Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “2D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Solvent-mediated carboxylic acid diammonium spacer for synthesizing FA-based 2D Dion–Jacobson perovskites toward efficient solar cells

Two-dimensional (2D) perovskites are promising for photovoltaic applications due to their outstanding optical properties and better environmental stability compared to three-dimensional (3D) perovskites. Unlike 2D Ruddlesden–Popper (RP) perovskites, which use monovalent ammonium spacers, Dion–Jacobson (DJ) perovskites employ divalent organic spacers that enhance structural stability by mitigating weak van der Waals interactions. However, the random phase distribution and disorder crystal orientation in 2D DJ perovskites create deep quantum wells, hindering charge transfer and reducing short-circuit current density (J SC ) and overall photovoltaic performance. This study introduces an organic diammonium, 1,4-butanediamine diacetate (BDAAc 2 ), to replace the traditional halide spacer 1,4-butanediamine iodide (BDADI 2 ). This substitution regulates perovskites crystallization dynamics, reducing compositional disorder and random phase distribution, thus improving the quality of the perovskite films. The robust coordination interactions between BDAAc 2 and the perovskite inorganic framework lead to an ordered [PbX 6 ] 4− arrangement, suppressing the formation of complex intermediate phases and significantly enhancing δ phase crystallinity in the intermediate film. This results in a high yield of high-quality α phase. Consequently, the resulting 2D DJ perovskite solar cells based on BDAFA 3 Pb 4 (I 0.9 Br 0.1 ) 13 achieve a higher power conversion efficiency of 16.41% and an elevated J SC of 20.46 mA cm −2 .

14 SOLAR ENERGY↗

Algorithm to extract direction in 2D discrete distributions and a continuous Frobenius norm

In this study, we present a novel algorithm for determining directionality in 2D distributions of discrete data. We compare a reference dataset with a known direction to a measured dataset with an unknown direction by the Frobenius norm of the difference (FND) to find the unknown direction. To generalize this concept, we develop a continuous Frobenius norm of the difference (CFND) as a continuous analog of the FND and derive its analytical expression. By relating fitted and normalized 2D Gaussian distributions, we show that the CFND approximates the FND, and we validate this relationship with computer simulations. We find that a first-order approximation of the CFND between two similar Gaussian distributions takes the form of an absolute sine function, offering a simple analytical form with potential applications in specialized areas such as segmented inverse beta decay neutrino detectors, astronomy, machine learning, and more. Our methodology consists of modeling a 2D Gaussian distribution, binning the data into a histogram, and encoding it as a square matrix. Rotating this matrix around its geometric center and comparing it to a measured dataset using the FND gives us rotational data that we fit with an absolute sine function. The location of the minimum of this fit is the angle closest to the true angle of the direction in the measured dataset. We present the derivation and discuss initial applications of the CFND in our novel algorithm, demonstrating its success in approximating directionality in 2D distributions.

Physics↗

2D microspatial distribution uniformity of photon detection efficiency and crosstalk probability of multi-pixel photon counters

Two-dimensional (2D) microspatial distribution uniformity of photon detection efficiency (PDE) and optical crosstalk probability P{sub ct} of multi-pixel photon counters (MPPCs) is studied. The experimental results show that the 2D spatial distribution of P{sub ct} is obviously uneven, i.e. P{sub ct} is larger at the corners and edges of a single pixel in MPPCs, which suggest a higher electrical field in the depletion region of the pixel at the corners and edges. The nonuniformity of the 2D spatial distribution of PDE also become evident when the size of the pixels of MPPCs is small, which signifies higher nonuniformity of the electric field distribution in MPPCs with small pixel size. A method is proposed for characterization of the 2D electrical field spatial distribution uniformity in a single pixel of MPPCs, which can be used for guiding the optimisation of the fabrication process of MPPCs and their properties. This promising method can naturally be extended to any Geiger avalanche photodiodes (G-APDs) and their arrays. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2D MHD AND 1D HD MODELS OF A SOLAR FLARE—A COMPREHENSIVE COMPARISON OF THE RESULTS

