Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BYPASSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Designing Modules to Prevent Reverse Bias Degradation in Perovskite Solar Cells when Partial Shading Occurs

When a solar cell in a panel is shaded, the illuminated cells can place a large reverse bias on the shaded cell to attempt to force current through it. Although the panel can continue to produce power, the reverse bias can cause significant problems for the shaded cell. In the case of perovskite solar modules, Joule heating and irreversible electrochemical reactions will degrade the cell. Some photovoltaic technologies use bypass diodes to solve this problem. To prevent both a perovskite cell and an all-perovskite tandem cell from falling into reverse bias breakdown while shaded, no more than two cells per bypass diode are allowed, which is likely to be prohibitively expensive for many applications. Herein, how many solar cells can be protected by one bypass diode in single-junction and multijunction perovskite modules is explored. It is easier to incorporate bypass diodes into modules with singulated cells than with monolithic panels. It is shown that perovskite–silicon tandems can be protected with fewer bypass diodes than with single-junction perovskite modules. Furthermore, it is suggested that if bypass diodes cannot be feasibly incorporated, then the panels should be deployed in utility-scale power plants.

14 SOLAR ENERGY↗

Experimental Investigation of Forced Convection and Natural Circulation Cooling of a VHTR Core under Normal Operation and Accident Scenarios

