Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAINER SAMPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Neotropical termite microbiomes as sources of novel plant cell wall degrading enzymes

In this study, we used shotgun metagenomic sequencing to characterise the microbial metabolic potential for lignocellulose transformation in the gut of two colonies of Argentine higher termite species with different feeding habits, Cortaritermes fulviceps and Nasutitermes aquilinus. Our goal was to assess the microbial community compositions and metabolic capacity, and to identify genes involved in lignocellulose degradation. Individuals from both termite species contained the same five dominant bacterial phyla (Spirochaetes, Firmicutes, Proteobacteria, Fibrobacteres and Bacteroidetes) although with different relative abundances. However, detected functional capacity varied, with C. fulviceps (a grass-wood-feeder) gut microbiome samples containing more genes related to amino acid metabolism, whereas N. aquilinus (a wood-feeder) gut microbiome samples were enriched in genes involved in carbohydrate metabolism and cellulose degradation. The C. fulviceps gut microbiome was enriched specifically in genes coding for debranching- and oligosaccharide-degrading enzymes. These findings suggest an association between the primary food source and the predicted categories of the enzymes present in the gut microbiomes of each species. To further investigate the termite microbiomes as sources of biotechnologically relevant glycosyl hydrolases, a putative GH10 endo-β-1,4-xylanase, Xyl10E, was cloned and expressed in Escherichia coli. Functional analysis of the recombinant metagenome-derived enzyme showed high specificity towards beechwood xylan (288.1 IU/mg), with the optimum activity at 50 °C and a pH-activity range from 5 to 10. These characteristics suggest that Xy110E may be a promising candidate for further development in lignocellulose deconstruction applications.

59 BASIC BIOLOGICAL SCIENCES↗

Method development for comprehensive extraction and analysis of marine toxins: Liquid-liquid extraction and tandem liquid chromatography separations coupled to electrospray tandem mass spectrometry

Toxins from biological sources are recognized as potential chemical weapon threats, with saxitoxin and ricin listed by the chemical weapons convention (CWC) as schedule one agents (CWC reference). These two toxins represent a metabolite (saxitoxin) and protein (ricin) from algal and plant sources, respectively. An array of toxins have been listed as "select agents" by the Health and Human Services (HHS) select agent program, including ricin, abrin, saxitoxin, tetrodotoxin, specific paralytic alpha conotoxin peptides, T-2 toxin, diacetoxyscirpenols, botulinum toxins, and staphylococcal enterotoxins [1]. The quantities of these toxins dictate whether they are considered select agents with federal oversight of their storage and use. While this list captures some of the naturally occurring toxins that may pose a threat to the public, there are a number of other naturally occurring toxins that may also be a concern.

biodetection↗

Materials Based on Solid Solutions of Bismuth Chalcogenides of n-Type Conductivity Prepared by Melt Crystallization in a Liquid

The microstructure, mechanical, and thermoelectric properties of samples of the n-type Bi{sub 2}Te{sub 3}–Bi{sub 2}Se{sub 3} solid-solution samples containing 6, 8, and 10 mol % Bi{sub 2}Se{sub 3}, doped with antimony iodide, cadmium chloride, and hexabromobenzene, are investigated. The samples are formed by hot pressing and the extrusion of granules prepared by melt crystallization in a liquid and ground in a mortar, cutting mill, and ball mill. Measurements are performed at room temperature and in the range of 100–600 K. The formation conditions and compositions of materials with an ultimate compressive strength of ~250 MPa and thermoelectric efficiency of (ZT){sub max} = (0.9–1.0) in the temperature range of 320–430 K are found.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Elemental and Isotopic Analysis of Uranium Oxide an NIST Glass Standards by FEMTOSECOND-LA-ICP-MIC-MS

