Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automatic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

TU-F-CAMPUS-I-04: A Novel Phantom to Evaluate Longitudinal and Angular Automatic Tube Current Modulation (ATCM) in CT

Purpose: To manufacture a phantom specifically designed for the purpose of evaluating the performance of the longitudinal and angular automatic tube current modulation (ATCM) on modern CT scanners. Methods: In order to evaluate angular ATCM, the phantom has an elliptical cross section (aspect ratio 3:2). To evaluate longitudinal ATCM, the phantom consists of 3 sections, with different major axes (25 cm, 30 cm and 35 cm). Each section is 15 cm long in the longitudinal direction. Between each section is a smooth transition. The phantom was milled from a solid block of PMMA. ATCM performance is evaluated by 1) analyzing the applied tube current for each slice of the phantom and 2) analyzing the distribution of image noise (σ) along the scan direction at different positions in the phantom. A demonstration of the ATCM performance evaluation is given by investigating the effects of miscentering during a CT scan. Results: The developed phantom has proven useful for evaluating both the longitudinal and angular ATCM on modern CT scanners (spiral collimations ≥ 4 cm). Further benefits are the smooth transitions between the sections that prevent abnormal responses in the ATCM and the invariant sections that provide a means for investigating the stability of image noise. The homogeneity of the phantom makes image noise at different positions along the scan direction easy to quantify, which is crucial to understand how well the applied ATCM can produce a desired image quality. Conclusion: It is important to understand how the ATCM functions on CT scanners as it can directly affect dose and image quality. The phantom that has been developed is a most valuable tool to understand how different variables during a scan can affect the outcome of the longitudinal and angular ATCM.

60 APPLIED LIFE SCIENCES↗

SU-F-I-31: Reproducibility of An Automatic Exposure Control Technique in the Low-Dose CT Scan of Cardiac PET/CT Exams

Purpose: Two separate low-dose CT scans are usually performed for attenuation correction of rest and stress N-13 ammonia PET/CT myocardial perfusion imaging (PET/CT). We utilize an automatic exposure control (AEC) technique to reduce CT radiation dose while maintaining perfusion image quality. Our goal is to assess the reproducibility of displayed CT dose index (CTDI) on same-day repeat CT scans (CT1 and CT2). Methods: Retrospectively, we reviewed CT images of PET/CT studies performed on the same day. Low-dose CT utilized AEC technique based on tube current modulation called Smart-mA. The scan parameters were 64 × 0.625mm collimation, 5mm slice thickness, 0.984 pitch, 1-sec rotation time, 120 kVp, and noise index 50 with a range of 10–200 mA. The scan length matched with PET field of view (FOV) with the heart near the middle of axial FOV. We identified the reference slice number (RS) for an anatomical landmark (carina) and used it to estimate axial shift between two CTs. For patient size, we measured an effective diameter on the reference slice. The effect of patient positioning to CTDI was evaluated using the table height. We calculated the absolute percent difference of the CTDI (%diff) for estimation of the reproducibility. Results: The study included 168 adults with an average body-mass index of 31.72 ± 9.10 (kg/m{sup 2}) and effective diameter was 32.72 ± 4.60 cm. The average CTDI was 1.95 ± 1.40 mGy for CT1 and 1.97 ± 1.42mGy for CT2. The mean %diff was 7.8 ± 6.8%. Linear regression analysis showed a significant correlation between the table height and %diff CTDI. (r=0.82, p<0.001) Conclusion: We have shown for the first time in human subjects, using two same-day CT images, that the AEC technique in low-dose CT is reproducible within 10% and significantly depends on the patient centering.

