Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Computational Design of Metal-Organic Frameworks Based on Stable Zirconium Building Units for Storage and Delivery of Methane

A metal organic framework (MOF) with high volumetric deliverable capacity for methane was synthesized after being identified by computational screening of 204 hypothetical MOF structures featuring (Zr6O4)(OH)(4)(CO2)(n) inorganic building blocks. The predicted MOF (NU-800) has an fcu topology in which zirconium nodes are connected via ditopic 1,4-benzenedipropynoic acid linkers. Based on our computer simulations, alkyne groups adjacent to the inorganic zirconium nodes provide more efficient methane packing around the nodes at high pressures. The high predicted gas uptake properties of this new MOF were confirmed by high-pressure isotherm measurements over a large temperature and pressure range. The measured methane deliverable capacity of NU-800 between 65 and 5.8 bar is 167 cc(STP)/cc (0.215 g/g), the highest among zirconium-based MOFs. High-pressure uptake values of H-2 and CO2 are also among the highest reported. These high gas uptake characteristics, along with the expected highly stable structure of NU-800, make it a promising material for gas storage applications.

Gomez-Gualdron, DA↗

Empirical validation and comparison of methodologies to simulate micro and macro-encapsulated PCMs in the building envelope

Thermal Energy Storage (TES) has the potential to shift peak electricity demand. Passive TES is usually implemented in building envelope as micro and macro encapsulated phase change materials (PCM) to shift electric energy demand and therefore requires careful heat transfer analysis. Whole building energy modelling with simplified heat transfer analysis has become extremely important for designers, architects, engineers, and researchers to predict energy performance of buildings. It is important to validate PCM modelling algorithms used in building energy programs to quantify their error and prove their capacity to model different PCM encapsulation types. This study uses data from a microencapsulated PCM and two macroencapsulated PCMs (Bio based PCM and hydrate salts) tested in full-scale using the Advanced Multiscale Building Energy Research (AMBER) Lab located at the Colorado School of Mines and is used to validate a numerical algorithm written in MATLAB language. To approximate the heat transfer through a wall assembly with macroencapsulated PCM pouches, several modelling techniques that can reduce 3D heat transfer characteristics to 1D are explored in this research. A parallel path heat transfer modelling approach is found to give the closest agreement with the experimental data for the pouched PCMs in building envelope applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulated building energy demand biases resulting from the use of representative weather stations

Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. We quantify the potential reduction in bias from using an increasing number of weather stations over the western U.S. The approach is based on deriving temperature and load time series using incrementally more weather stations, ranging from 8 to roughly 150, to capture weather across different seasons. Using 8 stations, one from each climate zone, across the western U.S. results in an average absolute summertime temperature bias of 7.2°F with respect to a spatially-resolved gridded dataset. The mean absolute bias drops to 2.8°F using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.8%, a significant error for capacity expansion planners who may use these types of simulations. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20-40% overestimation of peak building loads during both summer and winter. Using weather stations close to population centers reduces both mean and peak load biases. This approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.

Burleyson, Casey D.↗

Normal mode description of phases of matter: Application to heat capacity

Understanding thermodynamics in liquids at the atomic level is challenging because of strong atomic interactions and lack of spatial symmetry. Recent prior theoretical works have focused on describing heat capacity of liquids in terms of phonon-like excitations but often rely on fitting factors and assumptions. In this work, we propose characterizing various phases in terms of instantaneous normal modes (INMs) of structural snapshots from molecular dynamics simulations of single-element systems over wide ranges of temperature and pressure. We use the INMs to build a mode-level microscopic description of heat capacity and demonstrate that heat capacity of liquids can be described by a combination of both solidlike and gaslike degrees of freedom, leading to a more unified framework to fundamentally describe heat capacity of all three phases of matter: solid, liquid, and gas. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic Thermal Performance Analysis of PCM Products Used for Energy Efficiency and Internal Climate Control in Buildings