This NEUP project #15-8205 entitled “Experimental Investigation of Forced Convection and Natural Circulation Cooling of a VHTR Core under Normal Operation and Accident Scenarios”, has investigated important phenomena in the safety of Very High Temperature Reactors (VHTRs) using the experimental facilities at City College of New York (CCNY) and Kansas State University (KSU), in collaboration with the Idaho State University (ISU) and Idaho National Laboratory (INL). The main objectives of this project were to investigate the forced convection and bypass flow phenomena, natural circulation flow and heat transfer, and graphite oxidation due to air ingress which could occur in a Very High Temperature Reactor (VHTR) with a prismatic core. High pressure/high temperature experiments have been conducted to obtain data that could be used for validation of VHTR design and safety analysis codes. The focus of these experiments was on the generation of benchmark data for design and off-design heat transfer for forced and natural circulation in a VHTR core. This work has built on the previous NEUP project #11-3218 which investigated forced convection and flow laminarization phenomena in a prismatic core of a VHTR and natural circulation of a pure gas under Pressurized Conduction Cooldown (PCC) and Depressurized Conduction Cooldown (DCC) conditions. Under each Task, extensive literature reviews on natural circulation, bypass flow, air ingress and graphite oxidation phenomena were conducted. In Task 1, scaling analyses were conducted by Idaho State University followed by design and construction of experimental facilities needed to conduct both bypass flow and natural circulation experiments at CCNY. Natural circulation experiments were conducted in Task 2 to investigate the air ingress phenomena, and bypass flow phenomena in Task 3, both at CCNY. In Task 4, radiation heat transfer and graphite oxidation tests were performed at Kansas State University. The experimental data were then analyzed to obtain quantitative results on natural circulation of pure gases and gas mixtures under DCC conditions, bypass flow rates, radiation heat transfer and graphite oxidation. In addition, CFD and Direct Numerical Simulations were conducted by INL and CCNY to investigate the flow laminarization phenomenon in strongly heated gas flows. The scaling analyses have shown that the key nondimensional numbers and parameters all have acceptable distortion levels principally because the CCNY facility’s test sections have representative cooling channel dimensions and are using either helium or a scalable gas such as nitrogen at representative state conditions. The natural circulation experiments involving helium and nitrogen gas mixtures at CCNY have elucidated the effect of nitrogen (simulating air) ingress into a lower plenum on the onset of natural circulation, mass flow rates and heat transfer coefficients under different power input levels in the riser section. Also, the transport of nitrogen from the lower plenum to upper plenum due to natural circulation was quantified for the first time. Nusselt number correlations for the heat transfer coefficient under natural circulation as a function of Reynolds and Prandtl numbers was also developed. The experiments at KSU revealed that prior to the onset of natural circulationin a VHTR core. This work has built on the previous NEUP project #11-3218 which investigated forced convection and flow laminarization phenomena in a prismatic core of a VHTR and natural circulation of a pure gas under Pressurized Conduction Cooldown (PCC) and Depressurized Conduction Cooldown (DCC) conditions. Under each Task, extensive literature reviews on natural circulation, bypass flow, air ingress and graphite oxidation phenomena were conducted. In Task 1, scaling analyses were conducted by Idaho State University followed by design and construction of experimental facilities needed to conduct both bypass flow and natural circulation experiments at CCNY. Natural circulation experiments were conducted in Task 2 to investigate the air ingress phenomena, and bypass flow phenomena in Task 3, both at CCNY. In Task 4, radiation heat transfer and graphite oxidation tests were performed at Kansas State University. The experimental data were then analyzed to obtain quantitative results on natural circulation of pure gases and gas mixtures under DCC conditions, bypass flow rates, radiation heat transfer and graphite oxidation. In addition, CFD and Direct Numerical Simulations were conducted by INL and CCNY to investigate the flow laminarization phenomenon in strongly heated gas flows. The scaling analyses have shown that the key nondimensional numbers and parameters all have acceptable distortion levels principally because the CCNY facility’s test sections have representative cooling channel dimensions and are using either helium or a scalable gas such as nitrogen at representative state conditions.The natural circulation experiments involving helium and nitrogen gas mixtures at CCNY have elucidated the effect of nitrogen (simulating air) ingress into a lower plenum on the onset of natural circulation, mass flow rates and heat transfer coefficients under different power input levels in the riser section. Also, the transport of nitrogen from the lower plenum to upper plenum due to natural circulation was quantified for the first time. Nusselt number correlations for the heat transfer coefficient under natural circulation as a function of Reynolds and Prandtl numbers was also developed. The experiments at KSU revealed that prior to the onset of natural circulation(ONC), molecular diffusion plays a significant role in air-ingress, however, at higher temperatures convection currents may be influencing air ingress and in-turn ONC times. Bypass flow experiments faced difficulties in the measurement of gas velocity in the main channel due to the failure of a high temperature Hot Wire Anemometer probe, so an energy balance method was instead employed to estimate the flow distribution between the main and bypass flow channels. In the graphite oxidation experiments conducted at KSU, oxidation was found to increase the thermal diffusivity of nuclear grade graphite. This change is believed to be driven by oxidation decreasing graphite sample density rather than raising the thermal conductivity. Oxidation was also shown to greatly alter graphite emissivity. If large amounts of impurities have built up within the graphite over time and have significantly increased its effective ash content, then air ingress is likely to severely inhibit the radiative heat transfer abilities of the graphite due to the formation of low emissivity, ash layers on its surface. However, if the purity of the graphite at the time of the air ingress is still close to that of its virgin specifications, the oxidation induced roughening of the graphite’s outer surface would have the effect of slightly raising its emissivity. The flow laminarization phenomenon was investigated by INL by examining the results of Direct Numerical Simulations of previous experiments, and by CCNY conducting its own DNS simulations using DOE’s Nek5000 code

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coupled supercritical CO2 dissolution and water flow in pore-scale micromodels

Dissolution trapping is one of the most important mechanisms for geological carbon storage (GCS). Recent laboratory and field experiments have shown non-equilibrium dissolution of supercritical CO2 (scCO2) and coupled scCO2 dissolution and water flow, i.e., scCO2 dissolution at local pores/pore throats creating new water-flow paths, which in turn enhance dissolution by increased advection and interfacial area. However, the impacts of pore-scale characteristics on these coupled processes have not been investigated. In this study, imbibition and dissolution experiments were conducted under 40°C and 9?MPa using a homogeneous/isotropic hexagonal micromodel, two homogeneous elliptical micromodels with low or high anisotropy, and a heterogeneous sandstone-analog micromodel. The four micromodels, initially saturated with deionized (DI)-water, were drained by injecting scCO2 to establish a stable scCO2 saturation. DI water was then injected at different rates with logCa (the capillary number) ranging from -6.56 to -4.34. Results show that bypass of scCO2 by displacing water is the dominant mechanism contributing to the residual CO2 trapping, triggered by heterogeneity in pore characteristics or pore-scale scCO2-water distribution. Bypass can be enhanced by pore heterogeneity or reduced by increasing transverse permeability, resulting in relatively low (<2% of CO2 solubility) or high (9–13% of CO2 solubility) dissolved CO2 concentration in displacing water. The overall dissolution of residual scCO2 increases with decreasing Ca, and approaches to their solubility at low Ca value with sufficient residence time. This main trend is similar to a capillary desaturation curve that represents the relationship between the residual saturation and Ca. Spatially, dissolution initiates along the boundary of bypassed scCO2 cluster(s) in a non-equilibrium manner, and the coupling of water flow and dissolution occurs which fragments the bypassed scCO2 clusters and enhance scCO2 dissolution.