Without any doubt, solar flaring loops possess a multithread internal structure that is poorly resolved, and there are no means to observe heating episodes and thermodynamic evolution of the individual threads. These limitations cause fundamental problems in numerical modeling of flaring loops, such as selection of a structure and a number of threads, and an implementation of a proper model of the energy deposition process. A set of one-dimensional (1D) hydrodynamic and two-dimensional (2D) magnetohydrodynamic models of a flaring loop are developed to compare energy redistribution and plasma dynamics in the course of a prototypical solar flare. Basic parameters of the modeled loop are set according to the progenitor M1.8 flare recorded in AR 10126 on 2002 September 20 between 09:21 UT and 09:50 UT. The nonideal 1D models include thermal conduction and radiative losses of the optically thin plasma as energy-loss mechanisms, while the nonideal 2D models take into account viscosity and thermal conduction as energy-loss mechanisms only. The 2D models have a continuous distribution of the parameters of the plasma across the loop and are powered by varying in time and space along and across the loop heating flux. We show that such 2D models are an extreme borderline case of a multithread internal structure of the flaring loop, with a filling factor equal to 1. Nevertheless, these simple models ensure the general correctness of the obtained results and can be adopted as a correct approximation of the real flaring structures.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparing 1.5D ONETWO and 2D SOLPS analyses of inter-ELM H-mode plasma in DIII-D

A DIII-D inter-ELM H-mode plasma that is in approximate transport equilibrium is analysed with the 1.5D ONETWO core code and the 2D SOLPS code. In order to investigate the importance of core-edge coupling and 2D effects, including divertor fuelling across the X-point and poloidal asymmetries that are not explicitly included in ONETWO, the domain of SOLPS is extended to very near the magnetic axis. Two principal objectives are (1) to determine whether poloidal asymmetries in the plasma distributions are large enough to vitiate a core-type interpretive plasma transport analysis and (2) to determine whether the interpretive transport coefficients and neutral beam power and particle sources from ONETWO, when used in 2D SOLPS full plasma simulations, yield the same quality fits to the measured upstream density and temperature profiles as obtained with ONETWO. Results show that only a small increase in the separatrix value of the particle diffusion coefficient, and no change in the thermal diffusivities from ONETWO was needed to get excellent agreement of the upstream SOLPS density and temperature profiles and the Thomson scattering and CER data. Good agreement of the ONETWO and SOLPS flux surface averaged distributions of the core electron and D+ densities and temperatures are also obtained. Likewise the C6+ density, with a simple chemical sputtering model based on a constant fraction of the divertor D+ flux, the core heat and particle fluxes and the neutral density reveal no 2D effects in the core/pedestal region that would vitiate a 1.5D treatment of the inter-ELM H-mode plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broad background in electron diffraction of 2D materials as a signature of their superior quality

Abstract An unusually broad bell-shaped component (BSC) has been previously observed in surface electron diffraction on different types of 2D systems. It was suggested to be an indicator of uniformity of epitaxial graphene (Gr) and hexagonal boron nitride (hBN). In the current study we use low-energy electron microscopy and micro-diffraction to directly relate the BSC to the crystal quality of the diffracting 2D material. Specially designed lateral heterostructures were used to map the spatial evolution of the diffraction profile across different 2D materials, namely pure hBN, BCN alloy and pure Gr, where the alloy region exhibits deteriorated structural coherency. The presented results show that the BSC intensity has a minimum in the alloyed region, consequently showing that BSC is sensitive to the lateral domain size and homogeneity of the material under examination. This is further confirmed by the presence of a larger number of sharp moiré spots when the BSC is most pronounced in the pure hBN and Gr regions. Consequently, it is proposed that the BSC can be used as a diagnostic tool for determining the quality of the 2D materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An open-endcap blade trap for radial-2D ion crystals

We present the design and experimental demonstration of an open-endcap radio frequency trap to confine ion crystals in the radial-two dimensional (2D) structural phase. The central axis of the trap is kept free of obstructions to allow for site-resolved imaging of ions in the 2D crystal plane, and the confining potentials are provided by four segmented blade electrodes. We discuss the design challenges, fabrication techniques, and voltage requirements for implementing this open-endcap trap. Finally, we validate its operation by confining up to 29 ions in a 2D triangular lattice, oriented such that both in-plane principal axes of the 2D crystal lie in the radial direction.

