At least 415 records · Page 23

Exploring strain rate effects upon 3D materials using high speed in situ X-ray tomoscopy

Cellular materials are ubiquitous in our modern society. They may be stochastic gas-blown foams (e.g., polyurethane), foamed starches (e.g., cereals), or, in this case, 3D printed microlattices. Failure in these materials is often driven by surface or sub-surface defects, which may be nucleated at a surface roughness, an interior void, or inclusion interfaces that may not be typically observable. Obfuscating our understanding further, bulk materials are known to exhibit strain-rate-dependent mechanical response, making a subsurface understanding of damage even more critical. For the first time, an in situ uniaxial mechanical loading stage that simultaneously rotates specimens up to 18 Hz was fielded at a synchrotron for 3D tomographic imaging. This capability opens a plethora of materials science opportunities to explore strain rate effects in materials and examining deformation, fracture, and delamination’s (in composites) for a complete 3D picture (movie) of material response. We demonstrate the deformation of 3D printed polymer lattice structures, of three different material types, at 0.25, 1.1, and 2.2 s −1 strain rates. We successfully imaged the 3D deformation of these materials and can directly compare the same printed structure to the three material types at three strain rates, all in 3D. Material point method simulations were applied to one of the materials to better understand the role of voids on the 3D printed structure’s performance.

36 MATERIALS SCIENCE↗

Focused Electron Beam Induced Deposition Synthesis of 3D Photonic and Magnetic Nanoresonators

While many plasmonic phenomena have been realized by using standard nanoscale synthesis in a single 2-dimensional plane, enhanced functionality should be possible by extending into the third dimension. Several nanoscale synthesis approaches have been explored to achieve 3-dimensional (3d) geometries; however, a robust strategy for synthesizing complex 3d plasmonic architectures is lacking. In this study, we utilize a hybrid of direct-write 3d nanoprinting and thin film deposition to fabricate 3d plasmonic structures. Focused electron beam induced deposition (FEBID) is used to deposit nonplasmonic 3d scaffolds, which are subsequently isolated with a conformal SiO 2 layer and coated with a gold layer to create functional 3d plasmonic nanostructures. A variety of rod antennae, split-ring nanoresonators, and ring resonators are synthesized, and low-loss electron energy loss spectroscopy (EELS) is utilized to characterize their full plasmonic spectra with nanoscale resolution. Complementary EELS simulations are performed to interpret the spectra and elucidate the associated electric and magnetic field distributions of the infrared and near optical modes. This work demonstrates the flexibility that FEBID scaffolds offer for the advancement of 3d plasmonic devices and future advanced optical and magnetic metamaterials.

3d printing↗

High Throughput Screening of 3D Printable Resins: Adjusting the Surface and Catalytic Properties of Multifunctional Architectures

Identification of 3D printable materials is crucial to expand the breadth of physical and chemical properties attainable by additive manufacturing. Stereolithography (SLA), a widespread 3D printing method based on resin photopolymerization, is ideally suited for exploring a large variety of monomers to produce functional three-dimensional solids of diverse properties. However, for most commercial SLA printers, screening monomers and resin compositions requires large volumes (~150 mL) in each printing cycle, making the process costly and inefficient. Herein, a high throughput block (HTB) adaptor was developed to screen arrays of monomers and resin compositions, consuming lower volumes (<2 mL) and less time per print (<1/16 based on a 4 × 4 matrix) than using the original hardware. By use of this approach, a library of materials with different surface hydrophobicities were 3D printed by including long chain acrylates in the resins. In addition, several metal salts were dissolved in an acrylic acid-based resin, 3D printed, and screened as benzyl alcohol oxidation catalysts. Cu(II)-based resins produced the most active structures. Combinations of Cu(II) and long chain acrylate monomers were then used to 3D print complex catalytic architectures with varying degrees of hydrophobicity. Linear relationships were observed between 3D printed surface area, surface hydrophobicity, and catalyst performance. For a high surface Schwarz P topology ca. 60% enhancement in the catalytic activity of Cu(II) was attained by replacing the parent resin with one containing hydrophobic isodecyl groups, indicating that the immediate environment of the catalytic site affected its performance. The HTB enables fast screening of resins for 3D printing multifunctional architectures with intrinsic catalytic activity, tunable surface properties, and minimal waste.

