Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of variable sizes are recommended for patients with a less spacious vaginal cavity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contura Multi-Lumen Balloon Breast Brachytherapy Catheter: Comparative Dosimetric Findings of a Phase 4 Trial

Purpose: Final dosimetric findings of a completed, multi-institutional phase 4 registry trial using the Contura Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) in patients with early-stage breast cancer are presented. Methods and Materials: Three dosimetric plans with identical target coverage were generated for each patient for comparison: multilumen multidwell (MLMD); central-lumen multidwell (CLMD); and central-lumen single-dwell (CLSD) loading of the Contura catheter. For this study, a successful treatment plan achieved ideal dosimetric goals and included the following: ≥95% of the prescribed dose (PD) covering ≥95% of the target volume (TV); maximum skin dose ≤125% of the PD; maximum rib dose ≤145% of the PD; and V150 ≤50 cc and V200 ≤10 cc. Results: Between January 2008 and February 2011, 23 institutions participated. A total of 318 patients were available for dosimetric review. Using the Contura MLB, all dosimetric criteria were met in 78.93% of cases planned with MLMD versus 55.38% with the CLMD versus 37.66% with the CLSD (P≤.0001). Evaluating all patients with the full range of skin to balloon distance represented, median maximum skin dose was reduced by 12% and median maximum rib dose by 13.9% when using MLMD-based dosimetric plans compared to CLSD. The dosimetric benefit of MLMD was further demonstrated in the subgroup of patients where skin thickness was <5 mm, where MLMD use allowed a 38% reduction in median maximum skin dose over CLSD. For patients with rib distance <5 mm, the median maximum rib dose reduction was 27%. Conclusions: Use of the Contura MLB catheter produced statistically significant improvements in dosimetric capabilities between CLSD and CLMD treatments. This device approach demonstrates the ability not only to overcome the barriers of limited skin thickness and close rib proximity, but to consistently achieve a higher standard of dosimetric planning goals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic Waves From a Distant Explosion Recorded on a Continuously Ascending Balloon in the Middle Stratosphere

Abstract A helium‐filled mylar balloon carrying a smartphone and infrasound sensors ascended to a stratospheric height of 35 km over the surface detonation of a chemical explosive, with a total acoustic propagation distance of 127 km. The smartphone was configured to collect multi‐modal data at high rates from internal sensors. Analysis of the data shows successful collection of the explosion signal by both the smartphone's microphone and its accelerometers, the first from an ascending balloon. Comparison of the acoustic signal with that collected by other infrasound sensors, both airborne and ground‐based, provides insight into the possibilities and limitations of collecting acoustic data from the stratosphere.

47 OTHER INSTRUMENTATION↗

Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy

Developing advanced surgical tools for minimally invasive procedures represents an activity of central importance to improving human health. A key challenge is in establishing biocompatible interfaces between the classes of semiconductor device and sensor technologies that might be most useful in this context and the soft, curvilinear surfaces of the body. Furthermore, this paper describes a solution based on materials that integrate directly with the thin elastic membranes of otherwise conventional balloon catheters, to provide diverse, multimodal functionality suitable for clinical use. As examples, we present sensors for measuring temperature, flow, tactile, optical and electrophysiological data, together with radiofrequency electrodes for controlled, local ablation of tissue. Use of such ‘instrumented’ balloon catheters in live animal models illustrates their operation, as well as their specific utility in cardiac ablation therapy. The same concepts can be applied to other substrates of interest, such as surgical gloves.

36 MATERIALS SCIENCE↗

Three-dimensional geometry of magnetic reconnection induced by ballooning instability in a generalized Harris sheet

We report for the first time the intrinsically three-dimensional (3D) geometry of the magnetic reconnection process induced by ballooning instability in a generalized Harris sheet. Furthermore, the spatial distribution and the structure of the quasi-separatrix layers, as well as their temporal emergence and evolution, indicate that the associated magnetic reconnection can only occur in a 3D geometry, which is irreducible to that of any two-dimensional reconnection process. Such a finding provides a new perspective to the long-standing controversy over the substorm onset problem and elucidates the combined roles of reconnection and ballooning instabilities. It also connects to the universal presence of 3D reconnection processes previously discovered in various natural and laboratory plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The two-dimensional kinetic ballooning theory for trapped electron mode in tokamak

