Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

An Aneurysmal Left Circumflex Artery-to-Right Atrium Fistula in a Patient with Ischemic Symptoms: Accurate Diagnosis with Dual-Source CT Angiography

In this report, we present a 55-year-old female patient with a left circumflex artery-to-right atrial fistula associated with a huge saccular aneurysm. She had undergone conventional angiography due to ischemic symptoms. In conventional angiography, a very dilated and tortuous vessel originating from the circumflex artery and continuous with a huge saccular aneurysm was visualized but the drainage site could not be demonstrated. With dual-source CT coronary angiography, the exact anatomy of this fistula was demonstrated and surgery was planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemoembolization Via Branches from the Splenic Artery in Patients with Hepatocellular Carcinoma

Purpose: This study was designed to evaluate the radiologic findings and imaging response of chemoembolization via branches of the splenic artery in patients with hepatocellular carcinoma (HCC). Methods: From January 2001 to July 2010, we observed tumor staining supplied by branches of the splenic artery in 34 (0.6%) of 5,413 patients with HCC. Computed tomography (CT) scans and digital subtraction angiograms of these patients were retrospectively reviewed in consensus by two investigators. Results: A total of 39 tumor feeding-vessels in 34 patients were identified: omental branches from the left gastroepiploic artery (n = 5), branches from the short gastric artery (n = 9), and omental branches directly from the splenic artery (n = 25). Branches of the splenic artery that supplied tumors were revealed on the celiac angiogram in 29 (85%) of 34 patients and were detected on pre-procedure CT images in 27 (79%) of 34 patients. Selective chemoembolization was achieved in 38 of 39 tumor-feeding vessels. Complete or partial response of the tumor fed by branches of the splenic artery, as depicted on follow-up CT scans, was achieved in 21 (62%) patients. No patient developed severe complications directly related to chemoembolization via branches of the splenic artery. Conclusions: Omental branches directly from the splenic artery are common tumor-feeding vessels of the splenic artery in cases of advanced HCC with multiple previous chemoembolizations. Tumor-feeding vessels of the splenic artery are usually visualized on the celiac angiogram or CT scan, and chemoembolization through them can be safely performed in most patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A model to simulate the oxygen distribution in hypoxic tumors for different vascular architectures

Purpose: As hypoxic cells are more resistant to photon radiation, it is desirable to obtain information about the oxygen distribution in tumors prior to the radiation treatment. Noninvasive techniques are currently not able to provide reliable oxygenation maps with sufficient spatial resolution; therefore mathematical models may help to simulate microvascular architectures and the resulting oxygen distributions in the surrounding tissue. Here, the authors present a new computer model, which uses the vascular fraction of tumor voxels, in principle measurable noninvasively in vivo, as input parameter for simulating realistic PO2 histograms in tumors, assuming certain 3D vascular architectures.Methods: Oxygen distributions were calculated by solving a reaction-diffusion equation in a reference volume using the particle strength exchange method. Different types of vessel architectures as well as different degrees of vascular heterogeneities are considered. Two types of acute hypoxia (ischemic and hypoxemic) occurring additionally to diffusion-limited (chronic) hypoxia were implemented as well.Results: No statistically significant differences were observed when comparing 2D- and 3D-vessel architectures (p > 0.79 in all cases) and highly heterogeneously distributed linear vessels show good agreement, when comparing with published experimental intervessel distance distributions and PO2 histograms. It could be shown that, if information about additional acute hypoxia is available, its contribution to the hypoxic fraction (HF) can be simulated as well. Increases of 128% and 168% in the HF were obtained when representative cases of ischemic and hypoxemic acute hypoxia, respectively, were considered in the simulations.Conclusions: The presented model is able to simulate realistic microscopic oxygen distributions in tumors assuming reasonable vessel architectures and using the vascular fraction as macroscopic input parameter. The model may be used to generate PO2 histograms, which are needed as input in models predicting the radiation response of hypoxic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model

Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% {+-} 8.43% at 12 weeks in BNS versus 39.77% {+-} 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 {+-} 1.17 versus 2.17 {+-} 0.85 in BNS. The results for vessel wall injury (0.6 {+-} 0.58 for Polyzene-F-coated stents; 0.72 {+-} 0.98 for BNS) and re-endothelialization, (1.16 {+-} 0.43 and 1.23 {+-} 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies ({>=}120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The AMPLATZER Vascular Plug 4: Preliminary Experience

The purpose of this communication is to describe our preliminary experience with the AMPLATZER Vascular Plug 4 (AVP 4) in peripheral vascular embolization. The AVP 4 was used for peripheral vascular embolization in five patients with renal pseudoaneurysm (n = 2), postsurgical peritoneal bleeding (n = 1), posttraumatic gluteal hemorrhage (n = 1), and intercostal pseudoaneurysm (n = 1). Occlusion time was recorded. Patients were followed up clinically and by imaging for 1 month after the procedure. All treated vessels or vascular abnormalities were successfully occluded within 3 min for low-flow circulation and over 8 min for high-flow circulation. At 1-month follow-up, all patients were symptom-free. All deployed devices remained in the original locations and desirable configurations. In conclusion, the AVP 4 seems to be safe and effective for occluding peripheral vessels and vascular abnormalities. Because of its compatibility with 0.038-in. catheters, it can be deployed through a diagnostic catheter following angiography without exchanging a sheath or guiding catheter. Compared with the previous generation of vascular plugs, the AVP 4 allows for faster procedure times and decreased exposure to radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Review of the Current Status of Percutaneous Endovascular Arteriovenous Fistula Creation for Haemodialysis Access

Surgical fistulas were first described over 50 years ago and have revolutionized the outlook for millions of dialysis-dependent patients. Despite many developments, results remain sub-optimal with high rates of primary failure and re-intervention to maintain patency. Surgical fistulas are known to fail in part due to intimal hyperplasia leading to stenosis, and vessel manipulation during anastomosis creation can be contributory. New technology is emerging that allows the endovascular creation of fistulas with minimal vessel trauma and the initial results demonstrate encouraging outcomes with high technical success rates, low re-intervention, and failure rates and good usability for hemodialysis. Two such device systems are currently available, and here, we provide an overview of the current global status of endoAVF, patient selection criteria, trial results, technical aspects, re-interventions, and outlook for the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcome of Carotid Artery Stenting for Radiation-Induced Stenosis

Purpose: Patients who have been irradiated at the neck have an increased risk of symptomatic stenosis of the carotid artery during follow-up. Carotid angioplasty and stenting (CAS) can be a preferable alternative treatment to carotid endarterectomy, which is associated with increased operative risks in these patients. Methods and Materials: We performed a prospective cohort study of 24 previously irradiated patients who underwent CAS for symptomatic carotid stenosis. We assessed periprocedural and nonprocedural events including transient ischemic attack (TIA), nondisabling stroke, disabling stoke, and death. Patency rates were evaluated on duplex ultrasound scans. Restenosis was defined as a stenosis of >50% at the stent location. Results: Periprocedural TIA rate was 8%, and periprocedural stroke (nondisabling) occurred in 4% of patients. After a mean follow-up of 3.3 years (range, 0.3-11.0 years), only one ipsilateral incident event (TIA) had occurred (4%). In 12% of patients, a contralateral incident event was present: one TIA (4%) and two strokes (12%, two disabling strokes). Restenosis was apparent in 17%, 33%, and 42% at 3, 12, and 24 months, respectively, although none of the patients with restenosed vessels became symptomatic. The length of the irradiation to CAS interval proved the only significant risk factor for restenosis. Conclusions: The results of CAS for radiation-induced carotid stenosis are favorable in terms of recurrence of cerebrovascular events at the CAS site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Experience with the Amplatzer Vascular Plug II for Occlusive Purposes in Arteriovenous Hemodialysis Access

