Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Certified”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Fractal Analysis of Visual Search Activity for Mass Detection During Mammographic Screening

Purpose: The objective of this study was to assess the complexity of human visual search activity during mammographic screening using fractal analysis and to investigate its relationship with case and reader characteristics. Methods: The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) and 10 readers (three board certified radiologists and seven radiology residents), formed the corpus data for this study. The fractal dimension of the readers’ visual scanning patterns was computed with the Minkowski–Bouligand box-counting method and used as a measure of gaze complexity. Individual factor and group-based interaction ANOVA analysis was performed to study the association between fractal dimension, case pathology, breast density, and reader experience level. The consistency of the observed trends depending on gaze data representation was also examined. Results: Case pathology, breast density, reader experience level, and individual reader differences are all independent predictors of the visual scanning pattern complexity when screening for breast cancer. No higher order effects were found to be significant. Conclusions: Fractal characterization of visual search behavior during mammographic screening is dependent on case properties and image reader characteristics.

47 OTHER INSTRUMENTATION↗

Identifying Suitable Front Contacts for High‐Efficiency Cd(Se,Te) Solar Cells on Space‐Qualified Cover Glass

Deployment of photovoltaics in space requires devices that combine high-efficiency, low areal mass, and resilience to harsh environments. Historically, high-efficiency multijunction III–V materials have dominated space power systems; however, their high cost and limited manufacturing throughput motivate the exploration of scalable alternatives. While CdTe-based thin-film photovoltaics offer an attractive option, their performance on non-conventional substrates can suffer from front contact instability under higher-temperature processing. Here, the role of front contact chemistry in limiting cell performance is investigated using CdTe-based devices fabricated on 150 μm thick Ceria-doped space-qualified 0214 Corning glass. A matrix of four transparent conducting oxides (TCOs: CTO, AZO, ITO, IZO) combined with two n-type emitters (MZO, IGO) reveals chemical stability at the front interface—rather than absorber composition alone—governs recombination losses, voltage deficits, and device reproducibility. Chemically stable front contact combinations suppress elemental diffusion and interfacial degradation, resulting in significantly improved carrier lifetimes and junction quality. These insights are validated through record-certified Cd(Se,Te) cell efficiencies of 18.4% under AM1.5G and 16.2% under AM0 illumination on ultra-thin glass. Beyond CdTe, this work provides a general framework for the rational selection of TCO/emitter interfaces in superstrate thin-film photovoltaics, including emerging technologies like metal halide perovskites, while enabling high-efficiency, lightweight photovoltaics for space applications.

14 SOLAR ENERGY↗

Characterization of Particle Size Standard NIST 1019b with SynchrotronX-ray Microtomography and Digital Data Extraction

We show that synchrotron x-ray microtomography ({mu}CT) followed by digital data extraction can be used to examine the size distribution and particle morphologies of the polydisperse (750 to 2450 {micro}m diameter) particle size standard NIST 1019b. Our size distribution results are within errors of certified values with data collected at 19.5 {micro}m/voxel. One of the advantages of using {mu}CT to investigate the particles examined here is that the morphology of the glass beads can be directly examined. We use the shape metrics aspect ratio and sphericity to examine of individual standard beads morphologies as a function of spherical equivalent diameters. We find that the majority of standard beads possess near-spherical aspect ratios and sphericities, but deviations are present at the lower end of the size range. The majority (> 98%) of particles also possess an equant form when examined using a common measure of equidimensionality. Although the NIST 1019b standard consists of loose particles, we point out that an advantage of {mu}CT is that coherent materials comprised of particles can be examined without disaggregation.

