Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Modeling and optimization of steady flow of natural gas and hydrogen mixtures in pipeline networks

Here, we extend the canonical problems of simulation and optimization of steady-state gas flows in pipeline networks with compressors to the transport of mixtures of highly heterogeneous gases injected throughout a network. Our study is motivated by proposed projects to blend hydrogen generated using clean energy into existing natural gas pipeline systems as part of efforts to reduce the reliance of energy systems on fossil fuels. Flow in a pipe is related to endpoint pressures by a basic Weymouth equation model, with an ideal gas equation of state, where the wave speed depends on the hydrogen concentration. At vertices, in addition to mass balance, we also consider mixing of incoming flows of varying hydrogen concentrations. The problems of interest are the heterogeneous gas flow simulation (HGFS), which determines system pressures and flows given fixed boundary conditions and compressor settings, as well as the heterogeneous gas flow optimization (HGFO), which extremizes an objective by determining optimal boundary conditions and compressor settings. We examine conditions for uniqueness of solutions to the HGFS, as well as compare and contrast mixed-integer and continuous nonlinear programming formulations for the HGFO. We develop computational methods to solve both problems, and examine their performance using four test networks of increasing complexity.

08 HYDROGEN↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and Machine Learning-Guided Materials Design for High-Pressure Hydrogen Compression

Cost-effective and reliable hydrogen compression remains a challenging barrier in the widespread adoption of hydrogen as an energy carrier. The prevailing technology of mechanical compression suffers from several drawbacks, some of which can be addressed by nonmechanical compression strategies (e.g., electrochemical or metal hydride-based thermal compression). Thermally driven metal hydride compression strategies typically rely on multistage metal hydride-based compressors; however, discovering or optimizing low-stability metal hydrides that can pressurize hydrogen upward of 1000 bar is difficult, both with respect to computational predictions and experimental validation. Here, in this study, we (1) demonstrate that simple machine learning-derived design rules can inform the rational design of alloying strategies yielding low-stability hydrides, (2) validate their experimental pressure–composition–temperature (PCT) isotherms up to 875 bar, and (3) utilize a dynamic system-level model of a metal hydride compressor design to evaluate their performance under realistic operating conditions. Importantly, this analysis yields predicted operational efficiencies of both 2-stage (90–875 bar) and 3-stage (20–875 bar) metal hydride compressors to enable further evaluation of this technology and its techno-economic outlook.

alloy optimization↗

Proton Driver Linac for the Frankfurt Neutron Source

The Frankfurt Neutron Source at the Stern-Gerlach-Zentrum (FRANZ) will deliver high neutron fluxes in the energy range of 1 to 500 keV. The Activation Mode provides a high averaged neutron flux created by a cw proton beam of up to 5 mA, while in the Compressor Mode intense neutron pulses of 1 ns length are formed with a repetition rate of up to 250 kHz. The Compressor Mode is well-suited for energy-dependent neutron capture measurements using the Time-of-Flight method in combination with a 4{pi} BaF{sub 2} detector array. The design of the proton driver linac for both operation modes is presented. This includes the volume type ion source, the ExB chopper located in the low energy section, the RFQ-IH combination for beam acceleration and the bunch compressor. Finally, the neutron production at the lithium-7 target and the resulting energy spectrum is described.

43 PARTICLE ACCELERATORS↗

Commissioning of helium refrigeration system at JLab for 12 GeV upgrade

The new 4.5 K refrigerator system added to the Jefferson Lab (JLab) Central Helium Liquefier (CHL) for the 12 GeV upgrade will double its previous capacity. It includes a 4.5 K cold box system and compressor system with associated oil removal and gas management systems. At its maximum capacity condition, this new system supports an additional 238 g/s 30 K 1.16 bar cold compressor return flow, a 15 g/s 4.5 K liquefaction load and a 12.6 kW 35–55 K shield load. Five more design conditions, ranging from liquefaction to refrigeration and a stand-by/reduced load state, were specified for the sizing and selection of its components. The cold box system is comprised of a 300–60 K vertical cold box that incorporates a liquid nitrogen pre-cooler and a 60–4.5 K horizontal cold box housing seven turbines that are configured in four expansion stages including one Joule-Thompson expander. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will briefly review the salient 4.5 K system design features and discuss the recent commissioning results.

