Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

High Spectral Resolution, High Cadence, Imaging X-Ray Microcalorimeters for Solar Physics

High spectral resolution, high cadence, imaging x-ray spectroscopy has the potential to revolutionize the study of the solar corona. To that end we have been developing transition-edge-sensor (TES) based x-ray micro calorimeter arrays for future solar physics missions where imaging and high energy resolution spectroscopy will enable previously impossible studies of the dynamics and energetics of the solar corona. The characteristics of these x-ray microcalorimeters are significantly different from conventional micro calorimeters developed for astrophysics because they need to accommodate much higher count rates (300-1000 cps) while maintaining high energy resolution of less than 4 eV FWHM in the X-ray energy band of 0.2-10 keV. The other main difference is a smaller pixel size (less than 75 x 75 square microns) than is typical for x-ray micro calorimeters in order to provide angular resolution less than 1 arcsecond. We have achieved at energy resolution of 2.15 eV at 6 keV in a pixel with a 12 x 12 square micron TES sensor and 34 x 34 x 9.1 micron gold absorber, and a resolution of 2.30 eV at 6 keV in a pixel with a 35 x 35 micron TES and a 57 x 57 x 9.1 micron gold absorber. This performance has been achieved in pixels that are fabricated directly onto solid substrates, ie. they are not supported by silicon nitride membranes. We present the results from these detectors, the expected performance at high count-rates, and prospects for the use of this technology for future Solar missions.

Bandler, Simon R.↗

Magnetic Microcalorimeter Gamma Detectors for High-Precision Non-Destructive Analysis

Cryogenic gamma (γ) detectors with operating temperatures of ~0.1 K offer 10× better energy resolution than conventional high-purity germanium detectors that are currently used for non-destructive analysis (NDA) of nuclear materials. This can greatly increase the accuracy of NDA, especially at low-energies where gamma rays often have similar energies and cannot be resolved by Ge detectors. Among the different cryogenic detector types, Magnetic Micro-Calorimeters (MMCs) have the potential of faster count rates and better linearity. High linearity is essential to add spectra from different pixels in detector arrays that are needed for high sensitivity. MMC gamma detectors measure the energy of absorbed gamma rays form the resulting change in magnetization of an erbium-doped gold (Au:Er) sensor. The signal is read out with a SQUID preamplifier and processed digitally with room temperature electronics (see inset figure 2). The objective of this project is to develop ultra-high energy resolution γ-detectors based on magnetic micro-calorimeters (MMCs) for accurate non-destructive isotope analysis (NDA). Since MMCs, like other cryogenic γ-detector technologies with operating temperatures <0.1 K, are intrinsically slow and have to be small for high resolution, special emphasis will be placed on questions that determine sensitivity and the potential for scaling to arrays. Objectives for FY14 were therefore to fabricate an improved version of MMC γ-detectors and test their energy resolution, maximum count rate, readout noise, crosstalk between pixels and linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence of circumstellar matter surrounding the Hercules X-1 system

We analyze data from two eclipse ingresses of Her X-1 observed with Ginga on 1989 April 30 and May 19. These observations occur, respectively, during the MAIN HIGH and SHORT HIGH states in the 35 day modulation of Her X-1 intensity. We find significant residual X-ray flux during eclipse, with a gradual decrease in flux following the occultation of the neutron star by the atmosphere of HZ Her. During the central part of the eclipse the count rate becomes nearly constant, at 0.5 mCrab in the energy range 1.7-36.8 keV. From a spectral analysis of the residual emission during the total eclipse of the central source in the MAIN HIGH state, we determine the energy spectral index, alpha = 0.8, similar to that before eclipse. A remarkable feature of the eclipse spectrum is that it does not show a significant iron line feature in contrast to massive wind-fed pulsars, such as Vela X-1 and Cen X-3. From a timing analysis of the same eclipse data, we show that there are no pulses. These results imply that the emission comes from the scattering of continuum X-rays by material in a region considerably larger than the companion star. An extended accretion disk corona may be responsible for this scattering. However, partial eclipse of an extended accretion disk corona may be responsible for this scattering. However, partial eclipse of an extended accretion disk corona is insufficient to account for the count rates in mid-eclipse, when known parameters of the binary system are used. Based on the present results, we suggest that scattering occurs not only in the accretion disk corona but also in the circumstellar matter surrounding the system of Her X-1/HZ Her.

