Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANGLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Effects of injection angle orientation on concave and convex surfaces film cooling

The present study employs a transient liquid crystal thermography to measure film cooling performance over constant curvature of concave and convex surfaces. This work investigates detailed distributions of both film cooling effectiveness and heat transfer coefficient on concave and convex surfaces with one row of injection holes inclined stream-wise at 35 at four blowing ratios (0.5, 1.0, 1.5 and 2.0) on four test pieces with different hole configurations. All test models have a row of discrete holes with a stream-wise injection angle {gamma} of 35 and a pitch-to-diameter ratio (P/d) of 3. The current work examines four different injection configurations, one with simple and three with 8 forward-expanded holes. Three compound angles of 0, 45 and 90 with air ({rho}{sub c}/{rho}{sub m} = 0.98) as coolants are tested under the mainstream Reynolds number (Re{sub d}) of 2300 on concave surface, and 1700 on convex surface. Measured results of the concave surface show that both the span-wise averaged heat transfer coefficient and film cooling effectiveness increase with blowing ratios for all tested models. Higher heat transfer levels induced by large flow disturbance of compound-angle injection also lead to poorer overall film cooling performance, especially at high blowing ratio and large span-wise injection angle. Present results show that the best surface protection on the concave surface over the widest range of M can be provided by the forward-expanded holes with {beta} = 0 (Model-B), followed by the forward-expanded holes with {beta} = 45 (Model-C). Convex surface results show that the compound-angle injection indicates increases in both film cooling effectiveness and heat transfer at moderate and high blowing ratios. The forward-expanded hole with simple-angle injection provides the best film performance because of high film cooling effectiveness and low heat transfer coefficient at blowing ratio of 0.5. (author)

42 ENGINEERING↗

Modulation induced by very-large-scale motions on the inclination angle of wall-attached eddies: an atmospheric surface layer experiment

The forward leaning inclination angle, 𝛾, of coherent turbulent structures is a well-known feature of wall-bounded turbulent flows. Although invariant across friction Reynolds numbers within the range 𝑅𝑒 𝜏 =10 3 −10 6 , 𝛾 can vary significantly across turbulent scales within a high-Reynolds-number flow. Very-large-scale motions (VLSMs) are known to induce significant changes in the instantaneous shear profile, which is a conditioning event that could trigger variability in the inclination angle of smaller coherent turbulent structures. Although this aspect has been extensively studied via numerical and laboratory experiments, few studies have explored this feature for a very-high-Reynolds-number atmospheric flow. In this work, the inclination angle of turbulent structures within the atmospheric surface layer at a very high Reynolds number (𝑅𝑒 𝜏 =7.9 ×10 5 ) is investigated by deploying a scanning Doppler light detection and ranging and a super large particle image velocimetry (SLPIV) apparatus. The inclination angle of wall-attached eddies is inferred either from the two-point correlation of streamwise velocity (𝛾 =41.1∘) or with a scale-dependent approach through the spectral linear stochastic estimator (SLSE). The SLSE (and, thus, the scale-dependent inclination angle) is conditionally evaluated based on the high- and low-momentum events induced by VLSMs, both in the streamwise (𝑢′𝑉𝐿𝑆𝑀) and in the vertical (𝑤′ 𝑉𝐿𝑆𝑀) velocity components. As a result, lower inclination angles (𝛾 =30° −50°) are found for 𝑢$^{'}_{VLSM}$ >0 (𝑤$^{'}_{VLSM}$ <0), while higher values (50° −85°) are ascribed to 𝑢$^{'}_{VLSM}$ <0 (𝑤$^{'}_{VLSM}$ >0). This result emphasises the primary role that VLSMs play in shaping the wall-attached eddy geometry, which, in turn, is crucial to determine the Reynolds stress balance within the wall-attached eddy range.

