Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The slow wave resonance cone in the collisional regime

In the low-density edge plasma of tokamaks, ion cyclotron range of frequencies actuators may parasitically emit slow waves. If the density is sufficiently low, which may be common in large future devices such as international thermonuclear experimental reactor (ITER), these slow waves take the form of so-called resonance cones. The traditional theoretical description of this wave mode relies on formally relating an electrostatic approximation of the frequency-domain wave equation to a time-domain wave equation and relating the cone angle to the wave speed in the time-domain wave equation. In the cold plasma collisional regime, that wave speed is complex. We investigate that scenario in this work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability of drift-cyclotron loss-cone waves in H-mode plasmas

The drift-cyclotron loss-cone mode was first studied in mirror machines. In such devices, particles with small pitch angles are not confined, creating a hole in the velocity distribution function that is a source of free energy and leads to micro-instabilities in the cyclotron-range of frequencies. In the edge region of tokamak devices operating under H-mode conditions, ion loss also occurs. In this case, gradient drift carries ions moving opposite to the plasma current preferentially into the divertor, creating a one-sided loss cone. A simple analysis shows that for the quiescent H-mode plasmas in DIII-D the critical gradient for instability is exceeded within 2 cm of the separatrix, and the maximum growth rate at the separatrix is 3×10 7 s -1 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active rotor coning for a 25 MW downwind offshore wind turbine

A two-bladed downwind turbine system was upscaled from 13.2 MW to 25 MW by redesigning aerodynamics, structures, and controls. In particular, three 25-MW rotors were developed, and the final version is a fully redesigned model of the original rotor. Despite their radically large sizes, it was found that these 25-MW turbine rotors satisfy this limited set of structural design drivers at the rated condition and that larger blade lengths are possible with conewise load-alignment. In addition, flapwise morphing (varying the cone angle with a wind-speed schedule) was investigated to minimize mean and fluctuating blade root bending loads using steady inflow proxies for the maximum and lifetime damage equivalent load moments. Compared to the fixed coned rotor case, morphing can provide an Annual Energy Production (AEP) increase of 6%, and the maximum blade root flapwise bending moment increases 21% (still under the constraint, i.e., 10% of the ultimate moments) as a trade-off. The resulting series of 25-MW rotors can be a valuable baseline for further development and assessment of ultra-large-scale wind turbines.

17 WIND ENERGY↗

THE BIRTH RATE OF SNe Ia FROM HYBRID CONe WHITE DWARFS

Considering the uncertainties of the C-burning rate (CBR) and the treatment of convective boundaries, Chen et al. found that there is a regime where it is possible to form hybrid CONe white dwarfs (WDs), i.e., ONe WDs with carbon-rich cores. As these hybrid WDs can be as massive as 1.30 M {sub ☉}, not much mass needs to be accreted for these objects to reach the Chandrasekhar limit and to explode as Type Ia supernovae (SNe Ia). We have investigated their contribution to the overall SN Ia birth rate and found that such SNe Ia tend to be relatively young with typical time delays between 0.1 and 1 Gyr, where some may be as young as 30 Myr. SNe Ia from hybrid CONe WDs may contribute several percent to all SNe Ia, depending on the common-envelope ejection efficiency and the CBR. We suggest that these SNe Ia may produce part of the 2002cx-like SN Ia class.

79 ASTRONOMY AND ASTROPHYSICS↗

Mock light-cones and theory friendly catalogues for the CANDELS survey

Here we present mock catalogues created to support the interpretation of the Cosmic Assembly Near-IR Deep Extragalactic Legacy Survey (CANDELS). We extract haloes along past light-cones from the Bolshoi Planck dissipationless N-body simulations and populate these haloes with galaxies using two different independently developed semi-analytic models of galaxy formation and the empirical model UNIVERSEMACHINE. Our mock catalogues have geometries that encompass the footprints of observations associated with the five CANDELS fields. In order to allow field-to-field variance to be explored, we have created eight realizations of each field. In this paper, we present comparisons with observable global galaxy properties, including counts in observed frame bands, luminosity functions, colour–magnitude distributions and colour–colour distributions. We additionally present comparisons with physical galaxy parameters derived from SED fitting for the CANDELS observations, such as stellar masses and star formation rates. We find relatively good agreement between the model predictions and CANDELS observations for luminosity and stellar mass functions. We find poorer agreement for colours and star formation rate distributions. All of the mock light-cones as well as curated ‘theory friendly’ versions of the observational CANDELS catalogues are made available through a web-based data hub.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovery of an edge-on galaxy with X-shaped bi-cone – SDSS J171359.00+333625.5