The objective of this work was to test and demonstrate the analytical figures of merit of a femtosecond-laser ablation (fs-LA) system coupled with an inductively coupled plasma-multi-ion collector-mass spectrometer (ICP-MIC-MS). The mobile fs-LA sampling system was designed and assembled at Ames Laboratory and shipped to Oak Ridge National Laboratory (ORNL), where it was integrated with an ICP-MIC-MS. The test period of the integrated systems was February 2-6, 2009. Spatially-resolved analysis of particulate samples is accomplished by 100-shot laser ablation using a fs-pulsewidth laser and monitoring selected isotopes in the resulting ICP-MS transient signal. The capability of performing high sensitivity, spatially resolved, isotopic analyses with high accuracy and precision and with virtually no sample preparation makes fs-LA-ICP-MIC-MS valuable for the measurement of actinide isotopes at low concentrations in very small samples for nonproliferation purposes. Femtosecond-LA has been shown to generate particles from the sample that are more representative of the bulk composition, thereby minimizing weaknesses encountered in previous work using nanosecond-LA (ns-LA). The improvement of fs- over ns-LA sampling arises from the different mechanisms for transfer of energy into the sample in these two laser pulse-length regimes. The shorter duration fs-LA pulses induce less heating and cause less damage to the sample than the longer ns pulses. This results in better stoichiometric sampling (i.e., a closer correlation between the composition of the ablated particles and that of the original solid sample), which improves accuracy for both intra- and inter-elemental analysis. The primary samples analyzed in this work are (a) solid uranium oxide powdered samples having different {sup 235}U to {sup 238}U concentration ratios, and (b) glass reference materials (NIST 610, 612, 614, and 616). Solid uranium oxide samples containing {sup 235}U in depleted, natural, and enriched abundances were analyzed as particle aggregates immobilized in a collodion substrate. The uranium oxide samples were nuclear reference materials (CRMs U0002, U005-A, 129-A, U015, U030-A, and U050) obtained from New Brunswick Laboratory-USDOE.

07 ISOTOPE AND RADIATION SOURCES↗

Steps to achieving high-resolution NMR spectroscopy on solutions at GPa pressure

Recent theoretical advances and molecular-dynamic estimates of the dielectric constant of water have extended the HKF model for aqueous solution chemistry up to 6.0 gigapascals (GPa), which are conditions well beyond the capabilities of conventional NMR spectroscopy (Pan et al., 2013; Sverjensky et al., 2014, see also Wasserman and others, 1995). These developments provide strong motivation to design a simple NMR probe that allows experiments on solutions, at high resolution, to pressures of a few GPa (Pautler et al., 2014; Ochoa et al., 2015; 2016). Here we describe the performance of a compact NMR probe that can reach several GPa pressures. The probe is made by placing a solenoid microcoil inside of a standard piston-cylinder device used in solid-state physics. High pressures are achieved in the sample by applying force to a coaxial piston. Early designs of the probe, although useful, were limited in sample size to ~10-15μL. Here we describe modifications that allow greatly improved resolution and sensitivity, including 1H-1H NMR correlation spectroscopy, on solutions at 2.8 GPa pressure. Sample sizes can be expanded if, instead of a standard NMR spectrometer that is built around a superconducting magnet, one employs a magnetic-resonance imaging (MRI) system that is built around a permanent magnet. The MRI systems can apply larger magnetic field gradients than conventional spectrometers, and thus have more robust shimming capability, which is needed because of the juxtaposition of different alloys in the pressure cell. More importantly, these systems can have magnetic fields that are oriented perpendicular to the magnet bore, which allows rotation of the coil within the axis of the pressure cell to increase sample volumes and pressure. Sensitivity is improved by replacing the traditional, but reduced-volume, closed sample container mounted in the center of the NMR detection coil with an open NMR coil that dangles freely in solution, thus making the sample solution itself the pressure-transmission fluid. The efficacy of these modifications are demonstrated by measuring 1 H NMR spectra for ethyl alcohol and ethyl alcohol/methyl alcohol mixtures at pressures up to 2.8 GPa. As a result, further developments are discussed that will allow geochemists to acquire aqueous solution NMR spectra at higher 3-4 GPa pressures.

58 GEOSCIENCES↗

The 60 Month All-Sky Burst Alert Telescope Survey of Active Galactic Nucleus and the Anisotropy of Nearby AGNs

Surveys above 10 keV represent one of the best resources to provide an unbiased census of the population of active galactic nuclei (AGNs). We present the results of 60 months of observation of the hard X-ray sky with Swift/Burst Alert Telescope (BAT). In this time frame, BAT-detected (in the 15-55 keV band) 720 sources in an all-sky survey of which 428 are associated with AGNs, most of which are nearby. Our sample has negligible incompleteness and statistics a factor of approx. 2 larger over similarly complete sets of AGNs. Our sample contains (at least) 15 bona fide Compton-thick AGNs and 3 likely candidates. Compton-thick AGNs represent approx. 5% of AGN samples detected above 15 keV. We use the BAT data set to refine the determination of the log N-log S of AGNs which is extremely important, now that NuSTAR prepares for launch, toward assessing the AGN contribution to the cosmic X-ray background. We show that the log N-log S of AGNs selected above 10 keV is now established to approx. 10% precision. We derive the luminosity function of Compton-thick AGNs and measure a space density of 7.9(+4.1/−2.9)× 10(exp −5)/cubic Mpc for objects with a de-absorbed luminosity larger than 2 × 10(exp 42) erg / s. As the BAT AGNs are all mostly local, they allow us to investigate the spatial distribution of AGNs in the nearby universe regardless of absorption. We find concentrations of AGNs that coincide spatially with the largest congregations of matter in the local (much < 85 Mpc) universe. There is some evidence that the fraction of Seyfert 2 objects is larger than average in the direction of these dense regions..

