At least 415 records · Page 23

A curve-fitting technique for the determination of gain and saturation intensity in homogeneously-broadened gas lasers: Application to a waveguide CO2 laser

A least squares curve-fitting algorithm is derived which allows the simultaneous estimation of the small signal gain and the saturation intensity from an arbitrary number of data points relating power output to the incidence angle of an internal coupling plate. The method is used to study the dependence of the two parameters on tube pressure and discharge current in a waveguide CO2 laser having a 2 mm diameter capillary. It is found that, at pressures greater than 28 torr, rising CO2 temperature degrades the small signal gain at current levels as low as three milliamperes.

Degnan, J. J.↗

Improving the Sensitivity of Mass Spectrometry by Using a New Sheath Flow Electrospray Emitter Array at Subambient Pressures

Arrays of chemically etched emitters with individualized sheath gas capillaries have been developed to enhance electrospray ionization (ESI) at subambient pressures. By including an emitter array in a subambient pressure ionization with nanoelectrospray (SPIN) source, ionization and transmission efficiency can be maximized allowing for increased sensitivity in mass spectrometric analyses. The SPIN source eliminates the major ion losses at conventional ESI-mass spectrometry (MS) interface by placing the emitter in the first vacuum region of the instrument. To facilitate stable electrospray currents in such conditions we have developed an improved emitter array with individualized sheath gas around each emitter. The utility of the new emitter arrays for generating stable multi-electrosprays at subambient pressures was probed by coupling the emitter array/SPIN source with a time of flight (TOF) mass spectrometer. The instrument sensitivity was compared between single emitter/SPIN-MS and multi-emitter/SPIN-MS configurations using an equimolar solution of 9 peptides. An increase in sensitivity correlative to the number of emitters in the array was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of intense Stokes and anti-Stokes lines in CH4 pumped by 355 nm of a Nd:YAG laser

The stimulated Raman scattering (SRS) and four-wave mixing (FWM) processes are studied in detail in CH4 gas pumped by the third-harmonic of Nd:YAG laser at 355 nm. The conversion efficiency and average output energy are measured for the various Stokes and anti-Stokes lines at different experimental conditions. The threshold input energy at various CH4 pressures is calculated for the unguided and capillary waveguide Raman cells. The calculated values for the capillary case are compared with the measured values at different CH4 pressures and the two results are in good agreement.

Sentrayan, K.↗

Critical energy barrier for capillary condensation in mesopores: Hysteresis and reversibility

Capillary condensation in the regime of developing hysteresis occurs at a vapor pressure, P{sub cond}, that is less than that of the vapor-like spinodal. This is because the energy barrier for the vapor-liquid transition from a metastable state at P{sub cond} becomes equal to the energy fluctuation of the system; however, a detailed mechanism of the spontaneous transition has not been acquired even through extensive experimental and simulation studies. We therefore construct accurate atomistic silica mesopore models for MCM-41 and perform molecular simulations (gauge cell Monte Carlo and grand canonical Monte Carlo) for argon adsorption on the models at subcritical temperatures. A careful comparison between the simulation and experiment reveals that the energy barrier for the capillary condensation has a critical dimensionless value, W{sub c}{sup *} = 0.175, which corresponds to the thermal fluctuation of the system and depends neither on the mesopore size nor on the temperature. We show that the critical energy barrier W{sub c}{sup *} controls the capillary condensation pressure P{sub cond} and also determines a boundary between the reversible condensation/evaporation regime and the developing hysteresis regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A streamer-like atmospheric pressure plasma jet

The properties of an atmospheric pressure plasma jet (APPJ) are examined in a single-cell dielectric capillary configuration. In contrast to some other flow-driven APPJs, this stable, cold plasma jet is electrically driven, composed of rapidly propagating ionization fronts with speeds of the order of 10{sup 7} cm/s. Using spatially and temporally resolved optical diagnostics, it is demonstrated that the plasma jet is initiated independent of the dielectric barrier discharge inside the capillary. It is also shown that the properties and dynamics of this APPJ are directly analogous to those of positive corona streamer discharges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Overview of NASA's In-Space Cryogenic Propellant Management Technologies