ABSTRACT Using the integral field unit (IFU) data from Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey, we study the kinematics of gas and stellar components in an edge-on Seyfert 2 galaxy, SDSS J171359.00+333625.5, with X-shaped bi-conical outflows. The gas and stars therein are found to be counter-rotating, indicating that the collision between the inner and external gas might be an effective way to dissipate the angular momentum, which leads to remarkable gas accretion into the galaxy centre. Large [O iii]λ5007 equivalent width and AGN-like line ratio in the large bi-conical region suggest that the gas is ionized by the central AGN. The gas velocity in the bi-cone region shows that ionized gas is receding relative to the galaxy centre, which could be the joint effect of inflows, outflows, and disc rotation. We are probably witnessing the case where a great amount of gas in the disc is being efficiently accreted into the central black hole, and the AGN-driven galactic winds are blown out along the bi-cone. The kinematics of oxygen, including rotation velocity and velocity dispersion, is different from other elements, like hydrogen, nitrogen, and sulphur. The rotation velocity estimated from oxygen is slower than from other elements. The velocity dispersion of other elements follows galactic gravitational potential, while the velocity dispersion of oxygen stays roughly constant along the galactic major-axis. The further advanced observations, e.g. of cold gas or with an IFU of higher spatial resolution, are required to better understand this object.

Bao, Min↗

Tensor-polarized parton density in the 𝑁 → Δ transition from the large-𝑁 𝑐 light-cone wave function

The tensor-polarized parton density is defined by the forward matrix element of a partonic operator in the 𝑁 → Δ transition. In this work, we investigate it by employing the large-𝑁 𝑐 light-cone wave function derived from the mean-field approach. The mean-field picture is based on low-energy effective dynamics in the large-𝑁 𝑐 limit, where the baryon wave function is formulated in the rest frame. By exploiting the covariance of the mean-field solution, we derive the corresponding large-𝑁 𝑐 light-cone wave function—decomposed unambiguously into 3⁢𝑄 , 5⁢𝑄 , 7⁢𝑄 , and higher Fock components—in the infinite momentum frame. Evaluating the overlap of these wave functions, we derive an overlap representation of the tensor-polarized parton density in the 𝑁 → Δ transition and find that the leading contribution arises from the 5⁢𝑄 Fock sector. This indicates that the tensor-polarized parton density directly probes the genuine 5⁢𝑄 component and is governed by chiral dynamics. Our numerical analysis shows that the 𝑁 → Δ tensor-polarized parton density is suppressed, consistent with standard large-𝑁 𝑐 expectations. Finally, we establish connections among the tensor-polarized parton density, the generalized parton distribution 𝐻 𝑋 , and the energy-momentum tensor form factor 𝐹 4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermalization and light cones in a model with weak integrability breaking

Here, we employ equation-of-motion techniques to study the nonequilibrium dynamics in a lattice model of weakly interacting spinless fermions. Our model provides a simple setting for analyzing the effects of weak integrability-breaking perturbations on the time evolution after a quantum quench. We establish the accuracy of the method by comparing results at short and intermediate times to time-dependent density matrix renormalization group computations. For sufficiently weak integrability-breaking interactions we always observe prethermalization plateaus , where local observables relax to nonthermal values at intermediate time scales. At later times a crossover towards thermal behavior sets in. We determine the associated time scale, which depends on the initial state, the band structure of the noninteracting theory, and the strength of the integrability-breaking perturbation. Our method allows us to analyze in some detail the spreading of correlations and in particular the structure of the associated light cones in our model. We find that the interior and exterior of the light cone are separated by an intermediate region, the temporal width of which appears to scale with a universal power law t 1/3 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gap between holographic and quantum mechanical extreme rays of the subadditivity cone

We show via explicit construction that for six or more parties, there exist extreme rays of the subadditivity cone that can be realized by quantum states, but not by holographic states. This is a counterexample to a conjecture first formulated in Hernández-Cuenca et al. [The holographic entropy cone from marginal independence, J. High Energy Phys. 09 (2022) 190.], and implies the existence of deep holographic constraints that restrict the allowed patterns of independence among various subsystems beyond the universal quantum mechanical restrictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Holographic entropy cone beyond AdS/CFT

We extend all known area inequalities obeyed by Ryu-Takayanagi surfaces of anti–de Sitter boundary regions—the holographic entropy cone—to static generalized entanglement wedges of bulk regions in arbitrary spacetimes. The generalized holographic entropy cone is subject to a mutual independence condition on the bulk regions: each bulk input region must be outside the entanglement wedge of the union of all others. The condition captures when gravitating regions involve fundamentally distinct degrees of freedom despite the nonlocality inherent in the holographic principle.