Chang, Chun↗

Financial Analysis of the Smallmouth Bass Flows implemented at the Glen Canyon Dam during Water Year 2024

The Glen Canyon Dam (GCD) is a Colorado River Storage Project (CRSP) power resource that is a component of the Salt Lake City Area Integrated Projects (SLCA/IP). The 2016 record of decision (ROD) for the GCD long-term experimental and management plan (LTEMP) final Environmental Impact Statement (EIS) specifies criteria for GCD monthly water releases, daily and hourly operating limits, and experimental releases. This report presents a financial analysis of the Smallmouth bass (Micropterus dolomieu) (SMB) flows implemented at GCD during Water Year (WY) 2024. These bypass flows were introduced by the U.S. Bureau of Reclamation (USBR) as an emergency response to the growing threat posed by invasive SMB in the Colorado River ecosystem downstream of the dam. SMB are a non-native predatory species that pose a significant threat to native fish populations, including the endangered humpback chub (Gila cypha). The thermal regime below GCD, typically cold due to hypolimnetic releases from Lake Powell, has historically served as a thermal barrier limiting SMB establishment. However, persistently low reservoir levels in recent years have reduced stratification in Lake Powell, allowing warmer water to be released downstream. This has enabled SMB to spawn successfully below the dam, prompting urgent ecological concerns. To mitigate the risk of SMB proliferation, the USBR implemented a series of bypass flows in WY 2024. Drawn from a lower elevation than the penstocks, the bypass structures released cooler water downstream. These short-duration bypass flows aimed to keep temperatures cool enough to prevent SMB from spawning, thereby reducing the ecological threat posed by this invasive species. Although motivated by ecological objectives, these bypass flows came with financial tradeoffs. Releasing water through the bypass structures instead of the turbines at GCD reduced hydropower generation, resulting in a significantly lower financial position for Western Area Power Administration (WAPA), which is responsible for marketing the electricity produced by the GCD Powerplant. This report analyzes the financial impact of the SMB flows implemented from July to November 2024. These experimental releases led to an estimated financial cost of approximately $18.9 million, primarily driven by the substantial volume of water diverted through the bypass structures. This study applies an integrated set of tools to estimate WAPA financial impacts by simulating GCD under two types of cases; namely, (1) a “With Experiment” case that mimics the water operations that actually occurred, including the SMB bypass flows, and (2) a “Without Experiment” case that simulates operations under the assumption that the SMB flows did not occur. Both cases comply with LTEMP hourly and daily operating criteria, and the monthly water release volumes are assumed to be identical under both cases. The Colorado River Storage Project Python-based model (CRiSPPy) model was the main modeling tool used to simulate the dispatch of the GCD hydropower plant and associated water releases from Lake Powell. In the modeling process, the research team used extensive data sets and historical information on SLCA/IP power plant characteristics, hydrologic conditions, and WAPA’s power purchases and sales prices.

13 HYDRO ENERGY↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variable mixer propulsion cycle

A design technique, method and apparatus are delineated for controlling the bypass gas stream pressure and varying the bypass ratio of a mixed flow gas turbine engine in order to achieve improved performance. The disclosed embodiments each include a mixing device for combining the core and bypass gas streams. The variable area mixing device permits the static pressures of the core and bypass streams to be balanced prior to mixing at widely varying bypass stream pressure levels. The mixed flow gas turbine engine therefore operates efficiently over a wide range of bypass ratios and the dynamic pressure of the bypass stream is maintained at a level which will keep the engine inlet airflow matched to an optimum design level throughout a wide range of engine thrust settings.

