Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Processing CCD Images to Detect Transits of Earth-Sized Planets: Maximizing Sensitivity While Achieving Reasonable Downlink Requirements

We have performed end-to-end laboratory and numerical simulations to demonstrate the capability of differential photometry under realistic operating conditions to detect transits of Earth-sized planets orbiting solar-like stars. Data acquisition and processing were conducted using the same methods planned for the proposed Kepler Mission. These included performing aperture photometry on large-format CCD images of an artificial star fields obtained without a shutter at a readout rate of 1 megapixel/sec, detecting and removing cosmic rays from individual exposures and making the necessary corrections for nonlinearity and shutterless operation in the absence of darks. We will discuss the image processing tasks performed `on-board' the simulated spacecraft, which yielded raw photometry and ancillary data used to monitor and correct for systematic effects, and the data processing and analysis tasks conducted to obtain lightcurves from the raw data and characterize the detectability of transits. The laboratory results are discussed along with the results of a numerical simulation carried out in parallel with the laboratory simulation. These two simulations demonstrate that a system-level differential photometric precision of 10-5 on five- hour intervals can be achieved under realistic conditions.

Earth-size planets↗

Precision Beam Pointing for Laser Communication System Using a CCD-based Tracker

Spatial acquisition and precision beam pointing functions are critical to spaceborne laser communication systems. A recent system study indicated that a single high bandwidth CCD detector can be used to perform both spatial acquisition and tracking functions. Compared to previous lasercom hardware design, the arrray tracking cocept offers reduced system complexity by reducing the number of optical elements in the design.

Laser↗

Absolute measurement of the Fano factor using a Skipper-CCD

Skipper-CCD can achieve deep sub-electron readout noise making possible the absolute determination of the exact number of ionized electrons in a large range, from 0 to above 1900 electrons. In this work we present a novel technique that exploits this unique capability to allow self-calibration and the ultimate determination of silicon properties. We performed an absolute measurement of the variance and the mean number of the charge distribution produced by $^{55}$Fe X-rays, getting a Fano factor absolute measurement in Si at 123K and 5.9 keV. A value of 0.119 $\pm$ 0.002 was found and the electron-hole pair creation energy was determined to be (3.749 $\pm$ 0.001) eV. This technology opens the opportunity for direct measurements of the Fano factor at low energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as ``dark counts'': dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on the electron-hole pair creation energy and Fano factor below 150 eV from Compton scattering in a Skipper-CCD

Fully-depleted thick silicon Skipper-charge-coupled devices (Skipper-CCDs) have achieved sub-electron read-out noise and are an important technology to probe neutrino and light dark matter interactions. However, the successful search for rare neutrino or dark-matter events requires the signal and all backgrounds to be fully characterized. In particular, a measurement of the electron-hole pair creation energy below 150 eV and the Fano factor are necessary for characterizing the dark matter and neutrino signals. Moreover, photons from background radiation may Compton scatter in the silicon bulk, producing events that can mimic a dark matter or neutrino signal. We present a measurement of the Compton spectrum using a Skipper-CCD and a $^{241}$Am source. With these data, we measure the electron-hole pair-creation energy to be $\left(3.71 \pm 0.08\right)$ eV at 130 K in the energy range between 99.3 eV and 150 eV. By measuring the widths of the steps at 99.3 eV and 150 eV in the Compton spectrum, we introduce a novel technique to measure the Fano factor, setting an upper limit of 0.31 at 90% C.L. These results prove the potential of Skipper-CCDs to characterize the Compton spectrum and to measure precisely the Fano factor and electron-hole pair creation energy below 150 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $\gamma$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$$initio$ calculations originally developed for X-ray absorption spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Dark Energy Survey CCD imager design

The Dark Energy Survey is planning to use a 3 sq. deg. camera that houses a {approx} 0.5m diameter focal plane of 62 2kx4k CCDs. The camera vessel including the optical window cell, focal plate, focal plate mounts, cooling system and thermal controls is described. As part of the development of the mechanical and cooling design, a full scale prototype camera vessel has been constructed and is now being used for multi-CCD readout tests. Results from this prototype camera are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring the Flatness of Focal Plane for Very Large Mosaic CCD Camera