36 MATERIALS SCIENCE↗

Development of Parameters for the Particle Size Distribution of TATB

Laser light scattering (LLS), manual counting of scanning electron microscopy (SEM) images, and reduction of SEM images using ImageJ (open source program) to determine Feret (caliper) diameters were applied to determine particle size distribution (PSD) of four preparations of 1,3,5‐triamino‐2,4,6‐trinitrobenzene (TATB) and yttria‐stabilized zirconia (YSZ), an SEM certified standard. Mie theory was used to reduce the LLS data. The spherical nature of the YSZ made it a good candidate for LLS. Variations in n , the refractive index, and iκ, the imaginary component, produced very little change in the PSD. However, changing the carrier liquid from H 2 O to a 40% aqueous sucrose solution, thereby changing the carrier refractive index, n 0 , substantially affected the PSD. The Mie complex refractive indices for the YSZ were n = 2.200, iκ = 0.100, with a 40% aqueous sucrose solution, n 0 = 1.400. The triclinic crystal structure of TATB made refractive index determinations more difficult, so a study was conducted varying Mie parameters and comparing them to the same data reduced using the Fraunhofer theory. Changing the n and κ parameters produced PSD with a small concentration of particles less than 1 µm in size or none in this range. SEM images, Feret data, manual counting, and Fraunhofer data reduction indicate particles less than 1 µm are probably < 5% in concentration. The final selection of Mie parameters for TATB was n = 2.283, iκ = 0.1, and suspension medium, n 0 = 1.330. Finally, computations, using density functional theory produced similar parameters.

Feret diameter↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid Quantitation of Ascorbic and Folic Acids in SRM 3280 Multivitamin/Multielement Tablets using Flow-Injection Tandem Mass Spectrometry

RATIONALE: Ascorbic acid (AA) and folic acid (FA) are water-soluble vitamins and are usually fortified in food and dietary supplements. For the safety of human health, proper intake of these vitamins is recommended. Improvement in the analysis time required for the quantitative determination of these vitamins in food and nutritional formulations is desired. METHODS: A simple and fast (~5 min) in-tube sample preparation was performed, independently for FA and AA, by mixing extraction solvent with a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Quantitative detection was achieved by flow-injection (1 L injection volume) electrospray ionization tandem mass spectrometry (ESI-MS/MS) in negative ion mode using the method of standard addition. RESULTS: Method of standard addition was employed for the quantitative estimation of each vitamin in a sample extract. At least 2 spiked and 1 non-spiked sample extract were injected in triplicate for each quantitative analysis. Given an injection-to-injection interval of approximately 2 min, about 18 min was required to complete the quantitative estimation of each vitamin. The concentration values obtained for the respective vitamins in the standard reference material (SRM) 3280 using this approach were within the statistical range of the certified values provided in the NIST Certificate of Analysis. The estimated limit of detections of FA and AA were 13 and 5.9 ng/g, respectively. CONCLUSIONS: Flow-injection ESI-MS/MS was successfully applied for the rapid quantitation of FA and AA in SRM 3280 multivitamin/multielement tablets.

ascorbic acid↗

Photovoltaic Devices Based on Colloidal PbX Quantum Dots: Progress and Prospects

Here, a certified power conversion efficiency (PCE) of 12.0% and an outstanding air stability has been achieved for PbX quantum dots (QDs) solar cells, indicating strong potential for next generation low-cost solution-processed photovoltaics. Similar progress has been made in several other solar cell architectures employing PbX QD absorbers. This article aims to review the recent progress in understanding the photovoltaic-relevant properties of PbX QDs and highlight their application in various types of photovoltaic devices. In doing so, we hope that the unique properties of PbX QDs can be better understood in a broader context, and their potential can be fully realized with the aiding of other photovoltaic materials and novel device structures.

14 SOLAR ENERGY↗

Geometry and Gesture-Based Features from Saccadic Eye-Movement as a Biometric in Radiology

In this study, we present a novel application of sketch gesture recognition on eye-movement for biometric identification and estimating task expertise.The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) and 10 readers (three board certified radiologists and seven radiology residents), formed the corpus for this study.Sketch gesture recognition techniques were employed to extract geometric and gesture-based features from saccadic eye-movements.Our results show that saccadic eye-movement, characterized using sketch-based features, result in more accurate models for predicting individual identity and level of expertise than more traditional eye-tracking features.