Quantum gravity↗

Operator Lévy Flight: Light Cones in Chaotic Long-Range Interacting Systems

We argue that chaotic power-law interacting systems have emergent limits on information propagation, analogous to relativistic light cones, which depend on the spatial dimension d and the exponent α governing the decay of interactions. Using the dephasing nature of quantum chaos, we map the problem to a stochastic model with a known phase diagram. A linear light cone results for α ≥ $\textit{d}$ + 1/2. We also provide a Lévy flight (long-range random walk) interpretation of the results and show consistent numerical data for 1D long-range spin models with 200 sites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A general framework and review of scatter correction methods in x-ray cone-beam computerized tomography. Part 1: Scatter compensation approaches

Since scattered radiation in cone-beam volume CT implies severe degradation of CT images by quantification errors, artifacts, and noise increase, scatter suppression is one of the main issues related to image quality in CBCT imaging. The aim of this review is to structurize the variety of scatter suppression methods, to analyze the common structure, and to develop a general framework for scatter correction procedures. In general, scatter suppression combines hardware techniques of scatter rejection and software methods of scatter correction. The authors emphasize that scatter correction procedures consist of the main components scatter estimation (by measurement or mathematical modeling) and scatter compensation (deterministic or statistical methods). The framework comprises most scatter correction approaches and its validity also goes beyond transmission CT. Before the advent of cone-beam CT, a lot of papers on scatter correction approaches in x-ray radiography, mammography, emission tomography, and in Megavolt CT had been published. The opportunity to avail from research in those other fields of medical imaging has not yet been sufficiently exploited. Therefore additional references are included when ever it seems pertinent. Scatter estimation and scatter compensation are typically intertwined in iterative procedures. It makes sense to recognize iterative approaches in the light of the concept of self-consistency. The importance of incorporating scatter compensation approaches into a statistical framework for noise minimization has to be underscored. Signal and noise propagation analysis is presented. A main result is the preservation of differential-signal-to-noise-ratio (dSNR) in CT projection data by ideal scatter correction. The objective of scatter compensation methods is the restoration of quantitative accuracy and a balance between low-contrast restoration and noise reduction. In a synopsis section, the different deterministic and statistical methods are discussed with respect to their properties and applications. The current paper is focused on scatter compensation algorithms. The multitude of scatter estimation models will be dealt with in a separate paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequency content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic tracking of implanted fiducial markers in cone beam CT projection images

Purpose: This paper describes a novel method for simultaneous intrafraction tracking of multiple fiducial markers. Although the proposed method is generic and can be adopted for a number of applications including fluoroscopy based patient position monitoring and gated radiotherapy, the tracking results presented in this paper are specific to tracking fiducial markers in a sequence of cone beam CT projection images. Methods: The proposed method is accurate and robust thanks to utilizing the mean shift and random sampling principles, respectively. The performance of the proposed method was evaluated with qualitative and quantitative methods, using data from two pancreatic and one prostate cancer patients and a moving phantom. The ground truth, for quantitative evaluation, was calculated based on manual tracking preformed by three observers. Results: The average dispersion of marker position error calculated from the tracking results for pancreas data (six markers tracked over 640 frames, 3840 marker identifications) was 0.25 mm (at iscoenter), compared with an average dispersion for the manual ground truth estimated at 0.22 mm. For prostate data (three markers tracked over 366 frames, 1098 marker identifications), the average error was 0.34 mm. The estimated tracking error in the pancreas data was < 1 mm (2 pixels) in 97.6% of cases where nearby image clutter was detected and in 100.0% of cases with no nearby image clutter. Conclusions: The proposed method has accuracy comparable to that of manual tracking and, in combination with the proposed batch postprocessing, superior robustness. Marker tracking in cone beam CT (CBCT) projections is useful for a variety of purposes, such as providing data for assessment of intrafraction motion, target tracking during rotational treatment delivery, motion correction of CBCT, and phase sorting for 4D CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-beam breast computed tomography with a displaced flat panel detector array