42 ENGINEERING↗

Tapered erbium-doped fibre laser system delivering 10 MW of peak power

We consider a fibre laser system generating ∼10-μJ, ∼500-fs pulses with a peak power of ∼10 MW at a repetition rate of 100 kHz and emission wavelength of 1.56 μm. The system is based on a master oscillator – power amplifier configuration. The amplifier ensures chirped-pulse amplification. The pulses are then compressed by a dispersive grating compressor. The output amplifier stage is based on a specially designed tapered large mode area erbium-doped fibre for suppressing nonlinear effects. The experimental data agree with numerical simulation results for the stretcher, amplifier and compressor. The stretcher and amplifier have been simulated using a generalised nonlinear Schrödinger equation. In addition, numerical simulation results suggest that optimising the stretcher and compressor will potentially allow the peak power of the system to be scaled up to ∼30 MW. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commissioning and operational results of helium refrigeration system at JLab for the 12GeV upgrade

The new 4.5 K refrigerator system at the Jefferson Lab (JLab) Central Helium Liquefier (CHL-2) for the 12 GeV upgrade was commissioned in late spring of 2013, following the commissioning of the new compressor system, and has been supporting 12 GeV LINAC commissioning since that time. Six design modes were tested during commissioning, consisting of a maximum capacity, nominal capacity, maximum liquefaction, maximum refrigeration, maximum fill and a stand-by/reduced load condition. The maximum capacity was designed to support a 238 g/s, 30 K and 1.16 bar cold compressor return flow, a 15 g/s, 4.5 K liquefaction load and a 12.6 kW, 35-55 K shield load. The other modes were selected to ensure proper component sizing and selection to allow the cold box to operate over a wide range of conditions and capacities. The cold box system is comprised of two physically independent cold boxes with interconnecting transfer-lines. The outside (upper) 300-60 K vertical cold box has no turbines and incorporates a liquid nitrogen pre-cooler and 80-K beds. The inside (lower) 60-4.5 K horizontal cold box houses seven turbines that are configured in four expansion stages including one Joule-Thompson expander and a 20-K bed. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will summarize the analysis of the test data obtained over the wide range of operating conditions and capacities which were tested.

Knudsen, Peter N.↗

cuZ-Checker: A GPU-Based Ultra-Fast Assessment System for Lossy Compressions

Lossy compression is becoming an indispensable technique for the success of today's extreme-scale high-performance computing projects that produce vast volumes of data during scientific simulations or instrument data acquisitions. Comprehensively understanding the compression quality and performance of different lossy compressors is critical to selecting the best-fit compressors and using them properly and efficiently in practice. A few lossy compression assessment tools (e.g., Z-checker) have been developed, but none of them support the execution in a GPU environment. This is a significant gap because many recent extreme-scale applications and lossy compressors (e.g., cuSZ) can run entirely within GPUs. In this work, we develop an efficient lossy compression measuring system (called cuZ-Checker) on the GPU platform, which aims to perform the lossy compression quality and performance assessment completely within the GPU environment. Our contribution is threefold. (1) We develop a novel GPU-based lossy compression measuring framework using a computation pattern-based design approach. This approach classifies the computing-intensive metrics into three categories based on their patterns which creates large opportunities for kernel fusion and data reuse. (2) For each pattern in cuZ-Checker, we develop a CUDA kernel and provide fine-grained optimizations to boost its performance. (3) We thoroughly evaluate our cuZ-checker on a V100 GPU using four real-world scientific application datasets. Experiments show that cuZ-Checker can significantly accelerate the overall lossy compression assessment performance by 23X similar to 31X compared with the OpenMP-based multithreading CPU performance. To the best of our knowledge, this is the first lossy compression measuring system designed for GPU devices.

GPU↗

Optimizing Lossy Compression Rate-Distortion from Automatic Online Selection between SZ and ZFP

With ever-increasing volumes of scientific data produced by high-performance computing applications, significantly reducing data size is critical because of limited capacity of storage space and potential bottlenecks on I/O or networks in writing/reading or transferring data. SZ and ZFP are two leading BSD licensed open source C/C++ libraries for compressed floating-point arrays that support high throughput read and write random access. However, their performance is not consistent across different data sets and across different fields of some data sets, which raises the need for an automatic online (during compression) selection between SZ and ZFP, with minimal overhead. In this paper, the automatic selection optimizes the rate-distortion, an important statistical quality metric based on the signal-to-noise ratio. To optimize for rate-distortion, we investigate the principles of SZ and ZFP. We then propose an efficient online, low-overhead selection algorithm that predicts the compression quality accurately for two compressors in early processing stages and selects the best-fit compressor for each data field. Here, we implement the selection algorithm into an open-source library, and we evaluate the effectiveness of our proposed solution against plain SZ and ZFP in a parallel environment with 1,024 cores. Evaluation results on three data sets representing about 100 fields show that our selection algorithm improves the compression ratio up to 70 percent with the same level of data distortion because of very accurate selection (around 99 percent) of the bestfit compressor, with little overhead (less than 7 percent in the experiments).