PCMs are attractive for the future generation of buildings, where energy efficiency targets and thermal comfort expectations are increasingly prioritized. Experimental analysis of local thermal processes in these dynamic components and whole-building energy consumption predictions are essential for the proper implementation of PCMs in buildings. This paper discusses the experimental analysis of the thermophysical characteristics of both a latent heat storage material (PCM) and a product containing this PCM. The prototype product under investigation is a panelized PCM technology containing inorganic, salt-hydrate-based PCM. The thermal analysis includes studies of melting and freezing temperatures, enthalpy changes during phase change processes, nucleation intensity, sub-cooling effects, and PCM stability. The PCM’s stability is also investigated, as is the ability of PCM products to control local temperatures and peak load transmission times. Two inorganic PCM formulations based on calcium chloride hexahydrate (CaCl 2 .6H 2 O) were prepared and tested in laboratory conditions. Material-scale testing results were compared with outcomes from the system-scale analysis, using both laboratory test methods as well as field exposure in test huts. This work demonstrates that PCM technologies used in buildings can effectively control both the magnitude of thermal storage capacity as well as the time of the peak thermal load. It was found that commonly used material-scale testing methods may not always be beneficial in assessing the dynamic thermal performance characteristics of building technologies containing PCMs.

42 ENGINEERING↗

Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

Building Energy Simulation↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bio-Based Phase Change Materials (PCMs) for Thermal Energy Storage (Final Scientific/Technical Report)

The goal of this project is to develop a novel bio-based phase change material (PCM) derived from squid ring teeth (SRT) proteins, and design a prototype heat exchanger based on these bio-based PCMs for energy storage and dynamic heat exchange for building thermal energy storage systems. The PCMs, derived from SRT proteins, will demonstrate room temperature energy storage capacities and switchable thermal conductivities that redefine the current state-of-the-art (SOA) for building thermal energy storage. Further, in a single material and with a single manufacturing processes, our proposed thermal battery will be developed with “on demand” thermal conductivity for rapid charging/discharging but superior insulation during energy storage periods. More specifically, our bio-based PCMs have demonstrated: 1) the potential for increased energy storage capacity (i.e., greater than paraffines at room temperature); 2) tunability in thermal conductivity with the largest thermal conductivity switching ratios for an intrinsic material reported to date, and 3) a 100% recyclable and biodegradable PCM with low volatility and toxicity and scalability in its manufacture for both residential and commercial applications. The already established ability for roll-to-roll processing of these non-toxic, non-flammable SRT composites along with their carbon-neutral manufacturing processes that has been pioneered by our team make this solution a disruptive and impactful technology to redefine the current SOA of energy storage technologies. The outcomes of this effort have been: 1) the identification of new bio-based PCM that establishes a new SOA for thermal conductivity and energy storage density at room temperature and 2) the development of a new experimental technique to measure the energy storage density via latent heat measurements during melting of thin films. This new technique can be applied to thin films (as thin as < 1 micrometer), and represents a novel approach for thin film energy storage density measurements. Dynamic thermal energy storage is the missing technology that will enable a grid- interactive efficient building (GEB). For a “smart” building capable of connecting with the power grid, the media must be inexpensive and possess thermal switching capabilities to control the time-dependent heat flow into (and out of) the PCM on demand. Unique to the material system in this program, programmable SRT-based PCM show improvements as compared to traditionally used PCMs, and thus its technical performance will represent a leap forward for the future GEB concept.

25 ENERGY STORAGE↗

Winds of fortune? Understanding the geographic, sociodemographic, and temporal distribution of benefit mechanisms from land-based wind projects in the United States

Despite decades of research on factors shaping local responses to wind development, there is relatively little known about benefit mechanisms (e.g., agreements, funds, donations) used by developers in the U.S. land-based wind sector. To address this gap, we collected benefit mechanism data across all current utility-scale land-based wind projects installed between 1982 and 2024 (n = 1047), finding that just under one-third of projects had a benefit mechanism attached to them. We find the use of benefit mechanisms has become more common over time, is associated with larger projects, and varies by region. In terms of host community characteristics, the use of benefit mechanisms is associated with characteristics like higher education level, higher percent white, higher percent Republican, higher decision-making capacity, lower unemployment rate, and higher poverty rate. Building on a theoretical framework of purposes, we discuss what these findings could suggest about the motivations driving developers' use of these mechanisms, such as increasing local acceptance of a wind project or supporting distributive fairness. This first-of-its-kind study builds a comprehensive understanding of how benefit mechanisms have been used in the U.S. wind industry throughout its history, which can inform future approaches to benefit-sharing across sectors.