74 ATOMIC AND MOLECULAR PHYSICS↗

2024 roadmap on 2D topological insulators

Abstract 2D topological insulators promise novel approaches towards electronic, spintronic, and quantum device applications. This is owing to unique features of their electronic band structure, in which bulk-boundary correspondences enforces the existence of 1D spin–momentum locked metallic edge states—both helical and chiral—surrounding an electrically insulating bulk. Forty years since the first discoveries of topological phases in condensed matter, the abstract concept of band topology has sprung into realization with several materials now available in which sizable bulk energy gaps—up to a few hundred meV—promise to enable topology for applications even at room-temperature. Further, the possibility of combining 2D TIs in heterostructures with functional materials such as multiferroics, ferromagnets, and superconductors, vastly extends the range of applicability beyond their intrinsic properties. While 2D TIs remain a unique testbed for questions of fundamental condensed matter physics, proposals seek to control the topologically protected bulk or boundary states electrically, or even induce topological phase transitions to engender switching functionality. Induction of superconducting pairing in 2D TIs strives to realize non-Abelian quasiparticles, promising avenues towards fault-tolerant topological quantum computing. This roadmap aims to present a status update of the field, reviewing recent advances and remaining challenges in theoretical understanding, materials synthesis, physical characterization and, ultimately, device perspectives.

Weber, Bent (ORCID:000000018586127X)↗

0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator

We have conducted 0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator (IMG) []. The 0D calculations were conducted with a four-element circuit model; the 1D, 2D, and 3D calculations were conducted with highly resolved, fully electromagnetic representations. The IMG consists of 30 stages distributed axially and connected electrically in series. Each stage is powered by two bricks separated by 180° and connected electrically in parallel. Each brick comprises two opposite-polarity capacitors in series with a single switch. The bricks drive an internal impedance-matched coaxial transmission line terminated by a resistive load. The simulations neglect effects due to the switch-triggering circuit, the capacitor-charging circuit, external conducting boundaries, and reactive components of the load. We find dimensionality does not significantly affect the electrical power delivered by the IMG to its load: peak load powers estimated by the 0D, 1D, 2D, and 3D simulations agree to within 1%. The 3D calculations demonstrate that electromagnetic power radiated by the bricks, and axial gaps between stages, reduces the peak load power by less than ∼ 1 % . Each simulation assumes the load impedance is 34% above that at which the load power is maximized. Operating an IMG with such an overmatched load offers several advantages while decreasing the peak load power by only 2%. The 0D, 1D, 2D, and 3D models outlined herein could be adapted to assess computationally competing IMG designs, and conduct a variety of numerical IMG experiments, an IMG is constructed. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Emulating 2D Materials with Magnons

Spin waves (magnons) in two-dimensional (2D) materials have received increasing interest due to their unique states and potential for tunability. However, many interesting features of these systems, including Dirac points and topological states, occur at high frequencies, where experimental probes are limited. Here, we study a crystal formed by patterning a hexagonal array of holes in a perpendicularly magnetized thin film. Through simulation, we find that the magnonic band structure imitates that of graphene, but additionally has some kagomelike character and includes a few flat bands. Surprisingly, its nature can be understood using a nine-band tight-binding Hamiltonian. This clear analogy to 2D materials enables band-gap engineering in 2D, topological magnons along 1D phase boundaries, and spectrally isolated modes at 0D point defects. Interestingly, the 1D phase boundaries allow access to the valley degree of freedom through a magnonic analog of the quantum valley Hall insulator. These approaches can be extended to other magnonic systems, but are potentially more general due to the simplicity of the model, which resembles existing results from electron, phonon, photon, and cold-atom systems. This finding brings the physics of spin waves in 2D materials to more experimentally accessible scales, augments it, and outlines a few principles for controlling magnonic states.

