Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Application characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A characterization of workflow management systems for extreme-scale applications

We present that the automation of the execution of computational tasks is at the heart of improving scientific productivity. Over the last years, scientific workflows have been established as an important abstraction that captures data processing and computation of large and complex scientific applications. By allowing scientists to model and express entire data processing steps and their dependencies, workflow management systems relieve scientists from the details of an application and manage its execution on a computational infrastructure. As the resource requirements of today’s computational and data science applications that process vast amounts of data keep increasing, there is a compelling case for a new generation of advances in high-performance computing, commonly termed as extreme-scale computing, which will bring forth multiple challenges for the design of workflow applications and management systems. This paper presents a novel characterization of workflow management systems using features commonly associated with extreme-scale computing applications. We classify 15 popular workflow management systems in terms of workflow execution models, heterogeneous computing environments, and data access methods. Finally, the paper also surveys workflow applications and identifies gaps for future research on the road to extreme-scale workflows and management systems.

97 MATHEMATICS AND COMPUTING↗

Comprehensive Characterization of Silicon Photomultipliers for Nuclear Security Applications

Scintillation detectors are an essential instrument in a variety of fields, serving as an effective means of detecting radiation for industrial, defense, medical, and basic-research applications. Light sensors are an integral part of all scintillation detectors and can affect detector performance as much as the scintillator itself. The photomultiplier tube (PMT) has been the standard light sensor for over half a century, but alternatives have been developed recently, and the silicon photomultiplier (SiPM) is perhaps the most promising of these new technologies. SiPMs can produce gains of the same order of magnitude as most PMTs and have shown reduced noise levels in the newest generations. Additionally, they posses benefits characteristic of solid-state devices such as insensitivity to magnetic fields, mechanical ruggedness, compactness, low operating voltages, and high quantum efficiencies. The timing properties of light sensors are an important characteristic for many applications, including nuclear security. For example, accurate timing is necessary for time of flight experiments, scatter cameras, and background suppression. This work aims to characterize the time resolution of many commercially available new-generation SiPMs, specifically in a time coincidence setting. SiPMs have been acquired from five leading manufacturers possessing a variety of pixel and microcell sizes. Results are presented with an organic scintillator p-terphenyl and coincidence time resolution of less than 300 picoseconds is achieved. Comparison with PMTs shows that the PMT pair tested has a superior time resolution of 83 picoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems

We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing secondary neutrons at BLIP for isotope production applications

Fast secondary neutrons created at the Brookhaven Linac Isotope Producer (BLIP) facility following proton irradiation were characterized by the foil activation technique and compared with FLUKA Monte Carlo simulations. The FLUKA-simulated neutron flux was spectrally adjusted following the maximum entropy formalism using the International Reactor Dosimetry and Fusion File (IRDFF-II), with predictions agreeing with experimental measurements to within 9 % following the adjustment procedure. Here, a multitude of degrader configurations were simulated to assess the feasibility of improving the fast (E n > 20 MeV) secondary neutron yield at the proposed neutron target position (“N-slot”). A configuration where the N-slot is closest to the proton degrader produced the highest fast neutron yield, with tungsten degraders achieving the best performance. Assuming the optimized target-degrader configuration proposed in this work, we discuss potential isotope production opportunities with secondary neutrons. In most cases the yields are in the order of several mCi.

07 ISOTOPE AND RADIATION SOURCES↗

Synthesis and characterization of ZnO nanostructured film for optoelectronic applications

ZnO nanostructured film is synthesized by solution combustion technique. X-ray diffraction (XRD) studies show that preferred orientation is along (101) confirming the hexagonal wurtzite phase and no secondary phase is observed. The rietveld refinement of the XRD data was used to calculate different lattice parameters. I-V characterization of ZnO film shows non linear behavior. These ZnO films are photosensitive, may be due to defect states. This property of these films can be utilized in optoelectronic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure–property relations in graphitic pebbles for nuclear applications