Purpose: In cone-beam computed tomography (CBCT), and in particular in cone-beam breast computed tomography (CBBCT), an important issue is the reduction of the image artifacts produced by photon scatter and the reduction of patient dose. In this work, the authors propose to apply the detector displacement technique (also known as asymmetric detector or ''extended view'' geometry) to approach this goal. Potentially, this type of geometry, and the accompanying use of a beam collimator to mask the unirradiated half-object in each projection, permits some reduction of radiation dose with respect to conventional CBBCT and a sizeable reduction of the overall amount of scatter in the object, for a fixed contrast-to-noise ratio (CNR). Methods: The authors consider a scan configuration in which the projection data are acquired from an asymmetrically positioned detector that covers only one half of the scan field of view. Monte Carlo simulations and measurements, with their CBBCT laboratory scanner, were performed using PMMA phantoms of cylindrical (70-mm diameter) and hemiellipsoidal (140-mm diameter) shape simulating the average pendant breast, at 80 kVp. Image quality was evaluated in terms of contrast, noise, CNR, contrast-to-noise ratio per unit of dose (CNRD), and spatial resolution as width of line spread function for high contrast details. Results: Reconstructed images with the asymmetric detector technique deviate less than 1% from reconstruction with a conventional symmetric detector (detector view) and indicate a reduction of the cupping artifact in CT slices. The maximum scatter-to-primary ratio at the center of the phantom decreases by about 50% for both small and large diameter phantoms (e.g., from 0.75 in detector view to 0.40 in extended view geometry at the central axis of the 140-mm diameter PMMA phantom). Less cupping produces an increase of the CT number accuracy and an improved image detail contrast, but the associated increase of noise observed may produce a decrease of detail CNR. By simulating the energy deposited inside the phantoms, the authors evaluated a maximum 50% reduction of the absorbed dose at the expense of a decrease of CNR, for the half beam irradiation of the object performed with the displaced detector technique with respect to full beam irradiation. The decrease in CNR, and in absorbed dose as well, translates into a detail CNRD showing values comparable to or higher than the ones obtained for a conventional symmetric detector technique, attributed to the effect of decreased scatter in particular at the axis of the irradiated object. An estimate is provided (about 12%) for the average dose reduction possible in CBBCT at constant CNR for the average uncompressed breast (14 cm diameter, 50% glandularity), in case of minimum image overlapping in extended view. Conclusions: Simulations and experiments show that CBCT reconstructions with the displaced detector technique and with a half beam collimator are less affected by scatter artifacts, which could lead to some decrease of the radiation dose to the irradiated object with respect to a conventional reconstruction. This dose reduction is associated with increase of noise, decrease of CNR, but equal or improved CNRD values. The use of a small area detector would allow also to reduce the apparatus cost and to improve the data transfer speed with a corresponding increment of frame rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife{sup Registered-Sign} and linear accelerators equipped with microMLC and circular cones

Purpose: The use of small photon fields is now an established practice in stereotactic radiosurgery and radiotherapy. However, due to a lack of lateral electron equilibrium and high dose gradients, it is difficult to accurately measure the dosimetric quantities required for the commissioning of such systems. Moreover, there is still no metrological dosimetric reference for this kind of beam today. In this context, the first objective of this work was to determine and to compare small fields output factors (OF) measured with different types of active detectors and passive dosimeters for three types of facilities: a CyberKnife{sup Registered-Sign} system, a dedicated medical linear accelerator (Novalis) equipped with m3 microMLC and circular cones, and an adaptive medical linear accelerator (Clinac 2100) equipped with an additional m3 microMLC. The second one was to determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors introduced in a recently proposed small field dosimetry formalism for different active detectors.Methods: Small field sizes were defined either by microMLC down to 6 Multiplication-Sign 6 mm{sup 2} or by circular cones down to 4 mm in diameter. OF measurements were performed with several commercially available active detectors dedicated to measurements in small fields (high resolution diodes: IBA SFD, Sun Nuclear EDGE, PTW 60016, PTW 60017; ionizing chambers: PTW 31014 PinPoint chamber, PTW 31018 microLion liquid chamber, and PTW 60003 natural diamond). Two types of passive dosimeters were used: LiF microcubes and EBT2 radiochromic films.Results: Significant differences between the results obtained by several dosimetric systems were observed, particularly for the smallest field size for which the difference in the measured OF reaches more than 20%. For passive dosimeters, an excellent agreement was observed (better than 2%) between EBT2 and LiF microcubes for all OF measurements. Moreover, it has been shown that these passive dosimeters do not require correction factors and can then be used as reference dosimeters. Correction factors for the active detectors have then been determined from the mean experimental OF measured by the passive dosimeters.Conclusions: Four sets of correction factors needed to apply the new small field dosimetry formalism are provided for several active detectors. A protocol for small photon beams OF determination based on passive dosimeters measurements has been recently proposed to French radiotherapy treatment centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: Visibility of simulated microcalcifications