97 MATHEMATICS AND COMPUTING↗

Optimizing Error-Bounded Lossy Compression for Scientific Data With Diverse Constraints

Vast volumes of data are produced by today's scientific simulations and advanced instruments. These data cannot be stored and transferred efficiently because of limited I/O bandwidth, network speed, and storage capacity. Error-bounded lossy compression can be an effective method for addressing these issues: not only can it significantly reduce data size, but it can also control the data distortion based on user-defined error bounds. In practice, many scientific applications have specific requirements or constraints for lossy compression, in order to guarantee that the reconstructed data are valid for post hoc analysis. For example, some datasets contain irrelevant data that should be isolated in particular and users often have intuition regarding value ranges, geospatial regions, and other data subsets that are crucial for subsequent analysis. Existing state-of-the-art error-bounded lossy compressors, however, do not consider these constraints during compression, resulting in inferior compression ratios with respect to user's post hoc analysis, due to the fact that the data itself provides little or no value for post hoc analysis. In this work we address this issue by proposing an optimized framework that can preserve diverse constraints during the error-bounded lossy compression, e.g., cleaning the irrelevant data, efficiently preserving different precision for multiple value intervals, and allowing users to set diverse precision over both regular and irregular regions. We perform our evaluation on a supercomputer with up to 2,100 cores. Experiments with six real-world applications show that our proposed diverse constraints based error-bounded lossy compressor can obtain a higher visual quality or data fidelity on reconstructed data with the same or even higher compression ratios compared with the traditional state-of-the-art compressor SZ. Furthermore, our experiments also demonstrate very good scalability in compression performance compared with the I/O throughput of the parallel file system.

97 MATHEMATICS AND COMPUTING↗

Numerical Study of Liquid Piston Compression Using Large-Eddy Simulation and Volume-of-Fluid Approach

Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.

Nguyen, Thien D.↗

Ultrafast Error-bounded Lossy Compression for Scientific Datasets

Today's scientific high-performance computing applications and advanced instruments are producing vast volumes of data across a wide range of domains, which impose a serious burden on data transfer and storage. Error-bounded lossy compression has been developed and widely used in the scientific community because it not only can significantly reduce the data volumes but also can strictly control the data distortion based on the user-specified error bound. Existing lossy compressors, however, cannot offer ultrafast compression speed, which is highly demanded by numerous applications or use cases (such as in-memory compression and online instrument data compression). In this paper, we propose a novel ultrafast error-bounded lossy compressor that can obtain fairly high compression performance on both CPUs and GPUs and with reasonably high compression ratios. The key contributions are threefold. (1) We propose a generic error-bounded lossy compression framework---called SZx---that achieves ultrafast performance through its novel design comprising only lightweight operations such as bitwise and addition/subtraction operations, while still keeping a high compression ratio. (2) We implement SZx on both CPUs and GPUs and optimize the performance according to their architectures. (3) We perform a comprehensive evaluation with six real-world production-level scientific datasets on both CPUs and GPUs. Experiments show that SZx is 2~16x faster than the second-fastest existing error-bounded lossy compressor (either SZ or ZFP) on CPUs and GPUs, with respect to both compression and decompression.

Yu, Xiaodong↗

CEAZ: Accelerating Parallel I/O Via Hardware-Algorithm Co-Designed Adaptive Lossy Compression

