Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Thermal regulation of batteries

A battery thermal management system for an air vehicle includes a first heat exchange circuit, a battery in thermal communication with the first heat exchange circuit, and a heat exchanger positioned on the first heat exchange circuit. The heat exchanger is operatively connected to a second heat exchange circuit. The system includes a controller operatively connected to the second heat exchange circuit. The controller is configured to variably select whether heat will be rejected to the second heat exchange circuit. A method for controlling a thermal management system for an air vehicle includes determining an expected fluid temperature of fluid in a fluid heat exchange circuit. The method includes commanding a flow restrictor at least partially closed or commanding the flow restrictor at least partially open.

Macdonald, Malcolm↗

Sealion Database: Tracking and Characterization of Legacy Wastes

The Radioactive Scrap and Waste Facility Liner-by-Liner Characterization Project was initiated to support waste management planning and disposition activities at the Materials and Fuels Complex located at the Idaho National Laboratory. The project scope consisted of a detailed examination of available historical records to consolidate information and eliminate discrepancies between sources. This information was captured in a new comprehensive searchable online database dubbed Sealion (Searchable Liner Online). For each storage liner and associated waste container, Sealion tracks the physical configuration, radiological data (e.g., source term, transuranic content, fissile content, and direct gamma radiation reading), Resource Conservation and Recovery Act characterization data, contents descriptions, and a variety of other waste management data. Historical hard-copy records were scanned and are stored in the database for easy access. In addition to storing the consolidated data in a library for easy retrieval or linking, Sealion serves as a tool in the development of batching plans for retrieving, transporting, processing, and, ultimately, dispositioning the waste. An integral search function allows the user to query for a variety of parameters in order to plan custom batches and account for facility or regulatory limitations (e.g., U.S. Department of Transportation limits, hazard category determinations, and fissile gram equivalent limitations). Liners can be combined or batched together and the combined results displayed in real-time graphs and tables showing the cumulative characteristics. The basic database architecture has proven to be adaptable to a variety of other similar applications. Sealion is capable of tracking segmented inventories (i.e., the liners can be replaced with storage drums, racks in a warehouse, or grids overlaid on a landfill). Additionally, the batching functions allow for the ability to combine inventory sub-locations into real-time graphs that summarize the characteristics of the contents for ease in comparison of characteristics to established thresholds or decision-making modeling needed to support waste-management operations.

99 GENERAL AND MISCELLANEOUS↗

Observation and Responses to Post-Closure Instances of Localized Instability and Subsidence at the DOE Legacy Management Rocky Flats Site, Colorado-13052

The former Rocky Flats Plant in Colorado began operations as part of the nation's nuclear weapons complex in the early 1950's. By the 1980's the associated heavily industrialized area covered approximately 1.2 km{sup 2} (300 acres) and was surrounded by an approximately 25.3 km{sup 2} (6,245 acre) security buffer zone. The federally owned property and adjacent offsite areas were placed on the CERCLA National Priority List in 1989. To complete closure, all buildings and other structures that composed the Rocky Flats industrial complex were removed from the surface, but remnants remain in the subsurface. Contouring and grading to return the surface to approximate conditions that were present prior to the plant's construction was completed in 2005. A goal of the final land configuration was to provide long-term surface and subsurface land stability. Several instances of localized surface subsidence or instability have occurred since the final configuration. The localized nature and the relatively small areas of observed subsidence and instability indicate that, overall, the final configuration is performing well, but responses to these occurrences and the observations that followed may be useful in planning for the closure and designing the final land configuration and post-closure monitoring at other sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

A two-stage optical fusion framework for wildfire severity mapping across the conterminous United States

Accurate wildfire severity mapping (WSM) is essential for post-fire recovery planning, erosion risk assessment, ecosystem monitoring, and disaster risk reduction. Although Landsat and Sentinel optical imagery have been widely used for burn severity assessment, the added value of fusing multiple optical sensors has not been sufficiently quantified across diverse fire events, particularly since the launch of Landsat-9. This study evaluates whether multisensor optical fusion improves wildfire severity mapping relative to single-sensor baselines using Sentinel-2, Landsat-8, and Landsat-9 imagery across 40 wildfire events in the conterminous United States. We tested a two-stage fusion framework that combines feature-level fusion with pixel-level dimensionality reduction. First, feature-level fused datasets were created through early fusion by combining standardized post-fire bands from each sensor into a single predictor stack. Both raw reflectance bands and pairwise spectral transforms were retained to capture within- and cross-sensor spectral interactions. Second, Linear Discriminant Analysis was applied to both single-sensor and fused datasets to produce comparable low-dimensional feature spaces. Six machine-learning classifiers were then used to benchmark model performance with repeated spatially buffered train–test splits. Results show that Landsat-9 was the strongest single-sensor baseline. Among the fusion strategies, Sentinel-2 + Landsat-9 produced the most consistent improvement and reduced performance variability. Landscape-condition analysis further showed that this fusion was most beneficial in shrubland-dominated and high-terrain fires, where it achieved the highest overall mean accuracy and the fewest failures. In contrast, its benefits were less reliable in evergreen forests, mixed vegetation, and low- to moderate-elevation terrain. In operational settings, the Sentinel-2 + Landsat-9 configuration offers a practical solution for post-fire recovery planning, erosion-risk assessment, watershed management, and ecological monitoring when field observations are available and timely satellite-based information is needed.

