At least 415 records · Page 23

Isolated Building Wake Experiment At Texas Tech University’s Wind Engineering Research Field Lab

Texas Tech University’s (TTU’s) Wind Engineering Research Field Lab (WERFL) building is an idealized rectangular building on the scale of a typical suburban house. It is surrounded almost entirely by unobstructed planes and is built on a turn table. WERFL is ideal for providing measurements of an idealized building under real-world conditions including atmospheric stability and variable relative wind angles. The intent of this data set is for verification and validation of computational fluid dynamics model simulations of flow around buildings. The primary focus of this dataset features 24 3D sonic anemometers (20 downwind and 4 upwind) and 10 2D sonic anemometers (9 downwind and 1 upwind) located in the immediate vicinity of the WERFL building. It also includes a variety of instruments intended to measure the ambient meteorological parameters and the undisturbed wind profile.

17 WIND ENERGY↗

Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Machine Learning Techniques to an Agent-Based Model of Pantoea

Agent-based modeling (ABM) is a powerful simulation technique which describes a complex dynamic system based on its interacting constituent entities. While the flexibility of ABM enables broad application, the complexity of real-world models demands intensive computing resources and computational time; however, a metamodel may be constructed to gain insight at less computational expense. Here, we developed a model in NetLogo to describe the growth of a microbial population consisting of Pantoea . We applied 13 parameters that defined the model and actively changed seven of the parameters to modulate the evolution of the population curve in response to these changes. We efficiently performed more than 3,000 simulations using a Python wrapper, NL4Py . Upon evaluation of the correlation between the active parameters and outputs by random forest regression, we found that the parameters which define the depth of medium and glucose concentration affect the population curves significantly. Subsequently, we constructed a metamodel, a dense neural network, to predict the simulation outputs from the active parameters and found that it achieves high prediction accuracy, reaching an R 2 coefficient of determination value up to 0.92. Our approach of using a combination of ABM with random forest regression and neural network reduces the number of required ABM simulations. The simplified and refined metamodels may provide insights into the complex dynamic system before their transition to more sophisticated models that run on high-performance computing systems. The ultimate goal is to build a bridge between simulation and experiment, allowing model validation by comparing the simulated data to experimental data in microbiology.

59 BASIC BIOLOGICAL SCIENCES↗

Floating Block Method for Quantum Monte Carlo Simulations

Quantum Monte Carlo simulations are powerful and versatile tools for the quantum many-body problem. In addition to the usual calculations of energies and eigenstate observables, quantum Monte Carlo simulations can in principle be used to build fast and accurate many-body emulators using eigenvector continuation or design time-dependent Hamiltonians for adiabatic quantum computing. Furthermore, these new applications require something that is missing from the published literature, an efficient quantum Monte Carlo scheme for computing the inner product of ground state eigenvectors corresponding to different Hamiltonians. In this work, we introduce an algorithm called the floating block method, which solves the problem by performing Euclidean time evolution with two different Hamiltonians and interleaving the corresponding time blocks. We use the floating block method and nuclear lattice simulations to build eigenvector continuation emulators for energies of 4 He, 8 Be, 12 C, and 16 O nuclei over a range of local and nonlocal interaction couplings. From the emulator data, we identify the quantum phase transition line from a Bose gas of alpha particles to a nuclear liquid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Study on Computational Cost Reduction of Simulations of Phase-Change Material (PCM) Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers (HX’s) is typically computationally intensive due to the relatively complex time-dependent physics. Most of the PCM modeling work in the literature uses high-order modeling tools such as Computational Fluid Dynamics (CFD) and Lattice-Boltzmann Method (LBM). For design purposes, the existing PCM modeling approaches are not practical, limiting researchers in their ability to investigate new ideas and different PCM’s with faster turnarounds. This paper presents a study investigating the reduction of computational cost of PCM embedded HX’s CFD models by evaluating the feasibility of spatial reduction without losing accuracy. The analysis consists of comparing full and partial domain under full melting conditions. The subject of this study is a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 35oC nominal melting temperature. Different tube and fin dimensions are investigated. Results indicate that the reduced domain reproduces - in half the run time - the same behavior as the full domain since the buoyancy effects are localized and patterned. The outputs from the partial domain simulation were used to build a non-general correlation for the PCM heat transfer characteristics and demonstrated how it can be implemented in a Finite Control Volume Reduced Order Model (ROM). The ROM can accurately reproduce the CFD simulations at 4 to 5 orders of magnitude faster.