As supercomputers continue to grow to exa-scale, the amount of data that needs to be saved or transmitted is exploding. To this end, many previous works have studied using error-bounded lossy compressors to reduce the data size and improve the I/O performance. However, little work has been done for effectively offloading lossy compression onto FPGA-based SmartNICs to reduce the compression overhead. In this paper, we propose a hardware-algorithm co-design of efficient and adaptive lossy compressor for scientific data on FPGAs (called CEAZ) to accelerate parallel I/O. Our contribution is fourfold: (1) We propose an efficient Huffman coding approach that can adaptively update Huffman codewords online based on codewords generated offline (from a variety of representative scientific datasets). (2) We derive a theoretical analysis to support a precise control of compression ratio under an error-bounded compression mode, enabling accurate offline Huffman codewords generation. This also help us create a fixed-ratio compression mode for consistent throughput. (3) We develop an efficient compression pipeline by adopting cuSZ’s dual-quantization algorithm to our hardware use case. (4) We evaluate CEAC on five real-world datasets with both a single FPGA board and 256 nodes from Bridges2 supercomputer. Experiments show that CEAZ outperforms the second-best FPGA-based lossy compressor by 2× of throughput and 9.6× of compression ratio. It also improves MPI_File_write and MPI_Gather throughputs by up to 32.7× and 31.4×, respectively.

Zhang, Chengming↗

Active cooling of pulse compression diffraction gratings for high energy, high average power ultrafast lasers

Laser energy absorption and subsequent heat removal from diffraction gratings in chirped pulse compressors poses a significant challenge in high repetition rate, high peak power laser development. In order to understand the average power limitations, we have modeled the time-resolved thermo-mechanical properties of current and advanced diffraction gratings. We have also developed and demonstrated a technique of actively cooling Petawatt scale, gold compressor gratings to operate at 600W of average power - a 15x increase over the highest average power petawatt laser currently in operation. As a result, combining this technique with low absorption multilayer dielectric gratings developed in our group would enable pulse compressors for petawatt peak power lasers operating at average powers well above 40kW.

42 ENGINEERING↗

Energy efficiency of blower heater non-purge compressed air dryers

This research focuses on twin tower regenerative closed loop desiccant dryers, specifically: blower heater non-purge (BHNP) with and without cooling water pumps, compressed-air heater purge (CHP), blower heater purge (BHP) and pressure swing heaterless (PSH). The research was conducted by collecting and analysing real time current draw data on air compressors and associated dryers at eight different facilities (13 air compressors) in terms of energy, power and cost. A decision tool was developed to depict the operational characteristics (power, energy and cost) of each type of dryer if used in conjunction with the selected compressor system. Finally, this research, on an equivalent normalised basis, compared and contrasted the different types of dryers in terms of performance and cost. Here, the research concluded that of the five types of desiccant dryer types observed the most energy efficient was the BHNP (with cooling water pump), subject to the operational conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of A High Performance Cold Climate Heat Pump

The primary goals of the proposed project were to develop, test, and evaluate a high performance and cost-effective vapor compression air-source heat pump for use in cold climate regions. Vapor compression heat pumps are a proven technology, and have been used for many years to meet heating requirements for buildings in residential, commercial, and industrial applications. However, in climate regions that experience very low outdoor ambient temperatures both the heating capacity and coefficient of performance (COP) of traditional air-source vapor compression heat pumps drops dramatically with a decrease in the outdoor air temperature. The efficiency of heat pumping equipment has improved substantially over the past 20 years; however, the efficiencies of the highest rated equipment on the market are approaching practical limits that cannot be surpassed without modifications to the basic cycle and possibly the use of additional hardware. In this report, three technologies to improve the efficiency of vapor compression systems are described. These are a) vapor injected compression, b) oil flooded compression and c) hybrid flow control of the evaporator. Compressor prototypes for both, oil flooded and vapor injected compression were developed by Emerson Climate Technologies. For the oil flooded compressor, the oil injection port location was optimized and an internal oil separator was added using several design iterations. After initial testing at Emerson Climate Technologies, further testing was done at Purdue University, and compressor models were developed. These models were then integrated into a system model to determine the achievable improvement of seasonal energy efficiency (SEER) for Minneapolis (Minnesota) climate. For the oil flooded compression, a 34% improvement in seasonal energy efficiency was found while a 21% improvement in seasonal energy efficiency ratio was found for the vapor injected compression. It was found that one benefit of both tested compression technologies is a lower discharge temperature, which allows for continued operation at lower ambient temperatures. A bin analysis of the vapor injected prototype cold climate heat pump predicts a 6% improvement in HSPF for Minneapolis. This improvement is mainly a result of the increased capacity of the system for active vapor injection. For the oil flooded system, a slightly larger performance improvement is predicted, in this case mostly caused by an increase in heating COP. Based on an economic analysis of these results, the maximum additional cost of the system changes, for the Minneapolis location, are $\$430$ for the vapor injected system and $\$391$ for the oil flooded system. These estimates assume that a 3-year simple payback period is accepted by the customer. For the hybrid flow control of evaporators, a new type of balancing valve was developed together with Emerson Climate technologies to reduce the cost of the control scheme. In contrast to conventional stepper motor valves, this valve requires less cables and can be driven by a cheaper output circuit on the control board. The correct valve size was determined in a dedicated test stand in several design iterations. The performance benefits of the hybrid control of the evaporator coil were determined for clean coil conditions as well as with partial blockage of the air inlet grille and under frosting conditions. For clean coil conditions, the benefits in terms of COP and capacity are negligible. However, significant benefits were noted for severely air-maldistributed operating conditions. For the H2-test, the maximum COP improvement of 17% along with a capacity improvement of nearly 40% was observed. Overall, the hybrid control scheme leads to a significant amount of performance improvement, if the air inlet conditions to the evaporator are maldistributed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2012 Update to the Site Discharge Pollution Prevention Plan, Rev. 1: Sandia/Mortandad Watershed Receiving Waters: Sandia Canyon, Cañada del Buey, Mortandad Canyon, and Ten-Site Canyon (Vol. 2)