36 MATERIALS SCIENCE↗

Surrogate models for plasma displacement and current in 3D perturbed magnetohydrodynamic equilibria in tokamaks

Abstract A numerical database of over one thousand perturbed three-dimensional (3D) equilibria has been generated, constructed based on the MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) computed plasma response to the externally applied 3D field sources in multiple tokamak devices. Perturbed 3D equilibria with the n = 1–4 ( n is the toroidal mode number) toroidal periodicity are computed. Surrogate models are created for the computed perturbed 3D equilibrium utilizing model order reduction (MOR) techniques. In particular, retaining the first few eigenstates from the singular value decomposition (SVD) of the data is found to produce reasonably accurate MOR-representations for the key perturbed quantities, such as the perturbed parallel plasma current density and the plasma radial displacement. SVD also helps to reveal the core versus edge plasma response to the applied 3D field. For the database covering the conventional aspect ratio devices, about 95% of data can be represented by the truncated SVD-series with inclusion of only the first five eigenstates, achieving a relative error (RE) below 20%. The MOR-data is further utilized to train neural networks (NNs) to enable fast reconstruction of perturbed 3D equilibria, based on the two-dimensional equilibrium input and the 3D source field. The best NN-training is achieved for the MOR-data obtained with a global SVD approach, where the full set of samples used for NN training and testing are stretched and form a large matrix which is then subject to SVD. The fully connected multi-layer perceptron, with one or two hidden layers, can be trained to predict the MOR-data with less than 10% RE. As a key insight, a better strategy is to train separate NNs for the plasma response fields with different toroidal mode numbers. It is also better to apply MOR and to subsequently train NNs separately for conventional and low aspect ratio devices, due to enhanced toroidal coupling of Fourier spectra in the plasma response in the latter case.

3D equilibrium↗

Snapshot 3D tracking of insulin granules in live cells

Rapid and accurate volumetric imaging remains a challenge, yet has the potential to enhance understanding of cell function. We developed and used a multifocal microscope (MFM) for 3D snapshot imaging to allow 3D tracking of insulin granules labeled with mCherry in MIN6 cells. MFM employs a special diffractive optical element (DOE) to simultaneously image multiple focal planes. This simultaneous acquisition of information deteunines the 3D location of single objects at a speed only limited by the array detector's frame rate. We validated the accuracy of MFM imaging/tracking with fluorescence beads; the 3D positions and trajectories of single fluorescence beads can be detelinined accurately over a wide range of spatial and temporal scales. The 3D positions and trajectories of single insulin granules in a 3.2um deep volume were deteunined with imaging processing that combines 3D decovolution, shift correction, and finally tracking using the Imaris software package. We find that the motion of the granules is super diffusive, but less so in 3D than 2D for cells grown on coverslip surfaces, suggesting an anisotropy in the cytoskeleton (e.g. microtubules and action).

3D tracking↗

Adapting CLUTCH methodology to multigroup TSUNAMI-3D for eigenvalue sensitivity calculations

