Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Dip-molded t-shaped cannula

Cannula, fabricated out of polyetherurethane, has been designed for long-term service. Improved cannula is T-shaped to collect blood from both directions, thus replacing two conventional cannulas that are usually required and eliminating need for large surgical wound. It is fabricated by using dip-molding process that can be adapted to other elastomeric objects having complex shapes. Dimensions of cannula were chosen to optimize its blood-flow properties and to reduce danger of excessive clotting, making it suitable for continuous service up to 21 days in vein or artery of patient.

Broyles, H. F.↗

Some effects of acceleration in man and chimpanzees

Early physiologic experiments using dogs and humans in centrifuges are reviewed. Because of the close similarity between the shape and dimensions of the thoraces of chimpanzees and humans, the former were used to obtain roentgenograms and photokymographic recordings of multiple physiologic variables before and during exposure to +5.8 Gy to study the effects of changes in the gravitational-inertial force environment on the cardiovascular and pulmonary systems during long duration space flight. A computer-controlled sciscanning system was used to obtain a two dimensional map of the amount of radiation emanating from the dorsal and ventricle surfaces after insertion of radioactive microspheres in the right ventricle. By using four different batches of microspheres tagged with isotopes of different energies, the spatial distribution of pulmonary blood flow under four conditions was determined.

Wood, E. H.↗

The rhesus (Macaca mulatta) and crab-eating (Macaca fascicularis) monkeys in cardiovascular and aerospace research

Two nonhuman primate species were used to investigate the effects of gravitoinertial forces on pilot incapacitation and performance impairment, to define human physiologic tolerance and safe exposure limits to these environments, and to obtain data which can be used to evolve new methods to improve man's G tolerance to match the structural capability of new generation aircraft. The macaca fascicularis was used to study the effects of environmental stress and atheroscelerosis on cerebral blood flow and function agents on myocardial and cardiovascular function were studied in the macaca mulatta.

Erickson, H. H.↗

Effects of exercise and excitement on mesenteric and renal dynamics in conscious, unrestrained baboons

Radiotelemetry was used to measure arterial pressure and mesenteric and renal blood flows from nine unrestrained, conscious baboons during periods of rest, moderate exercise, and extreme excitement. A description of the experiments hardware is presented, including artificial depressants phenylcyclidine hydrochloride, 0.5-1.0 mg/kg, and pentobarbital sodium, 15 mg/kg, and an ultrasonic telemetry flow meter. Results showed rising heart rate and arterial pressure coupled with a reduction of mesenteric and renal flows as the level of exercise was increased. These findings are compared with mesenteric and renal flows somewhat above control level, but relatively stable heart rate and arterial pressure, postprandially. Attention is given to a quantitative analysis of the experimental results.

Vatner, S. F.↗

Physiological system integrations with emphasis on the respiratory-cardiovascular system

The integration of two types of physiological system simulations is presented. The long term model is a circulatory system model which simulates long term blood flow variations and compartmental fluid shifts. The short term models simulate transient phenomena of the respiratory, thermoregulatory, and pulsatile cardiovascular systems as they respond to stimuli such as LBNP, exercise, and environmental gaseous variations. An overview of the interfacing approach is described. Descriptions of the variable interface for long term to short term and between the three short term models are given.

Gallagher, R. R.↗

User's instructions for the erythropoiesis regulatory model

The purpose of the model provides a method to analyze some of the events that could account for the decrease in red cell mass observed in crewmen returning from space missions. The model is based on the premise that erythrocyte production is governed by the balance between oxygen supply and demand at a renal sensing site. Oxygen supply is taken to be a function of arterial oxygen tension, mean corpuscular hemoglobin concentration, oxy-hemoglobin carrying capacity, hematocrit, and blood flow. Erythrocyte destruction is based on the law of mass action. The instantaneous hematocrit value is derived by integrating changes in production and destruction rates and accounting for the degree of plasma dilution.

Source record↗

Dynamic regulation of erythropoiesis: A computer model of general applicability

A mathematical model for the control of erythropoiesis was developed based on the balance between oxygen supply and demand at a renal oxygen detector which controls erythropoietin release and red cell production. Feedback regulation of tissue oxygen tension is accomplished by adjustments of hemoglobin levels resulting from the output of a renal-bone marrow controller. Special consideration was given to the determinants of tissue oxygenation including evaluation of the influence of blood flow, capillary diffusivity, oxygen uptake and oxygen-hemoglobin affinity. A theoretical analysis of the overall control system is presented. Computer simulations of altitude hypoxia, red cell infusion hyperoxia, and homolytic anemia demonstrate validity of the model for general human application in health and disease.

Leonard, J. I.↗

Evaluation of exercise-respiratory system modifications and integration schemes for physiological systems

Exercise subroutine modifications are implemented in an exercise-respiratory system model yielding improvement of system response to exercise forcings. A more physiologically desirable respiratory ventilation rate in addition to an improved regulation of arterial gas tensions and cerebral blood flow is observed. A respiratory frequency expression is proposed which would be appropriate as an interfacing element of the respiratory-pulsatile cardiovascular system. Presentation of a circulatory-respiratory system integration scheme along with its computer program listing is given. The integrated system responds to exercise stimulation for both nonstressed and stressed physiological states. Other integration possibilities are discussed with respect to the respiratory, pulsatile cardiovascular, thermoregulatory, and the long-term circulatory systems.

