On-line installation of the Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap

The Cabibbo-Kobayashi-Maskawa quark mixing matrix currently does not satisfy unitarity at the 2σ-level. This could be the result of an inaccurate value of one or both of its largest matrix elements V us and V ud . In the case of V ud , the most precise measurement is obtained from the f t -value measurements of superallowed beta-transitions between 0 + states. The accuracy of this determination can, in turn, be tested by extracting V ud in other transitions including superallowed transitions between mirror nuclei. The Superallowed Transition Beta-Neutrino Decay Ion Coincidence Trap (St. Benedict) is currently under construction at the Nuclear Science Laboratory of the University of Notre Dame to perform such a determination, with the goal of shedding more light on this tension with unitarity. St. Benedict will take a radioactive ion beam produced by TwinSol , thermalize it in a large volume gas catcher, then transport it in two separate differentially-pumped volumes using a radio-frequency (RF) carpet and a radio-frequency quadrupole (RFQ) ion guide before injecting it in an RFQ trap to create cool ion bunches for injection in the measurement Paul trap. In this paper, we detail the installation of the beam preparation components of St. Benedict, and present the results of the first RIBs successfully stopped and extracted from its gas catcher.

Brodeur, M.↗

In-situ Characterizations of Microstructural Degradation of Perovskite Solar Cells

Rapid progress has been achieved in perovskite solar cells (PSCs), and their efficiencies have improved from 3.8 % to 24.2 % in less than a decade. With low-cost processing, PSCs have shown exciting photovoltaic (PV) properties, such as effective optical absorption, a long carrier lifetime, and unique defect tolerance. While recent studies demonstrated improved stability up to 100 days, PSC technology is still challenged to meet the stringent industry requirements for commercialization. Despite considerable efforts, the underlying physical mechanisms for the inferior stability of PSCs are not well understood. One reason for this divergence is that many established measurement techniques (e.g., quantum efficiency, photoluminescence) probe the properties on length scales far greater than that of electronic and/or structural inhomogeneity (i.e., < 1 μm near grain boundaries) and therefore characterize convoluted and/or averaged properties. Ion/electron beam-based techniques have been extensively used to access the microstructures of PSCs, enabling atomic/nanoscale structural, chemical, optical, and electrical characterizations. For example, focused ion beam (FIB) milling produces an atomically smooth surface that minimizes the artifacts attributed to the surface roughness. FIB techniques can also create a well-defined cross-section of PSCs without mechanical damage in a physical cleaving sample preparation. While powerful, there are some concerns about possible beam damage of inorganic-organic perovskites via chemical-bond breakage and local heating. This project aims to comprehensively understand how the microstructural/interfacial properties of PSCs (e.g., Methylammonium Lead Iodide [MAPbI 3 ]) are modified under the irradiating ion beams. Specifically, we investigate the sub-surface properties of PSCs before and after Ar-ion beam injections. Kelvin probe force microscopy (KPFM) measures the contact potential differences (CPDs). Photoluminescence (PL) microscopy in conjunction with Finite-Difference Time-Domain (FDTD) simulations infers the formation of a “dead layer” (< 15 nm) on the subsurface of MAPbI 3 during Ar+ milling processes while preserving the initial bulk properties. The x-ray photoemission spectroscopy (XPS) confirms this modified surface is a lead-rich and iodine-deficient surface. We initiate customizing in-situ measurement setup while measuring the local optical and electrical properties of PSC under thermal (cooling, heating) and light stressors. Our results provide in-depth knowledge of the ion-beam impact on metal-halide perovskites and how this modified sub-surface impacts their properties under accelerated stressors of light and heat. Intensive Monte Carlo simulations of an electron beam interacting with PSCs provide the beam energy distribution in PSCs, proposing possible measurement conditions of using e-beam with minimizing beam damage. Our in-situ measurement platform can accommodate the diverse architecture of PSC devices for studying deterioration mechanisms under mixed environmental stressors.

14 SOLAR ENERGY↗

A compact 2.5-Kelvin closed-cycle refrigerator

A helium refrigerator utilizing the Gifford-McMahon/Joule-Thomson cycle was designed and tested to demonstrate the feasibility of using small closed-cycle refrigerators as an alternative to batch filled-cryostats for operating temperatures below 4 K. The systems could be used to cool low-noise microwave maser amplifiers located in large parabolic antennas. These antennas tilt vertically, making conventional liquid-filled dewars difficult to use. The system could also be used for a nontilting beam waveguide antenna to reduce the helium consumption of a liquid helium cryostat. The prototype system is adjustable to provide 700 milliwatts of cooling at 2.5 K to 3 watts at 4.3 K. The performance of the unit is not significantly affected by operation in any physical orientation.