Alamudun, Folami↗

Accurate and Sensitive Analytical Strategy for the Determination of Antimony: Hydrogen Assisted T-Shaped Slotted Quartz Tube-Atom Trap-Flame Atomic Absorption Spectrometry

Antimony is known to have some adverse health effects on human health. Flame atomic absorption spectrometry (FAAS) is a widely used instrumental for the determination of antimony and other metals. However, it lacks the sensitivity to determine these metals at trace levels. This study was aimed at overcoming this setback by using hydrogen assisted T-shaped slotted quartz tube technique to preconcentrate and determine antimony by FAAS. All the system parameters were optimized to enhance the detection power of the system. Under the optimum experimental conditions, the limits of detection and quantification were found to be 0.75 and 2.49 µg L{sup −1}, respectively with R{sup 2} value of 0.9999. Accuracy of the developed method was validated by experimental results agreeing to the certified value of a standard reference material. Recovery studies were also carried out to determine the method’s applicability to tap and mineral water samples, and the results obtained were appreciable.

54 ENVIRONMENTAL SCIENCES↗

Abdominal manifestations of hereditary hemorrhagic telangiectasia: a series of 333 patients over 15 years

Purpose: Hereditary hemorrhagic telangiectasia (HHT) is an autosomal dominant multi-organ vascular disorder that commonly affects the gastrointestinal tract and the liver resulting in telangiectasias and arteriovenous malformations (AVMs). Previous studies looking at the prevalence of liver and abdominal organ involvement in HHT have been limited by differing imaging techniques and sample size limitations. We sought to define the prevalence of HHT related abdominal vascular abnormalities using optimized multiphasic contrast-enhanced abdominal computed tomography (CT) exams in a large cohort of HHT patients. Methods: Between January 2001 and May 2015; we identified a total of 333 consecutive HHT patients who had undergone a dedicated HHT protocol multiphase abdominal CT at our institution. The CT exams were reviewed by three board certified abdominal radiologists for the presence of vascular abnormalities involving the liver, pancreas, spleen, and other abdominal organs. Vascular abnormalities involving the liver were further categorized as telangiectasias, large confluent vascular masses, perfusion abnormalities, or hepatic shunts. Results: In patients with abdominal vascular abnormalities, the liver was the most commonly involved organ, with 180 out of 333 (54.1%) patients demonstrating at least one hepatic vascular abnormality (telangiectasia, confluent vascular mass, transient perfusion abnormalities, and hepatic shunts), with most (70.0%) demonstrating multiple hepatic vascular abnormalities. The other most common organs involved included the pancreas (18.0%), spleen (6.3%), and small bowel (4.5%). Conclusion: In patients with the clinical diagnosis of HHT, greater than half demonstrate an abdominal vascular abnormality, with the most commonly involved organ being the liver. These may be under recognized on routine or single phase contrast-enhanced CT of the abdomen. This supports the use of optimized multiphasic abdominal CT exams as an important tool for the evaluation and screening of patients with HHT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal lexicon of gadoxetic acid-enhanced magnetic resonance imaging for the diagnosis of hepatocellular carcinoma modified from LI-RADS