Rundell, D. J.↗

Analysis of Turbofan Design Options for an Advanced Single-Aisle Transport Aircraft

The desire for higher engine efficiency has resulted in the evolution of aircraft gas turbine engines from turbojets, to low bypass ratio, first generation turbofans, to today's high bypass ratio turbofans. It is possible that future designs will continue this trend, leading to very-high or ultra-high bypass ratio (UHB) engines. Although increased bypass ratio has clear benefits in terms of propulsion system metrics such as specific fuel consumption, these benefits may not translate into aircraft system level benefits due to integration penalties. In this study, the design trade space for advanced turbofan engines applied to a single-aisle transport (737/A320 class aircraft) is explored. The benefits of increased bypass ratio and associated enabling technologies such as geared fan drive are found to depend on the primary metrics of interest. For example, bypass ratios at which fuel consumption is minimized may not require geared fan technology. However, geared fan drive does enable higher bypass ratio designs which result in lower noise. Regardless of the engine architecture chosen, the results of this study indicate the potential for the advanced aircraft to realize substantial improvements in fuel efficiency, emissions, and noise compared to the current vehicles in this size class.

Guynn, Mark D.↗

Process design of the piperazine advanced stripper for a 460 MW NGCC

The Texas Carbon Management Program is conducting a Front-End Engineering Design (FEED) for Piperazine with the Advanced Stripper™ (PZAS™) at a natural gas combined cycle power plant in west Texas. Here, this paper presents the design of the advanced stripper system with an emphasis on the selection of packing type, packing height, column diameter, and heat exchanger size, demonstrates the effect of ambient temperature swing on the regeneration energy requirement, and investigates two alternate process configurations that provide better energy performance than PZAS™. The design uses 2 stripper trains, and each train uses two cold cross exchangers, one hot cross exchanger, a stripper column, a CO 2 exchanger, and a condenser. Each column consists of two sections of random packing with RSR 2 packing at the top and RSR 3 packing at the bottom, with a total packed height of 7.5 m. The cold exchanger was designed with an NTU of 6, the hot exchanger with an NTU of 2, and the CO 2 exchanger with an NTU of 5. At 0.4 rich loading and 0.2 lean loading, this design resulted in a heat duty of 2.85 GJ/tonne CO 2 . The heat duty can vary up to 3.1 GJ/tonne CO 2 due to lower rich loading at higher summer temperature, but the absolute steam requirement is 8–15% lower in the summer. An alternate design, PZAS with hot rich bypass, is proposed, which can reduce the equivalent work of stripping by 1.5–3.5% compared to PZAS at low heat exchanger size, due to a reduction in stripper driving force. Using a hot rich bypass increases the vapor fraction of the total rich bypass stream from 0.3 to 1 mol% compared to using the warm rich bypass, which also contributes to a reduction in lost work in the column. PZAS with hot rich bypass outperforms PZAS in energy requirement below a packing height of 15 m, but fails to do so above 15 m of packing due to a column pinch that results in little change in LMTD of the column. PZAS with hot rich bypass has the potential to minimize capital cost in addition to reducing energy requirement as it requires less packing to strip CO 2 than PZAS and requires only one cross exchanger with 8 heat transfer units.

03 NATURAL GAS↗

Structural and Functional Elucidation of the Mechanism Promoting Error-prone Synthesis by Human DNA Polymerase [kappa] Opposite the 7,8-Dihydro-8-oxo-2'-deoxyguanosine Adduct