Britcliffe, Mike↗

Ion Generation Using Frozen Xenon Target for Laser Ion Source

A frozen laser target that is in the gaseous phase at room temperature is advantageous for a laser ion source because it can avoid the accumulation of damage from laser irradiation by regeneration of the target surface by additional gas freezing. In this study, the possibility of forming a xenon ion beam with a current sufficient for heavy-ion inertial fusion (HIF) was investigated. The relationship between the frozen target growth and resulting ion current was analyzed to determine the optimal condition of laser irradiation that ensures stable supply of ion beams for a long time. A frozen target of xenon was formed on a mount cooled to 20 K using a Gifford McMahon cryocooler, and plasma was generated using a Nd:YAG laser. Here, the results showed that it is possible to supply a sufficient ion current for application of singly charged ions as a driver for HIF. Additionally, it was indicated that the xenon responsible for forming the plasma existed only at a certain depth from the target surface. The results imply that it is possible to obtain a stable ion supply for a long time by irradiating the target with a laser after the frozen xenon grows to a sufficient thickness.

43 PARTICLE ACCELERATORS↗

Status and perspective of ICARUS at the Fermilab Short-Baseline Neutrino Program

The ICARUS collaboration has employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurements of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will jointly search for evidence of sterile neutrinos with the Short-Baseline Near Detector (SBND), within the Fermilab Short-Baseline Neutrino (SBN) program. In this presentation, preliminary technical results from the ICARUS data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and its capability to select and reconstruct neutrino events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulsed source of energetic atomic oxygen

A pulsed high flux source of nearly monoenergetic atomic oxygen was designed, built, and successfully demonstrated. Molecular oxygen at several atmospheres pressure is introduced into an evacuated supersonic expansion nozzle through a pulsed molecular beam valve. An 18 J pulsed CO2 TEA laser is focused to intensities greater than 10(9) W/sq cm in the nozzle throat to generate a laser-induced breakdown. The resulting plasma is heated in excess of 20,000 K by a laser supported detonation wave, and then rapidly expands and cools. Nozzle geometry confines the expansion to provide rapid electron-ion recombination into atomic oxygen. Average O atom beam velocities from 5 to 13 km/s were measured at estimated fluxes to 10(18) atoms per pulse. Preliminary materials testing has produced the same surface oxygen enrichment in polyethylene samples as obtained on the STS-8 mission. Scanning electron microscope examinations of irradiated polymer surfaces reveal an erosion morphology similar to that obtained in low Earth orbit, with an estimated mass removal rate of approx. 10(-24) cu cm/atom. The characteristics of the O atom source and the results of some preliminary materials testing studies are reviewed.

Caledonia, George E.↗

MHD modeling of shattered pellet injection in JET

Abstract Nonlinear 3D MHD simulations of shattered-pellet injection (SPI) in JET show prototypical SPI-driven disruptions using the M3D-C1 and NIMROD extended-MHD codes. Initially, radiation-driven thermal quenches are accelerated by MHD activity as the pellet crosses rational surfaces, leading to a radiation spike, global stochasticization of the magnetic field, and a complete thermal quench. Eventually, current quenches, preceded by a current spike are seen as the Ohmic heating becomes equal to the radiative cooling. The results are qualitatively similar for both a single monolithic pellet, pencil-beam model, and a realistic shatter to represent the SPI plume. A scan in viscosity from 500 to 2000 m 2 s −1 for MHD simulations finds that reducing viscosity increases MHD activity and decreases thermal quench time slightly. A realistic cloud of fragments modeling shows that mixed-D–Ne pellet travels deeper into the plasma core before the thermal quench. At the slow pellet speeds, the pellet is found to be moving slowly enough inward that even the 5% neon in the mixed pellet is enough to effectively radiate the thermal energy available. Radiation toroidal peaking is predicted to be at levels consistent with experimental observations and reduced as the pellet travels deeper into the plasma. These simulations lay the ground work for more-sophisticated validative and predictive modeling of SPI in JET using both M3D-C1 and NIMROD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Limit on Tensor Currents in the Weak Interaction from Li 8 β Decay

Here, the electroweak interaction in the standard model is described by a pure vector-axial-vector structure, though any Lorentz-invariant component could contribute. In this Letter, we present the most precise measurement of tensor currents in the low-energy regime by examining the $β-\bar{ν}$ correlation of trapped 8 Li ions with the Beta-decay Paul Trap. We find $a_{β\barν}$ = - 0.3325 ± 0.0013 stat ± 0.0019 syst at 1σ for the case of coupling to right-handed neutrinos (C T = -C$^{'}_{T}$), which is consistent with the standard model prediction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ICARUS at the Fermilab Short-Baseline Neutrino program: initial operation

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu _e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV$^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICARUS at the Short-Baseline Neutrino program: first results

The ICARUS collaboration employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu_e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 $eV^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections in LAr with the NuMI beam and several Beyond Standard Model studies. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this presentation, preliminary results from the ICARUS data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

Artero Pons, Maria↗

Light-intensity modulator withstands high heat fluxes

Mechanism modulates and controls the intensity of luminous radiation in light beams associated with high-intensity heat flux. This modulator incorporates two fluid-cooled, externally grooved, contracting metal cylinders which when rotated about their longitudinal axes present a circular aperture of varying size depending on the degree of rotation.