The sensitivity of the eigenvalue to uncertainties in nuclear data and its evaluation are important for nuclear criticality safety. TSUNAMI-3D sequences within the SCALE code system offer several options to the user community for calculating eigenvalue sensitivity coefficients with multigroup (MG) and continuous energy (CE) 3D transport capabilities. TSUNAMI-3D sequences implement the adjoint-based perturbation theory with MG KENO code, the Contributon Linked eigenvalue sensitivity/Uncertainty estimation via Track length importance CHaracterization (CLUTCH) method with CE KENO code, and the Iterated Fission Probability (IFP) method with CE KENO and Shift codes. Each method has benefits and limitations depending on the problem that is run. The work presented here aims to adapt the CLUTCH method, which enables the Contributon method's mesh-free, memory-efficient approach for calculating adjoint-weighted tallies for sensitivity calculations, to the MG TSUNAMI-3D sequence. This application would eliminate the explicit adjoint KENO calculation, as well as the memory-consuming mesh flux moment tallies required by the conventional MG TSUNAMI-3D. Smaller memory footprints in the CLUTCH methodology and relatively shorter runtimes in MG KENO transport can make MG TSUNAMI-3D a viable method for some complex problems. Moreover, this adaptation allows MG sensitivity calculations with Shift, ORNL's next-generation high-performance Monte Carlo transport code, which currently does not offer any sensitivity capabilities with MG particle transport simulations. Initial implementation of the new MG TSUNAMI-3D sequence and its preliminary results with a selected critical benchmark experiment in the Verified, Archived Library of Inputs and Data (VALID) are presented in this study.

KENO↗

RELAP5-3D Developer Guidelines and Programming Practices

Our ultimate goal is to create and maintain RELAP5-3D as the best software tool available to analyze nuclear power plants. This begins with writing excellent programming and requires thorough testing. This document covers development of RELAP5-3D software, the behavior of the RELAP5-3D program that must be maintained, and code testing. RELAP5-3D must perform in a manner consistent with previous code versions with backward compatibility for the sake of the users. Thus file operations, code termination, input and output must remain consistent in form and content while adding appropriate new files, input and output as new features are developed. As computer hardware, operating systems, and other software change, RELAP5-3D must adapt and maintain performance. The code must be thoroughly tested to ensure that it continues to perform robustly on the supported platforms. The coding must be written in a consistent manner that makes the program easy to read to reduce the time and cost of development, maintenance and error resolution. The programming guidelines presented her are intended to institutionalize a consistent way of writing FORTRAN code for the RELAP5-3D computer program that will minimize errors and rework. A common format and organization of program units creates a unifying look and feel to the code. This in turn increases readability and reduces time required for maintenance, development and debugging. It also aids new programmers in reading and understanding the program. Therefore, when undertaking development of the RELAP5-3D computer program, the programmer must write computer code that follows these guidelines. This set of programming guidelines creates a framework of good programming practices, such as initialization, structured programming, and vector-friendly coding. It sets out formatting rules for lines of code, such as indentation, capitalization, spacing, etc. It creates limits on program units, such as subprograms, functions, and modules. It establishes documentation guidance on internal comments. The guidelines apply to both existing and new subprograms. They are written for both FORTRAN 77 and FORTRAN 95. The guidelines are not so rigorous as to inhibit a programmer’s unique style, but do restrict the variations in acceptable coding to create sufficient commonality that new readers will find the coding in each new subroutine familiar. It is recognized that this is a “living” document and must be updated as languages, compilers, and computer hardware and software evolve.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experiments in 3D Printing Electric Motors

This paper catalogues a series of experiments we conducted to explore how to 3D print a DC electric motor. The individual parts of the electric motor were 3D printed but assembled by hand. First, we focused on a rotor with soft magnetic properties, for which we adopted ProtoPasta TM , which is a commercial off-the-shelf PLA filament incorporating iron particles. Second, we focused on the stator permanent magnets, which were 3D printed through binder jetting. Third, we focused on the wire coils, for which we adopted a form of laminated object manufacture of copper wire. The chief challenge was in 3D printing the coils, because the winding density is crucial to the performance of the motor. We have demonstrated that DC electric motors can be 3D printed and assembled into a functional system. Although the performance was poor due to the wiring problem, we showed that the other 3D printing processes were consistent with high performance. Nevertheless, we demonstrated the principle of 3D printing electric motors.

