Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Degradation of TBC Systems in Environments Relevant to Advanced Gas Turbines for IGCC Systems

Air plasma sprayed (APS) thermal barrier coatings (TBCs) are used to provide thermal insulation for the hottest components in gas turbines. Zirconia stabilized with 7wt% yttria (7YSZ) is the most common ceramic top coat used for turbine blades. The 7YSZ coating can be degraded from the buildup of fly-ash deposits created in the power-generation process. Fly ash from an integrated gasification combined cycle (IGCC) system can result from coal-based syngas. TBCs are also exposed to harsh gas environments containing CO 2 , SO 2 , and steam. Degradation from the combined effects of fly ash and harsh gas atmospheres has the potential to severely limit TBC lifetimes. The main objective of this study was to use lab-scale testing to systematically elucidate the interplay between prototypical deposit chemistries (i.e., ash and its constituents, K 2 SO 4 , and FeS) and environmental oxidants (i.e., O 2 , H 2 O and CO 2 ) on the degradation behavior of advanced TBC systems. Several mechanisms of early TBC failure were identified, as were the specific fly-ash constituents responsible for degradation. The reactivity of MCrAlY bondcoats used in TBC systems was also investigated. The specific roles of oxide and sulfate components were assessed, together with the complex interplay between gas composition, deposit chemistry and alloy reactivity. Bondcoat composition design strategies to mitigate corrosion were established, particularly with regard to controlling phase constitution and the amount of reactive elements the bondcoat contains in order to achieve optimal corrosion resistance.

01 COAL, LIGNITE, AND PEAT↗

Final Scientific/Technical Report for DOE/EERE project Advanced Magnetic Refrigerant Materials

A team led by GE Global Research developed new magnetic refrigerant materials needed to enhance the commercialization potential of residential appliances such as refrigerators and air conditioners based on the magnetocaloric effect (a nonvapor compression cooling cycle). The new magnetic refrigerant materials have potentially better performance at lower cost than existing materials, increasing technology readiness level. The performance target of the new magnetocaloric material was to reduce the magnetic field needed to achieve 4 °C adiabatic temperature change (ΔT adiabatic ) from 1.5 Tesla to 0.75 Tesla. Such a reduction in field minimizes the cost of the magnet assembly needed for a magnetic refrigerator. Such a reduction in magnet assembly cost is crucial to achieving commercialization of magnetic refrigerator technology. This project was organized as an iterative alloy development effort with a parallel material modeling task being performed at George Washington University. Four families of novel magnetocaloric alloys were identified, screened, and assessed for their performance potential in a magnetic refrigeration cycle. Compositions from three of the alloy families were manufactured into regenerator components. At the beginning of the project a previously studied magnetocaloric alloy was selected for manufacturing into the first regenerator component. Each of the regenerators was tested in magnetic refrigerator prototypes at a subcontractor at at GE Appliances. The property targets for operating temperature range, operating temperature control, magnetic field sensitivity, and corrosion resistance were met. The targets for adiabatic temperature change (ΔT adiabatic ) and thermal hysteresis were not met. The high thermal hysteresis also prevented the regenerator components from displaying measurable cooling power when tested in prototype magnetic refrigerators. Magnetic refrigerant alloy compositions that were predicted to have low hysteresis were not attainable with conventional alloy processing methods. Preliminary experiments with rapid solidification methods showed a path towards attaining low hysteresis compositions should this alloy development effort be continued.

36 MATERIALS SCIENCE↗

The helical screw expander evaluation project

A positive-displacement helical-screw expander of the Lysholm type has been adapted for geothermal service and successfully demonstrated in a 50 kW prototype power system. Evaluation of the expander by tests of a new model in a 1 MW power system under wellhead conditions in selected liquid-dominated geothermal fields is proposed. The objectives are to determine the performance characteristics of the expander and power system over a broad range of operating conditions and also to examine the concept of wellhead power plants. Throttling and fractionation of the fluids from the test wells is planned to simulate a wide range of wellhead pressures and steam fractions. Variation in the expander exhaust pressure is also planned. The investigation will include expander efficiency, corrosion, erosion, scale formation and control, and endurance testing. Interaction studies with the wells and an electric grid are also proposed.

