Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Transactive HVAC Agent - Design and Performance Evaluation

Transactive energy systems are playing an increasingly important role in the efficient and reliable marketbased operation of the power grid. Since a significant portion of the residential building energy consumption is from heating ventilation and air conditioning (HVAC) systems, HVAC is one of the most promising resources to provide load flexibility. However, utilizing HVAC flexibility to provide various grid services while simultaneously maintaining consumer comfort and cost-reductions is challenging. This paper presents a design of a transactive HVAC agent (T-HVAC) to be used as a supervisory control for the HVAC system that can simultaneously ensure comfort and cost-reduction. In particular, the T-HVAC a) estimates HVAC thermal dynamics, b) ensures optimal operations of the HVAC system, and c) participates into markets, and d) implements a market-based control via controlling the thermostat temperature set-point. The T-HVAC performance is demonstrated through multiple scenarios and illustrations.

Demand flexibility, distribution system, HVAC, Tra↗

Transactive Electric Vehicle Agent: Design and Performance Evaluation

Transactive electric vehicle (TEV) agent enables the utilization of EVs’ flexible resources for the benefits of both utility and customer by active market participation. In this work, we propose a novel TEV agent optimization with a novel slider feature that models an individual customer’s willingness to participate in the transactive market. We characterize the customer comfort in EV’s context using a slider that provides flexibility to the customer to choose a trade-off between comfort and profit. Finally, the proposed optimization framework is used to investigate the comparative benefits of V2G technology compared to V1G.

day-ahead electricity market, electric vehicle, fl↗

Cooperative Game Approach to Optimal Merging Sequence and On-Ramp Merging Control of Connected and Automated Vehicles

Vehicle merging is one of the main causes of reduced traffic efficiency, increased risk of collision, and fuel consumption. Connected and automated vehicles (CAVs) can improve traffic efficiency, increase safety, and reduce the negative environmental impacts through effective communication and control. Therefore, to improve the traffic efficiency and reduce the fuel consumption in on-ramp scenarios, this paper addresses the global and optimal coordination of the CAVs in a merging zone. In this work, a cooperative multi-player game-based optimization framework and an algorithm are presented to coordinate vehicles and achieve minimum values for the global pay-off conditions. Fuel consumption, passenger comfort, and travel time within the merging control zone were used as the pay-off conditions. After analyzing the characteristics of the merging control zone and selecting the appropriate control decision duration, multi-player games were decomposed into multiple two-player games. An optimal merging strategy was, thereby, derived from a pay-off matrix, and minimum payoffs were predicted for a number of different potential strategies. The optimal trajectory corresponding to the predicted minimum payoffs was then utilized as the control law to coordinate the vehicles merging. The proposed control scheme derives an optimal merging sequence and an optimal trajectory for each vehicle. The effectiveness of the proposed model is validated through simulation. Finally, the proposed controller is compared with two alternative methods to demonstrate its potential to reduce fuel consumption and travel time and to improve passenger comfort and traffic efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand Response for Thermal Fairness in District Heating Networks

District Heating (DH) networks are complex thermal grids wherein a centrally heated fluid is circulated through a network of pipes and heat exchangers to meet the heating needs of residential and commercial buildings. Several factors can lead to inefficient and unfair energy distribution among consumers in these networks. These include varying levels of building insulation, distance of individual buildings from the central energy source, and thermal losses in network pipes. Moreover, shortage of energy at the central energy source and extreme weather conditions can exacerbate these issues, leading to differing levels of thermal comfort and customer disgruntlement in the long run. In this paper, we propose and study a demand response scheme that attempts to ensure thermal fairness among energy consumers in modern thermal grids. We develop optimization formulations based on thermodynamic models of DH networks, which determine optimal energy flow for individual buildings in order to achieve thermal fairness across the network. Our experimental results using physics based models for DH networks show that it is possible to achieve network level thermal fairness based social welfare objectives by controlling network parameters such as mass flow rates of water to the consumer premises and the supply water temperature, even when some network parameters like building thermal characteristics remain unknown.