Choi, C. S.↗

On the possibility to detect multipolar order in URu 2 Si 2 by the electric quadrupolar transition of resonant elastic x-ray scattering

Resonant elastic x-ray scattering is a powerful technique for measuring multipolar order parameters. In this paper, we theoretically and experimentally study the possibility of using this technique to detect the proposed multipolar order parameters in URu 2 Si 2 at the U- L 3 edge with the electric quadrupolar transition. Based on an atomic model, we calculate the azimuthal dependence of the quadrupolar transition at the U- L 3 edge. Our results illustrate the potential of this technique for distinguishing different multipolar order parameters. We then perform experiments on ultraclean single crystals of URu 2 Si 2 at the U- L 3 edge to search for the predicted signal, but do not detect any indications of multipolar moments within the experimental uncertainty. We also theoretically estimate the orders of magnitude of the cross section and the expected count rate of the quadrupolar transition and compare them to the dipolar transitions at the U- M 4 and U- L 3 edges, clarifying the difficulty in detecting higher order multipolar order parameters in URu 2 Si 2 in the current experimental setup.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Recent Developments in Fast Neutron Detection and Multiplicity Counting with Liquid Scintillator

For many years, LLNL researchers have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of the techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, thermal neutron detectors (mainly {sup 3}He) were used, taking advantage of the high thermal neutron interaction cross sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics that respond over 1000 times faster (ns versus tens of {mu}s) than thermal neutron detectors. Fast neutron detection offers considerable advantages since the inherent ns production timescales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Method to Estimate the Atomic Number and Mass Thickness of Intervening Materials in Uranium and Plutonium Gamma-Ray Spectroscopy Measurements

To accurately characterize shielded special nuclear materials (SNM) using passive gamma-ray spectroscopy measurement techniques, the effective atomic number and the thickness of shielding materials must be measured. Intervening materials between the source and detector may affect the estimated source isotopics (uranium enrichment and plutonium grade) for techniques which rely on raw count rates or photopeak ratios of gamma-ray lines separated in energy. Furthermore, knowledge of the surrounding materials can provide insight regarding the configuration of a device containing SNM. The described method was developed using spectra recorded using high energy resolution CdZnTe detectors, but can be expanded to any gamma-ray spectrometers with energy resolution of better than 1% FWHM at 662 keV. The effective atomic number, Z, and mass thickness of the intervening shielding material are identified by comparing the relative attenuation of different gamma-ray lines and estimating the proportion of Compton scattering interactions to photoelectric absorptions within the shield. While characteristic Kα x-rays can be used to identify shielding materials made of high Z elements, this method can be applied to all shielding materials. This algorithm has adequately estimated the effective atomic number for shields made of iron, aluminum, and polyethylene surrounding uranium samples using experimental data. The mass thicknesses of shielding materials have been estimated with a standard error of less than 1.3 g/cm2 for iron shields up to 2.5 cm thick. The effective atomic number was accurately estimated to 26 ± 5 for all iron thicknesses.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness assessment of the charge-integrating hybrid pixel detector JUNGFRAU 1.0 for photon science

JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications in free electron lasers, particularly SwissFEL, and synchrotron light sources. JUNGFRAU is an automatic gain switching, charge-integrating detector which covers a dynamic range of more than 10{sup 4} photons of an energy of 12 keV with a good linearity, uniformity of response, and spatial resolving power. The JUNGFRAU 1.0 application-specific integrated circuit (ASIC) features a 256 × 256 pixel matrix of 75 × 75 μm{sup 2} pixels and is bump-bonded to a 320 μm thick Si sensor. Modules of 2 × 4 chips cover an area of about 4 × 8 cm{sup 2}. Readout rates in excess of 2 kHz enable linear count rate capabilities of 20 MHz (at 12 keV) and 50 MHz (at 5 keV). The tolerance of JUNGFRAU to radiation is a key issue to guarantee several years of operation at free electron lasers and synchrotrons. The radiation hardness of JUNGFRAU 1.0 is tested with synchrotron radiation up to 10 MGy of delivered dose. The effect of radiation-induced changes on the noise, baseline, gain, and gain switching is evaluated post-irradiation for both the ASIC and the hybridized assembly. The bare JUNGFRAU 1.0 chip can withstand doses as high as 10 MGy with minor changes to its noise and a reduction in the preamplifier gain. The hybridized assembly, in particular the sensor, is affected by the photon irradiation which mainly shows as an increase in the leakage current. Self-healing of the system is investigated during a period of 11 weeks after the delivery of the radiation dose. Annealing radiation-induced changes by bake-out at 100 °C is investigated. It is concluded that the JUNGFRAU 1.0 pixel is sufficiently radiation-hard for its envisioned applications at SwissFEL and synchrotron beam lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event