60 APPLIED LIFE SCIENCES↗

SU-F-T-345: Quasi-Dead Beams: Clinical Relevance and Implications for Automatic Planning

Purpose: Beam direction selection for fixed-beam IMRT planning is typically a manual process. Severe dose-volume limits on critical structures in the thorax often result in atypical selection of beam directions as compared to other body sites. This work demonstrates the potential consequences as well as clinical relevance. Methods: 21 thoracic cases treated with 5–7 beam directions, 6 cases including non-coplanar arrangements, with fractional doses of 150–411cGy were analyzed. Endpoints included per-beam modulation scaling factor (MSF), variation from equal weighting, and delivery QA passing rate. Results: During analysis of patient-specific delivery QA a sub-standard passing rate was found for a single 5-field plan (90.48% of pixels evaluated passing 3% dose, 3mm DTA). During investigation it was found that a single beam demonstrated a MSF of 34.7 and contributed only 2.7% to the mean dose of the target. In addition, the variation from equal weighting for this beam was 17.3% absolute resulting in another beam with a MSF of 4.6 contributing 41.9% to the mean dose to the target; a variation of 21.9% from equal weighting. The average MSF for the remaining 20 cases was 4.0 (SD 1.8) with an average absolute deviation of 2.8% from equal weighting (SD 3.1%). Conclusion: Optimization in commercial treatment planning systems typically results in relatively equally weighted beams. Extreme variation from this can result in excessively high MSFs (very small segments) and potential decreases in agreement between planned and delivered dose distributions. In addition, the resultant beam may contribute minimal dose to the target (quasi-dead beam); a byproduct being increased treatment time and associated localization uncertainties. Potential ramifications exist for automatic planning algorithms should they allow for user-defined beam directions. Additionally, these quasi-dead beams may be embedded in the libraries for model-based systems potentially resulting in inefficient and less accurate deliveries.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs at 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: PLASTIMATCH MABS, an open source tool for automatic image segmentation

Purpose: Multiatlas based segmentation is largely used in many clinical and research applications. Due to its good performances, it has recently been included in some commercial platforms for radiotherapy planning and surgery guidance. Anyway, to date, a software with no restrictions about the anatomical district and image modality is still missing. In this paper we introduce PLASTIMATCH MABS, an open source software that can be used with any image modality for automatic segmentation. Methods: PLASTIMATCH MABS workflow consists of two main parts: (1) an offline phase, where optimal registration and voting parameters are tuned and (2) an online phase, where a new patient is labeled from scratch by using the same parameters as identified in the former phase. Several registration strategies, as well as different voting criteria can be selected. A flexible atlas selection scheme is also available. To prove the effectiveness of the proposed software across anatomical districts and image modalities, it was tested on two very different scenarios: head and neck (H&N) CT segmentation for radiotherapy application, and magnetic resonance image brain labeling for neuroscience investigation. Results: For the neurological study, minimum dice was equal to 0.76 (investigated structures: left and right caudate, putamen, thalamus, and hippocampus). For head and neck case, minimum dice was 0.42 for the most challenging structures (optic nerves and submandibular glands) and 0.62 for the other ones (mandible, brainstem, and parotid glands). Time required to obtain the labels was compatible with a real clinical workflow (35 and 120 min). Conclusions: The proposed software fills a gap in the multiatlas based segmentation field, since all currently available tools (both for commercial and for research purposes) are restricted to a well specified application. Furthermore, it can be adopted as a platform for exploring MABS parameters and as a reference implementation for comparing against other segmentation algorithms.

60 APPLIED LIFE SCIENCES↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Foundations of automatic feature extraction at LHC–point clouds and graphs

Abstract Deep learning algorithms will play a key role in the upcoming runs of the Large Hadron Collider (LHC), helping bolster various fronts ranging from fast and accurate detector simulations to physics analysis probing possible deviations from the Standard Model. The game-changing feature of these new algorithms is the ability to extract relevant information from high-dimensional input spaces, often regarded as “replacing the expert” in designing physics-intuitive variables. While this may seem true at first glance, it is far from reality. Existing research shows that physics-inspired feature extractors have many advantages beyond improving the qualitative understanding of the extracted features. In this review, we systematically explore automatic feature extraction from a phenomenological viewpoint and the motivation for physics-inspired architectures. We also discuss how prior knowledge from physics results in the naturalness of the point cloud representation and discuss graph-based applications to LHC phenomenology.