Bhattacharya, Saptarshi↗

PhaseChange Material Melting in an Energy Storage Module for a Micro Environmental ControlSystem

An experimentally validated finite element model (FEM) was developed to analyze the design parameters of a latent heat storage device (LHSD) for a micro environmental control system ( μ X). The μ X provides local cooling to an office worker in a room whose thermostat setpoint has been elevated from 23.9 °C (75 °F) to 26.1 °C (79 °F) in order to reduce heating, ventilation, and air conditioning (HVAC) energy consumption. For this application, the LHSD is designed to provide ≥50 W of cooling for a full, 8.5 h workday to restore thermal comfort in the warm, 26.1 °C room. The LHSD comprises several parallel slabs of encased phase change material (PCM) with interposed airflow channels. The airflow rate is selected to obtain ≥50 W of cooling at the end of the 8.5 h operation. The LHSD exhibits a decreasing cooling rate over the 8.5 h period when a constant airflow is passed through it, indicating that more cooling is supplied during the day than the minimum 50 W required for thermal comfort. The parametric analysis explores the effects of PCM thermal conductivity, slab thickness, air channel width, and number of slabs on LHSD performance. Parametric cases are compared against each other on the basis of their required PCM mass and energy consumption.

Engineering↗

Editorial for Special Issue: Grid-Interactive Efficient Buildings - Part 1

We are pleased to present starting with this volume of ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC), a series of peer-reviewed papers related to some of ongoing research projects and applications of Grid-interactive Efficient Buildings (GEBs). As part of a new program initiated by the Building Technology Office (BTO) with the US Department of Energy (DOE), GEBs are characterized as highly energy-efficient buildings that are equipped with smart technologies and distributed energy resources that can be dynamically controlled to meet grid needs and minimize electricity system costs, while meeting occupants’ comfort and productivity requirements. In simple terms,DOE defines GEBs as efficient, connected, smart, and flexible buildings. The GEB technologies touch on the main topical areas of JESBC aimed at fostering sustainable buildings and cities by providing results of evaluation studies and demonstration projects. Indeed, one of the main goals for JESBC is to disseminate solutions to enhance the built environment energy efficiencies, low carbon services, inter-connectivity services, resilient multi-services, and healthy and comfortable living spaces.

buildings↗

Sensitivity Analysis of Occupant Preferences on Energy Usage in Residential Buildings: Preprint

Residential buildings, accounting for 37% of the total electricity consumption in the United States, are suitable for demand-side management (DSM) programs to support effective and economical operation of the power system. A home energy management system (HEMS) enables residential buildings to participate in such programs. It is important to account for occupant preferences in HEMS to ensure occupant satisfaction while participating in DSM programs. For example, people who prefer a higher thermal comfort level are likely to consume more energy. In this study, we used foresee™, a HEMS developed by the National Renewable Energy Lab (NREL), to perform a sensitivity analysis of occupant preferences with the following objectives: minimize utility cost, minimize carbon footprint, and maximize thermal comfort. To incorporate the preferences into the HEMS, the SMARTER method was used to derive a set of weighting factors for each objective. We performed week-long building energy simulations using a model of a home in Fort Collins, Colorado, where there is mandatory time-of-use electricity rate structure. The foreseeTM HEMS was used to control the home with six different sets of occupant preferences. The study shows that occupant preferences can have a significant impact and is important to consider when modeling residential buildings. Results show that the HEMS could achieve energy reduction ranging from 3% to 21%, cost savings ranging from 5% to 24%, and carbon emission reduction ranging from 3% to 21%, while maintaining a low thermal discomfort level ranging from 0.78 K-hour to 6.47 K-hour in a one-week period during winter. These outcomes quantify the impact of varying occupant preferences and will be useful for controlling the electrical grid and developing HEMS solutions.

carbon footprint↗

SU-E-T-281: Reduction of Treatment Times in CyberKnife Prostate SBRT Using a Water Filled Rectal Balloon