42 ENGINEERING↗

Twist-angle dependence of moiré excitons in WS 2 /MoSe 2 heterobilayers

Moiré lattices formed in twisted van der Waals bilayers provide a unique, tunable platform to realize coupled electron or exciton lattices unavailable before. While twist angle between the bilayer has been shown to be a critical parameter in engineering the moiré potential and enabling novel phenomena in electronic moiré systems, a systematic experimental study as a function of twist angle is still missing. Here we show that not only are moiré excitons robust in bilayers of even large twist angles, but also properties of the moiré excitons are dependant on, and controllable by, the moiré reciprocal lattice period via twist-angle tuning. From the twist-angle dependence, we furthermore obtain the effective mass of the interlayer excitons and the electron inter-layer tunneling strength, which are difficult to measure experimentally otherwise. These findings pave the way for understanding and engineering rich moiré-lattice induced phenomena in angle-twisted semiconductor van der Waals heterostructures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Glancing angle sputter deposited nanostructures on rotating substrates: Experiments and simulations

Ordered arrays of Si nanorods and nanospirals have been produced by ion beam sputter glancing angle deposition of Si on rotating substrates. The substrates were prepatterned with honeycomb and hexagonal-closed-packed arranged Au dots obtained by nanosphere lithography. The effects of template type, substrate rotational speed, height of the artificial Au seeds, and deposition angle {theta} of the incident flux on the growth of the Si nanostructures is examined. Especially for the deposition of Si on honeycomb templates at different deposition angles, it is shown that the structure of the growing film changes drastically. A continuous film with honeycomblike arranged hillocks on top is deposited at normal incidence. With increased {theta}, the structure shifts to almost dense films with a mesh of hexagonally arranged pores ({theta}=70 deg.). Finally, separated rodlike structures with triangular cross section are obtained under glancing angle conditions ({theta}=85 deg.). In addition, the structural evolution of the glancing angle deposited Si films is compared with oblique angle deposition three-dimensional Monte Carlo simulations. Furthermore, the effects of surface diffusion on the growth of spiral Si nanostructures on nontemplated substrates in experiment and simulation are compared and discussed.

36 MATERIALS SCIENCE↗

Next Generation Angle Control for Medium Current and High Energy Implanters

Angle control continues to increase in importance with device scaling. For instance, threshold voltage and on-state current in advanced logic devices depend critically on the angle accuracy of medium current halo implants. TCAD simulation results, showing that on-state current changes of greater than 1% per degree of implant angle are possible, are presented. We report here on improvements to angle performance and control in both the horizontal and vertical directions. Beam data covering the full operating space of the VIISta 900XP is presented, demonstrating total angle control of better than {+-}0.2 deg. The data set is chosen to emphasize performance of typical halo implants. Single wafer high energy angle control data is also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the cross-phase angle between density and electron temperature fluctuations and comparison with gyrokinetic simulations

This paper presents new measurements of the cross-phase angle, alpha{sub n{sub eT{sub e}}}, between long-wavelength (k{sub t}hetarho{sub s}<0.5) density, n-tilde{sub e}, and electron temperature, T-tilde{sub e}, fluctuations in the core of DIII-D [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] tokamak plasmas. The coherency and cross-phase angle between n-tilde{sub e} and T-tilde{sub e} are measured using coupled reflectometer and correlation electron cyclotron emission diagnostics that view the same plasma volume. In addition to the experimental results, two sets of local, nonlinear gyrokinetic turbulence simulations that are performed with the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186, 545 (2003)] are described. One set, called the pre-experiment simulations, was performed prior to the experiment in order to predict a change in alpha{sub n{sub eT{sub e}}} given experimentally realizable increases in the electron temperature, T{sub e}. In the experiment the cross-phase angle was measured at three radial locations (rho=0.55, 0.65, and 0.75) in both a 'Base' case and a 'High T{sub e}' case. The measured cross-phase angle is in good qualitative agreement with the pre-experiment simulations, which predicted that n-tilde{sub e} and T-tilde{sub e} would be out of phase. The pre-experiment simulations also predicted a decrease in cross-phase angle as T{sub e} is increased. Experimentally, this trend is observed at the inner two radial locations only. The second set of simulations, the postexperiment simulations, is carried out using local parameters taken from measured experimental profiles as input to GYRO. These postexperiment simulation results are in good quantitative agreement with the measured cross-phase angle, despite disagreements with transport fluxes. Directions for future modeling and experimental work are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evanescent-wave coupled right angled buried waveguide: Applications in carbon nanotube mode-locking

We present an evanescent-field device based on a right-angled waveguide. This consists of orthogonal waveguides, with their points of intersection lying along an angled facet of the chip. Light guided along one waveguide is incident at the angled dielectric-air facet at an angle exceeding the critical angle, so that the totally internally reflected light is coupled into the second waveguide. By depositing a nanotube film on the angled surface, the chip is then used to mode-lock an Erbium doped fiber ring laser with a repetition rate of 26 MHz, and pulse duration of 800 fs.