Ferrimagnets↗

Machine learning approaches for crystallographic classification from synthetic 2D X-ray diffraction data

Crystallographic structure identification is crucial for understanding material properties; however, current methodologies often depend on labor-intensive and time-consuming analyses of 2D X-ray diffraction (XRD) patterns. To address these limitations, this study employs synthetic 2D XRD patterns combined with deep learning (DL) techniques to enable automated and high-throughput classification of the seven crystal systems and 230 space groups. We introduce the novel Auto Diffraction Pipeline, designed to generate synthetic 2D XRD spot patterns from crystallographic information files under diverse conditions, including varying zone axes, atomic substitution, atomic depletion and mechanical loading. These conditions enhance the realism of synthetic data, mitigating the scarcity of experimental datasets and enabling the creation of large representative training sets. Convolutional neural networks were trained and validated on these synthetic datasets to classify crystallographic structures across multiple scenarios. Our results demonstrate that integrating synthetic 2D XRD patterns with DL facilitates rapid, accurate and automated crystallographic classification, promoting the wider adoption of data-driven approaches in materials science.

Shahnazari, Ayoub [Univ. of Rochester, NY (United ↗

PyXAS – an open-source package for 2D X-ray near-edge spectroscopy analysis

In the synchrotron X-ray community, X-ray absorption near-edge spectroscopy (XANES) is a widely used technique to probe the local coordination environment and the oxidation states of specific elements within a sample. Although this technique is usually applied to bulk samples, the advent of new synchrotron sources has enabled spatially resolved versions of this technique (2D XANES). This development has been extremely powerful for the study of heterogeneous systems, which is the case for nearly all real applications. However, associated with the development of 2D XANES comes the challenge of analyzing very large volumes of data. As an example, a single 2D XANES measurement at a synchrotron can easily produce ~106 spatially resolved XANES spectra. Conventional manual analysis of an individual XANES spectrum is no longer feasible. Here, a software package is described that has been developed for high-throughput 2D XANES analysis. A detailed description of the software as well as example applications are provided.

25 ENERGY STORAGE↗

End-to-end orientation estimation from 2D cryo-EM1images

Cryo-electron microscopy (cryo-EM) is a Nobel Prize-winning technique for deter-mining high-resolution 3D structures of biological macromolecules. A 3D structure is reconstructed from hundreds of thousands of noisy 2D projection images. However, existing 3D reconstruction methods are still time-consuming, and one of the major computational bottlenecks is to recover the unknown orientation of the particle in16each 2D image. The dominant methods typically exploit expensive global search on each image to estimate the missing orientations. Here, a novel end-to-end supervised learning method is introduced to directly recover the missing orientations from 2D cryo-EM images. A neural network is used to approximate the mapping from images to orientations. Furthermore, a robust loss function is proposed for optimizing the parameters of the network, which can handle both asymmetric and symmetric 3D structures. Experiments on synthetic datasets with various symmetry types confirm that the neural network is capable of recovering orientations from 2D cryo-EM images, and the results on one real cryo-EM dataset further demonstrate its potential in more challenging imaging conditions.

3D reconstruction↗

2D photonic crystal layer assisted thiosilicate ceramic plate with red-emitting film for high quality w -LEDs

In this work, we have succeeded in obtaining high quality warm w-light-emitting-diodes (LEDs) by adopting hybrid two-dimensional (2D) structure of SiNx photonic crystal layer (PCL) assisted cyan-emitting ceramic-plate thiosilicate SrLa2Si2S8:Ce3+ with red-emitting film SrLiAl3N4:Eu2+ phosphor on a 430 nm blue LED chip at 350 mA. 2D SiNx PCL was capped with thiosilicate is because it can enhance the luminous efficacy and maintain the low correlated color temperature (CCT) and high color-rendering index (CRI). High luminous efficacy (82.3 lm/W), high special CRI (R9=75) as well as the low CCT (5431 K) of the optimal w-LED was obtained due to the assistances of 2D SiNx PCL and narrow-band red-emitting phosphor with the doping percentage at 10 wt%. The synthesis processes, structural analysis, optical properties and LED device performances were detailed investigated to find out the relationship between the optimum composition and good optical properties. Based on intriguing luminescence properties by the 2D SiNx PCL and red-emitting film phosphor introducing, we proclaim this method could also have high potential application in other phosphor-converted w-LEDs.

