Amorphous, Corrosion-Resistant Coatings for Storage Canister
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Components of water treatment plants (WTPs) are susceptible to corrosion from constant immersion in water. A case history of corrosion and proximity to chlorine problems and their treatment at an Army WTP is presented. Solutions included using high micro-silica restoration mortar and advanced coal tar epoxy coatings.
A large clearance TiO{sub 2} nanotube arrays (LTAs) has been synthesized by a not more than 12 h anodization duration and based on this a branched TiO{sub 2} nanotube arrays (BLTs) has been achieved through TiO{sub 2} nanorods branch-like grown on the LTAs. Some key factors and probable mechanisms of the fabrication processes on two novel nanoarchitectures are discussed. Exhilaratingly, it is found that the obtained LTAs has demonstrated large pore diameter and void spaces (pore diameter {approx}350 nm; void spaces {approx}160 nm; and tube length {approx}3.5 {mu}m), and the synthesized hierarchical BLTs, compared with conventional TiO{sub 2} nanotube arrays, has shown a much stronger dye absorption performance and an approximately double of the solar cell efficiency (in our case from 1.62% to 3.18% under simulated AM 1.5 conditions). - Graphical Abstract: The schematic diagram of synthesis process for LTAs and BLTs is on the above and the corresponding FESEM images of obtained photoanodes samples are shown below. Highlights: > Large clearance TiO{sub 2} nanotube arrays (LTAs) was synthesized by a fast anodization process of 12 h. > Anodization time of 12 h is just 10% of about 120 h reported in the previous references. > Branch-like TiO{sub 2} nanotube arrays (BLTs) was achieved by growing TiO{sub 2} nanorods on the LTAs. > Obtained BLTs and LTAs show impressive morphology and noticeable improvement of surface area. > BLTs shows about more than 1 times higher solar cell efficiency than that of TiO{sub 2} nanotube arrays.
TiO{sub 2} photoelectrodes with various nanostructures have been successfully prepared by the anodization method. The morphology, microstructure and optical properties of as-prepared photoelectrodes were studied by scanning electron microscopy (SEM), X-ray diffraction (XRD), ultraviolet/visible light diffuse reflectance spectra (UV/vis/DRS), surface photovoltage spectroscopy (SPS) and photocurrent. The electronic structure and optical properties of La doped/undoped TiO{sub 2} photoelectrodes with different crystal structures were calculated by the density function theory. The photocatalytic and photoelectrocatalytic activities of as-prepared photoelectrodes were evaluated. The results showed that the anodization potentials played a crucial role in the surface morphology and microstructure. Both results of theoretical calculations and experimental tests demonstrated that La-doped photoelectrodes were more sensitive to light than undoped one. The difference of photoelectrodes performance was ascribed to the crystal configuration, impurity energy levels and long-range orientation moving of photogenerated carriers. - Graphical abstract: Photophysical chemistry processes in as-prepared TiO{sub 2} photoelectrodes. Overall scheme of TiO{sub 2} photoelectrodes: (A) movement of photoelectrons and holes without bias potentials; (B) movement of photoelectrons and holes at applied bias potentials; (a) and (b) were the transmission of photogenerated electrons and holes of local enlargement of (A) (black open circle): (a) photoelectrons movement in P-TiO{sub 2} photoelectrodes and La-TiO{sub 2} photoelectrodes, the red dot line denotes the top of valence band (VB) and the bottom of conduction band (CB) of pure photoelectrodes; (b) photoelectrons movement in P-160 and La-160 TiO{sub 2} photoelectrodes (mixed crystal phase). The number refers to as follows: (1) transmission process of photoelectrons and holes; (2) recombination process of photoelectrons and holes. Arrows represent the moving direction of photoelectrons. Highlights: Black-Right-Pointing-Pointer Morphology and structure of La-doped photoelectrodes. Black-Right-Pointing-Pointer Band gap and electric structure of La-doped and undoped photoelectrodes. Black-Right-Pointing-Pointer Optical, PECH, PC and PEC properties of La-TiO{sub 2} photoelectrodes. Black-Right-Pointing-Pointer Transmission process of photoelectron-hole pairs in La-TiO{sub 2} photoelectrodes.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A new phosphate-free pretreatment from Henkel Corp. named TecTalis , was investigated. The treatment bath is composed of dilute hexafluorozirconic acid with small quantities of non-hazardous components containing Si and Cu. The performance of treated steel was compared to samples treated in a phosphate conversion coating bath, in simple hexafluorozirconic acid and in TecTalis without the addition of the Cu containing component. Atomic Force Microscopy (AFM) and Transmission Electron Microscopy (TEM) were used to characterize the coating surface morphology, structure and composition. A Quartz Crystal Microbalance (QCM) was used for studying film growth kinetics on thin films of pure Fe, Al and Zn. Electrochemical Impedance Spectroscopy (EIS) was performed on treated and painted steel for studying long-term corrosion performance of the coatings. The phosphate-free coating provided long-term corrosion performance comparable to that of phosphate conversion coatings. The coatings uniformly cover the surface in the form of 10-20 nm sized nodules and clusters of these features up to 500 nm in size. The coatings are usually about 20-30 nm thick and are mostly composed of Zr and O with enrichment of copper at randomly distributed locations and clusters.
Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where they are needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into the microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy.
Corrosion is a destructive process that often causes failure in metallic components and structures. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to control it. The multi-functionality of the coating is based on micro-encapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of other existing microcapsules designs, the corrosion controlled release function that allows the delivery of corrosion indicators and inhibitors on demand only when and where needed. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection efficacy. This
Borobond is a company-proprietary material developed by the CRADA partner in collaboration with Argonne, and is based on Argonne's Ceramicrete technology. It is being used by DOE for nuclear materials safe storage, and Boron Products, LLC is the manufacturer and supplier of Borobond. The major objective of this project was to produce a more versatile composition of this material and find new applications. Major target applications were use for nuclear radiation shields, such as in dry storage casks; use in immobilization of most difficult waste streams, such as Hanford K-Basin waste; use for soluble and volatile fission products, such as Cs, Tc, Sr, and I; and use for corrosion and fire protection applications in nuclear facilities.
Encapsulant materials used in PV modules serve multiple purposes. They physically hold components in place, provide electrical insulation, optically couple superstrate materials (e.g., glass) to PV cells, protect components from mechanical stress by mechanically de-coupling components via strain relief, and protect materials from corrosion. To do this, encapsulants must adhere well to all surfaces, remain compliant, and transmit light after exposure to temperature, humidity, and UV radiation histories. Encapsulant materials by themselves do not completely prevent water vapour ingress [1-3], but if they are well adhered, they will prevent the accumulation of liquid water providing protection against corrosion as well as electrical shock. Here, a brief review of some of the polymeric materials under consideration for PV applications is provided, with an explanation of some of their advantages and disadvantages.
This overview of oxidation and corrosion effects on silica-protected ceramics and composites is divided into two parts: (1) External effects and (2) Internal effects. In regard to the first part, the literature indicates silica the best of the common protective oxides in pure oxygen. However in actual applications, there are four major degradation routes which must be considered: (1) Formation of SiO(g); (2) water vapor enhancement of oxidation rate of Si(OH)4 volatiles; (3) low level metal cation enhancement of oxidation rate; and (4) molten salt and slag corrosion. Several protective coating concepts have been discussed, which may minimize these effects. Internal effects deal with a microcrack providing a path for oxygen ingress to the oxygen sensitive fiber and fiber coating. This is a critical area of study for theses materials. Possible solutions involve a fluid glass to fill the cracks and/or oxygen getting along the walls of the crack.
Combinations of borates, nitrates, phosphates, silicates, and sodium MBT protect aluminum from corrosion in fresh water. Most effective combinations contained sodium phosphate and were alkaline. These inhibitors replace toxic chromates which are subject to governmental restrictions, but must be used in larger quantities. Experimental exposure times varied from 1 to 14 months depending upon nature of submersion solution.
Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it. The multi-functionality of the coating is based on microencapsulation technology specifically designed for corrosion control applications. This design has, in addition to all the advantages of existing microcapsulation designs, the corrosion controlled release function that triggers the delivery of corrosion indicators and inhibitors on demand, only when and where needed. Microencapsulation of self-healing agents for autonomous repair of mechanical damage to the coating is also being pursued. Corrosion indicators, corrosion inhibitors, as well as self-healing agents, have been encapsulated and dispersed into several paint systems to test the corrosion detection, inhibition, and self-healing properties of the coating. Key words: Corrosion, coating, autonomous corrosion control, corrosion indication, corrosion inhibition, self-healing coating, smart coating, multifunctional coating, microencapsulation.