The performance of the Radionuclide Aerosol Sampler/Analyzer (RASA) under high-activity conditions has been evaluated to maintain and protect the operations of International Monitoring System (IMS) radionuclide stations. Station measurements following the Fukushima Daichi accident of 11 March 2011 have been combined with laboratory measurements to understand how the quality of the measurements made using the RASA High-Purity Germanium (HPGe) gamma-spectrometer are impacted by increased sample activity and detector dead-time. Detector saturation has been identified to occur at a count rate of 175,000 counts s-1, at which level there are significant impacts to the sample live-time and detector resolution in addition to a system contamination risk. To safeguard against these effects, a dead-time limit of 16.6% is proposed that could be maintained by monitoring the activity collecting on the filter using a Cadmium Zinc Telluride (CZT) detector installed into the particulate collection area of the RASA. This limit would ensure that the IMS technical specifications for measurement time (> 20 h) and detector resolution (2.5 keV at 1332 keV) are met. The CZT would dynamically control the RASA air flow to limit the collection of particulate activity beneath the HPGe dead-time threshold and would also provide measurements useful for CTBT verification purposes and dose assessments.

Burnett, Jonathan L.↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-07: Evaluating the Adequacy of Biopsy Specimens for Genetic Signature Assessment by Measuring the Metabolic Activity in Specimens Obtained Under 18F-FDG PET/CT Guidance

Purpose: Genetic profiling of biopsied tissue is the basis for personalized cancer therapy. However biopsied materials may not contain sufficient amounts of DNA needed for analysis. We propose a method to determine the adequacy of specimens for performing genetic profiling by quantifying metabolic activity. Methods: We measured the response of two radiation detectors to the activity contained in the minimum amount of tumor cells needed for genetic profiling in biopsy specimens obtained under 2-deoxy-2-({sup 18}F)fluoro-D-glucose ({sup 18}F-FDG) PET/CT guidance. The expected tumor cell concentration in biopsy specimens was evaluated from the amount of DNA needed (∼100 µg) and the number of pathology sections typically used for the analysis. The average {sup 18}F-FDG uptake per cell was measured by incubating KPC-4662 pancreatic tumor cells and HT-29 colorectal adenocarcinoma tumor cells in {sup 18}F-FDG containing solution (activity concentrations between 0.0122 and 1.51 MBq/mL and glucose concentrations of 3.1 and 1 g/L) for 1 to 1.75 hours and then measuring the activity of a known number of cells. Measurements of surrogate specimens obtained using 18G needle biopsies of gels containing these cells in expected concentrations (∼10{sup 4} µL{sup −1}) were performed using an autoradiography CCD based device (up to 20 min exposure) and a scintillation well counter (∼1 min measurements) about 3 and 5 hours after the end of incubation respectively. Results: At start of autoradiography there were between 0.16 and 1.5 {sup 18}F-FDG molecules/cell and between 1.14 and 5.43×10{sup 7} {sup 18}F-FDG molecules/mL. For the scintillation well counter, sample to minimum-detectable-count rate ratios were greater than 7 and the counting error was less than 25% for ≤80 s measurement times. Images of the samples were identifiable on the autoradiograph for ∼10 min and longer exposure times. Conclusion: Scintillation well counter measurements and CCD based autoradiography have adequate sensitivity to detect the tumor burden needed for genetic profiling in 18G core needle biopsies. Supported in part through the NIH/NCI Cancer Center Support Grant P30 CA008748 and by a sponsored research agreement with Biospace Lab S.A.