Mckay, R. A.↗

Red Plague Control Plan (RPCP)

SCOPE: Prescribes the minimum requirements for the control of cuprous / cupric oxide corrosion (a.k.a. Red Plague) of silver-coated copper wire, cable, and harness assemblies. PURPOSE: Targeted for applications where exposure to assembly processes, environmental conditions, and contamination may promote the development of cuprous / cupric oxide corrosion (a.k.a. Red Plague) in silver-coated copper wire, cable, and harness assemblies. Does not exclude any alternate or contractor-proprietary documents or processes that meet or exceed the baseline of requirements established by this document. Use of alternate or contractor-proprietary documents or processes shall require review and prior approval of the procuring NASA activity.

Cooke, Robert W.↗

Progress on Resolution of Technical Issues at the Hanford Waste Treatment And Immobilization Plant Project - 16285

The U.S. Department of Energy's (DOE) Waste Treatment and Immobilization Plant (WTP) Pretreatment (PT) Facility has a number of first-of-a-kind technical challenges that have required additional expert analysis and testing activities to resolve. In 2006 an External Flowsheet Review Team identified 28 technical vulnerabilities with the plant design or future operability. Over a period of three months starting in September 2012, a number of top scientists and engineers conducted a review of the major technical issues associated with the design and operability of the WTP. These experts also provided independent advice on some of the broader challenges associated with completing the Hanford tank waste mission - highlighting the linkage between the physical and chemical properties of the tank waste and the PT Facility technical issues. In 2012 and early 2013 DOE's Office of River Protection (ORP) directed the WTP contractor to suspend production work on the Pretreatment Facility until the outstanding technical issues could be resolved and the nuclear safety basis could be updated and brought into alignment with any updates to the facility design and/or process flowsheet. Specific plans for resolving each the technical issues have been developed and significant progress has been made over the past year in identifying solution sets for each of the issues. The eight remaining technical issues (referred to as T1 to T8) are as follows: (T1) Hydrogen Gas Release from Vessel Solids; (T2) Potential Criticality in Pretreatment Facility Vessels; (T3) Hydrogen in Piping and Ancillary Vessels; (T4) Pulse-Jet Mixing and Control; (T5) Erosion and Localized Corrosion in WTP Vessels and Piping; (T6) Design Redundancy in Black Cells/In-Service Inspection; (T7) Black Cell Vessel Structural Integrity; (T8) Facility Ventilation. This paper provides a synopsis of the progress that has been made on resolving the Pretreatment technical issues over the past year, and how resolution of the issues will enable DOE to make an informed decision to resume design and production engineering for the Pretreatment Facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing and Implementing New Waste Chemistry Controls for Hanford's Double-Shell Tanks - 20041

Waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the Savannah River Site (SRS). The controls were established based on a combination of SRS chemistry limits and corrosion testing results. Conditions in the Hanford DSTs have changed over time, with the temperature in the majority of the DSTs dropping below 50 deg. C. Testing indicated that the original chemistry control specification and SCC testing performed in 2010 did not protect against pitting corrosion mechanisms - what is believed to have caused the failure of tank 241-AY-102. New waste chemistry controls are necessary to protect the DSTs from both SCC and pitting corrosion. Savannah River National Laboratory (SRNL), with input from the Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG), performed a statistically based investigation of nitrate and halide ion induced pitting corrosion. The investigation was intended to develop a comprehensive waste chemistry envelope that minimizes the risk of both SCC and pitting caused by halide and nitrate ions. The waste chemistry envelope needed to be robust enough to address future waste retrieval and process changes which could significantly change the waste composition of the DSTs. The experimental design allowed the statistically significant ions and their effect on pitting corrosion to be determined. SRNL developed the 'pitting factor' which is an empirical relationship between the statistically significant inhibitive species (hydroxide, and nitrite), and pitting inducing species (nitrate, chloride, and fluoride). The coefficients are weighted factors that show the degree of influence the species have on the propensity for pitting. New waste chemistry control limits were recommended by SRNL, and concurred with by the TIEP CSG, that incorporated the pitting factor along with other limits. The controls developed to reduce the risk of pitting corrosion were evaluated to determine if they also protected against SCC. Hundreds of test results were reviewed and compared against the proposed limits. With the exception of one test result, instances where cracking was observed corresponded to chemistry that was outside of the proposed limits - indicating that the chemistry controls developed for pitting also adequately addressed SCC concerns. Existing tank composition estimates were evaluated against the new chemistry controls - three current tank chemistries are suspect, and may not meet the new chemistry control requirements. These included the interstitial liquid (liquid associated with solids) of DSTs 241-AN-102, 241-AN-106, 241-AN-107, and 241-AY-101. Measures are ongoing to evaluate the tanks with the suspect chemistry. These include varying combinations of: performing additional evaluations (history of use, modeling); DST specific laboratory testing; and, pursuing core samples of the DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Viability of Cathodic Protection for Preventing Corrosion of Stainless Steel 316H in Molten LiF-NaF-KF