17 WIND ENERGY↗

Climate change and its influence on water systems increases the cost of electricity system decarbonization

The electric sector simultaneously faces two challenges: decarbonization to mitigate, and adaptation to manage, the impacts of climate change. In many regions, these challenges are compounded by an interdependence of electricity and water systems, with water needed for hydropower generation and electricity for water provision. Here, we couple detailed water and electricity system models to evaluate how the Western Interconnection grid can both adapt to climate change and develop carbon-free generation by 2050, while accounting for interactions and climate vulnerabilities of the water sector. We find that by 2050, due to climate change, annual regional electricity use could grow by up to 2% from cooling and water-related electricity demand, while total annual hydropower generation could decrease by up to 23%. To adapt, we show that the region may need to build up to 139 GW of additional generating capacity between 2030 and 2050, equivalent to nearly thrice California's peak demand, and could incur up to $\$$150 billion (+7%) in extra costs.

13 HYDRO ENERGY↗

Enhance indigenous agricultural systems to reduce migration

Changes in social and environmental conditions in the Western Highlands of Guatemala undermine food security and job opportunities. Here, we describe how targeted assistance can build upon traditional agricultural systems to increase adaptive capacity, improve nutrition, provide jobs and thereby reduce pressures to migrate.

54 ENVIRONMENTAL SCIENCES↗

Behind-the-meter Infrastructure Costs for Electrification Progression (BICEP) Model

The Behind-the-meter Infrastructure Costs for Electrification Progression (BICEP) model quantifies the behind-the-meter (BTM) electrical upgrades required for decarbonization through electrification by comparing the expected change in capacity requirements from the electrification technologies to the existing capacity in distributed energy resources (DER) stock (including buildings).

Yoder, Tim↗

Advanced Epi Tools for Gallium Nitride Light Emitting Diode Devices

Over the course of this program, Applied Materials, Inc., with generous support from the United States Department of Energy, developed a world-class three chamber III-Nitride epi cluster tool for low-cost, high volume GaN growth for the solid state lighting industry. One of the major achievements of the program was to design, build, and demonstrate the world’s largest wafer capacity HVPE chamber suitable for repeatable high volume III-Nitride template and device manufacturing. Applied Materials’ experience in developing deposition chambers for the silicon chip industry over many decades resulted in many orders of magnitude reductions in the price of transistors. That experience and understanding was used in developing this GaN epi deposition tool. The multi-chamber approach, which continues to be unique in the ability of the each chamber to deposit a section of the full device structure, unlike other cluster tools, allows for extreme flexibility in the manufacturing process. This robust architecture is suitable for not just the LED industry, but GaN power devices as well, both horizontal and vertical designs. The new HVPE technology developed allows GaN to be grown at a rate unheard of with MOCVD, up to 20x the typical MOCVD rates of 3{micro}m per hour, with bulk crystal quality better than the highest-quality commercial GaN films grown by MOCVD at a much cheaper overall cost. This is a unique development as the HVPE process has been known for decades, but never successfully commercially developed for high volume manufacturing. This research shows the potential of the first commercial-grade HVPE chamber, an elusive goal for III-V researchers and those wanting to capitalize on the promise of HVPE. Additionally, in the course of this program, Applied Materials built two MOCVD chambers, in addition to the HVPE chamber, and a robot that moves wafers between them. The MOCVD chambers demonstrated industry-leading wavelength yield for GaN based LED wafers and industry-leading uptime enabled in part by a novel in-situ cleaning process developed in this program.

