SEARCH · Engineering Papers
Results for “water efficiency”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
How Well Do U.S. Western Water Markets Convey Economic Information?
An efficient market implies that potential gains from trade are fully captured. Achieving this requires a well-functioning market where prices reflect all available information. In the case of water rights markets, this implies that the permanent water rights transfer price reflects the sum of discounted returns to this asset (i.e., the lease price), the market interest rate, and a risk premium that reflects potential future water scarcity. Here, the purpose of this study is to assess the efficiency of western U.S. water markets by using the asset pricing model to measure how well prices reflect long-run returns to permanent water rights.
Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation
The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.
Proton Conducting Silicon Oxide Membranes as a Fluorine Free Alternative to Nafion for Low Temperature Water Electrolysis
Driven by environmental and health concerns related to per- and polyfluoroalkyl substances (PFAS), there has been growing interest in developing fluorine-free proton (H + ) exchange membrane (PEM) materials for fuel cells and water electrolyzers. In this study, we present a side-by-side comparison of the key transport properties of submicron thick, PFAS-free amorphous silicon dioxide (SiO 2 ) membranes to Nafion, a fluorinated polymer electrolyte membrane that represents the industry standard for PEM fuel cells and electrolyzers. Here, measurements of proton (H + ) conductivity (σ H + ), hydrogen (H 2 ) permeability (P H 2 ), and electrical resistivity (ρ e – ) were conducted using model thin films comprised of SiO 2 membranes deposited by atomic layer deposition (ALD). Although the H + conductivity of the SiO 2 membranes is 2–3 orders of magnitude lower than Nafion, the addition of phosphorus dopants (PO x ) improves H + conductivity such that the area specific membrane resistance of thin (<50 nm) PO x -doped SiO 2 membranes is more than an order of magnitude lower than Nafion-117. Importantly, the safe operation of such nanoscale membranes within a PEM electrolyzer is feasible thanks to the low H 2 permeability of dense SiO 2 -based membranes, which are predicted to limit H 2 crossover rates to acceptable levels for pressures up to ≈ 100 bar. As a proof-of-principle demonstration, a chip-scale water electrolyzer based on 100 nm thick PO x -SiO 2 membrane is shown to achieve a current density of 2 A cm –2 at a potential of 2.5 V. If this technology can be successfully scaled up, H + conducting oxide membranes offer an attractive PFAS-free alternative to Nafion for efficient and durable water electrolysis and fuel cell technologies.
Water reuse for sustainable microalgae cultivation: current knowledge and future directions
Microalgae hold great promise as environmentally sustainable sources of food, animal feed, and fuel. However, large amounts of water are used during microalgae cultivation and this negatively impacts economic viability and environmental sustainability. Reusing cultivation water can reduce the direct impacts of water usage and also reduce nutrient requirements and algal wastewater treatment. However, studies have shown that algae growth in reused water can be compromised, unaffected, or sometimes enhanced compared to controls. This review examines recent studies on water reuse to qualitatively understand these varied effects. Growth inhibitors and stimulators in reused water and their underlying mechanisms are discussed, as well as recent pre-treatment technologies and factors affecting the quality of reused water, such as microalgae taxa, culture conditions, and harvesting methods, are considered. A scheme is proposed for water reuse and harvesting methods based on the desired algal end products. Finally, taking these findings together, here we provide recommendations for further research directions as well as new insights into designing and integrating a cultivation strategy with a harvesting platform to reuse water for more efficient microalgae cultivation.
Volatile fatty acid extraction from fermentation broth using a hydrophobic ionic liquid and in situ enzymatic esterification
Efficient recovery of volatile fatty acids (VFAs) from fermentation broth is a challenge due to low VFA titers and thus limits the commercialization of VFA production using biological routes. Liquid–liquid extraction using hydrophobic ionic liquids (ILs) shows great promise for the extraction and esterification of hydrophilic VFAs. In this study, several ILs were evaluated to select a water-immiscible and efficient extraction solvent. The selected IL, trihexyltetradecyl phosphonium dibutylphosphate ([P 666,14 ][DBP]), gave a cumulative VFA extraction of around 842.8 mg per g IL. The predicted excess enthalpy (H E ) and logarithmic activity coefficients ln(γ) using the COSMO-RS model were validated with the experimentally obtained VFA recovery from fermentation broth. To understand the extraction mechanism of VFAs, quantum theory of atoms in molecules (QTAIM) and noncovalent interaction (NCI) were performed. The results suggest that long chain fatty acids exhibit strong van der Waals interaction with the DBP anion leading to higher VFA extraction. The enzymatic esterification of VFAs with ethanol in [P 666,14 ][DBP] was optimized using the Box–Behnken response surface design of experiment. Under the optimized conditions, up to 83.7% of hexanoic acid was converted to ethyl esters, while other shorter chain VFAs have lower conversion efficiency (38.3–63.2%).
