Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

LeWRON: Agentic Analysis of Electroweak Phase Transitions

The electroweak phase transition (EWPT) is a central topic in particle physics and cosmology, connecting collider phenomenology, baryogenesis, and gravitational-wave observatories. Its analysis requires a technically demanding, convention-sensitive, and model-dependent pipeline, from constructing the finite-temperature effective potential to tracking thermal histories, computing bubble nucleation rates, and predicting gravitational-wave spectra. We present LeWRON (Learning ElectroWeak phase tRansitiON), an agentic framework that orchestrates this pipeline starting from an input Lagrangian. LeWRON combines audited toolbox construction with an Explorer module that uses the generated model-specific code for further analysis, including scans and plots. Intermediate analytic outputs are checked by auditor agents and stored as structured artifacts, enabling reproducible human inspection and downstream use through both a command-line interface and a public Python API. The framework supports a reproduction mode, which infers conventions from the literature and reproduces published results, and a discovery mode, which guides users through structured checkpoints for new models. We demonstrate LeWRON across representative beyond-the-Standard-Model scenarios and release the code on GitHub.

Wang, Isaac R. [Fermilab] (ORCID:000000030789218X)↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the Utility of Permethylated Polysaccharide Solution NMR Data for Characterization of Insoluble Plant Cell Wall Polysaccharides

Plant cell wall polysaccharide analysis encompasses the utilization of a variety of analytical tools, including gas and liquid chromatography, mass spectrometry (MS), and nuclear magnetic resonance (NMR) spectroscopy. These methods provide complementary data, which enable confident structural proposals of the many complex polysaccharide structures that exist in the complex matrices of plant cell walls. However, cell walls contain fractions of varying solubilities, and a few techniques are available that can analyze all fractions simultaneously. We have discovered that permethylation affords the complete dissolution of both soluble and insoluble polysaccharide fractions of plant cell walls in organic solvents such as chloroform or acetonitrile, which can then be analyzed by a number of analytical techniques including MS and NMR. In this work, NMR structure analysis of 10 permethylated polysaccharide standards was undertaken to generate chemical shift data providing insights into spectral changes that result from permethylation of polysaccharide residues. This information is of especial relevance to the structure analysis of insoluble polysaccharide materials that otherwise are not easily investigated by solution-state NMR methodologies. The preassigned NMR chemical shift data is shown to be vital for NMR structure analysis of minor polysaccharide components of plant cell walls that are particularly difficult to assign by NMR correlation data alone. With the assigned chemical shift data, we analyzed the permethylated samples of destarched, alcohol-insoluble residues of switchgrass and poplar by two-dimensional NMR spectral profiling. Thus, we identified, in addition to the major polysaccharide components, two minor polysaccharides, namely, <5% 3-linked arabinoxylan (switchgrass) and <2% glucomannan (poplar). In particular, the position of the arabinose residue in the arabinoxylan of the switchgrass sample was confidently assigned based on chemical shift values, which are highly sensitive to local chemical environments. Furthermore, the high resolution afforded by the 1H NMR spectra of the permethylated switchgrass and poplar samples allowed facile relative quantitative analysis of their polysaccharide composition, utilizing only a few milligrams of the cell wall material. As a result, the concepts herein developed will thus facilitate NMR structure analysis of insoluble plant cell wall polysaccharides, more so of minor cell wall components that are especially challenging to analyze with current methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis and design of insulation systems for LH2-fueled aircraft

An analytical program was conducted to evaluate the performance of 15 potential insulations for the fuel tanks of a subsonic LH2-fueled transport aircraft intended for airline service in the 1990-1995 time period. As a result, two candidate insulation systems are proposed for subsonic transport aircraft applications. Both candidates are judged to be the optimum available and should meet the design requirements. However, because of the long-life cyclic nature of the application and the cost sensitivity of airline operations, an experimental tank/insulation development or proof-of-concept program is recommended. This program should be carried out with a nearly full-scale system which would be subjected to the cyclic thermal and mechanical inputs anticipated in aircraft service.