SURVEY↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements?and to protect our science from human contamination?we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

planetary protection↗

A technique for synthesizing metal tritide standards

Before surplus plutonium pits can be decommissioned and converted into metal oxides to be used as reactor fuels, residual tritium must be reduced to an acceptable level. We have developed two analytical methods involving melting and acid dissolution, combined with liquid scintillation counting as a quantitative and sensitive technique for measuring residual tritium in Pu metal. The detection limit, linearity, and reproducibility of these analytical methods must be validated with a series of metal tritide standards. Since there are no commercially available metal tritide standards, we have developed a technique for their synthesis. The synthesis of these low-level metal tritide standards is accomplished by charging cerium powder with a known amount of tritium to form a master cerium tritide alloy and then by aliquoting from this master alloy and diluting with pure cerium powder to form a series of standards with different tritium concentrations. The major difficulty in synthesizing these standards is that the samples contain extremely low levels of tritium, which span over three decades of concentrations. The synthesis technique and initial data obtained for cerium hydride samples will be presented. (authors)

36 MATERIALS SCIENCE↗

Analyzing the Effect of CeB{sub 6} on Microstructure and Mechanical Properties of High-Speed Steel Consolidated by Powder Metallurgy

By adding various amounts of CeB{sub 6}, high-speed steel (M3:2) was consolidated by powder metallurgy in the form of sintering. The addition of CeB{sub 6} improved the density of the sintered steel and the formation of M{sub 6}C phase in microstructure. It is speculated that CeB{sub 6} was decomposed into boron and cerium. Boron atoms were enriched in M{sub 6}C carbide phases, but cerium atoms were mainly clustered on grain boundary while they were converted to oxides, whereby the mechanical properties were improved. For example, upon the sintering at 1210 °C, relative density ~ 98.5% and average grain size ~ 18 μm were obtained with CeB{sub 6} content at 0.3 wt.%. Excellent mechanical properties, e.g., the Rockwell hardness ~ 52 HRC, flexural strength ~ 3.05 GPa, and fracture toughness ~ 40.92 MPa m{sup 1/2}, were achieved in the sample containing 0.3 wt.% CeB{sub 6}, which implies accordingly remarkable increases by 23.5, 38.1, and 23.7%, of the properties compared with those in the sample free of CeB{sub 6}.

36 MATERIALS SCIENCE↗

Effect of neutron and ion irradiation on the metal matrix and oxide corrosion layer on Zr-1.0Nb cladding alloys

A detailed study has been carried out on recrystallised Zr-1.0Nb alloys corroded and irradiated under different conditions, including ex-autoclave and ex-reactor samples. After 540 days in reactor and damage around 5 dpa, the neutron irradiated sample shows no serious evidence for radiation enhanced corrosion and is still in pre-transition stage. The good corrosion resistance of the neutron irradiated Zr-1.0Nb can be related to the higher volume fraction of tetragonal phase and fewer interconnected nano porosity/cracks in the oxide. This indicates less tetragonal to monoclinic transition, leads to more protective oxide in the neutron irradiated sample, containing little evidence for short circuit paths for the penetration of oxygen or water towards the metal-oxide interface. These observations on a sample with a slow overall oxidation rate are consistent with the hypothesis that interconnected porosity can lead to early transitions and rapid oxidation. Tetragonal oxide can be either stabilised by irradiation, or stabilised by local release of impurity species from SPPs such as dissolution of Fe from Zr-Nb-Fe precipitates or radiation introduced precipitates (RIPs) which is likely to be small β-Nb clusters. The oxide consists of well-aligned columnar-equiaxed microstructure in the autoclave sample while a more complex oxide grain structure was observed in the neutron-irradiated sample. As oxide continues to grow, there are more < a > and < c > loops, dissolved Fe and RIPs in the metal matrix, however, the corrosion rate is low enough for the tetragonal oxide to stabilise and suboxide + Zr(Osat) phases exist for protectiveness, so there is no enhanced corrosion after radiation. In situ ion irradiation in the TEM revealed no visible defect clusters or voids in the oxide, suggesting that radiation damage to the metal matrix rather than oxide may have a stronger effect on corrosion mechanisms after neutron irradiation, however, cascade damages are not visible in this case. Neutron irradiation also seems to have little effect on promoting fast oxidation or dissolution of β-Nb precipitates into the surrounding oxide or metal during irradiation. Furthermore, these results are discussed in the light of the current mechanisms for corrosion of nuclear fuel cladding alloys.