This work presents an analytical approach for holistically characterizing graphitic matrix pebbles for nuclear applications whereby the macrostructure, microstructure, and thermophysical properties of pebbles are determined. A systematic sectioning method was applied to several pebbles to describe the regional properties of the samples. Intact matrix-only spheres and sections of spheres fabricated by Kairos Power were characterized via optical imaging, x-ray computed tomography, x-ray diffraction, and ellipsometry to determine 2D and 3D macrostructure and anisotropy. The thermophysical properties of these materials were determined via measurements of density, specific heat, thermal expansion, and thermal diffusivity. The results of this study indicate that the pebble fabrication methods and their resultant effect on microstructure have a nontrivial effect on thermophysical properties, confirming the importance of robust characterization of these components. A discussion of the characterization approach and its applicability to nuclear fuel development activities is also included.

42 ENGINEERING↗

Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing

Purpose: Both the AccuBoost D-shaped and round applicators have been dosimetrically characterized and clinically used to treat patients with breast cancer. While the round applicators provide conformal dose coverage, under certain clinical circumstances the breast skin dose may be higher than preferred. The purpose of this study was to modify the round applicators to minimize skin dose while not substantially affecting dose uniformity within the target volume and reducing the treatment time. Methods: In order to irradiate the intended volume while sparing critical structures such as the skin, the current round applicator design has been augmented through the addition of an internal truncated cone (i.e., frustum) shield. Monte Carlo methods and clinical constraints were used to design the optimal cone applicator. With the cone applicator now defined as the entire assembly including the surrounding tungsten-alloy shell holding the HDR {sup 192}Ir source catheter, the applicator height was reduced to diminish the treatment time while minimizing skin dose. Monte Carlo simulation results were validated using both radiochromic film and ionization chamber measurements based on established techniques. Results: The optimal cone applicators diminished the maximum skin dose by 15%-32% (based on the applicator diameter and breast separation) with the tumor dose reduced by less than 3% for a constant exposure time. Furthermore, reduction in applicator height diminished the treatment time by up to 30%. Radiochromic film and ionization chamber dosimetric results in phantom agreed with Monte Carlo simulation results typically within 3%. Larger differences were outside the treatment volume in low dose regions or associated with differences between the measurement and Monte Carlo simulation environments. Conclusions: A new radiotherapy treatment device was developed and dosimetrically characterized. This set of applicators significantly reduces the skin dose and treatment time while retaining uniform target dose.

60 APPLIED LIFE SCIENCES↗

Physical and photoelectrochemical characterizations of hematite {alpha}-Fe{sub 2}O{sub 3}: Application to photocatalytic oxygen evolution

The physical properties and photoelectrochemical characterization of {alpha}-Fe{sub 2}O{sub 3}, synthesized by co-precipitation, have been investigated in regard to solar energy conversion. The optical gap is found to be 1.94 eV and the transition is indirectly allowed. The chemical analysis reveals an oxygen deficiency and the oxide exhibits n-type conductivity, confirmed by a negative thermopower. The plot log {sigma} vs 1/T shows linearity in the range (400-670 K) with the donor levels at 0.14 eV below the conduction band and a break at {proportional_to}590 K, attributed to the ionization of the donors. The conduction occurs by small polaron hopping through mixed valences Fe{sup 2+/3+} with an electron mobility {mu}{sub 400} {sub K} of 10{sup -3} V cm{sup 2} s{sup -1}. {alpha}-Fe{sub 2}O{sub 3} exhibits long term chemical stability in neutral solution and has been characterized photoelectrochemically to assess its activity as bias-free O{sub 2}-photoanode. The flat band potential V{sub fb} (-0.45V{sub SCE}) and the electron density N{sub D} (1.63 x 10{sup 18} cm{sup -3}) were determined, respectively, by extrapolating the linear part to C{sup -2} = 0 and the slope of the Mott Schottky plot. At pH 6.5, the valence band (+1.35V{sub SCE}) is suitably positioned with respect to the O{sub 2}/H{sub 2}O level (+0.62 V) and {alpha}-Fe{sub 2}O{sub 3} has been evaluated for the chemical energy storage through the photocatalytic reaction: (2SO{sub 3}{sup 2-}+2 H{sup +}{yields} S{sub 2} O{sub 3}{sup 2-}+ O{sub 2}+ H{sub 2} O, {delta}G = 213.36 kJ mol{sup -1}). The best photoactivity occurs in SO{sub 3}{sup 2-} solution (0.025 M, pH 8) with an oxygen rate evolution of 7.8 cm{sup 3} (g catalyst){sup -1} h{sup -1}. (author)