Cunnington, G. R., Jr.↗

Dynamically tunable membrane metasurfaces for infrared spectroscopy and strong light-matter interactions

Mid-infrared spectroscopy enables biochemical sensing by identifying vibrational molecular fingerprints, but it faces limitations in instrumentation portability and analytical sensitivity. Optical metasurfaces with strong mid-infrared photonic resonances provide an attractive solution towards on-chip spectrometry and sensitive molecular detection, yet their static nature hinders their anticipated impact. Here, we introduce and demonstrate dynamically tunable silicon membrane metasurfaces exhibiting high-Q transmissive resonances in the fingerprint region. By harnessing silicon’s thermo-optical properties, we achieve continuous modulation of coupling-induced transparency (CIT) modes that emerge upon the interference of quasi-bound states in the continuum (q-BICs) and surface lattice modes (SLMs). We measure a spectral tuning rate of 0.06 cm −1 K −1 by continuously sweeping the sharp CIT resonances over a 23.5 cm −1 spectral range across a temperature range of 300–700 K. In the current proof‑of‑concept implementation, the dynamic transmission control enables non-contact chemical analysis of polymer films by detecting characteristic absorption bands of polystyrene (1450 and 1492 cm −1 ) and poly(methyl methacrylate) (1730 cm −1 ) without requiring conventional spectrometers. When analyte molecules fill the metasurface-generated photonic cavities, we demonstrate vibrational strong coupling between the poly(methyl methacrylate)’s carbonyl band and the CIT mode, manifested in a Rabi splitting of ~43 cm −1 . Our results establish a new photonic platform that unites spectral precision, strong field enhancement, and reconfigurability, offering diverse potential for compact mid-infrared spectroscopy, molecular sensing, and programmable polaritonic photonics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of Fundamental Modeling and Thermal Performance Issues for a Metallic Thermal Protection System Design

A study was performed to develop an understanding of the key factors that govern the performance of metallic thermal protection systems for reusable launch vehicles. A current advanced metallic thermal protection system (TPS) concept was systematically analyzed to discover the most important factors governing the thermal performance of metallic TPS. A large number of relevant factors that influence the thermal analysis and thermal performance of metallic TPS were identified and quantified. Detailed finite element models were developed for predicting the thermal performance of design variations of the advanced metallic TPS concept mounted on a simple, unstiffened structure. The computational models were also used, in an automated iterative procedure, for sizing the metallic TPS to maintain the structure below a specified temperature limit. A statistical sensitivity analysis method, based on orthogonal matrix techniques used in robust design, was used to quantify and rank the relative importance of the various modeling and design factors considered in this study. Results of the study indicate that radiation, even in small gaps between panels, can reduce significantly the thermal performance of metallic TPS, so that gaps should be eliminated by design if possible. Thermal performance was also shown to be sensitive to several analytical assumptions that should be chosen carefully. One of the factors that was found to have the greatest effect on thermal performance is the heat capacity of the underlying structure. Therefore the structure and TPS should be designed concurrently.

Blosser, Max L.↗

Updates to Relevance Vector Machine: Multiclass Classification, Variable Selection, and Proof-of-Concept Application to Safeguards Fresh Fuel Verification using List-Mode Neutron Collar Data

To expand the capabilities of safeguards authorities to verify the integrity of fresh fuel assemblies, Oak Ridge National Laboratory has retrofit the existing electronics of the JCC-71 uranium neutron coincidence collar, which contains 18 3 He neutron detectors and an external 241 AmLi(α, n) neutron interrogation source arranged to surround a fresh nuclear fuel assembly. The new electronics system allows analysts to record list-mode neutron multiplicity data in addition to the singles and doubles rates that are currently measured. Based on previous proof-of-concept research, analysis of these new data will identify off-normal fuel configurations in an assembly and characterize or localize the specific partial fuel defects. The purpose of this report it to document the analysis algorithm development and then to demonstrate its capability for the safeguards verification of fresh fuel assemblies using list mode neutron collar data. To analyze the complex list-mode data collected with the upgraded uranium neutron collar, multivariate classification algorithms are being developed using a novel classification method, the relevance vector machine. This approach may be applied to multiclass problems to estimate the probability that test data belongs to one of many possible classes of data. In addition, our method identifies the most useful variables/channels for making predictions, which illuminates the basis for the model’s predictions, and this interpretability is largely unique among data analytics methods. Variable selection occurs during model training and parameter tuning and does not need any external hyperparameter tuning routines. Finally, we apply the modified relevance vector machine to a simulated dataset of list-mode neutron collar data generated with the radiation transport code MCNP. The method can correctly identify off-normal fuel configurations, categorize the data according to four fuel defect scenarios, and rank the channels in the data according to prediction utility. For nuclear safeguards applications, it is concluded that this method has the potential to increase the sensitivity and reliability to detect missing fuel rods from a standard 17 x 17 Pressurized Water Reactor (PWR) fresh fuel assembly. Within this analysis, “off-normal” (i.e., missing fuel rods) were correctly classified in 17 simulated test scenarios with one quarter (25%) of the fresh fuel rods missing using a training data set of 58 simulated measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of inland boundary conditions on seawater intrusion modeling in stratified coastal aquifers under sea-level rise