36 MATERIALS SCIENCE↗

Automatic 3D-to-2D registration for CT and dual-energy digital radiography for calcification detection

We are investigating three-dimensional (3D) to two-dimensional (2D) registration methods for computed tomography (CT) and dual-energy digital radiography (DEDR). CT is an established tool for the detection of cardiac calcification. DEDR could be a cost-effective alternative screening tool. In order to utilize CT as the 'gold standard' to evaluate the capability of DEDR images for the detection and localization of calcium, we developed an automatic, intensity-based 3D-to-2D registration method for 3D CT volumes and 2D DEDR images. To generate digitally reconstructed radiography (DRR) from the CT volumes, we developed several projection algorithms using the fast shear-warp method. In particular, we created a Gaussian-weighted projection for this application. We used normalized mutual information (NMI) as the similarity measurement. Simulated projection images from CT values were fused with the corresponding DEDR images to evaluate the localization of cardiac calcification. The registration method was evaluated by digital phantoms, physical phantoms, and clinical data sets. The results from the digital phantoms show that the success rate is 100% with a translation difference of less than 0.8 mm and a rotation difference of less than 0.2 deg. . For physical phantom images, the registration accuracy is 0.43{+-}0.24 mm. Color overlay and 3D visualization of clinical images show that the two images registered well. The NMI values between the DRR and DEDR images improved from 0.21{+-}0.03 before registration to 0.25{+-}0.03 after registration. Registration errors measured from anatomic markers decreased from 27.6{+-}13.6 mm before registration to 2.5{+-}0.5 mm after registration. Our results show that the automatic 3D-to-2D registration is accurate and robust. This technique can provide a useful tool for correlating DEDR with CT images for screening coronary artery calcification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, the similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels

Purpose: Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. Methods: Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 ''Reference'' images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 ''Test'' patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. Results: The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2{+-}3.9% (Right lung=88.8%; Left lung=89.6%) and 89.3{+-}2.7% (Right=88.5%; Left=90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p<0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL:p=0.43; Dice:p=0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. Conclusions: The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multichannel response analysis on 2D projection views for detection of clustered microcalcifications in digital breast tomosynthesis

Purpose: To investigate the feasibility of a new two-dimensional (2D) multichannel response (MCR) analysis approach for the detection of clustered microcalcifications (MCs) in digital breast tomosynthesis (DBT). Methods: With IRB approval and informed consent, a data set of two-view DBTs from 42 breasts containing biopsy-proven MC clusters was collected in this study. The authors developed a 2D approach for MC detection using projection view (PV) images rather than the reconstructed three-dimensional (3D) DBT volume. Signal-to-noise ratio (SNR) enhancement processing was first applied to each PV to enhance the potential MCs. The locations of MC candidates were then identified with iterative thresholding. The individual MCs were decomposed with Hermite–Gaussian (HG) and Laguerre–Gaussian (LG) basis functions and the channelized Hotelling model was trained to produce the MCRs for each MC on the 2D images. The MCRs from the PVs were fused in 3D by a coincidence counting method that backprojects the MC candidates on the PVs and traces the coincidence of their ray paths in 3D. The 3D MCR was used to differentiate the true MCs from false positives (FPs). Finally a dynamic clustering method was used to identify the potential MC clusters in the DBT volume based on the fact that true MCs of clinical significance appear in clusters. Using two-fold cross validation, the performance of the 3D MCR for classification of true and false MCs was estimated by the area under the receiver operating characteristic (ROC) curve and the overall performance of the MCR approach for detection of clustered MCs was assessed by free response receiver operating characteristic (FROC) analysis. Results: When the HG basis function was used for MCR analysis, the detection of MC cluster achieved case-based test sensitivities of 80% and 90% at the average FP rates of 0.65 and 1.55 FPs per DBT volume, respectively. With LG basis function, the average FP rates were 0.62 and 1.57 per DBT volume at the same sensitivity levels. The difference in the two sets of basis functions for detection of MCs did not show statistical significance. Conclusions: The authors' experimental results indicate that the MCR approach is promising for the detection of MCs on PV images. The HG or LG basis functions are both effective in characterizing the signal response of MCs using the channelized Hotelling model. The coincidence counting method for fusion of the 2D MCR in 3D is an important step for FP reduction. Further study is underway to improve the MCR approach for microcalcification detection in DBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