Bhardwaj, Akanksha↗

ASAP: Automatic Synthesis of Area-Efficient and Precision-Aware CGRAs

Coarse-grained reconfigurable accelerators (CGRAs) are a promising accelerator design choice that strikes a balance between performance and adaptability to different computing patterns across various applications domains. Designing a CGRA for a specific application domain involves enormous software/hardware engineering effort. Recent research works explore loop transformations, functional unit types, network topology, and memory size to identify optimal CGRA designs given a set of kernels from a specific application do- main. Unfortunately, the impact of functional units with different precision support has rarely been investigated. To address this gap, we propose ASAP – a hardware/software co-design framework that automatically identifies and synthesizes optimal precision-aware CGRA for a set of applications of interest. Our evaluation shows that ASAP generates specialized designs 3.2×, 4.21×, and 5.8× more efficient (in terms of performance per unit of energy or area) than non-specialized homogeneous CGRAs, for the scientific computing, embedded, and edge machine learning domains, respectively, with limited accuracy loss. Moreover, ASAP provides more efficient designs than other state-of-the-art synthesis frameworks for specialized CGRAs.

artificial intelligence↗

Auto-HPCnet: An Automatic Framework to Build Neural Network-based Surrogate for High-Performance Computing Applications

High-performance computing communities are increasingly adopt- ing Neural Networks (NN) as surrogate models in their applications to generate scientific insights. Replacing an execution phase in the application with NN models can bring significant performance im- provement. However, there is a lack of tools that can help domain scientists automatically apply NN-based surrogate models to HPC applications. We introduce a framework, named Auto-HPCnet, to democratize the usage of NN-based surrogates. Auto-HPCnet is the first end-to-end framework that makes past proposals for the NN-based surrogate model practical and disciplined. Auto-HPCnet introduces a workflow to address unique challenges when apply- ing the approximation, such as feature acquisition and meeting the application-specific constraint on the quality of final computation outcome. We show that Auto-HPCnet can leverage NN for a set of HPC applications and achieve 5.50× speedup on average (up to 16.8× speedup and with data preparation cost included) while meeting the application-specific constraint on the final computation quality.

Dong, Wenqian↗

Automatic Tool for Local Assembly Structures

Whole community shotgun sequencing of total DNA (i.e. metagenomics) and total RNA (i.e. metatranscriptomics) has provided a wealth of information in the microbial community structure, predicted functions, metabolic networks, and is even able to reconstruct complete genomes directly. Here we present ATLAS (Automatic Tool for Local Assembly Structures) a comprehensive pipeline for assembly, annotation, genomic binning of metagenomic and metatranscriptomic data with an integrated framework for Multi-Omics. This will provide an open source tool for the Multi-Omic community at large.

Source record↗

Automatic Compartments for Embedded Systems

ACES is a modified version of LLVM for ARMv7-M micro controllers that enables automatic application of compartments to bare-metal system code. It breaks the single monolithic binary of these systems into multiple execution domains using a developer selected policy. This increases the difficulty of compromising the entire system, as the data, code, and peripherals accessible at any given point in execution limited to the subset identified by the policy.

Clements, Abraham↗

Automatic Building Feature Extraction Toolkit (AutoBFE) v1.0

In recent years advances in the performance of machine learning methods have considerably improved the ability to accurately extract information from images. Identification of building characteristics from imagery is an example of an application that is time consuming and costly to perform manually, and where automatic feature extraction holds great promise. A major contribution of the work conducted in this project is the provision of open, transparent, and replicable solutions for buildings features extraction from images (e.g., satellite/aerial images). In this first version of the toolkit we are focussing on extracting building footprints from satellite/aerial images using state of the art deep learning image segmentation algorithms.

Touzani, Samir↗

Hydra Network Automatic Configuration (Hydra Autoconfig) v1

Hydra Autoconfig is an algorithm and software program to automatically configure a resilient network of independent ASICs that are capable of being connected as a Hydra network. The Hydra network itself is described in an invention disclosure titled: "Ad-Hoc Networks of Readout ASICs for Reliable Detector Instrumentation" (2020-091). The Hydra Autoconfig software works by first configuring a Hydra node. Then it recursively builds a Hydra network by attempting to link to each available upstream node in succession, keeping links that are verified. It then repeats on each newly generated node until no possible links remain. Once it is so configured, a reliable Hydra network of ASICs remains that can be reconfigured later to respond to damage or malfunction of one or more of the constituent ASICs.