Maples, H. G.↗

Cracking of a layered medium on an elastic foundation under thermal shock

The cladded pressure vessel under thermal shock conditions which is simulated by using two simpler models was studied. The first model (Model 1) assumes that, if the crack size is very small compared to the vessel thickness, the problem can be treated as a semi-infinite elastic medium bonded to a very thin layer of different material. However, if the crack size is of the same order as the vessel thickness, the curvature effects may not be negligible. In this case it is assumed that the relatively thin walled hollow cylinder with cladding can be treated as a composite beam on an elastic foundation (Model 2). In both models, the effect of surface cooling rate is studied by assuming the temperature boundary condition to be a ramp function. The calculated results include the transient temperature, thermal stresses in the uncracked medium and stress intensity factors which are presented as a function of time, and the duration of cooling ramp. The stress intensity factors are also presented as a function of the size and the location of the crack. The problem is solved for two bonded materials of different thermal and mechanical properties. The mathematical formulation results in two singular integral equations which are solved numerically. The results are given for two material pairs, namely an austenitic steel layer welded on a ferritic steel substrate, and a ceramic coating on ferritic steel. In the case of the yielded clad, the stress intensity factors for a crack under the clad are determined by using a plastic strip model and are compared with elastic clad results.

Rizk, Abd El-Fattah A.↗

Micro-optics technology and sensor systems applications

The current generation of electro-optical sensors utilizing refractive and reflective optical elements require sophisticated, complex, and expensive designs. Advanced-technology-based electro-optical sensors of minimum size and weight require miniaturization of optical, electrical, and mechanical devices with an increasing trend toward integration of various components. Micro-optics technology has the potential in a number of areas to simplify optical design with improved performance. This includes internally cooled apertures, hybrid optical design, microlenses, dispersive multicolor microlenses, active dither, electronically controlled optical beam steer, and microscopic integration of micro-optics, detectors, and signal processing layers. This paper describes our approach to the development of micro-optics technology with our main emphasis for sensors applications.

Gal, George↗

Comparison of elastic and elastic-plastic structural analyses for cooled turbine blade airfoils

Elastic plastic stress strain states in cooled turbine blade airfoils were calculated by three methods for the initial takeoff transient of an advanced technology aircraft engine. The three analytical methods compared were a three dimensional elastic plastic, finite element analysis, a three dimensional, elastic, finite element analysis, and a one dimensional, elastic plastic, beam theory analysis. Structural analyses were performed for eight cases involving different combinations of mechanical and thermal loading on impingement cooled airfoils with and without leading edge film cooling holes. The von Mises effective total strains at maximum takeoff computed from the elastic and elastic plastic finite element analyses agreed with 9 percent for rotating airfoils and 28 percent for stationary airfoils with the elastic results on the conservative side.

Kaufman, A.↗

A closed-cycle refrigerator for cooling maser amplifiers below 4 Kelvin

A helium refrigerator utilizing the Gifford-McMahon/Joule-Thomson (GM/JT) cycle was designed and tested to demonstrate the feasibility of using small closed-cycle refrigerators as an alternative to batch-filled cryostats for operating temperatures below 4 K. The systems could be used to cool low-noise microwave maser amplifiers located in large parabolic antennas. These antennas tilt vertically, making conventional liquid-filled dewars difficult to use. The system could also be used for a non-tilting beam waveguide antenna to reduce the helium consumption of a liquid helium cryostat. The prototype system is adjustable to provide 700 mW of cooling at 2.5 K to 3 W at 4.3 K. Performance of the unit is not significantly affected by physical orientation. The volume occupied by the refrigerator is less than 0.1 cu m. Two JT expansion stages are used to maximize cooling capacity per unit mass flow. The heat exchangers were designed to produce minimum pressure drop in the return gas stream. Pressure drop for the entire JT return circuit is less than 5 kpa at a mass flow of 0.06 g/sec when operating at 2.5 K.