Purpose: To define the optimal lexicon of major imaging findings on gadoxetic acid-enhanced MRIs to diagnose HCC to improve diagnostic performance of the LI-RADS. Methods: Two hundred forty-one hepatic lesions (149 HCC, six other malignancies, 86 benign lesions) in 177 treatment-naïve patients at risk of HCC who underwent gadoxetic acid-MRIs from January 2013 to December 2015 were retrospectively reviewed using either histopathological or follow-up imaging findings as a standard reference. Two board-certified radiologists independently evaluated the imaging features and categorized the nodules based on the original and the following modified definitions in LI-RADS: (1) washout appearance in the portal venous phase (PVP) only versus that in the PVP or transitional phase, and (2) enhancing capsule only versus enhancing or non-enhancing capsule. Diagnostic performance and inter-observer agreement of LR-5 were assessed and compared between the algorithms using generalized estimation equation. Results: The sensitivity [79.2% (95% confidence interval 71.9, 85.0)] and accuracy [84.6% (79.5, 88.7)] of LR-5 were significantly higher for modified lexicon compared with original LI-RADS [60.4% (52.3, 67.9) and 73.9% (67.9, 79.0); P < 0.001 in all cases]. There was no significant difference in specificity [93.5% (86.2, 97.0) and 95.7% (89.0, 98.4); P = 0.153]. Subgroups of lesions < or ≥ 2 cm showed similar tendencies. Inter-observer agreement for capsule appearance was fair to moderate, whereas that for other imaging findings was good to excellent. Conclusions: Compared to original LI-RADS, LI-RADS with modified lexicon showed higher sensitivity for the diagnosis of HCC using gadoxetic acid-MRI, with similar specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Adrenal Venous Sampling by Non-experts with Reference to CT Images

PurposeTo establish technical success rates and safety of adrenal venous sampling (AVS) performed by non-experts with reference to CT images.Materials and Methods104 AVS procedures with adrenocorticotropic hormone stimulation were performed for patients with suspected primary aldosteronism. One of three radiology residents with 2nd, 5th, and 5th grade experience undertook the procedure under the guidance of an experienced, board-certified interventional radiologist with reference to contrast-enhanced CT images obtained in 102 cases. Successful catheterization of the adrenal veins was assessed using three criteria: an adrenal venous cortisol concentration of more than 200 μg/dL (criterion A); an adrenal vein/inferior vena cava cortisol ratio of more than 5:1 (criterion B); and an adrenal vein/inferior vena cava cortisol ratio of more than 10:1 (criterion C).ResultsThe operators were aware of the anatomy of the left adrenal veins in 102 cases (98 %) and of the right adrenal veins in 99 cases (95 %) prior to the procedure. CT identified the correct position of the right adrenal vein orifice in 82 of 99 cases (83 %). The overall technical success rates for AVS from the right adrenal vein according to criteria A, B, and C, were 96, 96, and 94 %, respectively. Those for the left adrenal vein were 97, 98, and 94 %, respectively. No significant differences in success rates were observed between the operators (p = 0.922–0.984). No major complications, including adrenal vein rupture, were observed.ConclusionsWhen CT images are used to guide AVS, the procedure can be performed successfully and safely even by non-experts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

McCormick envelopes in mixed-integer PDE-constrained optimization

McCormick envelopes are a standard tool for deriving convex relaxations of optimization problems that involve polynomial terms. Such McCormick relaxations provide lower bounds, for example, in branch-and-bound procedures for mixed-integer nonlinear programs but have not gained much attention in PDE-constrained optimization so far. This lack of attention may be due to the distributed nature of such problems, which on the one hand leads to infinitely many linear constraints (generally state constraints that may be difficult to handle) in addition to the state equation for a pointwise formulation of the McCormick envelopes and renders bound-tightening procedures that successively improve the resulting convex relaxations computationally intractable. We analyze McCormick envelopes for a model problem class that is governed by a semilinear PDE involving a bilinearity and integrality constraints. We approximate the nonlinearity and in turn the McCormick envelopes by averaging the involved terms over the cells of a partition of the computational domain on which the PDE is defined. This yields convex relaxations that underestimate the original problem up to an a priori error estimate that depends on the mesh size of the discretization. These approximate McCormick relaxations can be improved by means of an optimization-based bound-tightening procedure. We show that their minimizers converge to minimizers to a limit problem with a pointwise formulation of the McCormick envelopes when driving the mesh size to zero. We provide a computational example, for which we certify all of our imposed assumptions. The results point to both the potential of the methodology and the gaps in the research that need to be closed. Our methodology provides a framework first for obtaining pointwise underestimators for nonconvexities and second for approximating them with finitely many linear inequalities in an infinite-dimensional setting.