Purpose: To illustrate 25% reduction in CyberKnife prostate SBRT treatment times using a water filled rectal balloon. Methods: We perform prostate SBRT using a 3800cGy in 4 fraction regimen prescribed between 51% 59% iso-dose lines to 95% of PTV using a CyberKnife System. The resultant heterogeneous dosimetry is analogous to HDR dosimetry. Our patients are treated in a feet first supine position to decrease treatment couch sag and also to position the prostate anatomy closer to the robot. CT imaging is performed with a Radiadyne Immobiloc rectal balloon filled with 45-50cc water placed firmly inside the patient's rectum. A treatment plan is developed from this CT study using Multiplan. The patient is treated every other day for 4 days using the rectal balloon for each fraction. Gold fiducials previously implanted inside the prostate are used for tracking by the CyberKnife system. Results: Critical structures comprise the usual GU anatomy of bladder, rectum, urethra, femoral-heads along with emphasis on doses to anterior rectal wall and rectal mucosa. The water filled rectal balloon localizes the rectum, which enables the physician to accurately contour both anterior rectal wall, and rectal mucosa. The balloon also has a gas release valve enabling better patient comfort. Rectum localization enables the CyberKnife system to make fewer corrections resulting in fewer treatment interruptions and time lost to re-adjustment for rectal motion, bowel filling and gas creation. Effective treatment times are reduced by 25% to approximately 45 minutes. Adoption of the balloon has required minimal change to our planning strategy and plan evaluation process. Conclusion: Patient follow-up comparisons show no difference in effectiveness of treatment with and without balloons We conclude that rectal balloons enhance patient comfort and decrease effective treatment times.

60 APPLIED LIFE SCIENCES↗

SU-C-19A-05: Treatment Chairs for Modern Radiation Therapy Treatments

Purpose: Treating patients in a seated position has potential advantages including improved comfort, increased lung volume, and reduced respiratory motion. We compared chair designs for head and neck, thoracic and breast patients for use with either IGRT linacs or a proposed low-cost fixed horizontal beam-line machine. Methods: Three treatment chairs were designed and constructed. Two of the chairs are based on a massage-chair, with the patient angled slightly forwards and knee rests used to minimize intra-fraction slouch. The third chair design is more conventional; the patient is angled backwards, with indexed positioning devices and the ability to attach thermoplastic masks. Patient geometries, including PTV location and patient sizes, were extracted from 137 CTs of past patients were used to model the probability of collision between the patient and the linac for various seated positions. All chairs were designed around the weight limits for couches on our linacs. At the time of writing we have just received IRB approval for imaging studies to evaluate comfort, and intra- and interfraction reproducibility. Results: The geometric analysis showed that head and neck patients and thoracic patients could be treated without collision. However, there is very limited space between the patient and the treatment/imaging devices, so careful design of the chair is essential. The position of the treatment target and extended arm positioning means that this is a particular concern for thoracic and breast patients. This was demonstrated for one of the prototype chairs designed for breast treatment where the arm holders would collide with the kV detector. The extra clearance of a dedicated fixed-beam linac would overcome these difficulties. Intra- and inter-fraction reproducibility results will be presented at the meeting. Conclusion: To take advantage of the clinical advantages of seated treatments, appropriate treatment chairs are needed. A dedicate fixed-beam linac may enable more options. This work was partially funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-I-57: Evaluate and Optimize PET Acquisition Overlap in 18F-FDG Oncology Wholebody PET/CT: Can We Scan PET Faster?

Purpose: The longer patient has to remain on the table during PET imaging, the higher the likelihood of motion artifacts due to patient discomfort. This study was to investigate and optimize PET acquisition overlap in 18F-FDG oncology wholebody PET/CT to speed up PET acquisition and improve patient comfort. Methods: Wholebody 18F-FDG PET/CT of phantoms, 8 pre-clinical patients (beagles) and 5 clinical oncology patients were performed in 90s/bed on a time-of-flight Gemini TF 64 system. Imaging of phantoms and beagles was acquired with reduced PET overlaps (40%, 33%, 27%, 20%, 13% and no overlap) in addition to the system default (53%). In human studies, 1 or 2 reduced overlaps from the listed options were used to acquire PET/CT sweeps right after the default standard of care imaging. Image quality was blindly reviewed using visual scoring criteria and quantitative SUV assessment. NEMA PET sensitivity was performed under different overlaps. Results: All PET exams demonstrated no significant impact on the visual grades for overlaps >20%. Blinded reviews assigned the best visual scores to PET using overlaps 53%–27%. Reducing overlap to 27% for oncology patients (12-bed) saved an average of ∼40% acquisition time (11min) compared to using the default overlap (18min). No significant SUV variances were found when reducing overlap to half of default for cerebellum, lung, heart, aorta, liver, fat, muscle, bone marrow, thighs and target lesions (p>0.05), except expected variability in urinary system. Conclusion: This study demonstrated by combined phantom, pre-clinical and clinical PET/CT scans that PET acquisition overlap in axial of today’s systems can be reduced and optimized. It showed that a reduction of PET acquisition overlap to 27% (half of system default) can be implemented to reduce table time by ∼40% to improve patient comfort and minimize potential motion artifacts, without prominently degrading image quality or compromising PET quantification.