Molten fluoride salts are candidate heat transfer fluids in a number of applications such as generation IV molten salt nuclear reactors and concentrated solar power plants. However, a chief concern in the design of these systems is the corrosion of structural materials that come in contact with these molten salts. Redox control methods such as the purification of salt, the addition of active elements, and applied electrochemical potential can be efficient methods for preventing the corrosion of structural materials in molten fluoride salts. Applied electrochemical potential as a redox control method for application in molten fluoride salts has rarely been explored. This study seeks to understand the viability of impressed current cathodic protection (CP) at various currents as a redox control method to prevent corrosion of stainless steel 316H in molten LiF-NaF-KF (FLiNaK) salt. Results show that application of CP can be an effective method to prevent corrosion of SS316H in molten FLiNaK salt, but the applied current will have to be optimized to prevent undesirable side effects such as reduction of salt constituents, salt deposition on electrodes, etc.

Materials Science↗

Determining the Efficiency of Nitrogen Blanketing to Mitigate Corrosion in Hanford’s Transfer Line System

The Hanford site stores large quantities of radioactive waste in underground, carbon-steel, double-shell tanks. The waste is transferred between the tanks using piping that consists of carbon-steel pipes and carbon-steel encasements. The transfer lines have shown extensive corrosion on both the interior of the casing and exterior of the carrier pipes. Nitrogen blanketing, used to displace the oxygen in the transfer lines, was hypothesized to reduce the corrosion of the transfer lines. Experimental studies were conducted to investigate the effect of oxygen concentration on the corrosion rate and the initiation of pitting on carbon steel. The results indicated that controlling the oxygen concentration to 0% effectively mitigates corrosion. However, at 5 vol% oxygen, a significant increase in the general corrosion rate and pitting corrosion is observed.

Atmospheric Corrosion↗

Field Testing of High Current Electrokinetic Nanoparticle Treatment for Corrosion Mitigation in Reinforced Concrete

Electrokinetic Nanoparticle (EN) treatment was used as a rapid repair measure to mitigate chloride induced corrosion of reinforced concrete in the field. EN treatment uses an electric field to transport positively charged nanoparticles to the reinforcement through the concrete capillary pores. Cylindrical reinforced concrete specimens were batched with 4.5 wt % salt content (based on cement mass). Three distinct electrokinetic treatments were conducted using high current density (up to 5 A/m2) to form a chloride penetration barrier that was established in 5 days, as opposed to the traditional 6-8 weeks, generally required for electrochemical chloride extraction (ECE). These treatments included basic EN treatment, EN with additional calcium treatment, and basic ECE treatment. Field exposures were conducted at the NASA Beachside Corrosion Test Site, Kennedy Space Center, Florida, USA. The specimens were subjected to sea water immersion at the test site as a posttreatment exposure. Following a 30-day post-treatment exposure period, the specimens were subjected to indirect tensile testing to evaluate treatment impact. The EN treated specimens exhibited 60% and 30% increases in tensile strength as compared to the untreated controls and ECE treated specimens respectively. The surfaces of the reinforcement bars of the control specimens were 67% covered by corrosion products. In contrast, the EN treated specimens exhibited corrosion coverage of only 4%. Scanning electron microscopy (SEM) revealed a dense concrete microstructure adjacent to the bars of the treated specimens as compared to the control and ECE specimens. Energy dispersive spectroscopic (EDS) analysis of the polished EN treated specimens showed a reduction in chloride content by a factor of 20 adjacent to the bars. This study demonstrated that EN treatment was successful in forming a chloride penetration barrier rapidly. This work also showed that the chloride barrier was effective when samples were exposed to field conditions at one of the most severely corrosive environments in North America.