Large mosaic multiCCD camera is the key instrument for modern digital sky survey. DECam is an extremely red sensitive 520 Megapixel camera designed for the incoming Dark Energy Survey (DES). It is consist of sixty two 4k x 2k and twelve 2k x 2k 250-micron thick fully-depleted CCDs, with a focal plane of 44 cm in diameter and a field of view of 2.2 square degree. It will be attached to the Blanco 4-meter telescope at CTIO. The DES will cover 5000 square-degrees of the southern galactic cap in 5 color bands (g, r, i, z, Y) in 5 years starting from 2011. To achieve the science goal of constraining the Dark Energy evolution, stringent requirements are laid down for the design of DECam. Among them, the flatness of the focal plane needs to be controlled within a 60-micron envelope in order to achieve the specified PSF variation limit. It is very challenging to measure the flatness of the focal plane to such precision when it is placed in a high vacuum dewar at 173 K. We developed two image based techniques to measure the flatness of the focal plane. By imaging a regular grid of dots on the focal plane, the CCD offset along the optical axis is converted to the variation the grid spacings at different positions on the focal plane. After extracting the patterns and comparing the change in spacings, we can measure the flatness to high precision. In method 1, the regular dots are kept in high sub micron precision and cover the whole focal plane. In method 2, no high precision for the grid is required. Instead, we use a precise XY stage moves the pattern across the whole focal plane and comparing the variations of the spacing when it is imaged by different CCDs. Simulation and real measurements show that the two methods work very well for our purpose, and are in good agreement with the direct optical measurements.

43 PARTICLE ACCELERATORS↗

Design of an Event-Driven Random-Access-Windowing CCD-Based Camera

Commercially available cameras are not design for the combination of single frame and high-speed streaming digital video with real-time control of size and location of multiple regions-of-interest (ROI). A new control paradigm is defined to eliminate the tight coupling between the camera logic and the host controller. This functionality is achieved by defining the indivisible pixel read out operation on a per ROI basis with in-camera time keeping capability. This methodology provides a Random Access, Real-Time, Event-driven (RARE) camera for adaptive camera control and is will suited for target tracking applications requiring autonomous control of multiple ROI's. This methodology additionally provides for reduced ROI read out time and higher frame rates compared to the original architecture by avoiding external control intervention during the ROI read out process.

event driven↗

Scientific, Back-Illuminated CCD Development for the Transiting Exoplanet Survey Satellite

We describe the development of the fully depleted, back illuminated charge coupled devices for the Transiting Exoplanet Survey Satellite, which includes a set of four wide angle telescopes, each having a 2x2 array of CCDs. The devices are fabricated on the newly upgraded 200-mm wafer line at Lincoln Laboratory. We discuss methods used to produce the devices and present early performance results from the 100- micron thick, 15x15-microns, 2k x 4k pixel frame transfer CCDs.

quantum efficiency↗

Lateral Diffusion Estimation in Fully Depleted Thick CCD Using Flat Field Image Analysis

In thick fully depleted CCDs charge carrier transport from the back window to the gates is accompanied by charge diffusion. Lateral diffusion smooths out density variations of the incoming photon flux by redistributing charges spatially. This creates short range positive correlations in recorded amplitudes. Pixel-to-pixel amplitude variations can also be caused by pixel size and quantum efficiency variations. Pixel size variations result in short range negative correlations. Our study shows that the characteristic diffusion width can be extracted from flat field data. The study was performed on fully depleted, thick CCDs produced in a technology study for the Large Synoptic Survey Telescope (LSST). Data were taken in the laboratory at bias voltages between -5 and -40 V. To increase statistical accuracy, images taken in identical conditions were co-added after base line subtraction and master files were produced. A flat field image simulator was developed for statistical comparison of simulated and measured images. Results on diffusion, pixel response variations, data features, analysis and modeling techniques are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