60 APPLIED LIFE SCIENCES↗

Coordination of Behind-the-Meter Energy Storage and Building Loads: Optimization with Deep Learning Models*

With the increasing penetration of renewable energy systems and energy storage systems in buildings, it is critical to optimize system operation. In this paper, we develop an optimization strategy to minimize the operation cost as well as maintain indoor thermal comfort, for a building integrated with battery and PV. A Recurrent Neural Network (RNN) is used to predict building thermal load and zone temperatures. A black-box optimization algorithm known as nonlinear optimization by mesh adaptive direct search (NOMADS) is employed in simulation to provide look-ahead optimal battery dispatch and zone temperature set-point schedules so that the operation cost is minimized. Field data collected from a medium sized office building at Pacific Northwest National Laboratory (PNNL) integrated with Photovoltaic (PV) system model and battery storage system model is used to demonstrate the proposed methodology. Compared with rule based methods, the optimization strategy obtained a lower cost of operation while satisfying comfort constraints.

Chen, Yimin↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

Towards Off-policy Evaluation as a Prerequisite for Real-world Reinforcement Learning in Building Control

We present an initial study of off-policy evaluation (OPE), a problem prerequisite to real-world reinforcement learning (RL), in the context of building control. OPE is the problem of estimating a policy's performance without running it on the actual system, using historical data from the existing controller. It enables the control engineers to ensure a new, pretrained policy satisfies the performance requirements and safety constraints of a real-world system, prior to interacting with it. While many methods have been developed for OPE, no study has evaluated which ones are suitable for building operational data, which are generated by deterministic policies and have limited coverage of the state-action space. After reviewing existing works and their assumptions, we adopted the approximate model (AM) method. Furthermore, we used bootstrapping to quantify uncertainty and correct for bias. In a simulation study, we evaluated the proposed approach on 10 policies pretrained with imitation learning. On average, the AM method estimated the energy and comfort costs with 1.84% and 14.1% error, respectively.

Chen, B↗

Deep reinforcement learning with online data augmentation to improve sample efficiency for intelligent HVAC control

Deep Reinforcement Learning (DRL) has started showing success in real-world applications such as building energy optimization. Much of the research in this space utilized simulated environments to train RL-agent in an offline mode. Very few research have used DRL-based control in real-world systems due to two main reasons: 1) sample efficiency challenge---DRL approaches need to perform a lot of interactions with the environment to collect sufficient experiences to learn from, which is difficult in real systems, and 2) comfort or safety related constraints---user's comfort must never or at least rarely be violated. In this work, we propose a novel deep Reinforcement Learning framework with online Data Augmentation (RLDA) to address the sample efficiency challenge of real-world RL. We used a time series Generative Adversarial Network (TimeGAN) architecture as a data generator. We further evaluated the proposed RLDA framework using a case study of an intelligent HVAC control. With a ≈28% improvement in the sample efficiency, RLDA framework lays the way towards increased adoption of DRL-based intelligent control in real-world building energy management systems.

