Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bypass Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The Effect of Bypass Nozzle Exit Area on Fan Aerodynamic Performance and Noise in a Model Turbofan Simulator

The design of effective new technologies to reduce aircraft propulsion noise is dependent on identifying and understanding the noise sources and noise generation mechanisms in the modern turbofan engine, as well as determining their contribution to the overall aircraft noise signature. Therefore, a comprehensive aeroacoustic wind tunnel test program was conducted called the Fan Broadband Source Diagnostic Test as part of the NASA Quiet Aircraft Technology program. The test was performed in the anechoic NASA Glenn 9- by 15-Foot Low Speed Wind Tunnel using a 1/5 scale model turbofan simulator which represented a current generation, medium pressure ratio, high bypass turbofan aircraft engine. The investigation focused on simulating in model scale only the bypass section of the turbofan engine. The test objectives were to: identify the noise sources within the model and determine their noise level; investigate several component design technologies by determining their impact on the aerodynamic and acoustic performance of the fan stage; and conduct detailed flow diagnostics within the fan flow field to characterize the physics of the noise generation mechanisms in a turbofan model. This report discusses results obtained for one aspect of the Source Diagnostic Test that investigated the effect of the bypass or fan nozzle exit area on the bypass stage aerodynamic performance, specifically the fan and outlet guide vanes or stators, as well as the farfield acoustic noise level. The aerodynamic performance, farfield acoustics, and Laser Doppler Velocimeter flow diagnostic results are presented for the fan and four different fixed-area bypass nozzle configurations. The nozzles simulated fixed engine operating lines and encompassed the fan stage operating envelope from near stall to cruise. One nozzle was selected as a baseline reference, representing the nozzle area which would achieve the design point operating conditions and fan stage performance. The total area change from the smallest to the largest nozzle was 12.9 percent of the baseline nozzle area. The results will show that there are significant changes in aerodynamic performance and farfield acoustics as the fan nozzle area is increased. The weight flow through the fan model increased between 7 and 9 percent, the fan and stage pressure dropped between 8 and 10 percent, and the adiabatic efficiency increased between 2 and 3 percent--the magnitude of the change dependent on the fan speed. Results from force balance measurements of fan and outlet guide vane thrust will show that as the nozzle exit area is increased the combined thrust of the fan and outlet guide vanes together also increases, between 2 and 3.5 percent, mainly due to the increase in lift from the outlet guide vanes. In terms of farfield acoustics, the overall sound power level produced by the fan stage dropped nearly linearly between 1 dB at takeoff condition and 3.5 dB at approach condition, mainly due to a decrease in the broadband noise levels. Finally, fan swirl angle survey and Laser Doppler Velocimeter mean velocity and turbulence data obtained in the fan wake will show that the swirl angles and turbulence levels within the wake decrease as the fan nozzle area increases, which helps to explain the drop in the fan broadband noise at all fan speeds.

Hughes, Christopher E.↗

Turbopump radial and axial rotor support system

Design of thrust balancer minimizes leakage bypass and obviates need for conventional thrust balancer. System allows operation at low flow rates and high thrust capacity at cryogenic temperatures and high pressures.

Buckmann, P. S.↗

Fluctuating pressures on fan blades of a turbofan engine: Static and wind-tunnel investigations

To investigate the fan noise generated from turbofan engines, miniature pressure transducers were used to measure the fluctuating pressure on the fan blades of a JT15D engine. Tests were conducted with the engine operating on an outdoor test stand and in a wind tunnel. It was found that a potential flow interaction between the fan blades and six, large support struts in the bypass duct is a dominant noise source in the JT15D engine. Effects of varying fan speed and the forward speed on the blade pressure are also presented.

Schoenster, J. A.↗

Control of Inflow Distortion in a Scarf Inlet

The scarf inlet has the potential to reduce aircraft inlet noise radiation to the ground by reflecting it into the space above the engine. Without forward motion of the engine, the non-symmetry of the inlet causes inflow distortion which generates noise that is greater than the noise reduction of the scarf. However, acoustic evaluations of aircraft engines are often done on static test stands. A method to reduce inflow distortion by boundary layer suction is proposed and evaluated using a model of a high bypass ratio engine located in an anechoic chamber. The design goal of the flow control system is to make the inflow to the inlet circumferentially uniform and to eliminate reversed flow. This minimizes the inflow distortion and allows for acoustic evaluation of the scarf inlet on a static test stand. The inlet boundary layer suction effectiveness is evaluated both by aerodynamic and by acoustic measurements. Although the design goal is not met, the control system is found to have a beneficial effect on the engine operation, reducing blade stall and speed variation. This is quantified by two acoustic benefits, reduction both of the variability of tone noise and of the low frequency wideband noise due to the inflow distortion. It is felt that a compromise in the manufacture of the control hardware contributes to the inability of the control system to perform as expected from the analysis. The control system with sufficient authority is felt to have the potential to permit reliable acoustic testing in a static configuration of engines with non-symmetric inlets. Because the control system can improve operation of the engine, it may also have the potential to reduce noise and vibration and enhance engine longevity during low speed ground operations in the terminal area.