25 ENERGY STORAGE↗

Empirical validation and comparison of methodologies to simulate micro and macro-encapsulated PCMs in the building envelope

Thermal Energy Storage (TES) has the potential to shift peak electricity demand. Passive TES is usually implemented in building envelope as micro and macro encapsulated phase change materials (PCM) to shift electric energy demand and therefore requires careful heat transfer analysis. Whole building energy modelling with simplified heat transfer analysis has become extremely important for designers, architects, engineers, and researchers to predict energy performance of buildings. It is important to validate PCM modelling algorithms used in building energy programs to quantify their error and prove their capacity to model different PCM encapsulation types. This study uses data from a microencapsulated PCM and two macroencapsulated PCMs (Bio based PCM and hydrate salts) tested in full-scale using the Advanced Multiscale Building Energy Research (AMBER) Lab located at the Colorado School of Mines and is used to validate a numerical algorithm written in MATLAB language. To approximate the heat transfer through a wall assembly with macroencapsulated PCM pouches, several modelling techniques that can reduce 3D heat transfer characteristics to 1D are explored in this research. A parallel path heat transfer modelling approach is found to give the closest agreement with the experimental data for the pouched PCMs in building envelope applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling Efficient Surveillance, Control, and Automation of Geothermal Operations with Advanced Predictive Analytics

Automation and control of geothermal energy production and operations require reliable and efficient predictive tools. While physics-based simulation offers a comprehensive tool for predicting energy production performance in geothermal systems, predicting the behavior of geothermal reservoirs involves complex multi-physics processes with coupling effects, highly uncertain input parameters and subsurface descriptions. Moreover, building, running, and integrating simulation models into standard model calibration and optimization workflows entail significant technical and computational efforts. An emerging alternative to physics-based simulation is data-driven predictive analytics models that have gained popularity in energy industry. In this report, we develop novel predictive models for integration into real-time fault diagnosis and model predictive control algorithms to improve the efficiency of energy production operations in geothermal reservoirs. The report includes two major research Thrust Areas, that is, the surface power plant and the subsurface reservoir.

15 GEOTHERMAL ENERGY↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

BEopt™ (Building Energy Optimization Tool) version 3.0.1 3/16/2023 [SWR-05-41]

The BEopt™ (Building Energy Optimization Tool) software provides capabilities to evaluate residential building designs and identify cost-optimal efficiency packages at various levels of whole-house energy savings along the path to zero net energy. The BEopt software can be used to analyze both new construction and existing home retrofits, as well as single-family detached and multi-family buildings, through evaluation of single building designs, parametric sweeps, and cost-based optimizations. The BEopt software provides detailed simulation-based analysis based on specific house characteristics, such as size, architecture, occupancy, vintage, location, and utility rates. Discrete envelope and equipment options, reflecting realistic construction materials and practices, are evaluated. The BEopt software uses EnergyPlus®, the Department of Energy's flagship simulation engine. Simulation assumptions are based on ANSI/RESNET/ICC Standards and the Building America Housing Simulation Protocols. The sequential search optimization technique used by the BEopt software: Finds minimum-cost building designs at different target energy-savings levels Identifies multiple near-optimal designs along the path, allowing for equivalent solutions based on builder or contractor preference. Download A BEopt™ Version 3.0.1 Beta release (Mar. 16, 2023) is now available. Download the BEopt 3.0.1 Beta setup file.

Christensen, Craig↗

Development of A Hardware-In-the-Loop (HIL) Testbed for Cyber-Physical Security in Smart Buildings

As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.