The Amplatzer Vascular Plug Type II (AVP II) has proven effective in the therapeutic embolization of various vascular lesions. It benefits from very rapid occlusion of the target lesion and can be deployed, retrieved, and redeployed if required. There is no literature available on use of the AVP II in the maintenance, closure, and management of complicated arteriovenous access in hemodialysis patients. In this series, we present our clinical experience with the use of the AVP II for embolization of problematic hemodialysis access. The AVP II is a self-expandable Nitinol wire-mesh device. Mounted on a delivery wire it has the capability to be deployed, recaptured, and redeployed. In total seven patients (four males: one diabetic, all nonsmokers), with ages ranging from 44 to 81 years (mean, 63 years), were treated between July 2008 and January 2009. One patient had not started dialysis. The remaining six patients had varied histories, with the time on hemodialysis ranging from 1 to 21 years. Retrospective review of clinical notes revealed patient demographics, type of access, device size, deployment site, and outcomes. Indications for embolization included steal syndrome (one patient), high-flow tributaries (two patients), and limb swelling (four patients). All patients had clinical and sonographical follow-up to 3 months. Surgical ligation had either failed, was considered a contraindication due to concerns regarding wound healing, or was considered difficult due to complex venous anatomy. Only one device was used in each patient, ranging from 6 to 16 mm in diameter. Immediate technical success was seen in 100%. All these patients were followed up clinically in the vascular access radiology clinic at 4 weeks and 3 months. Occlusion of the treated vessel and resolution of symptoms were reconfirmed in 100% of cases at 3 months. It was also noted whether patients were having successful dialysis, if required. There were no complications. Average procedural time was 19 min. We conclude that the AVP II is an efficient, safe, and technically simple occlusion device for use in arteriovenous access.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Successful Removal of Malpositioned Chest Drain Within the Liver by Embolization of the Transhepatic Track

The insertion of a chest drain catheter for the management of a pneumothorax in an 82-year-old woman resulted in the unusual complication of liver penetration. The position of the drain was assessed by contrast-enhanced computed tomographic scan. Because the patient was hemodynamically stable and no damage to major vessels was seen on computed tomographic scan, the patient was treated in a nonoperative manner. A procedure was performed under controlled conditions using techniques used during transhepatic liver biopsies but with the addition of a balloon catheter. Embolization of the liver track was performed during chest drain removal. The drain was successfully removed without the complication of bleeding in a patient unsuitable for a general anesthetic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lifesaving Embolization of Coronary Artery Perforation

Coronary artery perforation remains one of the most fearsome complications during cardiac catheterization procedures. Although emergent bypass surgery is the preferred treatment for cases with uncontrollable perforation, endovascular vessel sealing and arrest of bleeding with a combination of balloons, covered stents, or embolic materials have also been proposed. The authors describe a case of emergent lifesaving microcoil embolization of the distal right coronary artery in a patient with uncontrollable grade III guidewire perforation resulting in cardiac tamponade. The relevant literature is reviewed and the merits and limitations of the endovascular approach are highlighted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Segmentation Algorithm for X-ray 3D Angiography and Vessel Catheterization

Vessel Catheterization is a clinical procedure usually performed by a specialist by means of X-ray fluoroscopic guide with contrast-media. In the present paper, we present a simple and efficient algorithm for vessel segmentation which allows vessel separation and extraction from the background (noise and signal coming from other organs). This would reduce the number of projections (X-ray scans) to reconstruct a complete and accurate 3D vascular model and the radiological risk, in particular for the patient. In what follows, the algorithm is described and some preliminary experimental results are reported illustrating the behaviour of the proposed method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of Intra-arterial Cone-Beam Versus Conventional Computed Tomography During Hepatic Arteriography for Transarterial Chemoembolization Planning