3D printed motor↗

3D Construction of Biologically Derived Materials

System for the 3D Construction of Biologically Derived Materials, Structures, and Parts NASA has developed a novel approach for macroscale biomaterial production by combining synthetic biology with 3D printing. Cells are biologically engineered to deposit desired materials, such as proteins or metals, derived from locally available resources. The bioengineered cells build different materials in a specified 3D pattern to produce novel microstructures with precise molecular composition, thickness, print pattern, and shape. Scaffolds and reagents can be used for further control over material product. This innovation provides modern design and fabrication techniques for custom-designed organic or organic-inorganic composite biomaterials produced from limited resources. Benefits Conserves resources. Few raw or bulk starting materials needed Enables custom design of diverse materials Fast, portable, macroscale, on-demand manufacturing High-fidelity microstructures Uses commercially available parts Applications Biomaterials, biotechnology Organic-inorganic composite materials On-demand manufacturing In situ resource utilization Space stations Military Infrastructure materials The Technology Once genes for a desired material type, delivery mode, control method and affinity have been chosen, assembling the genetic components and creating the cell lines can be done with well-established synthetic biology techniques. A 3D microdeposition system is used to make a 3D array of these cells in a precise, microstructure pattern and shape. The engineered cells are suspended in a printable 'ink'. The 3D microdeposition system deposits minute droplets of the cells onto a substrates surface in a designed print pattern. Additional printer passes thicken the material. The cell array is fed nutrients and reagents to activate the engineered genes within the cells to create and deposit the desired molecules. These molecules form the designed new material. If desired, the cells may be removed by flushing. The end product is thus a 3D composite microstructure comprising the novel material. This innovation provides a fast, controlled production of natural, synthetic, and novel biomaterials with minimum resource overhead and reduced pre- and post-processing requirements.

3D↗

3D Carbon Coating Enabled High‐capacity and Stable Micro‐sized Silicon Suboxide‐graphite Blended Anodes for Practical Lithium‐ion Batteries

Abstract Silicon oxide (SiO x ) is a promising anode candidate of lithium‐ion batteries (LIBs) owing to its extremely high specific capacity. However, the low initial Coulombic efficiency (ICE) and rapid capacity degradation of SiO x , triggered by the enormous volume variation upon repeated (de)lithiation, gravely hinder its practical use. Herein, two mass‐produced micro‐sized SiO x @C composites with obviously different morphologies for commercial LIBs are reported. Particularly, the SiO x ‐graphite blended anode (SiO x @3D‐G‐Gr) based on SiO x wrapped by three‐dimensional (3D) carbon layers (SiO x @3D‐G) exhibits a capacity of 519 mAh g −1 , an ICE of 90.0 % and a capacity retention of 83.4 % at 0.2 C over 100 cycles. which is far exceeding its counterpart SiO x @C‐H‐Gr (65.7 %). The obtained impressive properties of SiO x @3D‐G originate from the critical contribution of 3D carbon layers, which serves as the effective stress buffer and protective layer as well as the strong networks for electron/Li + transport. Accordingly, the full‐cell based on SiO x @3D‐G‐Gr anode and commercial LiCoO 2 cathode delivers a capacity of 803 mAh and an excellent capacity retention of 95.6 % (616 mAh, 96.6 % for graphite, respectively) at 1 C over 100 cycles with a stabilized CE of nearly 100 %. The micro‐sized SiO x @3D‐G showing a promising prospect in the commercial‐grade anodes in LIBs.

Electrochemistry↗

Material property characterization of 3D printed polypropylene wood plastic composites