36 MATERIALS SCIENCE↗

Measuring contact angle and meniscus shape with a reflected laser beam

Side-view imaging of the contact angle between an extended planar solid surface and a liquid is problematic. Even when aligning the view perfectly parallel to the contact line, focusing one point of the contact line is not possible. We describe a new measurement technique for determining contact angles with the reflection of a widened laser sheet on a moving contact line. We verified this new technique measuring the contact angle on a cylinder, rotating partially immersed in a liquid. A laser sheet is inclined under an angle φ to the unperturbed liquid surface and is reflected off the meniscus. Collected on a screen, the reflection image contains information to determine the contact angle. When dividing the laser sheet into an array of laser rays by placing a mesh into the beam path, the shape of the meniscus can be reconstructed from the reflection image. We verified the method by measuring the receding contact angle versus speed for aqueous cetyltrimethyl ammonium bromide solutions on a smooth hydrophobized as well as on a rough polystyrene surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PULSAR BINARY BIRTHRATES WITH SPIN-OPENING ANGLE CORRELATIONS

One ingredient in an empirical birthrate estimate for pulsar binaries is the fraction of sky subtended by the pulsar beam: the pulsar beaming fraction. This fraction depends on both the pulsar's opening angle and the misalignment angle between its spin and magnetic axes. The current estimates for pulsar binary birthrates are based on an average value of beaming fractions for only two pulsars, i.e., PSRs B1913+16 and B1534+12. In this paper, we revisit the observed pulsar binaries to examine the sensitivity of birthrate predictions to different assumptions regarding opening angle and alignment. Based on empirical estimates for the relative likelihood of different beam half-opening angles and misalignment angles between the pulsar rotation and magnetic axes, we calculate an effective beaming correction factor, f{sub b,eff}, whose reciprocal is equivalent to the average fraction of all randomly selected pulsars that point toward us. For those pulsars without any direct beam geometry constraints, we find that f{sub b,eff} is likely to be smaller than 6, a canonically adopted value when calculating birthrates of Galactic pulsar binaries. We calculate f{sub b,eff} for PSRs J0737-3039A and J1141-6545, applying the currently available constraints for their beam geometry. As in previous estimates of the posterior probability density function P(R) for pulsar binary birthrates R, PSRs J0737-3039A and J1141-6545 still significantly contribute to, if not dominate, the Galactic birthrate of tight pulsar-neutron star (NS) and pulsar-white dwarf (WD) binaries, respectively. Our median posterior present-day birthrate predictions for tight PSR-NS binaries, wide PSR-NS binaries, and tight PSR-WD binaries given a preferred pulsar population model and beaming geometry are 89 Myr{sup -1}, 0.5 Myr{sup -1}, and 34 Myr{sup -1}, respectively. For long-lived PSR-NS binaries, these estimates include a weak (x1.6) correction for slowly decaying star formation in the galactic disk. For pulsars with spin period between 10 ms and 100 ms, where few measurements of misalignment and opening angle provide a sound basis for extrapolation, we marginalized our posterior birthrate distribution P(R) over a range of plausible beaming correction factors. We explore several alternative beaming geometry distributions, demonstrating that our predictions are robust except in (untestable) scenarios with many highly aligned recycled pulsars. Finally, in addition to exploring alternative beam geometries, we also briefly summarize how uncertainties in each pulsar binary's lifetime and in the pulsar luminosity distribution can be propagated into P(R).