Gerhold, Carl H.↗

Fan inlet for a V/STOL airplane

An inlet was designed for a tilt nacelle lift/cruise fan. A complete set of low speed data was obtained with a 38-cm diameter cold-flow model, and a partial set of data was obtained with a 140-cm-diameter inlet coupled to a high bypass turbofan. The results indicate that a fixed-geometry inlet is a viable concept for the proposed application. Analyses of the data demonstrate that at high angles of incidence and at low airflow rates inlet-flow separation is strongly sensitive to Reynolds number and, consequently, the large-scale inlet has a significantly greater range of separation-free operation.

Koncsek, J. L.↗

Plug20 Test Report: Particle Image Velocimetry (PIV) Measurements

This report provides turbulent flow statistics made using particle image velocimetry (PIV) for several internally mixed exhaust systems with external plugs (Plug20 designs). The tests were conducted at the NASA Glenn Research Center’s Aero-Acoustic Propulsion Laboratory (AAPL) in May and June 2022. The corresponding acoustic data for the configurations and flows presented in this report can be found in an earlier Technical Memorandum, NASA/TM-20210010291, “Plug20 Test Report.” The Plug20 nozzle family was designed to represent commercial supersonic vehicles in the 2025 to 2035 timeframe with a bypass ratio around 4, having an internal mixer, with and without an external plug to improve nacelle boattail drag and shock. The flow conditions measured represent engine cycles for commercial supersonic aircraft at takeoff, having pressure ratios of 2.0 and heated fan and core streams, measured both with and without a flight stream surrounding the plume. A few unheated flow conditions were also tested to tie results to other baseline test results. The PIV measurements in both streamwise and cross-stream planes are described, along with brief analysis to visually catalog the contents and confirm their validity. In this analysis, the streamwise PIV is found to match benchmark datasets within its experimental error. However, the cross-stream turbulent quantities measured by two systems do not match each other or the streamwise measurements in amplitude—caution is required when using the cross-stream data. Data acquired and included in this report are (1) velocity statistics of the plumes in both a streamwise and several cross-stream planes, and (2) the hot nozzle geometry. Tabular forms of the data and computer-aided design (CAD) files of the hot geometry are presented as supplemental files described in Appendix A (TM-20230006779SUPPL1.zip) and Appendix B (TM-20230006779SUPPL2.zip).

Turbulence↗

Flow Fields of Internally Mixed Exhaust Systems With External Plug For Supersonic Transport Applications

Commercial supersonic vehicles of the future will likely use engines with lower bypass ratios, where the design of the internal mixer will have a strong impact on the noise produced by the jet plume. Their exhaust systems may also feature external plugs to improve boattail angle for cruise performance at supersonic speeds. Currently there are no publicly available empirical noise models for such nozzle systems, and insight into their flow fields will help in creating these models. For those attempting to make large eddy simulations and other higher fidelity methods be their main prediction tool, the internally mixed exhaust system is also a good test case when going beyond simple single-stream jets. The turbulent flow statistics of several configurations previously tested for noise and shocks have been measured for flow conditions that can be used in development of empirical models and validating scale-resolving prediction tools. These measurements are presented and briefly analyzed for insights into the noise impacts from the flow impacts observed.

Turbulence, Jets, Particle Image velocimetry↗

Flow Fields of Internally Mixed Exhaust Systems With External Plug For Supersonic Transport Applications

Commercial supersonic vehicles of the future will likely use engines with lower bypass ratios, where the design of the internal mixer will have a strong impact on the noise produced by the jet plume. Their exhaust systems may also feature external plugs to improve boattail angle for cruise performance at supersonic speeds. Currently there are no publicly available empirical noise models for such nozzle systems, and insight into their flow fields will help in creating these models. For those attempting to make large eddy simulations and other higher fidelity methods be their main prediction tool, the internally mixed exhaust system is also a good test case when going beyond simple single-stream jets. The turbulent flow statistics of several configurations previously tested for noise and shocks have been measured for flow conditions that can be used in development of empirical models and validating scale-resolving prediction tools. These measurements are presented and briefly analyzed for insights into the noise impacts from the flow impacts observed.

Fluid Mechanics and Thermodynamics↗

Calculation of the longitudinal aerodynamic characteristics of STOL aircraft with externally-blown jet-augmented flaps

A theoretical investigation was made to develop methods for predicting the longitudinal aerodynamic characteristics of externally-blown, jet-augmented wing-flap combinations. A potential flow analysis was used to develop two models: a wing-flap lifting surface model and a high-bypass-ratio turbofan engine wake model. Use of these two models in sequence provides for calculation of the wing-flap load distribution including the influence of the engine wake. The method can accommodate multiple engines per wing panel and part-span flaps but is limited to the case where the flow and geometry of the configuration are symmetric about a vertical plane containing the wing root chord. Comparisons of predicted and measured lift and pitching moment on unswept and swept wings with one and two engines per panel and with various flap deflection angles indicate satisfactory prediction of lift and moment for flap deflections up to 30 to 40 degrees. At higher flap angles with and without power, the method begins to overpredict lift, due probably to the appearance of flow separation on the flaps.