14 SOLAR ENERGY↗

Sci-Thur PM – Brachytherapy 01: Fast brachytherapy dose calculations: Characterization of egs-brachy features to enhance simulation efficiency

Purpose: egs-brachy is a fast, new EGSnrc user-code for brachytherapy applications. This study characterizes egs-brachy features that enhance simulation efficiency. Methods: Calculations are performed to characterize efficiency gains from various features. Simulations include radionuclide and miniature x-ray tube sources in water phantoms and idealized prostate, breast, and eye plaque treatments. Features characterized include voxel indexing of sources to reduce boundary checks during radiation transport, scoring collision kerma via tracklength estimator, recycling photons emitted from sources, and using phase space data to initiate simulations. Bremsstrahlung cross section enhancement (BCSE), uniform bremsstrahlung splitting (UBS), and Russian Roulette (RR) are considered for electronic brachytherapy. Results: Efficiency is enhanced by a factor of up to 300 using tracklength versus interaction scoring of collision kerma and by up to 2.7 and 2.6 using phase space sources and particle recycling respectively compared to simulations in which particles are initiated within sources. On a single 2.5 GHz Intel Xeon E5-2680 processor cor, simulations approximating prostate and breast permanent implant ((2 mm){sup 3} voxels) and eye plaque ((1 mm){sup 3}) treatments take as little as 9 s (prostate, eye) and up to 31 s (breast) to achieve 2% statistical uncertainty on doses within the PTV. For electronic brachytherapy, BCSE, UBS, and RR enhance efficiency by a factor >2000 compared to a factor of >10{sup 4} using a phase space source. Conclusion: egs-brachy features provide substantial efficiency gains, resulting in calculation times sufficiently fast for full Monte Carlo simulations for routine brachytherapy treatment planning.

60 APPLIED LIFE SCIENCES↗

Large aperture Fizeau interferometer commissioning and preliminary measurements of a long x-ray mirror at European X-ray Free Electron Laser

The European XFEL (X-ray Free Electron Laser) is a large facility under construction in Hamburg, Germany. It will provide a transversally fully coherent x-ray radiation with outstanding characteristics: high repetition rate (up to 2700 pulses with a 0.6 ms long pulse train at 10 Hz), short wavelength (down to 0.05 nm), short pulse (in the femtoseconds scale), and high average brilliance (1.6 ⋅ 10{sup 25} (photons s{sup −1} mm{sup −2} mrad{sup −2})/0.1% bandwidth). The beam has very high pulse energy; therefore, it has to be spread out on a relatively long mirror (about 1 m). Due to the very short wavelength, the mirrors need to have a high quality surface on their entire length, and this is considered very challenging even with the most advanced polishing methods. In order to measure the mirrors and to characterize their interaction with the mechanical mount, we equipped a metrology laboratory with a large aperture Fizeau interferometer. The system is a classical 100 mm diameter commercial Fizeau, with an additional expander providing a 300 mm diameter beam. Despite the commercial nature of the system, special care has been taken in the polishing of the reference flats and in the expander quality. We report the first commissioning of the instrument, its calibration, and performance characterization, together with some preliminary results with the measurement of a 950 mm silicon substrate. The intended application is to characterize the final XFEL mirrors with nanometer accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in High Resolution Ultrafast Scintillators for Fast timing Applications

Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV) and used in high frame rate applications. Here, we describe the advances in the development of thin-film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in a single crystalline form, these scintillators are bright, producing 115 000 photons/MeV. However, to achieve high spatial resolution, these scintillators are grown in thin-film form with a microcolumnar structure, controllable to column diameters of <1-30 mu m. Thus, a much thicker scintillator layer (10 mu m-3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 mu m or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Besides, we report timing measurements obtained using a photomultiplier tube (PMT) and oscilloscope at Radiation Monitoring Devices (RMD) Inc. Using the TR-XEOL, we determined the decay constants of LuI3 as a function of Ce doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications, where ultrahigh frame rates are important using synchrotron X-rays. This article will discuss fabrication, characterization, and potential applications for this novel scintillator.

fast timing↗

Characterizing U.S. Heat Demand Market for Potential Application of Geothermal Direct Use

In this paper, we assess the U.S. demand for low-temperature thermal energy at the county resolution for four major end-use sectors: residential buildings, commercial buildings, manufacturing facilities, and agricultural facilities. Existing, publicly available data on the U.S. thermal demand market are characterized by coarse spatial resolution, with assessments typically at the state-level or larger. For many uses, these data are sufficient; however, our research was motivated by an interest in assessing the potential demand for direct use (DU) of low-temperature (30 degrees to 150 degrees C) geothermal heat. The availability and quality of geothermal resources for DU applications are highly spatially heterogeneous; therefore, to assess the potential market for these resources, it is necessary to understand the spatial variation in demand for low-temperature resources at a local resolution. This paper presents the datasets and methods we used to develop county-level estimates of the thermal demand for the residential, commercial, manufacturing, and agricultural sectors. Although this analysis was motivated by an interest in geothermal energy deployment, the results are likely to have broader applications throughout the energy industry. The county-resolution thermal demand data developed in this study for four major U.S. sectors may have far-reaching implications for building technologies, industrial processes, and various distributed renewable energy thermal resources (e.g. biomass, solar).

15 GEOTHERMAL ENERGY↗

Frequency-shift vs phase-shift characterization of in-liquid quartz crystal microbalance applications

The improvement of sensitivity in quartz crystal microbalance (QCM) applications has been addressed in the last decades by increasing the sensor fundamental frequency, following the increment of the frequency/mass sensitivity with the square of frequency predicted by Sauerbrey. However, this sensitivity improvement has not been completely transferred in terms of resolution. The decrease of frequency stability due to the increase of the phase noise, particularly in oscillators, made impossible to reach the expected resolution. A new concept of sensor characterization at constant frequency has been recently proposed. The validation of the new concept is presented in this work. An immunosensor application for the detection of a low molecular weight contaminant, the insecticide carbaryl, has been chosen for the validation. An, in principle, improved version of a balanced-bridge oscillator is validated for its use in liquids, and applied for the frequency shift characterization of the QCM immunosensor application. The classical frequency shift characterization is compared with the new phase-shift characterization concept and system proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unraveling the impact of initial choices and in-loop interventions on learning dynamics in autonomous scanning probe microscopy

The current focus in Autonomous Experimentation (AE) is on developing robust workflows to conduct the AE effectively. This entails the need for well-defined approaches to guide the AE process, including strategies for hyperparameter tuning and high-level human interventions within the workflow loop. This paper presents a comprehensive analysis of the influence of initial experimental conditions and in-loop interventions on the learning dynamics of Deep Kernel Learning (DKL) within the realm of AE in scanning probe microscopy. We explore the concept of the “seed effect,” where the initial experiment setup has a substantial impact on the subsequent learning trajectory. Additionally, we introduce an approach of the seed point interventions in AE allowing the operator to influence the exploration process. Using a dataset from Piezoresponse Force Microscopy on PbTiO 3 thin films, we illustrate the impact of the “seed effect” and in-loop seed interventions on the effectiveness of DKL in predicting material properties. The study highlights the importance of initial choices and adaptive interventions in optimizing learning rates and enhancing the efficiency of automated material characterization. This work offers valuable insights into designing more robust and effective AE workflows in microscopy with potential applications across various characterization techniques.

47 OTHER INSTRUMENTATION↗

Extreme-scale scripting : opportunities for large task-parallel applications on petascale computers.