Li, Guowen↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D Reality Energy Modeling Software

The team will combine Bentley Systems’ ContextCapture and extend Oak Ridge National Laboratory’s building energy modeling capabilities in order to create digital twins of buildings that allow simulation-informed improvement for energy efficiency and demand response in the design and operation of the built environment. Bentley Systems’ ContextCapture software processes data from 3D laser scanning and photographs (through photogrammetry) to create a photorealistic, 3D mesh with a scale of individual objects to building to city-sized. This capability easily provides city-level visualization models and platforms where sustainable design alternatives are readily evaluated. Oak Ridge National Laboratory (ORNL) serves the U.S. Dept. of Energy (DOE) as one of three core laboratories developing building energy modeling tools EnergyPlus and OpenStudio. ORNL’s AutoBEM software (bit.ly/AutoBEM) can process imagery (satellite, aerial, and street level), LiDAR, cartographic layers, tax assessor’s data, and other data sources to extract building footprints, height, window-to-wall ratio, building type, vintage, and other building properties. AutoBEM has created 178,368 building energy models that were empirically validated with 15-minute whole-building electrical data from a utility.

97 MATHEMATICS AND COMPUTING↗

Design and dispatch optimization of packaged ice storage systems within a connected community

The traditional implementation of cool thermal energy storage (CTES) must be reimagined within the context of a dynamic grid and smart buildings operating as connected communities. As most buildings do not operate central chillers or connect to district cooling loops, this necessitates a broader use of packaged CTES. Our objective is to begin answering the question of how such packaged CTES should be implemented within a connected community. We do so by presenting a simulation–optimization workflow employing building energy modeling software and a mixed-integer linear program to design and dispatch a packaged CTES technology to achieve minimum total annual cost. We demonstrate this methodology on a seven-building case study using current utility rates and find that total annual cooling energy costs can be reduced by 17.8% compared to baseline, after accounting for the cost of storage. We perform three parametric sensitivity studies to evaluate modeling assumptions and obtain the prioritization of storage procurement as a function of annualized life-cycle cost of storage. We find that a community optimization approach provides significantly different results than individual building optimizations and provides greater savings compared to baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity of tropical orographic precipitation to wind speed with implications for future projections

Abstract. Some of the rainiest regions on Earth lie upstream of tropical mountains, where the interaction of prevailing winds with orography produces frequent precipitating convection. Yet the response of tropical orographic precipitation to the large-scale wind and temperature variations induced by anthropogenic climate change remains largely unconstrained. Here, we quantify the sensitivity of tropical orographic precipitation to background cross-slope wind using theory, idealized simulations, and observations. We build on a recently developed theoretical framework that characterizes the orographic enhancement of seasonal mean precipitation, relative to upstream regions, as a response of convection to cooling and moistening of the lower free troposphere by stationary orographic gravity waves. Using this framework and convection-permitting simulations, we show that higher cross-slope wind speeds deepen the penetration of the cool and moist gravity wave perturbation upstream of orography, resulting in a mean rainfall increase of 20 % (m s−1)−1 to 30 % (m s−1)−1 increase in cross-slope wind speed. Additionally, we show that orographic precipitation in five tropical regions exhibits a similar dependence on changes in cross-slope wind at both seasonal and daily timescales. Given next-century changes in large-scale winds around tropical orography projected by global climate models, this strong scaling rate implies wind-induced changes in some of Earth's rainiest regions that are comparable with any produced directly by increases in global mean temperature and humidity.

Nicolas, Quentin (ORCID:000000024116973X)↗

Global-Local Policy Search and its Application in Grid-Interactive Building Control

As the buildings sector represents over 70% of the total U.S. electricity consumption, it offers a great amount of untapped demand-side resources to tackle many critical grid-side problems and improve the overall energy system's efficiency. To help make buildings grid-interactive, this paper proposes a global-local policy search method to train a reinforcement learning (RL) based controller which optimizes building operation during both normal hours and demand response (DR) events. Experiments on a simulated five-zone commercial building demonstrate that by adding a local fine-tuning stage to the evolution strategy policy training process, the control costs can be further reduced by 7.55% in unseen testing scenarios. Baseline comparison also indicates that the learned RL controller outperforms a pragmatic linear model predictive controller (MPC), while not requiring intensive online computation.