Future mission planning within NASA continues to include cryogenic propellants for in space transportation, with mission durations ranging from days to years. Between 1995 and the present, NASA has pursued a diversified program of ground-based testing to prepare the various technologies associated with in-space cryogenic fluid management (CFM) for implementation. CFM technology areas being addressed include passive insulation, zero gravity pressure control, zero gravity mass gauging, capillary liquid acquisition devices, and zero boiloff storage. NASA CFM technologies are planned, coordinated, and implemented through the Cryogenic Technology Working Group which is comprised of representatives from the various NASA Centers as well as the National Institute of Standards and Technologies (NIST) and, on selected occasions, the Air Force. An overview of the NASA program and Marshall Space Flight Center (MSFC) roles, accomplishments, and near-term activities are presented herein. Basic CFM technology areas being addressed include passive insulation, zero gravity pressure control, zero gravity mass gauging, capillary liquid acquisition devices, and zero boiloff storage. Recent MSFC accomplishments include: the large scale demonstration of a high performance variable density multilayer insulation (MLI) that reduced the boiloff by about half that of standard MLI; utilization of a foam substrate under MLI to eliminate the need for a helium purge bag system; demonstrations of both spray-bar and axial-jet mixer concepts for zero gravity pressure control; and sub-scale testing that verified an optical sensor concept for measuring liquid hydrogen mass in zero gravity. In response to missions requiring cryogenic propellant storage durations on the order of years, a cooperative effort by NASA's Ames Research Center, Glenn Research Center, and MSFC has been implemented to develop and demonstrate zero boiloff concepts for in-space storage of cryogenic propellants. An MSFC contribution to this cooperative effort is a large-scale demonstration of the integrated operation of passive insulation, destratification/pressure control, and cryocooler (commercial unit) subsystems to achieve zero boiloff storage of liquid hydrogen. Testing is expected during the Summer of 2001.

Tucker, Stephen↗

Control of optical transport parameters of 'porous medium – supercritical fluid' systems

The possibility of controlling optical transport parameters (in particular, transport scattering coefficient) of porous systems based on polymer fibres, saturated with carbon dioxide in different phase states (gaseous, liquid and supercritical) has been experimentally studied. An increase in the pressure of the saturating medium leads to a rise of its refractive index and, correspondingly, the diffuse-transmission coefficient of the system due to the decrease in the transport scattering coefficient. It is shown that, in the case of subcritical saturating carbon dioxide, the small-angle diffuse transmission of probed porous layers at pressures close to the saturated vapour pressure is determined by the effect of capillary condensation in pores. The immersion effect in 'porous medium – supercritical fluid' systems, where the fluid pressure is used as a control parameter, is considered. The results of reconstructing the values of transport scattering coefficient of probed layers for different refractive indices of a saturating fluid are presented. (radiation scattering)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The waveguide CO2 laser

A waveguide carbon dioxide laser is reported that is characterized by a very narrow capillary which contains the laser mix. The small capillary allows the device to be operated at pressures as high as 500 torr; pressure broadening of the molecular line is used for tuning. The capillary is placed between two reflectors which provide feedback for the laser oscillation.

Degnan, J. J., III↗

Gas-Liquid Flows Through Porous Media in Microgravity: The International Space Station Packed Bed Reactor Experiment

Experimental results on pressure drop and flow patterns for gas-liquid flow through packed beds obtained in the International Space Station with two types of packing are presented and analyzed. It is found that the pressure drop depends on the packing wettability in the viscous-capillary (V-C) regime and this dependence is compared with previously published results developed using short duration low-gravity aircraft tests. Within the V-C regime, the capillary contribution is the dominant force contributing to the pressure drop for the wetting case (glass) versus the viscous contribution dominating for the non-wetting case (Teflon). Outside of the V-C regime, it is also found that hysteresis effects that are often strong in normal gravity gas-liquid flows are greatly diminished in microgravity and pressure drop is nearly independent of packing wettability. A flow pattern transition map from bubble to pulse flow is also compared with the earlier aircraft data.

