSCIENCES↗

Progress in the development of an ultrafast pulsed ponderomotive phase plate for cryo-electron tomography

Cryo-electron tomography (cryo-ET) is a powerful modality for resolving cellular structures in their native state. While single-particle cryo-electron microscopy excels in determining protein structures purified from recombinant or endogenous sources due to an abundance of particles, weak contrast issues are accentuated in cryo-ET by low copy numbers in crowded cellular milieux. Continuous laser phase plates offer improved contrast in cryo-ET; however, their implementation demands exceptionally high-peak optical intensities. Instead, a novel experimental approach to enhance contrast in cryo-ET is to manipulate the phase of scattered pulsed electrons using ultrafast pulsed photons. Here, we outline the experimental design of a proof-of-concept electron microscope and demonstrate synchronization between electron packets and laser pulses. Furthermore, we show ultrabright photoemission of electrons from an alloy field emission tip using femtosecond ultraviolet pulses. These experiments pave the way toward exploring the utility of the ponderomotive effect using pulsed radiation to increase phase contrast in cryo-ET of subcellular protein complexes in situ, thus advancing the field of cell biology.

Du, Daniel X. [Columbia Univ., New York, NY (Unite↗

Multislice Electron Tomography Using Four-Dimensional Scanning Transmission Electron Microscopy

Electron tomography offers useful three-dimensional (3D) structural information, which cannot be observed by two-dimensional imaging. By combining annular dark-field scanning transmission electron microscopy (ADF STEM) with aberration correction, the resolution of electron tomography has reached atomic resolution. However, tomography based on ADF STEM inherently suffers from several issues, including a high electron-dose requirement, poor contrast for light elements, and artifacts from image-contrast nonlinearity. Here, we develop an alternative method called multislice electron tomography (MSET) based on four-dimensional STEM tilt series. In this study, our simulations show that multislice-based 3D reconstruction can effectively reduce undesirable reconstruction artifacts from the nonlinear contrast, allowing precise determination of atomic structures with improved sensitivity for low-Z elements, at considerably low electron-dose conditions. We expect that the MSET method can be applied to a wide variety of materials, including radiation-sensitive samples and materials containing light elements whose 3D atomic structures have never been fully elucidated due to electron-dose limitations or nonlinear imaging contrast.

74 ATOMIC AND MOLECULAR PHYSICS↗

Achieving a near-ideal silicon crystal neutron interferometer using submicrometer fabrication techniques

Perfect-crystal neutron interferometry, which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two-step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, nonetching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution. Published by the American Physical Society 2024

Huber, M. G. (ORCID:0000000237958445)↗

Aberration-corrected STEM imaging of 2D materials: Artifacts and practical applications of threefold astigmatism

High-resolution scanning transmission electron microscopy (HR-STEM) with spherical aberration correction enables researchers to peer into two-dimensional (2D) materials and correlate the material properties with those of single atoms. The maximum intensity of corrected electron beam is confined in the area having sub-angstrom size. Meanwhile, the residual threefold astigmatism of the electron probe implies a triangular shape distribution of the intensity, whereas its tails overlap and thus interact with several atomic species simultaneously. The result is the resonant modulation of contrast that interferes the determination of phase transition of 2D materials. Here, we theoretically reveal and experimentally determine the origin of resonant modulation of contrast and its unintended impact on violating the power-law dependence of contrast on coordination modes between transition metal and chalcogenide atoms. The finding illuminates the correlation between atomic contrast, spatially inequivalent chalcogenide orientation, and residual threefold astigmatism on determining the atomic structure of emerging 2D materials.

36 MATERIALS SCIENCE↗

RASER MRI: Magnetic resonance images formed spontaneously exploiting cooperative nonlinear interaction

The spatial resolution of magnetic resonance imaging (MRI) is limited by the width of Lorentzian point spread functions associated with the transverse relaxation rate 1/T 2 * . Here, we show a different contrast mechanism in MRI by establishing RASER (radio-frequency amplification by stimulated emission of radiation) in imaged media. RASER imaging bursts emerge out of noise and without applying radio-frequency pulses when placing spins with sufficient population inversion in a weak magnetic field gradient. Small local differences in initial population inversion density can create stronger image contrast than conventional MRI. This different contrast mechanism is based on the cooperative nonlinear interaction between all slices. On the other hand, the cooperative nonlinear interaction gives rise to imaging artifacts, such as amplitude distortions and side lobes outside of the imaging domain. Contrast mechanism and artifacts are explored experimentally and predicted by simulations on the basis of a proposed RASER MRI theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