Abstract Wood flour (WF) at 10 wt.% and 20 wt.% loadings was used as a reinforcing filler to enhance the applicability of polypropylene (PP) for 3D printing. After performing printability tests of PP wood plastic composites (WPCs), the mechanical properties of both injection‐molded and 3D‐printed PP WPC specimens were explored. Test specimens were prepared from 3D printed hexagons for analyzing the mechanical properties. Adding WF to neat PP increased the storage modulus and the glass transition temperature while decreasing the degree of crystallinity and the coefficient of thermal expansion, while enhancing the printability of neat PP. The tensile strength, tensile modulus of elasticity, flexural strength, and flexural modulus of elasticity of injection‐molded neat PP improved by up to 21%, 59%, 30%, and 56%, respectively, with 20 wt.% WF. However, the impact strength of injection‐molded neat PP decreased by 85%, with 20 wt.% WF. After 3D printing, the tensile strength and tensile modulus of elasticity of printed neat PP increased by up to 84% and 60%, respectively, with 20 wt.% WF. The flexural strength and flexural modulus of elasticity of neat printed PP remained unchanged compared to those of PP filled with 20 wt.% WF, while the impact strength decreased by 87%. Highlights WF was used as a reinforcement in polypropylene designed for 3D printing A pilot‐scale, pellet‐fed 3D printer was used to print hollow hexagons, and then test specimens were fabricated from these hexagons for mechanical properties The tensile and flexural properties of 3D printed neat polypropylene improved, while the impact strength decreased after adding 20 wt.% WF to the neat PP.

Hwang, Sungjun↗

Second spectrum of Chromium (Cr II), Part II: Radiative lifetimes and oscillator strengths of transitions depopulating low lying 3d{sup 4}4p levels

Radiative lifetime and oscillator strength values were computed by means of a pseudo-relativistic Hartree–Fock model including core-polarization and compared successfully with experimental data given in the literature for respectively numerous low-lying Cr II 3d{sup 4}4p levels, up to 54784 cm{sup −1}, and transitions depopulating these levels. Then transition probability and branching fraction data were also deduced in the wavelength range 1825–94400 Å. Furthermore the extracted radial integral values, obtained with the help of the oscillator strength parameterization method, are given for involved transitions in this work, i.e. 3d{sup 4}4s–3d{sup 4}4p, 3d{sup 5}–3d{sup 4}4p and 3d{sup 4}4p–3d{sup 4}4d. We confirm our observed previous general trends, noting once again a decreasing of transition radial integral values with filling nd shells of the same principal quantum numbers for nd{sup k}(n+1)s → nd{sup k}(n+1)p transitions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Modelling the development of capillary pressure in freshly 3D-printed concrete elements

3D concrete printing is a promising technology recently developed to automate construction. Since no formwork is used in this technology to support and protect fresh concrete, there are two aspects which considerably accelerate the development of capillary pressure in 3D-printed concrete in comparison to conventionally placed concrete: i) high stiffness of 3D-printed needed to provide sufficient buildability, and ii) very early and fast evaporation of pore water. Accelerated development of capillary pressure may lead to severe plastic shrinkage cracking in 3D-printed elements and, hence, need to be mitigated. This investigation aims at providing a poromechanical model for capillary pressure development in 3D-printed elements. To simulate the development of capillary pressure and plastic shrinkage, environmental factors, material properties, and element geometry need to be considered as a whole. The model inputs – coefficient of permeability, static bulk modulus, air entry pressure and chemical shrinkage rate – were determined experimentally. The model was validated for two fine-grained concretes. Both 3D-printed materials yielded faster capillary pressure increase in comparison to cast concrete, while partial substitution of cement with silica fume further accelerated the capillary pressure development. Furthermore, due to the lower permeability of the mixture containing silica fume, the gradient of capillary pressure between 3D-printed layers increased, as did the gradient of plastic shrinkage.