Two historical industrial activity areas are associated with S001, S-SMA-0.25: Sites 03-013(a) and 03-052(f). Solid Waste Management Unit (SWMU) 03-013(a) is a 1500-ft-long corrugated metal pipe (CMP) storm drain that served building 03-0038. The storm drain ran underground around building 03-0038, east along the south side of the Otowi Building (building 03-0261) and connected to four other storm drains before daylighting 100 ft east of the Otowi Building where it became an open concrete- and rock-lined ditch. The open drain continued past transportable office buildings (buildings 03-1616 and 03-1617) and passed beneath streets and sidewalks to a point northeast of the Oppenheimer Study Center (building 03-0207) where it discharged to the SWMU 03-052(f) outfall before draining into Sandia Canyon. Most of the CMP associated with SWMU 03-013(a) was removed in 2004 to accommodate the construction of the National Security Science Building (03-1400) and a new parking structure (03-1402) east of the Otowi Building. The CMP was managed as nonhazardous/nonradioactive industrial waste. Inspection of the drainline trench showed no evidence of a release from the drainpipe. A new storm drainline was installed west of SWMU 03-052(f) to manage storm water runoff from the new parking structure. The new storm drain discharges to SWMU 03-052(f). Potential contaminants associated with industrial materials historically managed at this Site are metals and petroleum products. SWMU 03-052(f) is a formerly permitted outfall (U.S. Environmental Protection Agency [EPA] 03A023) that received wastewater from floor drains [Area of Concern (AOC) 03-013(b)], sinks, water fountains, and a storm drain [SWMU 03-013(a)], which served building 03-0038 until 1987 when the drains in building 03-0038 were rerouted to the Technical Area 03 (TA-03) sanitary sewer system. Stoddard solvents, dry acid, and caustic materials from the maintenance shop were discarded through sinks and floor drains to this outfall. Spent paint solvents and cutting oils contaminated with machined beryllium particles may also have been released to the floor drains during the 1960s and 1970s. In addition, cooling water for welding torches was discharged directly to the drains. The first spill was approximately 200 gal. of a water-waste oil mixture that was discharged when an automatic compressor blowdown mechanism failed. A second spill from a ruptured air-compressor oil line resulted in the release of approximately 1 qt of compressor oil to the drain. This spill produced an oily sheen on the surface of the water at the SWMU 03-052(f) outfall. A third spill occurred when approximately 15 gal. of diesel fuel was released from a ruptured truck fuel line into the utilities construction trench between buildings 03-1793 and 03-1794. On the same day, a clay sewer pipe in the utility trench broke, releasing approximately 2000 gal. of wastewater into the excavation. A sump was used to remove the wastewater from the excavation, and the wastewater was discharged to SWMU 03-052(f). The diesel-contaminated asphalt and soil were removed and disposed of. Runoff from parking lots and the surrounding areas also discharges to the outfall. Outfall 03A023 was removed from the National Pollutant Discharge Elimination System (NPDES) permit on July 11, 1997. Potential contaminants associated with industrial materials historically managed at this Site are volatile organic solvents, petroleum products, and metals included in discharges from the maintenance contractor’s shop in building 03-38 and three reported petroleum hydrocarbon spills.

54 ENVIRONMENTAL SCIENCES↗