Gallagher, R. R.↗

Distribution of pulmonary ventilation and perfusion during short periods of weightlessness

Airborne experiments were conducted on four trained normal male subjects (28-40 yr) to study pulmonary function during short periods (22-27 sec) of zero gravity obtained by flying a jet aircraft through appropriate parabolic trajectories. The cabin was always pressurized to a sea-level altitude. The discussion is limited to pulmonary ventilation and perfusion. The results clearly demonstrate that gravity is the major factor causing nonuniformity in the topographical distribution of pulmonary ventilation. More importantly, the results suggest that virtually all the topographical nonuniformity of ventilation, blood flow, and lung volume observed under 1-G conditions are eliminated during short periods of zero gravity.

Michels, D. B.↗

System parameters for erythropoiesis control model: Comparison of normal values in human and mouse model

The computer model for erythropoietic control was adapted to the mouse system by altering system parameters originally given for the human to those which more realistically represent the mouse. Parameter values were obtained from a variety of literature sources. Using the mouse model, the mouse was studied as a potential experimental model for spaceflight. Simulation studies of dehydration and hypoxia were performed. A comparison of system parameters for the mouse and human models is presented. Aside from the obvious differences expected in fluid volumes, blood flows and metabolic rates, larger differences were observed in the following: erythrocyte life span, erythropoietin half-life, and normal arterial pO2.

Source record↗

Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

Greenleaf, J. E.↗

Cuff for Blood-Vessel Pressure Measurements

Pressure within blood vessel is measured by new cufflike device without penetration of vessel. Device continuously monitors blood pressure for up to 6 months or longer without harming vessel. Is especially useful for vessels smaller than 4 or 5 millimeters in diameter. Invasive methods damage vessel wall, disturb blood flow, and cause clotting. They do not always give reliable pressure measurements over prolonged periods.

Shimizu, M.↗

Rheography in weightlessness

Small-scale rheographic devices for use on a space ship were developed and used during flights for the study of blood flow in vascular regions. The processes that occur during space flight and the adaptation of the human body to weightlessness are understood. The future condition of the cosmonauts' health is predicted.

Kasyan, I.↗

Determination of oxygen tension in the subcutaneous tissue of cosmonauts during the Salyut-6 mission

A polarographic technique was used to measure the oxygen tension in subcutaneous tissue of the forearm of a cosmonaut prior to, after, and on the fourth day of a space mission performed by Salut-6. A drop in the oxygen exchange rate in the peripheral tissues during weightlessness was observed. The mechanisms of this change are studied, taking into consideration the blood distribution in the organism and microcirculation disorders reflected by a decreased blood flow rate in arterial-venous junctions.

Baranski, S.↗

Implantable telemetry for small animals

A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.

Source record↗

Alterations in heat loss and heat production mechanisms in rat exposed to hypergravic fields

A review of studies investigating the thermal response of rats exposed to hypergravic fields well below maximum tolerance levels is presented. It is concluded that several lines of evidence indicate that the neural switching network for temperature regulation and cardiovascular channeling of blood flow is transiently affected during the first hour a rat is exposed to hypergravity. Moreover, even after one hour of exposure, when the core temperature has fallen several degrees, shivering and nonshivering thermogenesis are not fully activated. Only after prolonged exposure to hypergravic fields do heat production mechanisms recover sufficiently to bring the core temperature back to a normal level. Thus, the data indicate a more rapid recovery of effector mechanisms for heat loss than for heat production.

Horowitz, J. M.↗

Development of limb volume measuring system

The mechanisms underlying the reductions in orthostatic tolerance associated with weightlessness are not well established. Contradictory results from measurements of leg volume changes suggest that altered venomotor tone and reduced blood flow may not be the only contributors to orthostatic intolerance. It is felt that a more accurate limb volume system which is insensitive to environmental factors will aid in better quantification of the hemodynamics of the leg. Of the varous limb volume techniques presently available, the ultrasonic limb volume system has proven to be the best choice. The system as described herein is free from environmental effects, safe, simple to operate and causes negligible radio frequency interference problems. The segmental ultrasonic ultrasonic plethysmograph is expected to provide a better measurement of limb volume change since it is based on cross-sectional area measurements.

Bhagat, P. K.↗

A study of stress-free living bone and its application to space flight

Observations of animals and human subjects in weightless space flight (Skylab and COSMOS) document altered bone metabolism. Bone metabolism is affected by a number of local and systemic factors. The calcification and growth of transplanted bone is independent of local muscle, nervous, and mechanical forces; therefore, transplanted bone would provide data on the role of local vs. systematic factors. Bone metabolism in living transplanted bone, devoid of stress, was investigated as a possible tool for the investigation of countermeasures against disuse bone loss. An animal model using Sprague-Dawley rats was developed for transplantation of femur bone tissue on a nutrient vascular pedicel. The long term course of these implants was assessed through the measure of regional and total bone mineral, blood flow, and methylene diphosphonate (MDP) uptake. Clomid, an estrogen agonist/antagonist, was shown to protect bone from disuse loss of minerals by retarding trabecular and cortical resorption.

Leblanc, A.↗