Purpose: To compare the imaging characteristics of intra-arterial cone-beam computed tomography during hepatic arteriography (CBCTHA) versus intra-arterial computed tomography during hepatic arteriography (CTHA) for intraprocedural transarterial chemoembolization (TACE) planning. Materials and Methods: This single-institution retrospective study included 144 patients (96 men, mean age 67.9 years; 48 women, mean age 62.3 years) who underwent 181 TACE sessions between January 2015 and July 2017. Intraprocedural CBCTHA (111 procedures) or CTHA (70 procedures) was performed for TACE planning. Reformatted maximum intensity projection CBCTHA and CTHA images were reviewed by two radiologists and classified using an ordinal scoring system (for tumor identification, tumor feeder vessel identification, and streaking artifact) and a binary scoring system (for the presence of breathing motion artifact and field of view encompassing the entire liver). Data were analyzed using an F test and a z-score test. Results: There were no significant differences in demographic and tumor characteristics between the CBCTHA and CTHA patient cohorts. CTHA was superior to CBCTHA for tumor identification (P < .0001), tumor feeder vessel identification (P < .05), streaking artifact (P < .0001), and field of view encompassing the entire liver (P < .0001). There was a trend toward a lower frequency of breathing motion artifact with CTHA than with CBCTHA (1.4% vs. 10%; P = .057). Conclusion: CTHA provides improved clinical relevant imaging information compared to CBCTHA for intraprocedural TACE planning. Level of Evidence: Level III, retrospective comparative study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Arterial Embolisation in a Trauma Patient with a Pre-Existing Aortobifemoral Graft

Pelvic fractures secondary to blunt trauma are associated with a significant mortality rate due to uncontrolled bleeding. Interventional radiology (IR) can play an important and central role in the management of such patients, offering definitive minimally invasive therapy and avoiding the need for high-risk surgery. Rapid access to whole-body computed tomography has been shown to improve survival in polytrauma patients and allows rapid diagnosis of vascular injury and assessment of suitability for endovascular therapy. IR can then target and treat the specific area of bleeding. Embolisation of bleeding pelvic arteries has been shown to be highly effective and should be the treatment of choice in this situation. The branches of the internal iliac artery (IIA) are usually involved, and these arteries are accessed by way of IIA catheterisation after abdominal aortography. Occasionally these arteries cannot be accessed by way of this conventional route because of recent IIA ligation carried out surgically in an attempt to stop the bleeding or because (in the rare situation we describe here) these vessels are excluded secondary to previous aortoiliac repair. In this situation, knowledge of pelvic arterial collateral artery pathways is important because these will continue to supply pelvic structures whilst making access to deep pelvic branches challenging. We describe a rare case, which has not been previously reported in the literature, in which successful embolisation of a bleeding pelvic artery was carried out by way of the collateral artery pathways.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Amplatzer Vascular Plug: A Review of the Device and its Clinical Applications

The Amplatzer Vascular Plug (AVP) is an established embolic device that can be an excellent alternative to coils or detachable balloons to embolize medium to large vessels with high flow. The device is easy to use and can be precisely deployed in the target vessel with high resistance to migration and a low recanalization rate. The technical success of this device is high, indications for use are expanding, and no absolute contraindications have been reported. Since its introduction, the AVP has grown from a single device to a group of 4 models (AVP, AVP II, AVP III, and AVP 4). Each model has a unique design and features that fit different vascular anatomies, hemodynamic situations, and clinical scenarios. Therefore, the new models cannot simply be treated as replacements for older ones. Unpredictable occlusion time remains a major shortcoming for the new models of the AVP. Large vessel size, high flow status, and coagulopathy can prolong the occlusion time, which can offset the cost benefit, reduced procedure time, and reduced radiation dose typically seen with use of the AVP alone. Coils or multiple AVPs can be used to expedite the occlusion process, and large Gelfoam particles also can be used as an adjunct to achieve rapid and reliable occlusion with minimal cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