Human polymerase kappa (hPol {kappa}) is one of four eukaryotic Y-class DNA polymerases and may be an important element in the cellular response to polycyclic aromatic hydrocarbons such as benzo[a]pyrene, which can lead to reactive oxygenated metabolite-mediated oxidative stress. Here, we present a detailed analysis of the activity and specificity of hPol {kappa} bypass opposite the major oxidative adduct 7,8-dihydro-8-oxo-2{prime}-deoxyguanosine (8-oxoG). Unlike its archaeal homolog Dpo4, hPol {kappa} bypasses this lesion in an error-prone fashion by inserting mainly dATP. Analysis of transient-state kinetics shows diminished 'bursts' for dATP:8-oxoG and dCTP:8-oxoG incorporation, indicative of non-productive complex formation, but dATP:8-oxoG insertion events that do occur are 2-fold more efficient than dCTP:G insertion events. Crystal structures of ternary hPol {kappa} complexes with adducted template-primer DNA reveal non-productive (dGTP and dATP) alignments of incoming nucleotide and 8-oxoG. Structural limitations placed upon the hPol {kappa} by interactions between the N-clasp and finger domains combined with stabilization of the syn-oriented template 8-oxoG through the side chain of Met-135 both appear to contribute to error-prone bypass. Mutating Leu-508 in the little finger domain of hPol {kappa} to lysine modulates the insertion opposite 8-oxoG toward more accurate bypass, similar to previous findings with Dpo4. Our structural and activity data provide insight into important mechanistic aspects of error-prone bypass of 8-oxoG by hPol {kappa} compared with accurate and efficient bypass of the lesion by Dpo4 and polymerase {eta}.

36 MATERIALS SCIENCE↗

Active Magnetic Regenerative Liquefier

This final report for the DOE Project entitled Active Magnetic Regenerative Liquefier (AMRL) funded under Grant DE-FG36-08GO18064 to Heracles Energy Corporation d.b.a. Prometheus Energy (Heracles/Prometheus) describes an active magnetic regenerative refrigerator (AMRR) prototype designed and built during the period from July 2008 through May 2011. The primary goal of this project was to make significant technical advances toward highly efficient liquefaction of hydrogen. Conventional hydrogen liquefiers at any scale have a maximum FOM of ~0.35 due primarily to the intrinsic difficulty of rapid, efficient compression of either hydrogen or helium working gases. Numerical simulation modeling of high performance AMRL designs indicates certain designs have promise to increase thermodynamic efficiency from a FOM of ~0.35 toward ~0.5 to ~0.6. The technical approach was the use of solid magnetic working refrigerants cycled in and out of high magnetic fields to build an efficient active regenerative magnetic refrigeration module providing cooling power for AMRL. A single-stage reciprocating AMRR with a design temperature span from ~290 K to ~120 K was built and tested with dual magnetic regenerators moving in and out of the conductively-cooled superconducting magnet subsystem. The heat transfer fluid (helium) was coupled to the process stream (refrigeration/liquefaction load) via high performance heat exchangers. In order to maximize AMRR efficiency a helium bypass loop with adjustable flow was incorporated in the design because the thermal mass of magnetic refrigerants is higher in low magnetic field than in high magnetic field. Heracles/Prometheus designed experiments to measure AMRR performance under a variety of different operational parameters such as cycle frequency, magnetic field strength, heat transfer fluid flow rate, amount of bypass flow of the heat transfer fluid while measuring work input, temperature span, cooling capability as a function of cold temperature as a function of the amount of bypass flow of the heat transfer fluid. The operational AMRR prototype can be used to answer key questions such as the best recipe for multiple layers of different magnetic refrigerants in one or more integrated regenerators with varying amounts of bypass flow of the heat transfer fluid. Layered regenerators are necessary to span the AMRR range from 290 K to 120K. Our AMRR performance simulation model predicts that ~10-15 % of bypass flow should significantly improve the thermodynamic performance. Initial results obtained with regenerators made of gadolinium spheres were very encouraging; a temperature span of ~ 50 K (between 295K and 245 K) across both regenerators was achieved with zero bypass flow of the heat transfer fluid and with the magnetic field strength of ~4 T.

42 ENGINEERING↗

A supersonic through-flow fan engine airframe integration study

A study is undertaken to investigate the engine airframe integration effects for supersonic through-flow fan engines installed on a Mach 3.20 supersonic cruise vehicle. Six different supersonic through-flow fan engine installations covering the effects of engine size, nacelle contour, nacelle placement, and approximate bypass plume effects are presented. The different supersonic through-flow fan installations are compared with a conventional turbine bypass engine configuration on the same basic airframe. The supersonic through-flow fan engine integrations are shown to be comparable to the turbine bypass engine configuration on the basis of installed nacelle wave drag. The supersonic through-flow fan engine airframe integrated vehicles have superior aerodynamic performance on the basis of maximum lift-to-drag ratio than the turbine bypass engine installation over the entire operating Mach number range from 1.10 to 3.20. When approximate bypass plume modeling is included, the supersonic through-flow fan engine configuration shows even larger improvements over the turbine bypass engine configuration.