The two-dimensional (2D) kinetic theory for a collisionless trapped electron mode is developed based on the Fourier-ballooning transform in an up-down symmetric equilibrium (illustrated via concentric circular magnetic surfaces). The system consists of two equations: the ballooning (integral) equation with a parameterized Floquet phase and a second order differential equation for the distribution of the Floquet phase. The coupled equations are, then, numerically solved as an eigenvalue problem yielding the 2D mode structure (in real space) as well as the global (phase-independent) eigenvalue for an L-mode parameter set. The 2D mode structure exhibits apparent radial-poloidal asymmetry; due to the poloidal coupling, the radial correlation length is found to be, at least, twice as large as the poloidal one. The global (phase-independent) eigenvalue of the mode differs considerably from the conventional local (phase-dependent) estimate. Finally, this paper shares many technical aspects with a published paper that works out the 2D kinetic theory for the ion temperature gradient mode [Xie et al., Phys. Plasmas 24, 102506 (2017)]

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear saturation of kinetic ballooning modes by zonal fields in toroidal plasmas

Kinetic ballooning modes (KBMs) are widely believed to play a critical role in disruptive dynamics as well as turbulent transport in magnetic fusion and space plasmas. While the nonlinear evolution of the ballooning modes has been proposed as a mechanism for “detonation” in various scenarios such as the edge localized modes in tokamaks, the role of the kinetic effects in such nonlinear dynamics remains largely unexplored. In this study, global gyrokinetic simulation results of KBM nonlinear behavior are presented. Instead of the finite-time singularity predicted by ideal magnetohydrodynamic theory, the kinetic instability is shown to develop into an intermediate nonlinear regime of exponential growth, followed by a nonlinear saturation regulated by spontaneously generated zonal fields. In the intermediate nonlinear regime, rapid growth of localized current sheets, which can induce magnetic reconnection, is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On anomalous transport of multi-species plasma associated with the resistive ballooning and resistive drift waves driven turbulence

Anomalous transport of multi-species plasma related to the resistive ballooning and resistive drift wave turbulence is considered in a “cold” ion approximation. It is found that similar to the resistive drift wave turbulence [see A. R. Knyazev and S. I. Krasheninnikov, Phys. Plasmas 31, 012502 (2024); and S. I. Krasheninnikov and R. D. Smirnov, Phys. Plasmas (to be published)] the addition of the ballooning drive does not change the main features of anomalous transport of the multi-species plasma: (i) The transport of all ion species is described as a transport of the passive scalars in the turbulent field of the electrostatic potential and electron density perturbation; (ii) the density of ion species with a larger ratio of the mass to charge has the tendency to the accumulation/depletion in the vortices of plasma flow; and (iii) the cross-field transport of all plasma species (including electrons and ions) is described by the same anomalous transport coefficient.

Physics↗

Global kinetic ballooning mode simulations in BOUT++

We report on simulation results of a 3+1 gyro-Landau-fluid (GLF) model in BOUT++ framework, which contributes to increasing the physics understanding of the edge turbulence. We find that there is no second stability region of kinetic ballooning modes (KBM) in the concentric circular geometry. The first unstable β of KBM decreases below the ideal ballooning mode threshold with increasing ${{\eta}_{i}}$. In order to study the KBM in the real tokamak equilibrium, we find that the approximation of shifted circular geometry ($\beta \ll {{\varepsilon}^{2}}$ ) is not valid for a high β global equilibrium near the second stability region of KBM. Thus we generate a series of real equilibria from a global equilibrium solver CORSICA, including both Shafranov shift and elongation effects, but not including bootstrap current. In these real equilibria, the second stability region of KBM are observed in our global linear simulations. The most unstable mode for different β are the same while the mode number spectrum near the second stability region is wider than the case near the first stability region. Here, the nonlinear simulations show that the energy loss of an ELM keeps increasing with β, because the linear drive of the turbulence remains strong for the case near the second stability region during profile evolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELM-free H-mode phase and decoupling of peeling–ballooning stability boundary in the MAST Upgrade tokamak

A linear magnetohydrodynamic (MHD) peeling–ballooning stability analysis of the edge-localized mode (ELM)-free phase of a MAST Upgrade (MAST-U) H-mode plasma is presented. In contrast to other similar discharges, #47018 is found to have a significantly higher and wider pedestal during its ELM-free H-mode phase that lasts for approximately 80 ms; this is made possible by the reduced core MHD mode activity on the q = 2 surface. During this period, there is sustained decoupling of peeling and ballooning branches of the stability boundary on J–α space, opening an access channel to the second stability regime with higher peaks in pedestal current density $J_{\mathrm{N,ped}}$ and pressure gradient (α). Such decoupling of the stability boundary has not previously been observed in MAST-U H-modes, and if such a condition can be readily reproduced, it opens a wide range of opportunities for MAST-U to explore low-collisionality peeling-limited pedestal regimes as well as advanced scenarios such as quiescent H-modes that are relevant to future reactors such as STEP and ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Finite magnetic well effects on resistive and drift-resistive ballooning modes in a shaped tokamak