Cardenas, Henry↗

Slow Strain Rate Testing of A537 Tank Wall Material

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and the addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. This testing program was designed to examine the risk of SCC associated with utilizing the pitting factor (PF) and nitrite/nitrate (NO 2 - /NO 3 - ) ratio limits for handling dissolved salt solutions at an elevated temperature in the carbon steel waste tanks. The previously identified limits are a PF of 1.2 and an NO 2 - /NO 3 - ratio of 0.15. The results indicate that as long as the NO 2 - /NO 3 - ratio exceeds 0.1 and the PF is above approximately 0.8, there is a discernible safety margin between the open circuit potential (OCP) and the critical cracking potential (CCP) observed during applied potential testing. However, this margin, defined by the difference between the OCP and CCP, is relatively narrow, ranging from 0.1 to 0.25 volts. This small margin raises concerns about potential shifts in OCP during waste retrieval operations, which could inadvertently increase the risk of SCC if the OCP approaches or exceeds the CCP. These results confirm that dissolved salt solutions provide a potent chemistry that, under certain conditions, makes carbon steel susceptible to SCC. The next question to consider is the influence these results have on decisions for storage and retrieval of waste from the tanks. For Type III/IIIA waste tanks, the risk of SCC remains very low. First, and most importantly, the post-weld stress relief of the tanks has reduced the residual stress near the welds. Thus, without the stress component, SCC risk is minimized. The material of construction (A537 Carbon steel) for the Type III/IIIA tanks is superior to the steel in its resistance to SCC than the steel that was utilized for the Type I, II, and IV tanks (A285 carbon steel). From a chemistry control standpoint for a Type III/IIIA tank directly involved with handling dissolved salt solutions, the PF and NO 2 - /NO 3 - ratio limits may be utilized wherein chemistry control provides an extra layer of defense against SCC. Chemistry control for a Type III/IIIA tank minimizes the risk for a tank that may receive the dissolved salt solution, particularly if that tank is a Type I, II, or IV waste tank. On the other hand, if the dissolved salt solution is handled by a Type I, II, or IV waste tank the risk of SCC is real. The potent chemistry, absence of stress relief, and inferior material result in a condition that is conducive to cracking. Efforts should be made to either avoid transferring waste that may not meet the PF and NO 2 - /NO 3 - ratio criteria to one of these tanks or if it is unavoidable, take measures to minimize the consequences of a leak. As shown by these tests, even if the PF and NO 2 - /NO 3 - ratio criteria are met, there is a risk that the tank potential may be disturbed in the positive direction and the risk of SCC increase.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Testing Proposal -1: Assessment of the Corrosion of Stainless Steel Subjected to an Aqueous Solution of Hydrochloric Acid

This corrosion-test proposal outlines the methods to promote rapid pitting corrosion on various pitting resistant stainless steels under controlled conditions. This study can be performed in-whole or in- part as the Corrosion Working Group (CWG) leadership of the Los Alamos National Laboratory (LANL) deems pertinent. This proposal is in response to CWG’s need to understand the mechanisms and the possible detrimental failure of the 316L SAVY (an acronym that represents the first initial of the four co-developers, Stone, Anderson, Veirs, Yarbro) 4000 container design currently in service. This detrimental failure evolved from a question that the CWG arrived to by consensus as “What is the critical pit depth that would comprise the design wall-strength of the SAVY-4000?”