demand response↗

The Importance of Being Adaptable: An Exploration of the Power and Limitations of Domain Adaptation for Simulation-Based Inference with Galaxy Clusters

The application of deep machine learning methods in astronomy has exploded in the last decade, with new models showing remarkably improved performance on benchmark tasks. Not nearly enough attention is given to understanding the models' robustness, especially when the test data are systematically different from the training data, or "out of domain." Domain shift poses a significant challenge for simulation-based inference, where models are trained on simulated data but applied to real observational data. In this paper, we explore domain shift and test domain adaptation methods for a specific scientific case: simulation-based inference for estimating galaxy cluster masses from X-ray profiles. We build datasets to mimic simulation-based inference: a training set from the Magneticum simulation, a scatter-augmented training set to capture uncertainties in scaling relations, and a test set derived from the IllustrisTNG simulation. We demonstrate that the Test Set is out of domain in subtle ways that would be difficult to detect without careful analysis. We apply three deep learning methods: a standard neural network (NN), a neural network trained on the scatter-augmented input catalogs, and a Deep Reconstruction-Regression Network (DRRN), a semi-supervised deep model engineered to address domain shift. Although the NN improves results by 17% in the Training Data, it performs 40% worse on the out-of-domain Test Set. Surprisingly, the Scatter-Augmented Neural Network (SANN) performs similarly. While the DRRN is successful in mapping the training and Test Data onto the same latent space, it consistently underperforms compared to a straightforward Yx scaling relation. These results serve as a warning that simulation-based inference must be handled with extreme care, as subtle differences between training simulations and observational data can lead to unforeseen biases creeping into the results.

Ntampaka, Michelle [Baltimore, Space Telescope Sci↗

Considering interplay between multiple physical phenomena to elucidate single crystal-like texture, phase transformations, and mechanical behavior of directed energy deposited SS316L

A widespread implementation of large scale additive manufacturing (AM) processes, such as wire arc-directed energy deposition (WA-DED) AM can transform the current manufacturing supply chain networks. Naturally, such implementation requires control of the microstructural attributes, such as texture and phase evolution in the processed alloys. Currently, the texture evolution in fusion-based AM (F-BAM) processes is majorly rationalized by the phenomena occurring only during solidification. However, such rationalization is insufficient for understanding the evolution of primary and secondary crystallographic orientations, and consequently, fails to offer a comprehensive understanding and control of overall texture in F-BAM processed alloys. To this end, we report a single crystal (SX)-like texture in WA-DED processed SS316L for the first time. Furthermore, we assess the physical phenomena that may lead to such unique microstructural evolution during WA-DED AM. Subsequently, using microstructural characterization spanning the build height and thermomechanical simulations we investigate the effect of competitive growth and epitaxial growth occurring during solidification and thermally induced plastic deformation occurring post solidification on the overall texture of WA-DED processed SS316L. A spatial variation in solidification pathway is also established and correlated with variation in undercoolings across the build. Tensile tests revealed a strong orientation dependence of deformation mechanisms with over 110% elongation to failure of specimens deformed along <011>. Such anisotropy is rationalized using Schmid's analysis of dislocation slip and deformation twinning. Importantly, overall, the mechanisms outlined in this work will facilitate an enhanced understanding and subsequent control of texture evolution, solidification behavior and mechanical behavior of WA-DED processed steels.

36 MATERIALS SCIENCE↗

OpenStudio® HPXML workflow [SWR-25-13]

OpenStudio-HPXML allows running residential EnergyPlus™ simulations using an HPXML file for the building description. It is intended to be used by user interfaces or other automated software workflows that automatically produce the HPXML file. OpenStudio-HPXML can accommodate a wide range of different building technologies and geometries. End-to-end simulations typically run in 3-10 seconds, depending on complexity, computer platform and speed, etc. For more information on running simulations, generating HPXML files with the appropriate inputs to run EnergyPlus, etc., please visit the documentation linked below. https://openstudio-hpxml.readthedocs.io/en/latest