Dillenius, M. F. E.↗

Disastrous Portal Vein Embolization Turned into a Successful Intervention

Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technology outlook for aviation

Growth projections for aviation technology are put forth for a quarter-century ahead. Three main trends envisaged are towards: great efficiency and economy and longer range and endurance for subsonic aircraft; new generations of short-range fixed-wing craft and rotorcraft with versatile applicability; supersonic and hypersonic speeds. Improvements in lift/drag ratio, specific fuel consumption, structural weight factor, aerodynamic improvements (laminar flow control, increased wing aspect ratio, drag reduction for specified lift, propulsion efficiency, higher bypass ratios, composite structures) are discussed along with V/STOL, controllable twist rotors, circulation control rotors, variable-cycle engines, and higher structural efficiencies.

Roberts, L.↗

Independent Orbiter Assessment (IOA): Analysis of the elevon subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results for the Orbiter Elevon system hardware. The elevon actuators are located at the trailing edge of the wing surface. The proper function of the elevons is essential during the dynamic flight phases of ascent and entry. In the ascent phase of flight, the elevons are used for relieving high wing loads. For entry, the elevons are used to pitch and roll the vehicle. Specifically, the elevon system hardware comprises the following components: flow cutoff valve; switching valve; electro-hydraulic (EH) servoactuator; secondary delta pressure transducer; bypass valve; power valve; power valve check valve; primary actuator; primary delta pressure transducer; and primary actuator position transducer. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Of the 25 failure modes analyzed, 18 were determined to be PCIs.

Wilson, R. E.↗

Bypass transition in boundary layers including curvature and favorable pressure gradient effects

Recent studies of 2-D boundary layers undergoing bypass transition were reviewed. Bypass transition is characterized by the sudden appearance of turbulent spots in boundary layer without first the regular, observable growth of disturbances predicted by linear stability theory. There are no standard criteria or parameters for defining bypass transition, but it is known to be the mode of transition when the flow is disturbed by perturbations of sufficient amplitude.

Volino, R. J.↗

Numerical simulation of instability and transition physics

The study deals with the algorithm technology used in instability and transition simulations. Discretization methods are outlined, and attention is focused on high-order finite-difference methods and high-order centered-difference formulas. One advantage of finite-difference methods over spectral methods is thought to be in implementation of nonrigorous boundary conditions. It is suggested that the next significant advances in the understanding of transition physics and the ability to predict transition will come with more physically-realistic simulations. Compressible-flow algorithms are discussed, and it is noted that with further development, exploration of bypass mechanism on simple bodies at high speed would be possible.

Streett, C. L.↗

Control Valve Trajectories for SOFC Hybrid System Startup

Control and management of cathode airflow in a solid oxide fuel cell gas turbine hybrid power system was analyzed using the Hybrid Performance (HyPer) hardware simulation at the National Energy Technology (NETL), U.S. Department of Energy. This work delves into previously unexplored operating practices for HyPer, via simultaneous manipulation of bypass valves and the electric load on the generator. The work is preparatory to the development of a Multi-Input, Multi-Output (MIMO) controller for HyPer. A factorial design of experiments was conducted to acquire data for 81 different combinations of the manipulated variables, which consisted of three air flow control valves and the electric load on the turbine generator. From this data the response surface for the cathode airflow with respect to bypass valve positions was analyzed. Of particular interest is the control of airflow through the cathode during system startup and during large load swings. This paper presents an algorithm for controlling air mass flow through the cathode based on a modification of the steepest ascent method.

30 DIRECT ENERGY CONVERSION↗

Preliminary design study of advanced multistage axial flow core compressors

A preliminary design study was conducted to identify an advanced core compressor for use in new high-bypass-ratio turbofan engines to be introduced into commercial service in the 1980's. An evaluation of anticipated compressor and related component 1985 state-of-the-art technology was conducted. A parametric screening study covering a large number of compressor designs was conducted to determine the influence of the major compressor design features on efficiency, weight, cost, blade life, aircraft direct operating cost, and fuel usage. The trends observed in the parametric screening study were used to develop three high-efficiency, high-economic-payoff compressor designs. These three compressors were studied in greater detail to better evaluate their aerodynamic and mechanical feasibility.

Wisler, D. C.↗

Evaluation of two-equation turbulence models for predicting transitional flows

An evaluation of the capabilities and limitations of four low-Reynolds number two-equation turbulence models for predicting bypass transition on a flat plate has been conducted. The ability of these models to reproduce the effect of the free-stream turbulence on transition was tested. The strengths and deficiencies of these models have been identified systematically. It is found that the k-epsilon models are capable of predicting the qualitative aspects of transition. However, the predictions are found to be sensitive to the initial conditions. Also, the start and end of transition were found to depend on the damping functions used in the low-Reynolds number versions of the k-epsilon models.

Abid, Ridha↗

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