This study systematically examines the impact of inland boundary conditions on seawater intrusion modeling in general stratified coastal aquifers under sea-level rise (SLR). We derived analytical solutions for seawater wedge toe positions in stratified aquifers with general head boundary (GHB) conditions and compiled solutions for constant head boundary (CHB), constant flux boundary (CFB), and GHB conditions in both homogeneous and stratified aquifers. Additionally, we introduced the concept of equivalent boundary conditions and developed equations to ensure consistent steady-state toe positions across different boundary types. Unlike previous studies focusing on specific layering configurations, we conducted a comprehensive sensitivity analysis of seawater intrusion in general stratified aquifers using transmissivity centroid elevation (TCE). Our results show that SLR generally exacerbates seawater intrusion, with unconfined aquifers exhibiting higher sensitivity across all boundary conditions. Among boundary types, CHB conditions were the most sensitive to SLR, CFB the least, and GHB showed an intermediate response depending on its distance from the model boundary. Furthermore, seawater intrusion increases with the TCE of the stratified aquifer under SLR, suggesting that high-permeability or preferential flow layers near the surface amplify the impact of SLR. These findings emphasize the importance of selecting appropriate boundary conditions when evaluating SLR-driven seawater intrusion in stratified coastal aquifers.

Boundary condition↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DFT and microkinetic comparison of Pt, Pd and Rh-catalyzed ammonia oxidation

Ammonia oxidation is the heart of the Ostwald process and is important in emissions control. Catalytic behaviors are a function of conditions and are observed to vary across the platinum group metals (PGMs) Pt, Pd, Rh. Here, we combine density functional theory computations and microkinetic modeling to rationalize these dependencies. We compute reactions over model (2 1 1) and (1 1 1) surfaces of PGMs. Binding energies are similar on Pd and Pt and generally greater on Rh, while activation energies vary across all metals. Rates on (2 1 1) surfaces are greater than (1 1 1) surfaces. Additionally, the stepped Pt is most active and stepped Rh most selective to N 2 at ammonia slip conditions, while at Ostwald process conditions, stepped Pd is most active and stepped Pt most selective to NO. Degree of rate and selectivity control analysis provides insights into the reactions limiting performance of PGMs. Both activation barriers and surface coverages influence rates and selectivities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reliability analysis of continuous fiber composite laminates

This paper describes two methods, the maximum distortion energy (MDE) and the principle of independent action (PIA), developed for the analysis of the reliability of a single continuous composite lamina. It is shown that, for the typical laminated plate structure, the individual lamina reliabilities can be combined in order to produce the upper and the lower bounds of reliability for the laminate, similar in nature to the bounds on properties produced from variational elastic methods. These limits were derived for both the interactive and the model failure considerations. Analytical expressions were also derived for the sensitivity of the reliability limits with respect to changes in the Weibull parameters and in loading conditions.

Thomas, David J.↗

Human Tracking Performance in Uncoupled and Coupled Two-Axis Systems

This report presents tile results of an experimental and analytical study of human performance in uncoupled and coupled control systems. Human pilot performance in single and two-axis systems was mathematically modeled by linear second-order describing functions. Model parameters were determined using model matching techniques. Analysis of the models showed that the amplitude ratio and phase lead of the describing function increased with training indicating an increase in open loop bandwidth. The phase margin also decreased with training. Increasing the plant lag time constant resulted in an increase in the model lead time constant and a decrease in the zero frequency gain. No significant difference was found to exist in the normalized tracking error per axis between the two-axis tasks and the single-axis tasks. However tile model lead time constant was significantly greater in two-axis tracking. Manual tracking of two-axis systems with cross-coupling was studied experimentally and analytically. Approximate methods for modeling two-axis performance were developed and checked using a precise spectral analysis approach. Coupled and uncoupled, symmetrical and asymmetrical two-axis performance was compared. The results show that modeling of cross-coupled systems is feasible and that trained subjects are capable of decoupling the axes of some systems. A methodology study compared the identification performance of continuous, iterative, and extrapolation model matching techniques. An iterative technique employing sensitivity equations for the generation of influence coefficients was found to be the best technique due to its excellent identification accuracy and ease of implementation. Convergence in iterative techniques can be improved substantially by equalizing the parameter adjustment rates and limiting the maximum correction per iteration.