79 ASTRONOMY AND ASTROPHYSICS↗

THE DISTRIBUTION OF QUIET-SUN MAGNETIC FIELDS AT DIFFERENT HELIOCENTRIC ANGLES

This paper presents results from the analysis of high signal-to-noise ratio spectropolarimetric data taken at four heliocentric angles in quiet-Sun internetwork regions with the Hinode satellite. First, we find that the total circular and total linear polarization signals vary with heliocentric angle, at least for fields with large polarization signals. We also report changes on the Stokes V amplitude asymmetry histograms with viewing angle for fields weaker than 200 G. Then, we subject the data to a Milne-Eddington inversion and analyze the variation of the field vector probability density functions with heliocentric angle. Weak, highly inclined fields permeate the internetwork at all heliocentric distances. For fields weaker than 200 G, the distributions of field inclinations peak at 90 Degree-Sign and do not vary with viewing angle. The inclination distributions change for fields stronger than 200 G. We argue that the shape of the inclination distribution for weak fields partly results from the presence of coherent, loop-like magnetic features at all heliocentric distances and not from tangled fields within the field of view. We also find that the average magnetic field strength is about 180 G (for 75% of the pixels) and is constant with heliocentric angle. The average vertical and horizontal magnetic field components are 70 and 150 G. The latter (former) is slightly greater (smaller) near the limb. Finally, the ratio between the horizontal and vertical components of the fields ranges from {approx}1 for strong fields to {approx}3.5 for weak fields, suggesting that the magnetic field vector is not isotropically distributed within the field of view.

79 ASTRONOMY AND ASTROPHYSICS↗

Tidal evolution of the spin-orbit angle in exoplanetary systems

The angle between the stellar spin and the planetary orbit axes (the spin-orbit angle) is supposed to carry valuable information concerning the initial condition of planetary formation and subsequent migration history. Indeed, current observations of the Rossiter-McLaughlin effect have revealed a wide range of spin-orbit misalignments for transiting exoplanets. We examine in detail the tidal evolution of a simple system comprising a Sun-like star and a hot Jupiter adopting the equilibrium tide and the inertial wave dissipation effects simultaneously. We find that the combined tidal model works as a very efficient realignment mechanism; it predicts three distinct states of the spin-orbit angle (i.e., parallel, polar, and antiparallel orbits) for a while, but the latter two states eventually approach the parallel spin-orbit configuration. The intermediate spin-orbit angles as measured in recent observations are difficult to obtain. Therefore the current model cannot reproduce the observed broad distribution of the spin-orbit angles, at least in its simple form. This indicates that the observed diversity of the spin-orbit angles may emerge from more complicated interactions with outer planets and/or may be the consequence of the primordial misalignment between the protoplanetary disk and the stellar spin, which requires future detailed studies.

79 ASTRONOMY AND ASTROPHYSICS↗

ACTIVE-REGION TILT ANGLES: MAGNETIC VERSUS WHITE-LIGHT DETERMINATIONS OF JOY'S LAW

The axes of solar active regions are inclined relative to the east-west direction, with the tilt angle tending to increase with latitude ({sup J}oy's law{sup )}. Observational determinations of Joy's law have been based either on white-light images of sunspot groups or on magnetograms, where the latter have the advantage of measuring directly the physically relevant quantity (the photospheric field), but the disadvantage of having been recorded routinely only since the mid-1960s. White-light studies employing the historical Mount Wilson (MW) database have yielded tilt angles that are smaller and that increase less steeply with latitude than those obtained from magnetic data. We confirm this effect by comparing sunspot-group tilt angles from the Debrecen Photoheliographic Database with measurements made by Li and Ulrich using MW magnetograms taken during cycles 21-23. Whether white-light or magnetic data are employed, the median tilt angles significantly exceed the mean values, and provide a better characterization of the observed distributions. The discrepancy between the white-light and magnetic results is found to have two main sources. First, a substantial fraction of the white-light ''tilt angles'' refer to sunspots of the same polarity. Of greater physical significance is that the magnetograph measurements include the contribution of plage areas, which are invisible in white-light images but tend to have greater axial inclinations than the adjacent sunspots. Given the large uncertainties inherent in both the white-light and the magnetic measurements, it remains unclear whether any systematic relationship exists between tilt angle and cycle amplitude during cycles 16-23.