Performance of Closed Loop Venturi Aspirated Aeration System: Experimental Study and Numerical Analysis with Discrete Bubble Model
In wastewater treatment plants, aeration plays a significant role as it encourages aerobic respiration of microbes, which are necessary to break down carbonaceous matter in the waste stream. This process can account for the majority of energy use in wastewater treatment plants. The aeration process is also necessary in odor control in lagoons and in the aquaculture industry. Generally, the aeration process is accomplished with compressors or blowers which can be of low efficiency due to ideal gas laws. This study introduces the idea of increasing aeration efficiency by looping water from a reservoir through a piping network which includes a venturi aspirator at its inlet. For this purpose, an experimental study has been conducted in a laboratory setup with a pump which pulls water from a tank, passes it through a Venturi aspirator and a helical piping network intended to increase bubble residence time, before depositing it back into the bulk fluid tank. This same process is modeled computationally, using a discrete bubble method (DBM), with good agreement with experiments. The overall purpose here is to determine the optimal configurations for standard aeration efficiency (SAE) and the standard oxygen transfer rate (SOTR). A parametric study has been implemented using the DBM based on different hydraulic and flow parameters. The model is also used to predict the SAE of a hypothetical aeration system. Results indicate that it is possible to achieve SAE values in the range of surface aerators or submersed jet aerators using the proposed aeration system with less complex components, thereby decreasing overall costs.
Observations and seismoacoustic simulations of earthquake-generated infrasound waves in non-epicentral regions
We analysed infrasound waves associated with the Gyeongju earthquake (ML 5.8) that occurred on 2016 September 12, in the southeastern Korean Peninsula. For infrasound wave detection, the Progressive Multichannel Correlation method was applied to the infrasound data set recorded at seven arrays operating in South Korea at epicentral distances ranging from 178 to 472 km. Based on the back-projection method constrained by array-dependent celerity and azimuth deviation models, the source regions were identified in both the epicentral and non-epicentral regions. Remarkably, the non-epicentral secondary sources of this earthquake were located in regions with shallow water depths: (i) the western coastal area in the Yellow Sea and (ii) the shallow ocean basin and bank in the East Sea. The location results obtained from the earthquake could be corroborated through its foreshock (ML 5.1), yielding location results consistent with those of the main shock. The generation of infrasound waves over shallow water depths was fortuitously validated by direct recordings of dominant single-frequency (~0.3 Hz) infrasound waves at close range via temporary sensors near the ocean basin and bank. We interpreted that low-frequency infrasound signals could be generated from interactions among the ocean floor, shallow seawater and atmosphere. We performed numerical simulations of seismoacoustic fields to predict ground motions on the seafloor and acoustic transmission efficiency between the water and air interface. The simulations quantified the energy transfer through different media and clarified our observational results. We found that because this solid Earth‒water‒atmosphere coupled air wave has a relatively low frequency (~0.3 Hz), it can survive propagation over long distances compared with high-frequency infrasound waves generated in inland and mountain regions. In this study, we extend our understanding of water‒atmosphere coupling and the monitoring framework for earthquake-associated non-epicentral infrasound waves, encompassing not only inland ground shaking but also shallow sea regions located far from the epicentre.
Addressing the Stability Gap in Photoelectrochemistry: Molybdenum Disulfide Protective Catalysts for Tandem III–V Unassisted Solar Water Splitting
While photoelectrochemical (PEC) solar-to-hydrogen efficiencies have greatly improved over the past few decades, advances in PEC durability have lagged behind. Corrosion of semiconductor photoabsorbers in the aqueous conditions needed for water splitting is a major challenge that limits device stability. In addition, a precious-metal catalyst is often required to efficiently promote water splitting. In this work, we demonstrate unassisted water splitting using a nonprecious metal molybdenum disulfide nanomaterial catalytic protection layer paired with a GaInAsP/GaAs tandem device. This device was able to achieve stable unassisted water splitting for nearly 12 h, while a sibling sample with a PtRu catalyst was only stable for 2 h, highlighting the advantage of the nonprecious metal catalyst. In situ optical imaging illustrates the progression of macroscopic degradation that causes device failure. Furthermore, this work compares unassisted water splitting devices across the field in terms of the efficiency and stability, illustrating the need for improved stability.
Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)
By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.