Landsat↗

Recent evolutions in the LTDP CDF project

In the latest years, CNAF (the national center of the Italian Institute for Nuclear Physics INFN dedicated to Research and Development on Information and Communication Technologies) has been working on the Long Term Data Preservation (LTDP) project for the CDF experiment, active at Fermilab from 1990 to 2011. The main aims of the project are to protect the most relevant part of the CDF RUN-2 data collected between 2001 and 2011 and already stored on tape at CNAF (4 PB), as well as to ensure the availability and the access to the analysis facility to those data over time. Lately, the CDF database, hosting information about CDF datasets such as their structure, file locations and metadata, has been imported from Fermilab to CNAF. Also, the Sequential Access via Metadata (SAM) station data handling tool for CDF data management, that allows to manage data transfers and to retrieve information from the CDF database, has been properly installed and configured at CNAF. This was a fundamental step in the perspective of a complete decommissioning of CDF services on Fermilab side. An access system has been designed and tested to submit CDF analysis jobs, using CDF software distributed via CERN Virtual Machine File System (CVMFS) and requesting delivery of CDF files stored on CNAF tapes, as well as data present only on Fermilab storage archive. Moreover, the availability and the correctness of all CDF data stored on CNAF tapes has been verified. This paper describes all these recent evolutions in detail, presenting the future plans for the LTDP project at CNAF.

Fornari, Federico↗

ML-based calibration and control of the GlueX Central Drift Chamber

The GlueX Central Drift Chamber (CDC) in Hall D at Jefferson Lab, used for detecting and tracking charged particles, is calibrated and controlled during data taking using a Gaussian process. The system dynamically adjusts the high voltage applied to the anode wires inside the chamber in response to changing environmental and experimental conditions such that the gain is stabilized. Control policies have been established to manage the CDC's behavior. These policies are activated when the model's uncertainty exceeds a configurable threshold or during human-initiated tests during normal production running. Finally, we demonstrate the system reduces the time detector experts dedicate to calibration of the data offline, leading to a marked decrease in computing resource usage without compromising detector performance.

47 OTHER INSTRUMENTATION↗

WIST: toolkit for rapid, customized LIMS development

Workflow Information Storage Toolkit (WIST) is a set of application programming interfaces and web applications that allow for the rapid development of customized laboratory information management systems (LIMS). WIST provides common LIMS input components, and allows them to be arranged and configured using a flexible language that specifies each component’s visual and semantic characteristics. WIST includes a complete set of web applications for adding, editing and viewing data, as well as a powerful setup tool that can build new LIMS modules by analyzing existing database schema.