(S)TEM↗

Location and oxidation state of iron in Fe-substituted CuInS{sub 2} chalcopyrites

CuIn{sub 1-x}Fe{sub x}S{sub 2}(x=0-0.30) was synthesized via high-temperature, solid-state synthesis. Phase-pure materials were found in samples where x=0-0.15, after which a secondary phase became apparent. The materials were characterized with the use of X-ray powder diffraction (XRPD), and Reitveld refinement revealed a linear decrease in unit cell volume as the amount of iron substitution increases in accordance with Vegard's Law. Inductively coupled plasma (ICP) confirms that the actual stoichiometry is close to the nominal composition of the materials. The temperature for both the chalcopyrite-to-sphalerite and the sphalerite-to-wurtzite phase transitions decreases with increasing iron substitution for indium. These findings suggest that the Fe is being randomly incorporated into the crystal structure of the CuInS{sub 2}. X-ray photoelectron spectroscopy (XPS) measurements were used to determine the oxidation state of the ions (Cu{sup 1+}, In{sup 3+,} and S{sup 2-}), and Fe{sup 57} Moessbauer spectroscopy verified that the iron is in the 3{sup +} oxidation state. Band gaps of the solid solution were estimated to be in the range of 0.70-0.85 eV. Rietveld refinement of neutron diffraction data indicates that the iron is occupying the In site within the chalcopyrite structure. - Graphical abstract: CuIn{sub 1-x}Fe{sub x}S{sub 2} samples were prepared by solid-state synthesis. X-ray photoelectron spectroscopy and Moessbauer spectroscopy indicate Cu{sup +}, In{sup 3+}, Fe{sup 3+} and S{sup 2-} in the samples. Rietveld refinement of neutron powder diffraction data shows Fe{sup 3+} residing on the indium site. The band gaps of the iron-containing samples decrease to {approx}0.7 eV. Highlights: Black-Right-Pointing-Pointer X-ray photoelectron spectroscopy confirms the presence of Cu{sup +}, In{sup 3+} and S{sup 2-}. Black-Right-Pointing-Pointer Moessbauer spectroscopy indicates the presence of Fe{sup 3+}. Black-Right-Pointing-Pointer Rietveld refinement of neutron powder diffraction data shows iron on the indium site. Black-Right-Pointing-Pointer The band gap decreases to {approx}0.7 eV with only 5% iron substitution. Black-Right-Pointing-Pointer Additional characterization is reported.

36 MATERIALS SCIENCE↗

Structure refinement and dielectric relaxation of M-type Ba, Sr, Ba-Sr, and Ba-Pb hexaferrites

M-type hexaferrites with compositions BaFe{sub 12}O{sub 19} (BFO), SrFe{sub 12}O{sub 19} (SFO), Ba{sub 0.5}Sr{sub 0.5}Fe{sub 12}O{sub 19} (BSFO), and Ba{sub 0.5}Pb{sub 0.5}Fe{sub 12}O{sub 19} (BPFO) were synthesized by commercial solid state reaction method. The Rietveld refinement of x-ray powder diffraction revealed a single hexagonal phase with space group P6{sub 3}/mmc for BFO, SFO, and BSFO samples, whereas BPFO sample contains hematite ({alpha}-Fe{sub 2}O{sub 3}) phase with space group R3c along with the M-type main phase. All the samples show dispersion in dielectric constant ({epsilon} Prime ) and dielectric loss (tan {delta}) values with frequency. The values of {epsilon} Prime and tan {delta} increase with increase in temperature due to increase in the number of charge carriers and their mobilities, which are thermally activated. The reciprocal temperature dependence of conductivity ({sigma}{sub ac}) and the most probable relaxation time ({tau}{sub M Double-Prime }) satisfies the Arrhenius relation. A perfect overlapping of the normalized plots of modulus isotherms on a single 'super curve' for all the studied temperatures reveals a temperature independence of dynamic processes involved in conduction and for relaxation. Further, the complex plots of M{sup *} (M Double-Prime vs M Prime ) indicate that dc conductivity dominates in the region below the M Double-Prime {sub max} point. Above M Double-Prime {sub max}, the variations follow Jonscher power law ({sigma} = A{omega}{sup s}) implying that ac conductivity is dominating in this region. Among the prepared samples, SFO hexaferrite has lowest values of {sigma}{sub ac}, {epsilon} Prime , and tan {delta} making it suitable for use in microwave devices.