Kurte, Kuldeep↗

Poster Abstract: Leveraging Large Language Models to Reveal Interpretable Cooling Behaviors from Smart Thermostat Data

Frequent heatwaves and hot summers increasingly challenge occupant comfort, health, and energy grid stability. Addressing these challenges requires a detailed understanding of household cooling behaviors, such as thermostat adjustments and adaptive responses to extreme conditions. Traditional analyses often rely on aggregated numerical metrics that overlook subtle but important household-specific variations. In this study, we introduce a generalizable methodology that integrates large language models (LLMs) with vision capabilities to enable scalable and detailed analysis of residential thermostat data. Using Ecobee's Donate Your Data (DYD) dataset—which provides five-minute records of indoor temperatures, thermostat setpoints, and HVAC runtimes—we focus on two U.S. cities with contrasting summer climates : Austin (TX) and Phoenix (AZ). Because raw time-series data are not well suited for direct LLM analysis, we transform them into visual representations, such as daily indoor temperature trajectories and weekly runtime histograms, to better capture behavioral variations. Leveraging LLMs' visual interpretation, we extract descriptive behavioral features, including temperature preferences, time-of-day cooling orientation, anticipatory versus reactive heatwave responses, and behavioral consistency. These semantic features support unsupervised clustering to identify distinct occupant archetypes at scale, revealing differences—such as morning-centric anticipatory coolers versus households that shift toward warmer setpoints during heatwaves—that can inform demand response, resilience planning, and health-aware interventions. By converting raw numerical data into interpretable behavioral patterns, this methodology enables scalable and practical analysis of occupant behavior, supporting actionable insights for comfort, resilience, and energy management.

Nihar, Kopal↗

Hierarchical Model-Free Transactional Control of Building Loads to Support Grid Services

A transition from generation on demand to consumption on demand is one of the solutions to overcome the many limitations associated with the higher penetration of renewable energy sources. Such a transition, however, requires a considerable amount of load flexibility in the demand side. Demand response (DR) programs can reveal and utilize this demand flexibility by enabling the participation of a large number of grid-interactive efficient buildings (GEB). Existing approaches on DR require significant modelling or training efforts, are computationally expensive, and do not guarantee the satisfaction of end users. To address the aforementioned limitations, this software code considers a scalable hierarchical model-free transactional control approach that incorporates elements of virtual battery, game theory, and model-free control (MFC) mechanisms. The developed approach separates the control mechanism into upper and lower levels. The MFC modulates the flexible GEB in the lower level with guaranteed thermal comfort of end users in response to the optimal pricing and power signals determined in the upper layer using a Stackelberg game integrated with aggregate virtual battery constraints. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable even on small, embedded devices. This software code enables the use of residential and small-size commercial buildings to offer a potentially substantial source of ancillary grid services that are currently underutilized. A hierarchical, model-free transactive building control provides a smooth interface between the grid service requests of utilities and the reliable control required by participating buildings. Model-free control, which supports distributed control architecture, will be a more scalable solution that can be deployed in neighborhood-size systems as well as individual buildings. The proposed approach contributes to the body of knowledge on two main aspects. First, it couples the MFC with the game-theoretic control and proposes a scalable model-free transactive control approach. MFC does not require any modeling effort or model training for the various building loads. This is very beneficial since deriving an accurate model for every single unit participating in DR programs and obtaining all the parameters about the units (e.g., thermal coefficients, standby losses) are infeasible. Also, MFC is computationally efficient, easily deployable even on small, embedded devices, and can be implemented in real time. Second, it integrates the concept of virtual battery into DR via the Stackelberg game. The concept of virtual battery enables efficient coordination and aggregation of a large number of flexible GEB with guaranteed thermal comfort of end users.

Olama, Mohammed [Oak Ridge National Lab. (ORNL), O↗

Predictive Control of Residential Gas Storage Water Heaters [SWR-13-36]

Predictive Control of Residential Gas Storage Water Heaters provides an energy-efficient control method for residential gas storage water heaters. Predictive Control of Residential Gas Storage Water Heaters discovers users' hot water consumption patterns from historical data and automatically modulates the thermostat setpoints to conserve energy while maintaining thermal comfort. The starting time of hot water draw events is recorded and used for clustering analysis. Time intervals are generated from the clusters in which hot water draw events are more likely to occur. The setpoint is set at normal level to maintain thermal comfort, and decreased to a lower level outside these time intervals to reduce tank loss and thereby improving energy efficiency of the water heater.

Christensen, Dane↗