59 BASIC BIOLOGICAL SCIENCES↗

Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy

Purpose: Real-time tracking of implanted fiducials in cine megavoltage (MV) imaging during volumetric modulated arc therapy (VMAT) delivery is complicated due to the inherent low contrast of MV images and potential blockage of dynamic leaves configurations. The purpose of this work is to develop a clinically practical autodetection algorithm for motion management during VMAT. Methods: The expected field-specific segments and the planned fiducial position from the Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system were projected onto the MV images. The fiducials were enhanced by applying a Laplacian of Gaussian filter in the spatial domain for each image, with a blob-shaped object as the impulse response. The search of implanted fiducials was then performed on a region of interest centered on the projection of the fiducial when it was within an open field including the case when it was close to the field edge or partially occluded by the leaves. A universal template formula was proposed for template matching and normalized cross correlation was employed for its simplicity and computational efficiency. The search region for every image was adaptively updated through a prediction model that employed the 3D position of the fiducial estimated from the localized positions in previous images. This prediction model allowed the actual fiducial position to be tracked dynamically and was used to initialize the search region. The artifacts caused by electronic interference during the acquisition were effectively removed. A score map was computed by combining both morphological information and image intensity. The pixel location with the highest score was selected as the detected fiducial position. The sets of cine MV images taken during treatment were analyzed with in-house developed software written in MATLAB (The Mathworks, Inc., Natick, MA). Five prostate patients were analyzed to assess the algorithm performance by measuring their positioning accuracy during treatment. Results: The algorithm was able to accurately localize the fiducial position on MV images with success rates of more than 90% per case. The percentage of images in which each fiducial was localized in the studied cases varied between 23% and 65%, with at least one fiducial having been localized between 40% and 95% of the images. This depended mainly on the modulation of the plan and fiducial blockage. The prostate movement in the presented cases varied between 0.8 and 3.5 mm (mean values). The maximum displacement detected among all patients was of 5.7 mm. Conclusions: An algorithm for automatic detection of fiducial markers in cine MV images has been developed and tested with five clinical cases. Despite the challenges posed by complex beam aperture shapes, fiducial localization close to the field edge, partial occlusion of fiducials, fast leaf and gantry movement, and inherently low MV image quality, good localization results were achieved in patient images. This work provides a technique for enabling real-time accurate fiducial detection and tumor tracking during VMAT treatments without the use of extra imaging dose.

60 APPLIED LIFE SCIENCES↗

SSP Personality Programmer

The Personality Programmer software is used as means for entities to configure, deploy, and redeploy SSP devices. SAND2020-14337 O Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hunt, TannerR.↗

Small Column Ion Exchange

Thomas Huff of SRS: Savannah River Remediation gives an in-depth look at Small Column Ion Exchange (SCIX) technology. The impact of SCIX is discussed along with its history, processes, and future development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MONTE-CARLO BURNUP CALCULATION UNCERTAINTY QUANTIFICATION AND PROPAGATION DETERMINATION

Reactor burnup or depletion codes are used thoroughly in the fields of nuclear forensics and nuclear safeguards. Two common codes include MONTEBURNS and MCNPX/CINDER. These are Monte-Carlo depletion routines utilizing MCNP for neutron transport calculations and either ORIGEN or CINDER for burnup calculations. Uncertainties exist in the MCNP steps, but this information is not passed to the depletion calculations or saved. To quantify this transport uncertainty and determine how it propagates between burnup steps, a statistical analysis of multiple repeated depletion runs is performed. The reactor model chosen is the Oak Ridge Research Reactor (ORR) in a single assembly, infinite lattice configuration. This model was burned for a 150 day cycle broken down into three steps. The output isotopics as well as effective multiplication factor (k-effective) were tabulated and histograms were created at each burnup step using the Scott Method to determine the bin width. The distributions for each code are a statistical benchmark and comparisons made. It was expected that the gram quantities and k-effective histograms would produce normally distributed results since they were produced from a Monte-Carlo routine, but some of the results appear to not. Statistical analyses are performed using the {chi}{sup 2} test against a normal distribution for the k-effective results and several isotopes including {sup 134}Cs, {sup 137}Cs, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 238}Pu, {sup 239}Pu, and {sup 240}Pu.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design Concept for a Compact ERL to Drive a VUV/Soft X-Ray FEL

We explore possible upgrades of the existing Jefferson Laboratory IR/UV FEL driver to higher electron beam energy and shorter wavelength through use of multipass recirculation to drive an amplifier FEL. The system would require beam energy at the wiggler of 600 MeV with 1 mA of average current. The system must generate a high brightness beam, configure it appropriately, and preserve beam quality through the acceleration cycle ? including multiple recirculations ? and appropriately manage the phase space during energy recovery. The paper will discuss preliminary design analysis of the longitudinal match, space charge effects in the linac, and recirculator design issues, including the potential for the microbunching instability. A design concept for the low energy recirculator and an emittance preserving lattice solution will be presented.

43 PARTICLE ACCELERATORS↗

NGNP Risk Management through Assessing Technology Readiness

Throughout the Next Generation Nuclear Plant (NGNP) project life cycle, technical risks are identified, analyzed, and mitigated and decisions are made regarding the design and selection of plant and sub-system configurations, components and their fabrication materials, and operating conditions. Risk resolution and decision making are key elements that help achieve project completion within budget and schedule constraints and desired plant availability. To achieve this objective, a formal decision-making and risk management process was developed for NGNP, based on proven systems engineering principles that have guided aerospace and military applications.