Viscous-capiliary regime↗

Glass 3D Printing of Microfluidic Pressure Sensor Interrogated by Fiber-Optic Refractometry

This letter reports a novel fused silica microfluidic device with pressure sensing capability that is fabricated by integrated additive and subtractive manufacturing (IASM) method. The sensor consists of a capillary and a 3D printed glass reservoir, where the reservoir volume change under pressure manifests liquid level deviation inside the capillary, thus realizing the conversion between small pressure change into large liquid level variation. Thanks to the design flexibility of this unique IASM method, the proposed microfluidic device is fabricated with liquid-in-glass thermometer configuration, where the reservoir is sealed following a novel 3D printing assisted glass bonding process. And liquid level is interrogated by a fiber-optic sensor based on multimode interference (MMI) effect. This proposed microfluidic device is attractive for chemical and biomedical sensing because it is flexible in design, and maintains good chemical and mechanical stability, and adjustable sensitivity and range.

42 ENGINEERING↗

Sodium Pumping via Condensation within a Non-Wetting Porous Structure

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity via the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle for this conversion process. A unique sodium capillary pump for the Na-TEC is proposed, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > 90o) stainless steel porous structure. Due to the curvature of the non-wetting liquid-vapor interface, the liquid adjacent to the interface is at a higher pressure than the vapor. This is in contrast to traditional wicks, where the liquid adjacent to the interface has a lower pressure. Thus, the curvature created at this non-wetting condensation interface supplies a directed force upon the liquid sodium that effectively “pushes” it towards a high pressure region, whereas a traditional capillary wick “pulls” the liquid. Porous structures made of stainless steel 316 are commercially available, and this material is non-wetting to sodium at the relevant temperature range of the Na-TEC condenser (500K – 673K). An experimental set-up is used to measure several interfacial and transport properties of the condensed sodium within this porous structure. These properties include the temperature dependent Laplace pressure generated at the phase change interface and the permeability of the porous structure. Liquid sodium is in contact with the porous structure and is progressively pressurized with argon gas until the sodium “breaks through” and the liquid begins to flow. This break-through pressure is determined when electrical contact is established between the flowing liquid metal and a set of electrodes cemented along the flow path. The velocity of the flowing sodium can also be measured with these electrodes, and the permeability is then determined by fitting velocity data to the classical Darcy law. These interfacial properties are then applied to a conjugate heat transfer model, which treats the coupled momentum and thermal transport processes within the non-wetting porous structure as sodium vapor is condensed. Due to the low mass flowrates in the Na-TEC (< 0.1 mg/s), higher order friction terms are neglected and the classical Darcy’s law is used for non-isothermal, compressible sodium vapor flow. At lower temperatures, the sodium vapor density becomes sufficiently small and there is a transition from classic Poiseuille flow (Kn < 0.1) to Knudsen flow (Kn > 10). Furthermore, transport due to binary diffusion is considered for situations where there is a substantial presence of non-condensable argon inside the sodium vapor plenum. Initial modeling results showing expected mass flowrates, temperature profiles, and liquid-vapor interface locations are presented for various physical conditions. Finally, the main design features of an experimental set-up used to demonstrate this capillary pumping is described in detail, including the method used to measure the low sodium mass flowrates. Initial experimental results demonstrating sodium pumping for a range of temperatures (800K – 1100K) will be presented and compared against the model predictions. A pump curve used to gauge the performance of this pumping mechanism is also created.