36 MATERIALS SCIENCE↗

Hierarchical reconstruction of 3D well-connected porous media from 2D exemplars using statistics-informed neural network

The relationships between porous microstructures and transport properties are of fundamental importance in various scientific and engineering applications. Due to the intricacy, stochasticity and heterogeneity of porous media, reliable characterization and modeling of transport properties often require a complete dataset of internal microstructure samples. However, it is often an unbearable cost to acquire sufficient 3D digital microstructures by purely using microscopic imaging systems. Herein this paper presents a machine learning-based technique to hierarchically reconstruct 3D well-connected porous microstructures from one isotropic or several anisotropic low-cost 2D exemplar(s). To compactly characterize the large-scale microstructural features, a Gaussian image pyramid is built for each 2D exemplar. Local morphology patterns are collected from the Gaussian image pyramids, and then they serve as the training data to embed the 2D morphological statistics into feed-forward neural networks at multiple length levels. By using a specially-developed morphology integration scheme, the 3D morphological statistics at different levels can be inferred from the statistics-informed neural networks. Gibbs sampling is adopted to hierarchically reconstruct 3D microstructures by using multi-level 3D morphological statistics, where the large-scale, regional and local morphological patterns are statistically generated and successively added to the same 3D random field. The proposed method is tested on a series of porous media with distinct morphologies, and the statistical equivalence between the reconstructed and the real microstructures is systematically evaluated by comparing morphological descriptors and transport properties. The results demonstrate that the proposed 2D-to-3D microstructure reconstruction method is a universal and efficient approach to generating morphologically and physically realistic samples of porous media.

42 ENGINEERING↗

Intensity-Modulated and 3D-Conformal Radiotherapy for Whole-Ventricular Irradiation as Compared With Conventional Whole-Brain Irradiation in the Management of Localized Central Nervous System Germ Cell Tumors

Purpose: To compare the sparing potential of cerebral hemispheres with intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for whole-ventricular irradiation (WVI) and conventional whole-brain irradiation (WBI) in the management of localized central nervous system germ cell tumors (CNSGCTs). Methods and Materials: Ten cases of patients with localized CNSGCTs and submitted to WVI by use of IMRT with or without a 'boost' to the primary lesion were selected. For comparison purposes, similar treatment plans were produced by use of 3D-CRT (WVI with or without boost) and WBI (opposed lateral fields with or without boost), and cerebral hemisphere sparing was evaluated at dose levels ranging from 2 Gy to 40 Gy. Results: The median prescription dose for WVI was 30.6 Gy (range, 25.2-37.5 Gy), and that for the boost was 16.5 Gy (range, 0-23.4 Gy). Mean irradiated cerebral hemisphere volumes were lower for WVI with IMRT than for 3D-CRT and were lower for WVI with 3D-CRT than for WBI. Intensity-modulated radiotherapy was associated with the lowest irradiated volumes, with reductions of 7.5%, 12.2%, and 9.0% at dose levels of 20, 30, and 40 Gy, respectively, compared with 3D-CRT. Intensity-modulated radiotherapy provided statistically significant reductions of median irradiated volumes at all dose levels (p = 0.002 or less). However, estimated radiation doses to peripheral areas of the body were 1.9 times higher with IMRT than with 3D-CRT. Conclusions: Although IMRT is associated with increased radiation doses to peripheral areas of the body, its use can spare a significant amount of normal central nervous system tissue compared with 3D-CRT or WBI in the setting of CNSGCT treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Radiotherapy Techniques (IMRT vs. 3D-CRT) on Outcome in Patients With Intermediate-Risk Rhabdomyosarcoma Enrolled in COG D9803-A Report From the Children's Oncology Group