Applying colloidal silica suspensions injection and sequential gelation to block vertical water flow in well annulus: laboratory testing on rheology, gelation, and injection
We evaluated the application of silica suspension injection and sequential gelation to block vertical water flow in the annuli of long-screened wells. First, we studied the viscosity, rheological behavior, and gelation performance of colloidal silica suspensions in batch tests. Then, we tested the injection of silica suspensions and the water flow blocking efficiency of the later formed silica gel in column and bench-scale sandbox experiments. Micron-sized fumed powder silica suspensions and nanosized silica suspensions recovered from geothermal fluids were tested in this work. Fumed silica suspensions showed shear thinning, while nanosized silica suspensions exhibited Newtonian flow behavior. During the gelation process, the nanosized silica suspension changed from a Newtonian fluid to a shear thinning fluid while increasing its overall viscosity. At comparable concentrations, the nanosized silica suspensions have much lower viscosity than that of the fumed silica suspensions. Increases in the Na + concentration and silica particle concentration in these suspensions shortened the gelation time. Silica suspension gelation in sand columns completely blocked the water flow and sustained the injection pressure up to 50 psig (344.7 kPa). A silica suspension was successfully injected into the target zone in the annulus of a bench-scale sandbox mimicking long-screened wells in the field. The silica gel formed in the annulus effectively blocked chemical transport through the gelled zone. Our research reveals that a process using silica suspension injection and sequential gelation technology is promising for blocking the vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.
Theoretical model of dielectrophoretic water vapor condensation during multiphase flow of electrically charged water droplets in air
Water droplet growth in air, influenced by vapor diffusion and electrical charging, has significant implications for indoor air quality, cloud formation, and aerosol dynamics. Here, this study presents a comprehensive theoretical model that describes the growth dynamics of electrically charged water droplets under external electric fields, incorporating diffusion, electrostatic, and dielectrophoretic forces to enhance understanding and practical applications in air dehumidification and environmental control. A theoretical model was established to analyze the growth dynamics of the charged water droplets. The approach extended the thermodynamic framework of the Modified Kelvin-Thomson equation by integrating electrostatic and dielectrophoretic effects, enabling a comprehensive evaluation of vapor concentration near the surface of charged droplets. A sensitivity analysis was performed to assess the roles of droplet size, electric field intensity, surface charge, and vapor concentration on condensation rates. The study progressed beyond the classical diffusion-limited growth of neutral droplets, addressing the behavior of charged droplets in electrohydrodynamic environments. The model highlighted the significance of dielectrophoretic drift flux for dipolar vapor molecules, especially in micron-sized droplets ranging from 10 to 100 µm. Findings demonstrated that, for smaller droplets subjected to elevated electrical charge, average growth rates varied from 0.3 to 1.6 µm/s if the air relative humidity increased from 50 to 100 %. Analytical results are corroborated by numerical simulations, which exhibited strong concordance, thereby validating the proposed theoretical approach. This research introduced an innovative and scalable analytical methodology for electric field-enhanced droplet growth, offering valuable insights into the advancement of energy-efficient air dehumidification, water desalination, and atmospheric water harvesting technologies.
Standardization and best practices in single-cell testing for liquid alkaline water electrolysis
The increasing demand for efficient and sustainable hydrogen production has driven significant advancements in water electrolysis technologies. Among these, liquid alkaline water electrolysis (LAWE) stands out for its cost-effectiveness and scalability. This manuscript establishes best practices and standardized testing procedures for single-cell LAWE, focusing on the use of nickel foam as both anode and cathode substrates, while incorporating catalysts such as nickel-iron layered double hydroxide (NiFe-LDH) as the anode material and nickel-molybdenum on carbon (NiMo/C) as the cathode material. By providing detailed guidelines on material preparation, cell assembly, and performance evaluation, this work offers a comprehensive framework to improve reproducibility and ensure consistency. The results demonstrate that applying these best practices minimizes variability across different laboratories and experimental setups, laying the groundwork for more robust comparisons and accelerating progress in LAWE research.
High salinity seawater boiling point elevation: Experimental verification
Boiling point elevation (BPE) for high salinity solutions is a crucial parameter that significantly affects the overall thermal efficiency of desalination, water treatment, and many other industrial processing systems, especially when minimum or zero liquid discharge is a key requirement. This paper addresses the discrepancies among the empirical correlations reported in the literature that were commonly used to determine BPE for seawater solutions. An evaluation of the experimental data with low solution concentration reveals that the data cannot be extrapolated to determine the BPE at high concentration (X > 140 ppt or g/kg). Besides, disparities are established within different equations used to determine the BPE for high salinity seawater. As a result of the minimal availability of experimental data of BPE for X > 140 ppt and the need to eliminate the discrepancies, an experimental setup was built, which can produce reliable and repeatable BPE data for any solution concentration. Boiling points were obtained experimentally for seawater solutions with a wide range of salinity (X between 20 and 280 ppt) and brine solution temperature (t b between 20 and 80°C). The experimental results of boiling point elevations for seawater are further compared with the experimental data and analytical results reported in the literature. The newly obtained experimental results show that the minimum and maximum BPE values for the brine solutions tested are 0.175°C at t b = 80°C and X = 20 ppt, and 11.6°C at t b = 80°C and X = 280 ppt, respectively. Furthermore, the measured BPE data for seawater concentration over 80 ppt are fitted and presented using an appropriate fitting model. The new correlation can accurately predict the BPE for high salinity seawater brines and thus should be very helpful in the design of high-energy-efficient evaporation systems.