Approximations and Expansions↗

Neutron Gamma-Method for Monitoring Ash Content of Coal

A brief analysis is given of the modern instrumental methods of monitoring the ash content of coal. Their particulars and drawbacks are examined. A neutron gamma-method of monitoring the ash content is proposed on the basis of integrated use of prompt γ-radiation accompanying inelastic scattering of fast neutrons and radiative capture of thermal neutrons by nuclei of the primary elements comprising the organic and mineral components of coal. The instrumental-methodological parameters of monitoring (sizes of the analyzed samples, energy intervals of the detected gamma radiation) making it possible to the increase the sensitivity of the method with respect to the ash content and to minimize the impact of the variability of the moisture content of coal on its material composition, are optimized. The method has been certified and recommended for representative monitoring of the quality of coarse coal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Parameters Assigned to an Anti-Surge Controller in a Turbocompressor Automation System

An algorithm that describes the operation of a dynamic compressor control system with anti-surge valve is presented. A technique for the use of the certified gaseodynamic characteristics of a compressor and the equations of state of actual gases for determining the parameters assigned to an anti-surge controller is presented. Through the use of the algorithm and the computation technique in the design of an anti-surge compressor control system, the occurrence of surge and the stagnation regimes in the gas flow may be prevented.

42 ENGINEERING↗

Theoretical Study of Doped and Co-doped Gallium Nitride with (Cr, Ni): an LDA-SIC and Monte Carlo Study

Using a composition of first-principle density functional theory (DFT) calculations and Monte Carlo simulation with the calculation within the self-interaction-correction local-density approximation, the electronic, magnetic, and optical properties of doped and co-doped GaN (Ga{sub 1−x}Cr{sub x}N, Ga{sub 1−x}Ni{sub x}N) and GaN (Ga{sub 1−2x}Cr{sub x}Ni{sub x}N) (x = 0.03 and 0.06), respectively, have been investigated. Our results have proven that the half-metallic ferromagnetic state still persists of co-doped GaN. In comparing the total energies, ab initio calculations certify the magnetic-state stability of the ferromagnetic phase compared with the spin-glass state. The exchange interactions obtained from the ab initio calculations were used as input parameters in a classical Ising model by Monte Carlo simulation to confirm the half-metallic ferromagnetic states with high Neel temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Round-robin 230 Th– 234 U age dating of bulk uranium for nuclear forensics

In an inter-laboratory measurement comparison study, four laboratories determined 230 Th– 234 U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. As a result, these model ages are concordant with to slightly older than the known production age of NBL U050.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LA-ICP/MS Analysis of Plastics as a Method to Support Polymer Assay in the Assessment of Materials for Low Background Detectors

Ultra low-background radiation measurements are essential to several large-scale physics investigations, such as those involving neutrinoless double-beta decay, dark matter detection (such as SuperCDMS), and solar neutrino detection. There is a need for electrically and thermally insulating dielectric materials with extremely low-background radioactivity for detector construction. This need is best met with plastics. Most currently available structural plastics have milliBecquerel-per-kilogram total intrinsic radioactivity. Modern low-level detection systems require a large variety of plastics with low microBecquerel-per-kilogram levels. However, the assay of polymer materials for extremely low levels of radioactive elements, uranium and thorium in particular, presents new challenges. It is only recently that any certified reference materials (CRMs) for toxic metals such as lead or cadmium in plastics have become available. However, there are no CRMs for uranium or thorium in thermoplastics. This paper discusses our assessment of the use of laser ablation (LA) for sampling and inductively coupled plasma mass spectrometry (ICP-MS) for analysis of polyethylene (PE) samples, with an emphasis on uranium determination. Using a CRM for lead in PE, we examine LA and ICP-MS parameters that determine whether the total atom efficiencies for uranium and lead are similar, and explore methods to use the lead content in a plastic as part of the process of estimating or determining the uranium content by LA-ICP-MS.

laser ablation↗