Grace, Carl↗

Code Artifact for: Clustering Analysis of Commercial Vehicles Using Automatically Extracted Features from Time Series Data [SWR-21-96]

This repository contains data ingestion, feature extraction, and analysis code used in NREL Technical report "Clustering Analysis of Commercial Vehicles Using Automatically Extracted Features from Time Series Data." The code is written in Python. The ETL and feature extraction code must be run in a Spark context. The analysis code can be run without Spark, provided you have pre-computed features in a CSV file. Analysis code related to the NREL Technical Report NREL/TP-2C00-74212. Includes PySpark functions to perform trip segmentation and feature extraction over big time series data in Apache Spark. Includes "domain specific" features such as Aerodynamic Speed (ft/s), Characteristic Acceleration (ft/s2), Percent Below 55 (%), Percent Zero (%), Stops Per Mile, Average Speed (mph), Maximum Speed (mph), and Speed Standard Deviation (mph). Includes Pyspark UDF to compute "domain agnostic" features using the TSFresh library. This software record also includes the analysis notebooks and code to generate the results in the previously mentioned technical report.

Perr-Sauer, Jordan↗

Automatic Point Cloud Building Envelope Segmentation (AutoCuBES)

The Auto-CuBES algorithm is based on unsupervised machine learning that automatically labels 3D point cloud data and reduces the time spent in manual segmentation. The algorithm can process high-resolution point clouds and generate a wire-frame building envelope model with a small set of calibration parameters. The algorithm inputs a 3D point cloud generated by commonly available surveying equipment and outputs a wire-frame model of the building envelope. Unsupervised machine learning methods were used to identify facades, windows, and doors while minimizing the number of calibration parameters.

Puente, BryanMaldonado↗

Automatic Energy Calibration of Gamma-Ray Spectrometers

The software provides automatic method for calibrating the energy scale of high-purity germanium (HPGe) and scintillation gamma-ray spectrometers, using natural background radiation as the source of calibration gamma rays. In field gamma-ray spectroscopy, radioactive check sources may not be available; temperature changes can shift detector electronic gain and scintillator light output; and a user's experience and training may not include gamma-ray energy calibration. Hence, an automated method of calibrating the spectrometer using natural background would simplify its operation, especially by technician-level users, and by enhancing spectroscopic data quality, it would reduce false detections. Following a typically one-minute count of background gamma-rays, the measured spectrum is searched for gamma-ray peaks, producing a list of peak centroids, in channels1. Next, the ratio algorithm attempts to match the peak centroids found in the search to a user-supplied list of calibration gamma-ray energies. Finally, if three or more calibration energies have been matched to peaks, the energy equation parameters are determined by a least-squares fit2, and the spectrum has been energy-calibrated. The ratio algorithm rests on the repeatable but irregular spacing of the background gamma-ray energies together they form a unique set of ratios, when normalized to the highest energy calibration gamma ray; so too, the corresponding peak centroids in the spectrum. The algorithm matches energy ratios to peak centroid ratios, to determine which peak matches a given calibration energy.

Caffrey, Gus↗

Automatic Multiple Experiment Simulation and Fitting (Ames-Fit)

AMES-Fit is a program used to automatically fit the multi-field solid-state NMR spectra of half-integer quadrupolar nuclei. Due to the high dimensional space, gradient algorithms have failed to address the fitting of such data, which is at present done manually. AMES-Fit diverges from these approaches by using an adaptive step size random search algorithm to fit the NMR spectra to consistently find the global best fit parameters.

Perras, Frederic↗

Automatic software correction of residual aberrations in reconstructed HRTEM exit waves of crystalline samples

Abstract We develop an automatic and objective method to measure and correct residual aberrations in atomic-resolution HRTEM complex exit waves for crystalline samples aligned along a low-index zone axis. Our method uses the approximate rotational point symmetry of a column of atoms or single atom to iteratively calculate a best-fit numerical phase plate for this symmetry condition, and does not require information about the sample thickness or precise structure. We apply our method to two experimental focal series reconstructions, imaging a β-Si 3 N 4 wedge with O and N doping, and a single-layer graphene grain boundary. We use peak and lattice fitting to evaluate the precision of the corrected exit waves. We also apply our method to the exit wave of a Si wedge retrieved by off-axis electron holography. In all cases, the software correction of the residual aberration function improves the accuracy of the measured exit waves.

36 MATERIALS SCIENCE↗