Reliable bi-functional nickel-phosphate /TiO2 integration enables stable n-GaAs photoanode for water oxidation under alkaline condition
Abstract Hydrogen is one of the most widely used essential chemicals worldwide, and it is also employed in the production of many other chemicals, especially carbon-free energy fuels produced via photoelectrochemical (PEC) water splitting. At present, gallium arsenide represents the most efficient photoanode material for PEC water oxidation, but it is known to either be anodically photocorroded or photopassivated by native metal oxides in the competitive reaction, limiting efficiency and stability. Here, we report chemically etched GaAs that is decorated with thin titanium dioxide (~30 nm-thick, crystalline) surface passivation layer along with nickel-phosphate (Ni-Pi) cocatalyst as a surface hole-sink layer. The integration of Ni-Pi bifunctional co-catalyst results in a highly efficient GaAs electrode with a ~ 100 mV cathodic shift of the onset potential. In this work, the electrode also has enhanced photostability under 110 h testing for PEC water oxidation at a steady current density J ph > 25 mA·cm −2 . The Et-GaAs/TiO 2 /Ni-Pi║Ni-Pi tandem configuration results in the best unassisted bias-free water splitting device with the highest J ph (~7.6 mA·cm −2 ) and a stable solar-to-hydrogen conversion efficiency of 9.5%.
Synthesis of rhenium coatings on 316 stainless steel and their electrochemical behavior towards water oxidation in saline environments
The production of electrolytic hydrogen or Green Hydrogen has attracted the attention of scientists as a potential enabler of sustainable energy production. The cleavage of the water molecule requires high energy, in order to produce hydrogen and oxygen through their corresponding half reactions, the hydrogen evolution and oxygen evolution reactions. Further, this latter reaction has been studied in more detail, since its slow kinetics make the water electrolysis less efficient, and, for instance, delay the formation of hydrogen in the counter compartment of the electrolytic cell. In this work, a study of the oxygen evolution reaction is presented. For this, a series of rhenium catalysts deposited onto stainless steel 316 are studied with the aim of analyzing the effect of the pure metal (Re) and the metal with heteroatoms (Re-C, Re-B, and Re-O). As one of the problems worldwide is the scarcity of freshwater, the study focuses on the performance of this series of catalysts in highly saline environments, representative of seawater. The synthesis and electrochemical performance is shown, giving high expectations that these electrocatalysts could be potential electrocatalysts in marine environments.
Tailored (La 0.2 Pr 0.2 Nd 0.2 Tb 0.2 Dy 0.2 ) 2 Ce 2 O 7 as a Highly Active and Stable Nanocatalyst for the Oxygen Evolution Reaction
Abstract Designing highly active and robust catalysts for the oxygen evolution reaction is key to improving the overall efficiency of the water splitting reaction. It has been previously demonstrated that evaporation induced self‐assembly (EISA) can be used to synthesize highly porous and high surface area cerate‐based fluorite nanocatalysts, and that substitution of Ce with 50% rare earth (RE) cations significantly improves electrocatalyst activity. Herein, the defect structure of the best performing nanocatalyst in the series are further explored, Nd 2 Ce 2 O 7 , with a combination of neutron diffraction and neutron pair distribution function analysis. It is found that Nd 3 + cation substitution for Ce in the CeO 2 fluorite lattice introduces higher levels of oxygen Frenkel defects and induces a partially reduced RE 1.5 Ce 1.5 O 5 +x phase with oxygen vacancy ordering. Significantly, it is demonstrated that the concentration of oxygen Frenkel defects and improved electrocatalytic activity can be further enhanced by increasing the compositional complexity (number of RE cations involved) in the substitution. The resulting novel compositionally‐complex fluorite– (La 0.2 Pr 0.2 Nd 0.2 Tb 0.2 Dy 0.2 ) 2 Ce 2 O 7 is shown to display a low OER overpotential of 210 mV at a current density of 10 mAcm −2 in 1M KOH, and excellent cycling stability. It is suggested that increasing the compositional complexity of fluorite nanocatalysts expands the ability to tailor catalyst design.
Data Center Facility Monitoring with Physics Aware Approach
U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.