36 MATERIALS SCIENCE↗

Polarity dependence of the electrical characteristics of Ag reflectors for high-power GaN-based light emitting diodes

We report on the polarity dependence of the electrical properties of Ag reflectors for high-power GaN-based light-emitting diodes. The (0001) c-plane samples become ohmic after annealing in air. However, the (11–22) semi-polar samples are non-ohmic after annealing, although the 300 °C-annealed sample shows the lowest contact resistivity. The X-ray photoemission spectroscopy (XPS) results show that the Ga 2p core level for the c-plane samples experiences larger shift toward the valence band than that for the semi-polar samples. The XPS depth profile results show that unlike the c-plane samples, the semi-polar samples contain some amounts of oxygen at the Ag/GaN interface regions. The outdiffusion of Ga atoms is far more significant in the c-plane samples than in the semi-polar samples, whereas the outdiffusion of N atoms is relatively less significant in the c-plane samples. On the basis of the electrical and XPS results, the polarity dependence of the electrical properties is described and discussed.

36 MATERIALS SCIENCE↗

CfA3: 185 TYPE Ia SUPERNOVA LIGHT CURVES FROM THE CfA

We present multiband photometry of 185 type-Ia supernovae (SNe Ia), with over 11,500 observations. These were acquired between 2001 and 2008 at the F. L. Whipple Observatory of the Harvard-Smithsonian Center for Astrophysics (CfA). This sample contains the largest number of homogeneously observed and reduced nearby SNe Ia (z {approx}< 0.08) published to date. It more than doubles the nearby sample, bringing SN Ia cosmology to the point where systematic uncertainties dominate. Our natural system photometry has a precision of {approx}<0.02 mag in BVRIr'i' and {approx}<0.04 mag in U for points brighter than 17.5 mag. We also estimate a systematic uncertainty of 0.03 mag in our SN Ia standard system BVRIr'i' photometry and 0.07 mag for U. Comparisons of our standard system photometry with published SN Ia light curves and comparison stars, where available for the same SN, reveal agreement at the level of a few hundredths mag in most cases. We find that 1991bg-like SNe Ia are sufficiently distinct from other SNe Ia in their color and light-curve-shape/luminosity relation that they should be treated separately in light-curve/distance fitter training samples. The CfA3 sample will contribute to the development of better light-curve/distance fitters, particularly in the few dozen cases where near-infrared photometry has been obtained and, together, can help disentangle host-galaxy reddening from intrinsic supernova color, reducing the systematic uncertainty in SN Ia distances due to dust.

99 GENERAL AND MISCELLANEOUS↗

THE LICK/SDSS LIBRARY. II. [Ca/Fe] AND [Mg/Fe] IN F, G, AND K STARS FROM SDSS-DR7

We analyzed the spectra of 17,600 F, G, and K stars extracted from the seventh Sloan Digital Sky Survey Data Release (SDSS-DR7) database in order to derive ([{alpha}/Fe]), [Ca/Fe], and [Mg/Fe] ratios. Particular attention has been devoted to estimating homogeneous and self-consistent atmospheric parameter values, T{sub eff}, log g, and [Fe/H], by comparing synthetic and observational Lick/SDSS indices. We present results for the sub-sample of more than 4000 spectra whose overall quality allowed us to derive fairly accurate stellar atmospheric parameter values and, therefore, reliable abundance ratios. A Monte Carlo approach was adopted to evaluate both the errors in the observational Lick/SDSS indices and in the derived parameter estimates. The analysis of the trends of [Ca/Fe] and [Mg/Fe] versus [Fe/H] pointed out that (1) the [Ca/Fe] and [Mg/Fe] ratios increase with decreasing [Fe/H] with different slopes reaching maximum average levels of +0.25 and +0.40 dex at [Fe/H] {approx_equal} -1.75, respectively; (2) our sample contains, at a given [Fe/H], stars characterized by significantly different amounts of {alpha}-enhancement, thus belonging to different Galactic populations; and (3) the analyzed sample shows a predominance of thick disk stars for [Fe/H] > - 0.5 and the presence of stars belonging to the 'high-{alpha}' halo population for -2.0 < [Fe/H] <-0.5.