79 ASTRONOMY AND ASTROPHYSICS↗

Emission-angle and polarization-rotation effects in the lensed CMB

Lensing of the CMB is an important effect, and is usually modelled by remapping the unlensed CMB fields by a lensing deflection. However the lensing deflections also change the photon path so that the emission angle is no longer orthogonal to the background last-scattering surface. We give the first calculation of the emission-angle corrections to the standard lensing approximation from dipole (Doppler) sources for temperature and quadrupole sources for temperature and polarization. We show that while the corrections are negligible for the temperature and E-mode polarization, additional large-scale B-modes are produced with a white spectrum that dominates those from post-Born field rotation (curl lensing). On large scales about one percent of the total lensing-induced B-mode amplitude is expected to be due to this effect. However, the photon emission angle does remain orthogonal to the perturbed last-scattering surface due to time delay, and half of the large-scale emission-angle B modes cancel with B modes from time delay to give a total contribution of about half a percent. While not important for planned observations, the signal could ultimately limit the ability of delensing to reveal low amplitudes of primordial gravitational waves. We also derive the rotation of polarization due to multiple deflections between emission and observation. The rotation angle is of quadratic order in the deflection angle, and hence negligibly small: polarization typically rotates by less than an arcsecond, orders of magnitude less than a small-scale image rotates due to post-Born field rotation (which is quadratic in the shear). The field-rotation B modes dominate the other effects on small scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Classical phases and quantum angles in the description of interfering Bose-Einstein condensates

The interference of two Bose-Einstein condensates, initially in Fock states, can be described in terms of their relative phase, treated as a random unknown variable. This phase can be understood either as emerging from the measurements or pre-existing to them; in the latter case, the originating states could be phase states with unknown phases, so an average over all their possible values is taken. Both points of view lead to a description of probabilities of results of experiments in terms of a phase angle, which plays the role of a classical variable. Nevertheless, in some situations, this description is not sufficient: another variable, which we call the ''quantum angle,'' emerges from the theory. This article studies various manifestations of the quantum angle. We first introduce the quantum angle by expressing two Fock states crossing a beam splitter in terms of phase states and relate the quantum angle to off-diagonal matrix elements in the phase representation. Then we consider an experiment with two beam splitters, where two experimenters make dichotomic measurements with two interferometers and detectors that are far apart; the results lead to violations of the Bell-Clauser-Horne-Shimony-Holt inequality (valid for local-realistic theories, including classical descriptions of the phase). Finally, we discuss an experiment where particles from each of two sources are either deviated via a beam splitter to a side collector or proceed to the point of interference. For a given interference result, we find ''population oscillations'' in the distributions of the deviated particles, which are entirely controlled by the quantum angle. Various versions of population oscillation experiments are discussed, with two or three independent condensates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BICEP/ Keck XVIII: Measurement of BICEP3 polarization angles and consequences for constraining cosmic birefringence and inflation

We use a custom-made calibrator to measure individual detectors’ polarization angles of BICEP3, a small aperture telescope observing the cosmic microwave background (CMB) at 95 GHz from the South Pole. We describe our calibration strategy and the statistical and systematic uncertainties associated with the measurement. We reach an unprecedented precision for such measurement on a CMB experiment, with a repeatability for each detector pair of 0.02°. Here, we show that the relative angles measured using this method are in excellent agreement with those extracted from CMB data. Because the absolute measurement is currently limited by a systematic uncertainty, we do not derive cosmic birefringence constraints from BICEP3 data in this work. Rather, we forecast the sensitivity of BICEP3 sky maps for such analysis. We investigate the relative contributions of instrument noise, lensing, and dust, as well as astrophysical and instrumental systematics. We also explore the constraining power of different angle estimators, depending on analysis choices. We establish that the BICEP3 2-year dataset (2017–2018) has an on-sky sensitivity to the cosmic birefringence angle of 𝜎 𝛼 = 0.07⁢8°, which could be improved to 𝜎 𝛼 = 0.05⁢5° by adding all of the existing BICEP3 data (through 2023). Furthermore, we emphasize the possibility of using the BICEP3 sky patch as a polarization calibration source for CMB experiments, which with the present data could reach a precision of 0.035°. Finally, in the context of inflation searches, we investigate the impact of detector-to-detector variations in polarization angles as they may bias the tensor-to-scalar ratio 𝑟. We show that while the effect is expected to remain subdominant to other sources of systematic uncertainty, it can be reliably calibrated using polarization angle measurements such as the ones we present in this paper.