36 MATERIALS SCIENCE↗

Launch Alaska Transportation and Energy Accelerator (LATEA)

The Launch Alaska Transportation and Energy Accelerator (LATEA), funded through the U.S. Department of Energy Office of Technology Commercialization’s Energy Program for Innovation Clusters (EPIC),advanced deployment of innovative and efficient transportation and energy technology in Alaska from October 2021 through June 2025. The project was designed to leverage Launch Alaska’s accelerator model to identify, recruit, and support transportation technology companies with novel solutions to market needs while building the stakeholder networks, demonstration opportunities, and institutional capacity necessary to accelerate commercialization in one of the most challenging operating environments in the United States.

08 HYDROGEN↗

Data Centers in the Commercial Sector

This fact sheet summarizes some of the key needs, barriers, and opportunities related to data center management and operations in the Commercial Sector.

data center, data center management, commercial bu↗

Cooling and Heating Season Impacts of Right-Sizing of Fixed- and Variable-Capacity Heat Pumps With Attic and Indoor Ductwork

A new generation of full variable-capacity air-conditioning (A/C) and heat pump units has come on the market that promises to deliver very high cooling and heating efficiency. The units are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and cycling off when the thermostat is satisfied, the new units can vary their capacity over a wide range (approximately 40%–118% of nominal full capacity) and stay on for 60%–100% more hours per day than the fixed-capacity systems depending on load-to-capacity ratios. Two-stage systems were not evaluated in this research effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Findings of the South Africa Power System Capacity Expansion and Operational Modelling Study: Preprint

Wind and solar power contract prices have recently become cheaper than many conventional new-build alternatives in South Africa and trends suggest a continued increase in the share of variable renewable energy (vRE) on South Africa's power system with coal technology seeing the greatest reduction in capacity, see 'Figure 6: Percentage share by Installed Capacity (MW)' in [1]. Hence it is essential to perform a state-of-the-art grid integration study examining the effects of these high penetrations of vRE on South Africa's power system. Under the 21st Century Power Partnership (21CPP), funded by the U.S. Department of Energy, the National Renewable Energy Laboratory (NREL) has significantly augmented existing models of the South African power system to investigate future vRE scenarios. NREL, in collaboration with Eskom's Planning Department, further developed, tested and ran a combined capacity expansion and operational model of the South African power system including spatially disaggregated detail and geographical representation of system resources. New software to visualize and interpret modelling outputs has been developed, and scenario analysis of stepwise vRE build targets reveals new insight into associated planning and operational impacts and costs. The model, built using PLEXOS, is split into two components, firstly a capacity expansion model and secondly a unit commitment and economic dispatch model. The capacity expansion model optimizes new generation decisions to achieve the lowest cost, with a full understanding of capital cost and an approximated understanding of operational costs. The operational model has a greater set of detailed operational constraints and is run at daily resolutions. Both are run from 2017 through 2050. This investigation suggests that running both models in tandem may be the most effective means to plan the least cost South African power system as build plans seen to be more expensive than optimal by the capacity expansion model can produce greater operational cost savings seen only in the operational model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Investigation of an Air-Source Cold Climate Heat Pump

In the U.S., there are approximately 2.6 million dwellings that use electricity for heating in cold and very cold regions with an annual energy consumption of 0.16 quads (0.17 EJ). A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (greater than 60% compared to electric resistance heating). We developed an air-source cold climate heat pump, which uses tandem compressors, with a single compressor rated for the building design cooling load, and running two compressors to provide, at -13 F (-25 C), 75% of rated heating capacity. The tandem compressors were optimized for heating operation and are able to tolerate discharge temperatures up to 280 F (138 C). A field investigation was conducted in the winter of 2015, in an occupied home in Ohio, USA. During the heating season, the seasonal COP was measured at 3.16, and the heat pump was able to operate down to -13 F (-25 C) and eliminate resistance heat use. The heat pump maintained an acceptable comfort level throughout the heating season. In comparison to a previous single-speed heat pump in the home, the CCHP demonstrated more than 40% energy savings in the peak heating load month. This paper illustrates the measured field performance, including compressor run time, frost/defrosting operations, distributions of building heating load and capacity delivery, comfort level, field measured COPs, etc.

Cold Climate Heat Pump↗