79 ASTRONOMY AND ASTROPHYSICS↗

THE ACS NEARBY GALAXY SURVEY TREASURY. VIII. THE GLOBAL STAR FORMATION HISTORIES OF 60 DWARF GALAXIES IN THE LOCAL VOLUME

We present uniformly measured star formation histories (SFHs) of 60 nearby (D {approx}< 4 Mpc) dwarf galaxies based on color-magnitude diagrams of resolved stellar populations from images taken with the Hubble Space Telescope and analyzed as part of the ACS Nearby Galaxy Survey Treasury program (ANGST). This volume-limited sample contains 12 dwarf spheroidal (dSph)/dwarf elliptical (dE), 5 dwarf spiral, 28 dwarf irregular (dI), 12 dSph/dI (transition), and 3 tidal dwarf galaxies. The sample spans a range of {approx}10 mag in M{sub B} and covers a wide range of environments, from highly interacting to truly isolated. From the best-fit SFHs, we find three significant results for dwarf galaxies in the ANGST volume: (1) the majority of dwarf galaxies formed the bulk of their mass prior to z {approx} 1, regardless of current morphological type; (2) the mean SFHs of dIs, transition dwarf galaxies (dTrans), and dSphs are similar over most of cosmic time, and only begin to diverge a few Gyr ago, with the clearest differences between the three appearing during the most recent 1 Gyr; and (3) the SFHs are complex and the mean values are inconsistent with simple SFH models, e.g., single bursts, constant star formation rates (SFRs), or smooth, exponentially declining SFRs. The mean SFHs show clear divergence from the cosmic SFH at z {approx}< 0.7, which could be evidence that low-mass systems have experienced delayed star formation relative to more massive galaxies. The sample shows a strong density-morphology relationship, such that the dSphs in the sample are less isolated than the dIs. We find that the transition from a gas-rich to gas-poor galaxy cannot be solely due to internal mechanisms such as stellar feedback, and instead is likely the result of external mechanisms, e.g., ram pressure and tidal stripping and tidal forces. In terms of their environments, SFHs, and gas fractions, the majority of the dTrans appear to be low-mass dIs that simply lack H{alpha} emission, similar to Local Group (LG) dTrans DDO 210. However, a handful of dTrans have remarkably low gas fractions, suggesting that they have nearly exhausted their gas supply, analogous to LG dTrans such as Phoenix. Finally, we have also included extensive exploration of uncertainties in the SFH recovery method, including the optimization of time resolution, the effects of photometric depth, and impact of systematic uncertainties due to the limitations in current stellar evolution models.

79 ASTRONOMY AND ASTROPHYSICS↗

ExoMars Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Mass Spectrometry (LDI-MS) Analysis of Phototrophic Communities from a Silica-Depositing Hot Spring in Yellowstone National Park, USA

The Mars Organic Molecule Analyzer (MOMA) is a key scientific instrument on the ExoMars Rover mission. MOMA is designed to detect and characterize organic compounds, over a wide range of volatility and molecular weight, in samples obtained from up to two meters below the martian surface. Thorough analog sample studies are required to best prepare to interpret MOMA data collected on Mars. We present here the MOMA characterization of Mars analog samples collected from an alkaline silica depositing hot spring in Yellowstone National Park, WY, USA. These samples contain microbial streamer communities composed primarily of oxygenic and anoxygenic phototrophs. Additionally, in a study focused on detection of key classes of nonvolatile organics, samples of microbial streamers and their total lipid extract (TLE) have been measured on a MOMA Engineering Test Unit (ETU) instrument using its laser desorption/ionization mass spectrometry (LDI-MS) mode. MOMA LDI-MS detected a variety of lipids and pigments in the TLE sample. Species such as chlorophyll a were also detected from the streamer sample with the help of mass isolation. The results add to the LDI-MS sample characterization database, as well as demonstrate the benefit of using mass isolation on the MOMA instrument to reveal the presence of complex organics, and potential biomarkers, preserved in a natural sample, providing guidance to the in situ analysis of surface samples during Mars operations.

59 BASIC BIOLOGICAL SCIENCES↗