14 SOLAR ENERGY↗

Single-crystal silicon optical fiber by direct laser crystallization

Semiconductor core optical fibers with a silica cladding are of great interest in nonlinear photonics and optoelectronics applications. Laser crystallization has been recently demonstrated for crystallizing amorphous silicon fibers into crystalline form. Here we explore the underlying mechanism by which long single-crystal silicon fibers, which are novel platforms for silicon photonics, can be achieved by this process. Using finite element modeling, we construct a laser processing diagram that reveals a parameter space within which single crystals can be grown. Utilizing this diagram, we illustrate the creation of single-crystal silicon core fibers by laser crystallizing amorphous silicon deposited inside silica capillary fibers by high-pressure chemical vapor deposition. The single-crystal fibers, up to 5.1 mm long, have a very welldefined core/cladding interface and a chemically pure silicon core that leads to very low optical losses down to ~0.47-1dB/cm at the standard telecommunication wavelength (1550 nm). Furthermore, tt also exhibits a photosensitivity that is comparable to bulk silicon. Creating such laser processing diagrams can provide a general framework for developing single-crystal fibers in other materials of technological importance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long term orbital storage of cryogenic propellants for advanced space transportation missions

A comprehensive study has developed the major features of a large capacity orbital propellant depot for the space-based, cryogenic OTV. The study has treated both the Dual-Keel Space Station and co-orbiting platforms as the accommodations base for the propellant storage facilities, and trades have examined both tethered and hard-docked options. Five tank set concepts were developed for storing the propellants, and along with layout options for the station and platform, were evaluated from the standpoints of servicing, propellant delivery, boiloff, micrometeoroid/debris shielding, development requirements, and cost. These trades led to the recommendation that an all-passive storage concept be considered for the platform and an actively refrigerated concept providing for reliquefaction of all boiloff be considered for the Space Station. The tank sets are modular, each storing up to 45,400 kg of LO2/LH2, and employ many advanced features to provide for microgravity fluid management and to limit boiloff. The features include such technologies as zero-gravity mass gauging, total communication capillary liquid acquisition devices, autogenous pressurization, thermodynamic vent systems, thick multilayer insulation, vapor-cooled shields, solar-selective coatings, advanced micrometeoroid/debris protection systems, and long-lived cryogenic refrigeration systems.

Schuster, John R.↗

Interfacial and Transport Property Measurements of Liquid Sodium within a Porous Structure

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity via the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The transfer of liquid sodium from a low-pressure condenser to a high-pressure evaporator is necessary to complete the thermodynamic cycle for this conversion process. A unique sodium capillary pump for the Na-TEC is proposed, whereby low-pressure sodium vapor is condensed within a non-wetting (i.e. contact angle > π/2) porous sample. The curvature created at this non-wetting condensation interface supplies a directed force upon the liquid sodium that effectively “pushes” it towards a high pressure region, rather than a traditional capillary wick that “pulls” the liquid. Porous structures made of stainless steel 316 are commercially available, and this material is non-wetting to sodium at the relevant temperature range of the Na-TEC condenser (500K – 673K). An experimental set-up is used to measure several interfacial and transport properties of the condensed sodium within this porous structure. These properties include the temperature dependent Laplace pressure generated at the phase change interface and the permeability of the porous structure. For the former, liquid sodium is in contact with the porous structure and is progressively pressurized with argon gas in increments of ~ 5 kPa until the sodium “breaks through” and the liquid begins to flow. This breakthrough pressure is determined when electrical contact is established between the flowing liquid metal and a set of electrodes cemented into the flow path. The velocity of the flowing sodium can also be measured with these electrodes, and the permeability is then determined by fitting velocity data to the classical Darcy law. Statistically significant results of these measurements, taken at multiple sodium temperatures, are presented. Furthermore, contact angle measurements of sessile sodium drops on stainless steel 316 are demonstrated. This contact angle information is used to define an effective pore radius for the porous structure, which is then validated with microscopy. All the physical parameters described herein are used as inputs in a condensation model to predict the mass flowrate of condensing sodium under a given pressure gradient across the porous structure. This condensation model is used to design the capillary pump for the Na-TEC.