Todosiev, E. P.↗

Ignition delay times of NH 3 /DME blends at high pressure and low DME fraction: RCM experiments and simulations

Here, autoignition delay times of ammonia/dimethyl ether (NH 3 /DME) mixtures were measured in a rapid compression machine with DME fractions of 0, 2 and 5 and 100% in the fuel. The measurements were performed at equivalence ratios $\varphi$= 0.5, 1.0 and 2.0 and pressures in the range 10–70 bar; depending on the fuel composition, the temperatures after compression varied from 610 K to 1180 K. Admixture of DME is seen to have a dramatic effect on the ignition delay time, effectively shifting the curves of ignition delay vs. temperature to lower temperatures, up to ~250 K compared to pure ammonia. Two-stage ignition is observed at $\varphi$= 1.0 and 2.0 with 2% and 5% DME in the fuel, despite the pressure being higher than that at which pure DME shows two-stage ignition. At $\varphi$= 0.5, a reproducible pre-ignition pressure rise is observed for both DME fractions, which is not observed in the pure fuel components. A novel NH 3 /DME mechanism was developed, including modifications in the NH 3 subset and addition of the NH 2 + CH 3 OCH 3 reaction, with rate coefficients calculated from ab initio theory. Simulations faithfully reproduce the observed pre- ignition pressure rise. While the mechanism also exhibits two-stage ignition for NH 3 /DME mixtures, both qualitative and quantitative improvement is recommended. The overall ignition delay times for ammonia/DME mixtures are predicted well, generally being within 50% of the experimental values, although reduced performance is observed for pure ammonia at $\varphi$= 2.0. Simulating the ignition process, we observe that the DME is oxidized much more rapidly than ammonia. Analysis of the mechanism indicates that this ‘early DME oxidation’ generates reactive species that initiate the oxidation of ammonia, which in turn begins heat release that raises the temperature and accelerates the oxidation process towards ignition. The reaction path analysis shows that the low-temperature chain-branching reactions of DME are important in the early oxidation of the fuel, while the sensitivity analysis indicates that several reactions in the oxidation of DME, including cross reactions between DME and NH 3 species presented here, are critical to ignition, even at fractions of 2% DME in the fuel.

10 SYNTHETIC FUELS↗

Performances of ionic liquid matrices with butyl ammonium counterion for matrix-assisted laser desorption/ionization mass spectrometric detection and analysis of sucralfate

In this work, the performances of two ionic liquid matrices (ILMs) with the same ammonium counterpart for mass spectrometric analysis of the insoluble and soluble sucralfate were compared. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) was performed assisted by the butylammonium salts of α-cyano-hydroxycinnamic acid (CHCAB) and 2,5-dihydroxybenzoic acid (DHBB). CHCAB has a higher IE than DHBB, but better optical properties. CHCAB is more suitable for the analysis of sucralfate, although molecular ions of both compounds were detectable only with low intensities. Thus, optical properties of ILMs are crucial to enhance the sensitivity of MALDI MS detection of polysulfated oligosaccharides. © 2019, © 2019 Taylor & Francis Group, LLC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of the optical parametric amplification phase on laser pulse compression

Optical parametric chirped-pulse amplification (OPCPA) is an effective way to generate ultrashort pulses that has been used extensively for a variety of applications requiring high peak intensities. Precise control and measurement of a system’s spectral and spatial phases are required for Fourier transform–limited pulse compression and diffraction-limited focusing. Phase accumulated during optical parametric amplification (OPA) can degrade the compressibility and focusability of the pulse, reducing peak intensity. We used analytic and numerical analysis of OPA to study the influence of crystal parameters, wavefront of the pump and signal, and their relative optical alignment on the accumulated phase. Here, we show that the accumulated signal phase is largely independent of amplifier saturation and, with significant local wavefront gradients in the signal or pump beam, the quality of the compressed pulses can be degraded. We use first-order expressions for the pump- and signal-angle sensitivity to evaluate an OPCPA system consisting of a highly deuterated potassium dihydrogen phosphate (DKDP) amplifier designed to support bandwidth for 15 fs pulses centered at 920 nm.

47 OTHER INSTRUMENTATION↗