Samples of Hanford Nuclear Reservation (HNR) tank waste and simulated Hanford tank waste were exposed to carbon dioxide gas (CO{sub 2}) in the laboratory in order to decrease the pH of the solution. Sodium hydroxide is required to be added to some tanks according to waste handling specifications to keep tanks protected from pitting corrosion, but the maximum-allowed volume in some tanks is currently approaching capacity. Decreasing the pH of tank solutions using CO{sub 2} gas mimics the environmental exposure chemistry, does not add sodium, and allows for testing on solutions currently categorized as out-of-specification according to technical waste handling documents. Legacy alloy A537 Class 1 carbon steel was used to construct the AN tanks on the HNR and was utilized for this testing. The planned testing of three solutions included a simulant for feasibility and a waste solution from Tank 241-AN-102 (AN-102), taken in 2013, which was run in duplicate. The solutions were evaluated for corrosion potential using cyclic potentiodynamic polarization (CPP) scans to determine the propensity for stress corrosion cracking and pitting corrosion. Results in all solutions showed that pitting potential was low when the pH was above 11 and temperatures were below 40 deg. C. As solution pHs dipped into the 10- 10.5 range, there were mixed results. CPP scans were initially run at the higher temperature of 50 deg. C, accelerating corrosion rates. Solution pHs that did not indicate corrosion were further exposed to CO{sub 2}. Solutions with mixed or positive pitting results were rerun at 40 deg. C. The first failed run on the tank solution was seen when testing the duplicate sample at 50 deg. C and a pH of 13.01. When this solution was retested at 40 deg. C, the CPP scan did not show corrosion. A mixed corrosion result was obtained from a scan run at the final pH of 10 when tested at 50 deg. C. Upon completion of testing a visual inspection of the coupon did not show corrosion products on its surface. These results provide assurance that tanks containing slightly reduced pHs are still protected from pitting corrosion. Tank integrity assurance at a lower pH limit in Tank AN-102 could slow sodium addition and the rising volume of hazardous waste. Other benefits of reducing the pH specification would be reduced costs associated with retrieving and storing smaller volumes of hazardous waste, a reduced number of radiation exposure events (required for pH modification of tank waste), and a potential for a decreased volume required to be immobilized for long-term storage in a vitrified (glass) phase. (authors)
The underground architecture and layout of the proposed Belgian high-level (HLW) and long-lived, intermediate-level radioactive wastes (ILW-LL) disposal system (repository) is mainly based on lessons learned during the development and 30-year-long operation of an underground research laboratory (URL) ('HADES') located adjacent to the city of Mol at a depth of 225 m in a 100-m-thick, Tertiary clay formation; the Boom clay. The following main operational and safety challenges are addressed in the proposed architecture and layout: 1. Following excavation, the underground openings needed to be promptly supported to minimize the extent of the excavation damaged zone (EDZ). 2. The size and unsupported stand-up time at tunnel crossings/intersections also needed to be minimized to minimize the extent of the related EDZ. 3. Steel components had to be minimized to limit the related long-term (post-closure) corrosion and hydrogen production. 4. The shafts and all equipment had to go down through a 180-m-thick aquifer and handle up to 65-Ton payloads. 5. The shaft seals had to be placed in the underlying clay layer. The currently proposed layout minimizes the excavated volume based on strict long-term-safety criteria and optimizes operational safety. Operational safety is further enhanced by a remote-controlled waste-package-handling system transporting the waste packages from their respective surface location down to their respective disposal location with no intermediate operation. The related on-site preparation and thenceforth use of cement-based, waste package- transportation containers are integral operational-safety components. In addition to strengthening the waste packages and providing radiation protection, these containers also provide long-term corrosion protection of the internal 'primary' steel packages. (authors)
Corrosion of reinforcing steel in concrete is an insidious problem for structures at Kennedy Space Center (KSC). KSC is located on the coast of Florida in a highly corrosive atmosphere. Launch pads, highway bridge infrastructure, and buildings are strongly affected. To mitigate these problems, NASA initiated a development program for a Galvanic Liquid-Applied Coating System (GLACS). A breakthrough in this area would have great commercial value in transportation, marine and construction industry infrastructures. The patented NASA GLACS system has undergone considerable testing to meet the needs of commercialization. A moisture-cure coating gives excellent adhesion with ease of application compared to existing galvanic products on the market. The latest development, GalvaCori; can be sprayed or hand applied to almost any structure shape. A self-adhesive conductive tape system has been devised to simplify current collection within the coating areas. In testing programs, millivolt potential and milliamp output per square foot of anode have been closely studied at actual test sites. These two parameters are probably the most challenging items of a resin-based, room-temperature-applied, galvanic coating. Extensive re-formulation has resulted in a system that provides the needed polarization for catholic protection of reinforcing steel in concrete in a variety of structure environments. The rate of corrosion of rebar in concrete is greatly affected by the environment of the structure. In addition to this, for any given concrete structure; moisture level, carbonization, and chloride contamination influences the rate of rebar corrosion. Similarly, the cathodic protection level of galvanic systems is also dependent on the moisture level of the concrete. GalvaCorr is formulated to maintain galvanic activity as the moisture level of the structure declines. GalvaCorr is available as a three-part kit. The mixing step requires about ten minutes. The viscosity can be easily adjusted to meet the application needs. The pot or working life is four to six hours, depending on the temperature. GalvaCorr can be thought of as a spray-on coating, battery ready to provide up to -1.4 volts (relative to CSE) of cathodic protection (CP) potential.
In this study, an alkyd/Al{sub 2}O{sub 3} nanocomposite coating was prepared and applied on a stainless steel substrate. The Al{sub 2}O{sub 3} nanoparticles (NPs) with different weight ratios (1, 2, and 3 wt.%) were added to the alkyd resin and coated on the substrate via dip-coating technique. Then, the dispersion of NPs in the coating film was investigated using scanning electron microscopy (SEM) and scanning probe microscopy (SPM). The coating thickness estimated by SEM was 20 μm. The corrosion behavior of the coating was examined through the Tafel polarization and salt spray tests. The results showed that the addition of Al{sub 2}O{sub 3} NPs up to 2 wt.% will result in a dense and homogeneous coating which protects the substrate leading to lower corrosion current density from 9.2 × 10{sup −6} to 1.65×10{sup −9} A/cm{sup 2} compared with the uncoated stainless steel.