14 SOLAR ENERGY↗

High lung volume increases stress failure in pulmonary capillaries

We previously showed that when pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to test whether stress failure occurred more frequently at high than at low lung volumes for the same Ptm. Lungs of anesthetized rabbits were inflated to a transpulmonary pressure of 20 cmH2O, perfused with autologous blood at 32.5 or 2.5 cmH2O Ptm, and fixed by intravascular perfusion. Samples were examined by both transmission and scanning electron microscopy. The results were compared with those of a previous study in which the lung was inflated to a transpulmonary pressure of 5 cmH2O. There was a large increase in the frequency of stress failure of the capillary walls at the higher lung volume. For example, at 32.5 cmH2O Ptm, the number of endothelial breaks per millimeter cell lining was 7.1 +/- 2.2 at the high lung volume compared with 0.7 +/- 0.4 at the low lung volume. The corresponding values for epithelium were 8.5 +/- 1.6 and 0.9 +/- 0.6. Both differences were significant (P less than 0.05). At 52.5 cmH2O Ptm, the results for endothelium were 20.7 +/- 7.6 (high volume) and 7.1 +/- 2.1 (low volume), and the corresponding results for epithelium were 32.8 +/- 11.9 and 11.4 +/- 3.7. At 32.5 cmH2O Ptm, the thickness of the blood-gas barrier was greater at the higher lung volume, consistent with the development of more interstitial edema. Ballooning of the epithelium caused by accumulation of edema fluid between the epithelial cell and its basement membrane was seen at 32.5 and 52.5 cmH2O Ptm. At high lung volume, the breaks tended to be narrower and fewer were oriented perpendicular to the axis of the pulmonary capillaries than at low lung volumes. Transmission and scanning electron microscopy measurements agreed well. Our findings provide a physiological mechanism for other studies showing increased capillary permeability at high states of lung inflation.

Non-NASA Center↗

Final Report for CRADA Agreement , AL-C-2006-01 with Microsens Biotechnologies: Detection of the Abnormal Prion Protein in Blood by Improving the Extraction of this Protein

Several conditions were examined to optimize the extraction protocol using Seprion beads for the abnormal prion protein. Different combinations of water, hexafluro-2-propanol and formic acid were used. The results of these extraction protocols showed that the magnetic beads coated with Seprion reagents were subject to degradation, themselves, when the extraction conditions that would solubilize the abnormal prion protein were used. These compounds caused interference in the immunoassay for the abnormal prion protein and rendered these protocols incompatible with the assay systems. In an attempt to overcome this problem, another approach was then used. The coated beads were used as an integral part of the assay platform. After washing away denaturing agents, the beads with the 'captured' abnormal prion were incubated directly in the immunoassay, followed by analysis by the capillary electrophoresis. When a capillary electrophoresis electro-kinetic separation was attempted, the beads disturbed the analysis making it impossible to interpret. A pressure separation method was then developed for capillary electrophoresis analysis. When 20 samples, 5 of which were positive were analyzed, the assay identified 4 of the 5 positives and had no false positives. When a larger number of samples were analyzed the results were not as good - there were false positives and false negatives. It was then observed that the amount of beads that were loaded was dependent upon how long the beads were allowed to settle before loading them into the capillary. This resulted in unacceptable variations in the results and explained that when large numbers of samples were evaluated the results were not consistent. Because the technical difficulties with using the Seprion beads could not be overcome at this time, another approach is underway that is outside of the scope of this CRADA. No further agreements have been developed. Because the results were not favorable, no manuscripts were written nor intellectual property developed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Propagation of a Liquid Bolus Through an Elastic Tube and Airway Reopening

We use lubrication theory and matched asymptotic expansions to model the quasi-steady propagation of a liquid bridge through an elastic tube. In the limit of small capillary number, asymptotic expressions are found for the pressure drop across the bridge and the thickness of the liquid film left behind, as functions of the capillary number, the thickness of the liquid lining ahead of the bridge and the elastic characteristics of the tube wall. For a given precursor thickness, we find a critical propagation speed, and hence a critical imposed pressure drop, above which the bridge will eventually burst, and hence the tube will reopen.

Howell, Peter D.↗