36 MATERIALS SCIENCE↗

Corrosion detector apparatus for universal assessment of pollution in data centers

A compact corrosion measurement apparatus and system includes an air fan, a corrosion sensor, a temperature sensor, a humidity sensor, a heater element, and an air flow sensor all under control to monitor and maintain constant air parameters in an environment and minimize environmental fluctuations around the corrosion sensor to overcome the variation commonly encountered in corrosion rate measurement. The corrosion measurement apparatus includes a structure providing an enclosure within which are located the sensors. Constant air flow and temperature is maintained within the enclosure where the corrosion sensor is located by integrating a variable speed air fan and a heater with the corresponding feedback loop control. Temperature and air flow control loops ensure that corrosivity is measured under similar conditions in different facilities offering a general reference point that allow a one to one comparison between facilities with similar or different pollution levels.

47 OTHER INSTRUMENTATION↗

An Unsteady State Gas Transport Model in Matrix Laboratory (MATLAB) for PWR Gas Management

Reactor Coolant System (RCS) hydrogen gas management can be a challenge at Pressurized Water Reactors (PWRs) during shutdown, startup, and steady state operation. Poor hydrogen control can result in higher general corrosion rates for RCS components and increases in critical path time for shutdown or startup. Also, performance indicator penalties may be accrued by entry into Electric Power Research Institute (EPRI) Action Level conditions or by accrual of Chemistry Effectiveness Index (CEI) penalties established by the Institute of Nuclear Power Operations (INPO). Furthermore, poor hydrogen control may increase industrial safety risk due to the creation of an explosive environment. Part of the hydrogen management difficulty arises from the interaction of several phenomena that require complex simulations to fully understand. While hydrogen gas transport models have been developed, the application of these models is limited by the computational intensity required to accurately model the dynamism inherent in plant shutdown or startup. Subsequently, a gas transport model is developed in a suitable computational program to meet these needs and provide input to an optimized RCS hydrogen management strategy for all operational modes. The gas transport model is used to model RCS hydrogen behavior for an example PWR during an End of Cycle (EOC) Forced Outage (FO) startup, a refueling outage (RFO) shutdown, and during nominal steady state operation. The computational software selected is Matrix Laboratory (MATLAB{sup R})

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Applications in the Nuclear Industry for Thermal Spray Amorphous Metal and Ceramic Coatings

Amorphous metal and ceramic thermal spray coatings have been developed that can be used to enhance the corrosion resistance of containers for the transportation, aging and disposal of spent nuclear fuel and high-level radioactive wastes. Iron-based amorphous metal formulations with chromium, molybdenum and tungsten have shown the corrosion resistance believed to be necessary for such applications. Rare earth additions enable very low critical cooling rates to be achieved. The boron content of these materials, and their stability at high neutron doses, enable them to serve as high efficiency neutron absorbers for criticality control. Ceramic coatings may provide even greater corrosion resistance for container applications, though the boron-containing amorphous metals are still favored for criticality control applications. These amorphous metal and ceramic materials have been produced as gas atomized powders and applied as near full density, non-porous coatings with the high-velocity oxy-fuel process. This paper summarizes the performance of these coatings as corrosion-resistant barriers, and as neutron absorbers. Relevant corrosion models are also discussed, as well as a cost model to quantify the economic benefits possible with these new materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ACCELERATED TESTING OF NEUTRON-ABSORBING ALLOYS FOR NUCLEAR CRITICALITY CONTROL

The US Department of Energy requires nuclear criticality control materials be used for storage of highly enriched spent nuclear fuel used in government programs and the storage of commercial spent nuclear fuel at the proposed High-Level Nuclear Waste Geological Repository located at Yucca Mountain, Nevada. Two different metallic alloys (Ni-Cr-Mo-Gd and borated stainless steel) have been chosen for this service. An accelerated corrosion test program to validate these materials for this application is described and a performance comparison is made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical research and advanced technology (CRT) support project