Barnhart, Paul J.↗

A supersonic through-flow fan engine airframe integration study

Engine airframe integration effects are investigated for supersonic through-flow fan engines installed on a Mach 3.20 supersonic cruise vehicle. Six different supersonic through-flow fan engine installations covering the effects of engine size, nacelle contour, nacelle placement, and approximate bypass plume effects are presented. The different supersonic through-flow fan installations are compared with a conventional turbine bypass engine configuration on the same basic airframe. The supersonic through-flow fan engine integrations are shown to be comparable to the turbine bypass engine configuration on the basis of installed nacelle wave drag. The supersonic through-flow fan engine airframe integrated vehicles have superior aerodynamic performance on the basis of maximum lift-to-drag ratio than the turbine bypass engine installation over the entire operating Mach number range from 1.10 to 3.20. When approximate bypass plume modeling is included, the supersonic through-flow fan engine configuration shows even larger improvements over the turbine bypass engine configuration.

Barnhart, Paul J.↗

Thrust reverser with variable nozzle

A thrust reverser is provided for both modulating and reversing bypass flow discharged from a fan through a bypass duct of a turbofan gas turbine engine. The reverser includes an aft cowl joined to a forward cowl and having an aft end surrounding a core engine to define a discharge fan nozzle of minimum flow throat area. The aft cowl is axially translatable relative to the forward cowl from a first position fully retracted against the forward cowl, to a second position partially extended from the forward cowl, and to a third position fully extended from the forward cowl. A plurality of cascade turning vanes are disposed between the forward and aft cowls, and a plurality of thrust reversing deflector doors are pivotally mounted to the aft cowl and bound the bypass duct. The deflector doors are selectively deployed from a stowed position corresponding with the first and second positions of the aft cowl for allowing unrestricted flow of the bypass flow through the fan nozzle. The doors also have a deployed position corresponding with the third position of the aft cowl for substantially deflecting the bypass flow from discharging through the fan nozzle to discharging through the cascade vanes for effecting thrust reverse. Axial translation of the aft cowl between the first and second positions varies flow area of the fan nozzle to vary thrust effected by the discharged bypass flow.

Butler, Lawrence↗

Engine Concept Study for an Advanced Single-Aisle Transport

The desire for higher engine efficiency has resulted in the evolution of aircraft gas turbine engines from turbojets, to low bypass ratio, first generation turbofans, to today's high bypass ratio turbofans. Although increased bypass ratio has clear benefits in terms of propulsion system metrics such as specific fuel consumption, these benefits may not translate into aircraft system level benefits due to integration penalties. In this study, the design trade space for advanced turbofan engines applied to a single aisle transport (737/A320 class aircraft) is explored. The benefits of increased bypass ratio and associated enabling technologies such as geared fan drive are found to depend on the primary metrics of interest. For example, bypass ratios at which mission fuel consumption is minimized may not require geared fan technology. However, geared fan drive does enable higher bypass ratio designs which result in lower noise. The results of this study indicate the potential for the advanced aircraft to realize substantial improvements in fuel efficiency, emissions, and noise compared to the current vehicles in this size class.

Guynn, Mark D.↗

Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger

An active thermal control system architecture has been modified to include a regenerative heat exchanger (regenerator) inboard of the radiator. Rather than using a radiator bypass valve a regenerative heat exchanger is placed inboard of the radiators. A regenerator cold side bypass valve is used to set the return temperature. During operation, the regenerator bypass flow is varied, mixing cold radiator return fluid and warm regenerator outlet fluid to maintain the system setpoint. At the lowest heat load for stable operation, the bypass flow is closed off, sending all of the flow through the regenerator. This lowers the radiator inlet temperature well below the system set-point while maintaining full flow through the radiators. By using a regenerator bypass flow control to maintain system setpoint, the required minimum heat load to avoid radiator freezing can be reduced by more than half compared to a radiator bypass system.

Ungar, Eugene K.↗