Britcliffe, M.↗

High-resolution infrared spectroscopy of jet cooled CH 2 Br radicals: The symmetric CH stretch manifold and absence of nuclear spin cooling

Direct laser absorption of a slit supersonic discharge expansion provides the first high-resolution spectroscopic results on the symmetric CH stretch excitation (ν 1 ) of the bromomethyl (CH 2 Br) radical in the ground electronic state. Narrowband (<1 MHz) mid-infrared radiation is produced by difference-frequency generation of two visible laser beams, with the open shell halohydrocarbon radical generated by electron dissociative attachment of CH 2 Br 2 in a discharge and rapidly cooled to T rot = 18 ± 1 K in the subsequent slit-jet supersonic expansion. A rovibrational structure in the radical spectrum is fully resolved, as well as additional splittings due to spin-rotation effects and 79 Br/ 81 Br isotopologues in natural abundance. Spectroscopic constants and band origins are determined by fitting the transition frequencies to a non-rigid Watson Hamiltonian, yielding results consistent with a vibrationally averaged planar radical and an unpaired electron in the out-of-plane p π orbital. Additionally, extensive satellite band structure from a vibrational hot band is observed and analyzed. The hot band data is compared to CFOUR/VPT2 (CCSD(T)cc-pVQZ) ab initio anharmonic predictions of the vibration rotation alpha matrix, which permits unambiguous assignment to CH 2 symmetric-stretch excitation built on the singly excited CH 2 out-of-plane bending mode (ν 1 + ν 4 ← ν 4 ). Longitudinal cooling of the Doppler width in the slit-jet expansion geometry also reveals partially resolved hyperfine structure on transitions out of the lowest angular momentum states in excellent agreement with predictions based on microwave studies. High level ab initio MOLPRO calculations [CCSD(T)-f12b/VnZ-f12 (n = 3, 4, CBS)] are also performed with explicitly correlated f12 electron methods for the out-of-plane CH 2 bending mode over the halogen series CH 2 X (X = F, Cl, Br, I), which clearly reveals a non-planar geometry for X = F (with a ΔE ≈ 0.3 kcal/mol barrier) and yet planar equilibrium geometries for X = Cl, Br, and I. Finally, a detailed Boltzmann analysis of the transition intensities provides support for negligible collisional equilibration of the entangled H atom nuclear spin states on the few hundred microsecond time scale and high collision densities of a slit supersonic expansion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NASA/USRA advanced space design program: The laser powered interorbital vehicle

A preliminary design is presented for a low-thrust Laser Powered Interorbital Vehicle (LPIV) intended for cargo transportation between an earth space station and a lunar base. The LPIV receives its power from two iodide laser stations, one orbiting the earth and the other located on the surface of the moon. The selected mission utilizes a spiral trajectory, characteristic of a low-thrust spacecraft, requiring 8 days for a lunar rendezvous and an additional 9 days for return. The ship's configuration consists primarily of an optical train, two hydrogen plasma engines, a 37.1 m box beam truss, a payload module, and fuel tanks. The total mass of the vehicle fully loaded is 63300 kg. A single plasma, regeneratively cooled engine design is incorporated into the two 500 N engines. These are connected to the spacecraft by turntables which allow the vehicle to thrust tangentially to the flight path. Proper collection and transmission of the laser beam to the thrust chambers is provided through the optical train. This system consists of the 23 m diameter primary mirror, a convex parabolic secondary mirror, a beam splitter and two concave parabolic tertiary mirrors. The payload bay is capable of carrying 18000 kg of cargo. The module is located opposite the primary mirror on the main truss. Fuel tanks carrying a maximum of 35000 kg of liquid hydrogen are fastened to tracks which allow the tanks to be moved perpendicular to the main truss. This capability is required to prevent the center of mass from moving out of the thrust vector line. The laser beam is located and tracked by means of an acquisition, pointing and tracking system which can be locked onto the space-based laser station. Correct orientation of the spacecraft with the laser beam is maintained by control moment gyros and reaction control rockets. Additionally an aerobrake configuration was designed to provide the option of using the atmospheric drag in place of propulsion for a return trajectory.

Source record↗

Status and perspectives of the ICARUS experiment at the Fermilab Short Baseline Neutrino program

In this study, the ICARUS collaboration has employed the 760 t T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous ν e appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around Δm 2 ~ 1 eV 2 . After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid Argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor. ICARUS will also jointly search for evidence of sterile neutrinos together with the Short-Baseline Near Detector, within the Fermilab Short-Baseline Neutrino program experiment, and will perform measurements of neutrino cross sections with both beams and several Beyond Standard Model searches with the NuMI beam. In this paper, the main technical achievements of the ICARUS detector subsystems (Time Projection Chambers, Light Detection System, Cosmic Ray Tagger, Trigger and Data Acquisition) obtained with both BNB and NuMI neutrino beams during the commissioning phase, will be presented in terms of the overall detector performance and capability to select and reconstruct neutrino events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