A critical technology base for utility and industrial gas turbines by planning the use of coal-derived fuels was studied. Development tasks were included in the following areas: (1) Combustion - investigate the combustion of coal-derived fuels and methods to minimize the conversion of fuel-bound nitrogen to NOx; (2) materials - understand and minimize hot corrosion; (3) system studies - integrate and focus the technological efforts. A literature survey of coal-derived fuels was completed and a NOx emissions model was developed. Flametube tests of a two-stage (rich-lean) combustor defined optimum equivalence ratios for minimizing NOx emissions. Sector combustor tests demonstrated variable air control to optimize equivalence ratios over a wide load range and steam cooling of the primary zone liner. The catalytic combustion of coal-derived fuels was demonstrated. The combustion of coal-derived gases is very promising. A hot-corrosion life prediction model was formulated and verified with laboratory testing of doped fuels. Fuel additives to control sulfur corrosion were studied. The intermittent application of barium proved effective. Advanced thermal barrier coatings were developed and tested. Coating failure modes were identified and new material formulations and fabrication parameters were specified. System studies in support of the thermal barrier coating development were accomplished.

Furman, E. R.↗

Wear of iron and nickel in corrosive liquid environments

Friction and wear behavior of Fe and Ni sliding on aluminum oxide in aerated sulfuric acid and hydrochloric acid were investigated. The results show that the concentration of acid is an important factor in controlling the metal loss caused by wear corrosion processes in the acids. At very dilute acid concentration (10 to the -4 N), Fe behaves differently from Ni. Fe develops a soft, friable deposit, while Ni develops no corrosion layer. The formation and removal of the corrosion deposit on Fe resulted in high metal loss and coefficient of friction, as compared to the relatively low metal loss and coefficient of friction observed for Ni. At slightly higher acid concentration (10 to the -3 and 10 to the -2 N), no corrosion products were produced on both Fe and Ni. Wear of Fe and Ni was generally at a minimum. At higher acid concentration (10 to the -1 N and above), loss of Fe and Ni increased as the acid concentration increased. In sulfuric acid the maximum loss of both Fe and Ni was at 7.5 N (30%) concentration, and the metal losses of both Fe and Ni dropped markedly at 15 N (50%) and above. In hydrochloric acid, however, the Fe loss continued to increase with the increase of acid concentration, and the maximum Fe loss occurred in the most concentrated acid (12.1 N, 37%). There were variations in loss with Ni from specimen to specimen examined in hydrochloric acids (10 to the -1 N and above). The coefficient of friction for Ni increased slightly with an increase in acid concentration up to 10 to the -2 N. When corrosion started to dominate in the wear-corrosion process, the coefficient of friction decreased in both sulfuric and hydrochloric acids at 10 to the -1 N and above.

Miyoshi, Kazuhisa↗

Wear of iron and nickel in corrosive liquid environments

Friction and wear behavior of Fe and Ni sliding on aluminum oxide in aerated sulfuric acid and hydrochloric acid were investigated. The results show that the concentration of acid is an important factor in controlling the metal loss caused by wear corrosion processes in the acids. At very dilute acid concentration (10 to the -4 N), Fe behaves differently from Ni. Fe develops a soft, friable deposit, while Ni develops no corrosion layer. The formation and removal of the corrosion deposit on Fe resulted in high metal loss and coefficient of friction, as compared to the relatively low metal loss and coefficient of friction observed for Ni. At slightly higher acid concentration (10 to the -3 and 10 to the -2 N), no corrosion products were produced on both Fe and Ni. Wear of Fe and Ni was generally at a minimum. At higher acid concentration (10 to the -1 N and above), loss of Fe and Ni increased as the acid concentration increased. In sulfuric acid the maximum loss of both Fe and Ni was at 7.5 N (30 percent) concentration, and the metal losses of both Fe and Ni dropped markedly at 15 N (50 percent) and above. In hydrochloric acid, however, the Fe loss continued to increase with the increase of acid concentration, and the maximum Fe loss occurred in the most concentrated acid (12.1 N, 37 percent). There were variations in loss with Ni from specimen to specimen examined in hydrochloric acids (10 to the -1 N and above). The coefficient of friction for Ni increased slightly with an increase in acid concentration up to 10 to the -2 N. When corrosion started to dominate in the wear-corrosion process, the coefficient of friction decreased in both sulfuric and hydrochloric acids at 10 to the -1 N and above.

Miyoshi, Kazuhisa↗