Cosmic microwave background↗

Exploring the Effects of Piston Bowl Geometry and Injector Included Angle on Dual-Fuel and Single-Fuel RCCI

Abstract Reactivity control compression ignition (RCCI) is a low-temperature combustion technique that has been proposed to meet the current demand for high thermal efficiency and low engine-out emissions. However, its requirement of two separate fuel systems (i.e., a low-reactivity fuel system and a high-reactivity fuel system) has been one of its major challenges in the last decade. This leads to the single-fuel RCCI concept, where the secondary fuel (reformates of diesel) is generated from the primary fuel (diesel) through catalytic partial oxidation reformation. Following the in-depth analysis of the reformate fuel (reformates of diesel) and its benefit as the low-reactivity fuel with diesel, the effects of the start of injection (SOI) timing of diesel and the energy-based blend ratio were also studied in detail. In this study, the effects of piston profile and the injector included angles were experimentally examined using both conventional fuel pairs (gasoline—diesel and natural gas—diesel) and reformate RCCI. A validated computational fluid dynamics (CFD) model was also used for a better understanding of the experimental trends. Comparing a reentrant bowl piston with a shallow bowl piston at a constant compression ratio and SOI, the latter showed better thermal efficiency, regardless of the fuel combination, due to its 10% lower surface area for the heat transfer. Comparing the 150-degree included angle and 60-degree included angle on the shallow bowl piston, the latter showed better combustion efficiency, regardless of the fuel combination, due to its earlier combustion phasing (at constant SOI timing). The effect was particularly prominent on reformate RCCI because of its incredibly high diluent concentration, which retards the combustion further for the 150-deg injector. Later, using convergecfd, seven different injector included angles were studied at a constant SOI. With the change in injector included angle, the region of the cylinder targeted by the fuel spray varies significantly, and it was found to have a significant impact on the combustion efficiency and the engine-out emissions. As the injector included angle changed from 60-deg to 150-deg, the combustion efficiency increased by 15% and the CO, NOx, and HC emissions decreased by 96%, 70%, and 86%, respectively.

Engineering↗

Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors

Purpose: Cardiac x-ray detectors are used to acquire moving images in real-time for angiography and interventional procedures. Detective quantum efficiency (DQE) is not generally measured on these dynamic detectors; the required “for processing” image data and control of x-ray settings have not been accessible. By 2016, USA hospital physicists will have the ability to measure DQE and will likely utilize the International Electrotechnical Commission (IEC) standard for measuring DQE of dynamic x-ray imaging devices. The current IEC standard requires an image of a tilted tungsten edge test object to obtain modulation transfer function (MTF) for DQE calculation. It specifies the range of edge angles to use; however, it does not specify a preferred method to determine this angle for image analysis. The study aimed to answer the question “will my choice in method impact my results?” Four different established edge angle determination methods were compared to investigate the impact on DQE. Methods: Following the IEC standard, edge and flat field images were acquired on a cardiac flat-panel detector to calculate MTF and noise power spectrum, respectively, to determine DQE. Accuracy of the methods in determining the correct angle was ascertained using a simulated edge image with known angulations. Precision of the methods was ascertained using variability of MTF and DQE, calculated via bootstrapping. Results: Three methods provided near equal angles and the same MTF while the fourth, with an angular difference of 6%, had a MTF lower by 3% at 1.5 mm{sup −1} spatial frequency and 8% at 2.5 mm{sup −1}; corresponding DQE differences were 6% at 1.5 mm{sup −1} and 17% at 2.5 mm{sup −1}; differences were greater than standard deviations in the measurements. Conclusions: DQE measurements may vary by a significant amount, depending on the method used to determine the edge angle when following the IEC standard methodology for a cardiac x-ray detector. The most accurate and precise methods are recommended for absolute assessments and reproducible measurements, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.

61 RADIATION PROTECTION AND DOSIMETRY↗