60 APPLIED LIFE SCIENCES↗

High-speed imaging at high x-ray energy: CdTe sensors coupled to charge-integrating pixel array detectors

Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we describe the hybridization of CdTe sensors to two different charge-integrating readout chips, the Keck PAD and the Mixed-Mode PAD (MM-PAD), both developed previously in our laboratory. The charge-integrating architecture of each of these PADs extends the instantaneous counting rate by many orders of magnitude beyond that obtainable with photon counting architectures. The Keck PAD chip consists of rapid, 8-frame, in-pixel storage elements with framing periods <150 ns. The second detector, the MM-PAD, has an extended dynamic range by utilizing an in-pixel overflow counter coupled with charge removal circuitry activated at each overflow. This allows the recording of signals from the single-photon level to tens of millions of x-rays/pixel/frame while framing at 1 kHz. Both detector chips consist of a 128×128 pixel array with (150 µm){sup 2} pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryptographic robustness of a quantum cryptography system using phase-time coding

A cryptographic analysis is presented of a new quantum key distribution protocol using phase-time coding. An upper bound is obtained for the error rate that guarantees secure key distribution. It is shown that the maximum tolerable error rate for this protocol depends on the counting rate in the control time slot. When no counts are detected in the control time slot, the protocol guarantees secure key distribution if the bit error rate in the sifted key does not exceed 50%. This protocol partially discriminates between errors due to system defects (e.g., imbalance of a fiber-optic interferometer) and eavesdropping. In the absence of eavesdropping, the counts detected in the control time slot are not caused by interferometer imbalance, which reduces the requirements for interferometer stability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryptographic robustness of a quantum cryptography system using phase-time coding

A cryptographic analysis is presented of a new quantum key distribution protocol using phase-time coding. An upper bound is obtained for the error rate that guarantees secure key distribution. It is shown that the maximum tolerable error rate for this protocol depends on the counting rate in the control time slot. When no counts are detected in the control time slot, the protocol guarantees secure key distribution if the bit error rate in the sifted key does not exceed 50%. This protocol partially discriminates between errors due to system defects (e.g., imbalance of a fiber-optic interferometer) and eavesdropping. In the absence of eavesdropping, the counts detected in the control time slot are not caused by interferometer imbalance, which reduces the requirements for interferometer stability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UNDERSTANDING AGN-HOST CONNECTION IN PARTIALLY OBSCURED ACTIVE GALACTIC NUCLEI. III. PROPERTIES OF ROSAT-SELECTED SDSS ACTIVE GALACTIC NUCLEI

As the third paper of our series of studies that aim at examining the AGN-host co-evolution by using partially obscured active galactic nuclei (AGNs), we extend the broad-line composite galaxies (composite AGNs) into ROSAT-selected Seyfert 1.8/1.9 galaxies based upon the ROSAT All Sky Survey/Sloan Digital Sky Survey Data Release 5 (SDSS-DR5) catalog given by Anderson et al. The SDSS spectra of a total of 92 objects are analyzed by the same method used in our previous studies, after requiring the signal-to-noise ratio in the SDSS r' band to be larger than 20. Combining the ROSAT-selected Seyfert galaxies with the composite AGNs reinforces the tight correlation between the line ratio [O I]/H{alpha} versus D{sub n} (4000), and establishes a new tight correlation between [S II]/H{alpha} versus D{sub n} (4000). Both correlations suggest that the two line ratios are plausible age indicators of the circumnuclear stellar population for typical Type I AGNs in which the stellar populations are difficult to derive from their optical spectra. The ROSAT-selected Seyfert galaxies show that the two correlations depend on the soft X-ray spectral slope {alpha} {sub X}, which is roughly estimated from the hardness ratios by requiring that the X-ray count rates within 0.1-2.4 keV be larger than 0.02 counts s{sup -1}. However, we fail to establish a relationship between {alpha} {sub X} and D{sub n} (4000), which is likely caused by the relatively large uncertainties of both the parameters (especially for {alpha} {sub X} because of the AGN intrinsic obscuration). The previously established L/L {sub Edd}-D{sub n} (4000) evolutionary sequence is reinforced again by the extension to the ROSAT-selected Seyfert galaxies. These X-ray-selected Seyfert galaxies are, however, biased against the two ends of the sequence, which implies that the X-ray Seyfert galaxies present a population at a middle evolutionary stage.

79 ASTRONOMY AND ASTROPHYSICS↗