The impact of plasma shaping through magnetic well modifications on the stability of resistive ballooning modes (RBMs) in tokamaks is analysed, also including finite diamagnetic flows. Furthermore, various limiting cases of the dispersion relation, obtained by matching the ballooning equation across the ideal and resistive layers, are analysed. It is found that stability is generally improved by the combination of vertical elongation and positive triangularity, although, in some cases, the growth rate of the unstable mode can be enhanced by these effects. Usually, vertically elongated plasmas with no triangularity are prone to exhibit worse stability properties. A value for the critical β above which RBMs are driven unstable is identified, and a connection with type-III ELM activity is established.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic-ballooning-limited pedestals in spherical tokamak plasmas

Abstract A theoretical model is presented that for the first time matches experimental measurements of the pedestal width-height Diallo scaling in the low-aspect-ratio high- β tokamak NSTX. Combining linear gyrokinetics with self-consistent pedestal equilibrium variation, kinetic-ballooning, rather than ideal-ballooning plasma instability, is shown to limit achievable confinement in spherical tokamak pedestals. Simulations are used to find the novel Gyrokinetic Critical Pedestal constraint, which determines the steepest pressure profile a pedestal can sustain subject to gyrokinetic instability. Gyrokinetic width-height scaling expressions for NSTX pedestals with varying density and temperature profiles are obtained. These scalings for STs depart significantly from that of conventional aspect ratio tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HX-POL - A Balloon-Bourne Hard X-Ray Polarimeter

We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of dose discrepancies due to inhomogeneities and radiographic contrast in balloon catheter brachytherapy

Recently, a device called MammoSite, consisting of a balloon and a catheter, was developed to perform partial-breast irradiation using a high-dose-rate (HDR) brachytherapy unit with ease and reproducibility. However, the actual dose to the skin does not agree well with the calculated dose by the treatment planning system because of the difference between the calculation condition and the real treatment condition (i.e., homogeneous water and full scatter condition vs contrast solution and lack of full scatter condition). In this study, the authors experimentally estimated dose discrepancies due to contrast and lack of full scatter in breast HDR brachytherapy with MammoSite. Using metal-oxide-semiconductor field-effect transistor detectors and a breast phantom, the dose discrepancies between the calculation and the treatment conditions were measured according to contrast concentration (10% and 20% volume ratios), balloon size (35 and 60 cm{sup 3}), and source to detector distance ranging from 25 to 50 mm. The source was an Ir-192 isotope from Nucletron HDR unit. The dose discrepancies from the calculation condition due to both contrast and lack of full scatter combined ranged from about -1.4{+-}2.5% to -18.2{+-}2.0% in the studied cases (error bound is in two sided confidence interval of 80% based on Student's t distribution). In all cases, the effect of lack of full scatter was dominant to that of contrast and significant dose discrepancies existed between the calculation and the real treatment conditions, indicating that the actual skin dose is less than that which is currently calculated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tethered Balloon Systems

Among ARM’s aerial platforms are tethered balloon systems (TBS), which consist of a helium-filled balloon, tether, winch, and sensors. TBS provide a safe way to collect data inside clouds, including mixed-phase clouds, where icing is a concern for airborne platforms. These systems are also flown above and below clouds to gather data related to wind, turbulence, thermodynamic state, aerosols, and the cloud-top environment.

54 ENVIRONMENTAL SCIENCES↗

A tethered-balloon PTRMS sampling approach for surverying of landscape-scale biogenic VOC fluxes

To survey landscape-scale fluxes of biogenic gases, a100-meterTeflon tube was attached to a tethered balloon as a sampling inlet for a fast response Proton Transfer Reaction Mass Spectrometer (PTRMS). Along with meteorological instruments deployed on the tethered balloon and at 3-mand outputs from a regional weather model, these observations were used to estimate landscape scale biogenic volatile organic compound fluxes with two micrometeorological techniques: mixed layer variance and surface layer gradients. This highly mobile sampling system was deployed at four field sites near Barcelona to estimate landscape-scale BVOC emission factors in a relatively short period (3 weeks). The two micrometeorological techniques agreed within the uncertainty of the flux measurements at all four sites even though the locations had considerable heterogeneity in species distribution and complex terrain. The observed fluxes were significantly different than emissions predicted with an emission model using site-specific emission factors and land-cover characteristics. Considering the wide range in reported BVOC emission factors of VOCs for individual vegetation species (more than an order of magnitude), this flux estimation technique is useful for constraining BVOC emission factors used as model inputs.

Greenberg, Jim↗