42 ENGINEERING↗

Comparative analysis of thermal management systems in electric vehicles at extreme weather conditions: Case study on Nissan Leaf 2019 Plus, Chevrolet Bolt 2020 and Tesla Model 3 2020

With the surge in electric vehicle (EV) adoption and the need for extended driving ranges, optimizing energy efficiency, particularly through thermal management, is critical, especially in extreme weather. Managing the substantial energy needed for cabin climate control and battery temperature regulation can increase energy demands by over 50 %, severely limiting range. This study conducts a comparative analysis of thermal management systems (TMS) in three popular EV vehicles, 2020 Chevrolet Bolt, 2019 Nissan Leaf Plus, and 2020 Tesla Model 3, evaluating their distinct TMS configurations and performance under varied weather conditions. Using both numerical simulations and experimental data collected on a controlled test bench at Argonne National Laboratory, we assess how TMS architecture and operational modes influence energy consumption and range. A comprehensive TMS model was developed, integrating cabin and battery thermal sub-models in the Autonomie software platform, to simulate temperature fluctuations and range impacts. Cabin climate was modeled using a mono-zonal approach, while battery cell temperature distribution was estimated through a 2D nodal structure. Each vehicle's distinct TMS setup was evaluated: the Chevrolet Bolt and Tesla Model 3 use a dual evaporator vapor compression cycle with a PTC heater for the cabin and a coolant loop for battery thermal management; the Nissan Leaf Plus employs a heat pump with a PTC heater for the cabin and air-cooling for the battery. Tests conducted at ambient temperatures of 35°C, 22°C, -7°C, and -18°C reveal significant differences in energy use and range reduction across both configurations and conditions. At 35°C, the Tesla Model 3, Chevrolet Bolt, and Nissan Leaf Plus have a range reduction of 8%, 9%, and 13%, respectively, due to air conditioning. In winter, heating technology is paramount; at -7°C, the Nissan Leaf's heat pump configuration achieves a lower range reduction (19.3%) compared to the Tesla and Chevrolet Bolt PTC heaters, which reduce range by 28.3% and 31%, respectively. Further, this study provides valuable insights for automotive engineers, EV technology researchers, and thermal management system designers aiming to enhance electric vehicle performance by understanding how different weather conditions and TMS architectures impact energy consumption and driving range.

33 ADVANCED PROPULSION SYSTEMS↗

An Alternative to Solution Experiments for Nuclear Data Validation: Reflection and Interaction of Juxtaposed Uranium (RAIJU) Experiment Design

The need for solution experiments was thoroughly discussed at the recent NCERC (National Criticality Experiments Research Center) Futures Meeting in September 2022 for multiple applications including criticality safety, training, and nuclear data. However, this capability does not exist anywhere in the United States. NCERC, located at the Nevada National Security Site and operated by LANL (Los Alamos National Laboratory) is the only general-purpose critical experiments laboratory in the United States. However, solution experiments are not authorized at NCERC, and obtaining that authorization would be too time consuming and costly to happen in the foreseeable future. An alternative is needed – an experimental configuration with the homogeneity of liquid experiments, but without being a liquid. This project, Reflection and Interaction of Juxtaposed Uranium (RAIJU) will fill the gap in capability within LANL, the U.S. Department of Energy, and the international community and will support current and future nuclear material processing needs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative Study of Commercial-Scale CO2 Storage Options in Single and Stacked Saline Formations in Managing Reservoir Pressure Buildup

Presentation at American Association of Petroleum Geologists (AAPG) Carbon, Capture, Utilization, and Storage (CCUS) held in Houston, Texas, April 25–27, 2023. The presentation emphasizes the importance of coordination among CO2 storage projects as CCUS deployment needs to be scaled up. The presentation focuses on findings from reservoir simulation studies in which different configurations of injection zones (a single saline formation and a stacked sequence of saline formations) are targeted for CO2 storage to accommodate the amplified storage volume needed while managing reservoir pressure buildup and interference induced by multi-well injection operations.

Wijaya, Nur↗

Thermal dissipation studies and Pu238/Li source simulation (MCNP) of the K2 containers (COWS)

The six K2 containers (COWS) have been proposed to be shipped to WIPP in the configuration depicted in Figure 1. Currently, the containers reside in the water bath storage and have not been opened since LANL received them. The K2 containers containing the mound scrap material each have their own unique dose rate and thermal loading. 3 The properties of each container are listed below in Table 1. The problem with loading the K2 container into the proposed configuration is the thermal load the package will experience. Each component within the package has a thermal working limit that should not be exceeded. 2 However, the package must also maintain enough shielding to lower the measured dose rate at the surface of the drum to be accepted by WIPP. Testing the current configuration through simulation LANL can prove heat will not compromise any components and dose can be reduced to a safe configuration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