Purpose: To compare the dosimetric parameters of intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) in patients with intermediate-risk rhabdomyosarcoma and to analyze their effect on locoregional control and failure-free survival (FFS). Methods and Materials: The study population consisted of 375 patients enrolled in the Children's Oncology Group protocol D9803 study, receiving IMRT or 3D-CRT. Dosimetric data were collected from 179 patients with an available composite plan. The chi-square test or Fisher's exact test was used to compare the patient characteristics and radiotherapy parameters between the two groups. The interval-to-event outcomes were estimated using the Kaplan-Meier method and compared using log-rank tests. Cox proportional hazards regression analysis was used to examine the effect of the treatment technique on FFS after adjusting for primary site and risk group. Results: The median follow-up time was 5.7 and 4.2 years for patients receiving 3D-CRT and IMRT, respectively. No differences in the 5-year failure of locoregional control (18% vs. 15%) or FFS (72% vs. 76%) rates were noted between the two groups. Multivariate analysis revealed no association between the two techniques and FFS. Patients with primary tumors in parameningeal sites were more likely to receive IMRT than 3D-CRT. IMRT became more common during the later years of the study. Patients receiving IMRT were more likely to receive >50 Gy, photon energy of {<=}6 MV, and >5 radiation fields than those who received 3D-CRT. The coverage of the IMRT planning target volume by the prescription dose was improved compared with the coverage using 3D-CRT with similar target dose heterogeneity. Conclusions: IMRT improved the target dose coverage compared with 3D-CRT, although an improvement in locoregional control or FFS could not be demonstrated in this population. Future studies comparing the integral dose to nontarget tissue and late radiation toxicity between the two groups are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Modulation Arc Radiotherapy With Flattening Filter-Free Beams Compared With Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: A Feasibility Study

Purpose: A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving {>=}95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving {>=}5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics. Results: RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 {+-} 0.1 for RA and IMRT and 1.5 {+-} 0.2 for 3D-CRT. The mean lung dose was 12.2 {+-} 4.5 for IMRT, 11.3 {+-} 4.6 for RA, and 10.8 {+-} 4.4 for RA with FFF beams, 18.2 {+-} 8.5 for 3D-CRT. The percentage of volume receiving {>=}20 Gy ranged from 23.6% {+-} 9.1% to 21.1% {+-} 9.7% for IMRT and RA (FFF beams) and 39.2% {+-} 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 {+-} 139, 322 {+-} 20, and 387 {+-} 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a {approx}20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different gantry speeds). Conclusion: RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skin-sparing Helical Tomotherapy vs 3D-conformal Radiotherapy for Adjuvant Breast Radiotherapy: In Vivo Skin Dosimetry Study

Purpose: We investigated whether treatment-planning system (TPS)-calculated dose accurately reflects skin dose received for patients receiving adjuvant breast radiotherapy (RT) with standard three-dimensional conformal RT (3D-CRT) or skin-sparing helical tomotherapy (HT). Methods and Materials: Fifty patients enrolled in a randomized controlled trial investigating acute skin toxicity from adjuvant breast RT with 3D-CRT compared to skin-sparing HT, where a 5-mm strip of ipsilateral breast skin was spared. Thermoluminescent dosimetry or optically stimulated luminescence measurements were made in multiple locations and were compared to TPS-calculated doses. Skin dosimetric parameters and acute skin toxicity were recorded in these patients. Results: With HT there was a significant correlation between calculated and measured dose in the medial and lateral ipsilateral breast (r = 0.67, P<.001; r = 0.44, P=.03, respectively) and the medial and central contralateral breast (r = 0.73, P<.001; r = 0.88, P<.001, respectively). With 3D-CRT there was a significant correlation in the medial and lateral ipsilateral breast (r = 0.45, P=.03; r = 0.68, P<.001, respectively); the medial and central contralateral breast (r = 0.62, P=.001; r = 0.86, P<.001, respectively); and the mid neck (r = 0.42, P=.04, respectively). On average, HT-calculated dose overestimated the measured dose by 14%; 3D-CRT underestimated the dose by 0.4%. There was a borderline association between highest measured skin dose and moist desquamation (P=.05). Skin-sparing HT had greater skin homogeneity (homogeneity index of 1.39 vs 1.65, respectively; P=.005) than 3D-CRT plans. HT plans had a lower skin{sub V50} (1.4% vs 5.9%, respectively; P=.001) but higher skin{sub V40} and skin{sub V30} (71.7% vs 64.0%, P=.02; and 99.0% vs 93.8%, P=.001, respectively) than 3D-CRT plans. Conclusion: The 3D-CRT TPS more accurately reflected skin dose than the HT TPS, which tended to overestimate dose received by 14% in patients receiving adjuvant breast RT.