Purpose: To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer).Methods: Aluminum wires and calcium carbonate grains of various sizes were embedded in a paraffin cylinder to simulate imaging of calcifications in a breast. Phantoms were imaged with a benchtop experimental cone beam CT system at various exposure levels. In addition to the Dexela detector, a high pitch (50 μm), thin (150 μm) scintillator CMOS/CsI flat panel detector (C7921CA-09, Hamamatsu Corporation, Hamamatsu City, Japan) and a widely used low pitch (194 μm), thick (600 μm) scintillator aSi/CsI flat panel detector (PaxScan 4030CB, Varian Medical Systems) were also used in scanning for comparison. The images were independently reviewed by six readers (imaging physicists). The MC visibility was quantified as the fraction of visible MCs and measured as a function of the estimated mean glandular dose (MGD) level for various MC sizes and detectors. The modulation transfer functions (MTFs) and detective quantum efficiencies (DQEs) were also measured and compared for the three detectors used.Results: The authors have demonstrated that the use of a high pitch (75 μm) CMOS detector coupled with a thick (500 μm) CsI scintillator helped make the smaller 150–160, 160–180, and 180–200 μm MC groups more visible at MGDs up to 10.8, 9, and 10.8 mGy, respectively. It also made the larger 200–212 and 212–224 μm MC groups more visible at MGDs up to 7.2 mGy. No performance improvement was observed for 224–250 μm or larger size groups. With the higher spatial resolution of the Dexela detector based system, the apparent dimensions and shapes of MCs were more accurately rendered. The results show that with the aforementioned detector, a 73% visibility could be achieved in imaging 160–180 μm MCs as compared to 28% visibility achieved by the low pitch (194 μm) aSi/CsI flat panel detector. The measurements confirm that the Hamamatsu detector has the highest MTF, followed by the Dexel detector, and then the Varian detector. However, the Dexela detector, with its thick (500 μm) CsI scintillator and low noise level, has the highest DQE at all frequencies, followed by the Varian detector, and then the Hamamatsu detector. The findings on the MC visibility correlated well with the differences in MTFs, noise power spectra, and DQEs measured for these three detectors.Conclusions: The authors have demonstrated that the use of the CMOS type Dexela detector with its high pitch (75 μm) and thick (500 μm) CsI scintillator could help improve the MC visibility. However, the improvement depended on the exposure level and the MC size. For imaging larger MCs or scanning at high exposure levels, there was little advantage in using the Dexela detector as compared to the aSi type Varian detector. These findings correlate well with the higher measured DQEs of the Dexela detector, especially at higher frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-92: On-Line Cone Beam CT Based Planning for Emergency and Palliative Radiation Therapy

Purpose: To evaluate and develop the feasibility of on-line cone beam CT based planning for emergency and palliative radiotherapy treatments. Methods: Subsequent to phantom studies, a case library of 28 clinical megavoltage cone beam CT (MVCBCT) was built to assess dose-planning accuracies on MVCBCT for all anatomical sites. A simple emergency treatment plan was created on the MVCBCT and copied to its reference CT. The agreement between the dose distributions of each image pair was evaluated by the mean dose difference of the dose volume and the gamma index of the central 2D axial plane. An array of popular urgent and palliative cases was also evaluated for imaging component clearance and field-of-view. Results: The treatment cases were categorized into four groups (head and neck, thorax/spine, pelvis and extremities). Dose distributions for head and neck treatments were predicted accurately in all cases with a gamma index of >95% for 2% and 2 mm criteria. Thoracic spine treatments had a gamma index as low as 60% indicating a need for better uniformity correction and tissue density calibration. Small anatomy changes between CT and MVCBCT could contribute to local errors. Pelvis and sacral spine treatment cases had a gamma index between 90% and 98% for 3%/3 mm criteria. The limited FOV became an issue for large pelvis patients. Imaging clearance was difficult for cases where the tumor was positioned far off midline. Conclusion: The MVCBCT based dose planning and delivery approach is feasible in many treatment cases. Dose distributions for head and neck patients are unrestrictedly predictable. Some FOV restrictions apply to other treatment sites. Lung tissue is most challenging for accurate dose calculations given the current imaging filters and corrections. Additional clinical cases for extremities need to be included in the study to assess the full range of site-specific planning accuracies. This work is supported by Siemens.

60 APPLIED LIFE SCIENCES↗