Parallel scripting is a loosely-coupled programming model in which applications are composed of highly parallel scripts of program invocations that process and exchange data via files. We characterize here the applications that can benefit from parallel scripting on petascale-class machines, describe the mechanisms that make this feasible on such systems, and present results achieved with parallel scripts on currently available petascale computers.

97 MATHEMATICS AND COMPUTING↗

Novel materials irradiation and pre-characterization plans for high-power targetry applications

The multi-megawatt proton beams that will be employed at future accelerator complexes introduce many new challenges for next-generation targetry systems, primarily due to the increased levels of beam-induced radiation damage combined with thermal shock effects during a beam pulse. Novel material classes, such as high-entropy alloys and electro-spun nanofibers are currently being investigated as materials that will be more tolerant of these effects in high beam power applications. Low-energy ion irradiation will be used for pre-screening and down selecting candidate novel materials prior to prototypic high-energy irradiation studies. Specific nano and micro-scale characterization techniques will be used to evaluate the radiation damage and thermal shock resistance of the new materials. Irradiation induced lattice spacing alteration and defect concentrations, as well as mechanical and thermal properties of the novel materials will be measured and compared to those of conventional targetry materials. This poster will detail plans for initial low-energy ion irradiation tests, and the post-irradiation examination techniques that will be used to develop and screen these novel target materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray solution scattering combined with computation characterizing protein folds and multiple conformational states : computation and application.

Small angle X-ray scattering (SAXS) is an increasingly powerful technique to characterize the structure of biomolecules in solution. We present a computational method for accurately and efficiently computing the solution scattering curve from a protein with dynamical fluctuations. The method is built upon a coarse-grained (CG) representation of the protein. This CG approach takes advantage of the low-resolution character of solution scattering. It allows rapid determination of the scattering pattern from conformations extracted from CG simulations to obtain scattering characterization of the protein conformational landscapes. Important elements incorporated in the method include an effective residue-based structure factor for each amino acid, an explicit treatment of the hydration layer at the surface of the protein, and an ensemble average of scattering from all accessible conformations to account for macromolecular flexibility. The CG model is calibrated and illustrated to accurately reproduce the experimental scattering curve of Hen egg white lysozyme. We then illustrate the computational method by calculating the solution scattering pattern of several representative protein folds and multiple conformational states. The results suggest that solution scattering data, when combined with a reliable computational method, have great potential for a better structural description of multi-domain complexes in different functional states, and for recognizing structural folds when sequence similarity to a protein of known structure is low. Possible applications of the method are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Status of Multiple Channel Fuel Performance Capabilities Within the SAS4A/SASSYS-1 Safety Analysis Software

SAS4A/SASSYS-1 (SAS) is a fast-running simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. It is a critical element of safety analysis capabilities for the U.S. Department of Energy and is utilized within industry to perform the transient safety analyses required to support the licensing of Liquid Metal-cooled Fast Reactors (LMFRs). Although SAS is exceptionally fast for most transient scenarios, fuel performance calculations, along with the associated pre-transient characterization of the fuel pin, may be required for transient scenarios where fuel pin failure is hypothesized. Both the pre-transient characterization and the transient fuel performance calculation are necessary to properly quantify margins to potential fuel failure and assess the time spent potentially exceeding such margins during events. While safety analysis calculations with fuel performance models provide a more detailed characterization of the reactor during a transient, the pre-transient characterization can be time-consuming and computationally expensive. Often, large numbers of fuel pins have been exposed to similar pre-transient irradiation conditions. Similarly, the same pre-transient fuel characterization may be applicable to numerous transient conditions. This provides an opportunity to optimize the SAS computational framework such that pre-transient fuel characterization can be shared across multiple channels (fuel pins) and across multiple simulations, thus dramatically reducing overall computational costs. This report summarizes progress toward enhancing the SAS computational framework to support shared, multiple channel fuel performance characterizations intended to significantly reduce computational costs. Preliminary testing has shown that the computational time saved by using the pre-transient sharing capability is approximately equal to the time it takes to perform the pre-transient characterization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