A Green, Fire–Retarding Ether Solvent for Sustainable High–Voltage Li–Ion Batteries at Standard Salt Concentration

Lithium-ion batteries (LIBs) are increasingly encouraged to enhance their environmental friendliness and safety while maintaining optimal energy density and cost-effectiveness. Although various electrolytes using greener and safer glyme solvents have been reported, the low charge voltage (usually lower than 4.0 V vs Li/Li + ) restricts the energy density of LIBs. Herein, tetraglyme, a less-toxic, non-volatile, and non-flammable ether solvent, is exploited to build safer and greener LIBs. It is demonstrated that ether electrolytes, at a standard salt concentration (1 m), can be reversibly cycled to 4.5 V vs Li/Li + . Anchored with Boron-rich cathode-electrolyte interphase (CEI) and mitigated current collector corrosion, the LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathode delivers competitive cyclability versus commercial carbonate electrolytes when charged to 4.5 V. Synchrotron spectroscopic and imaging analyses show that the tetraglyme electrolyte can sufficiently suppress the overcharge behavior associated with the high-voltage electrolyte decomposition, which is advantageous over previously reported glyme electrolytes. The new electrolyte also enables minimal transition metal dissolution and deposition. NMC811||hard carbon full cell delivers excellent cycling stability at C/3 with a high average Coulombic efficiency of 99.77%. In conclusion, this work reports an oxidation-resilient tetraglyme electrolyte with record-high 4.5 V stability and enlightens further applications of glyme solvents for sustainable LIBs by designing Boron-rich interphases.

36 MATERIALS SCIENCE↗

Mechanistic Elucidation of Electronically Conductive PEDOT:PSS Tailored Binder for a Potassium‐Ion Battery Graphite Anode: Electrochemical, Mechanical, and Thermal Safety Aspects

Potassium-ion batteries (KIBs) are considered more appropriate for grid-scale storage than lithium-ion batteries (LIBs) due to similar operating chemistry, abundant precursors, and compatibility with low-cost graphite anodes. However, a larger ion reduces rate capabilities and exacerbates capacity fading from volumetric expansion. In this report, conductive polymer, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS), is substituted for standard insulating polyvinylidene fluoride (PVDF). Half-cells using carbon black (CB) in continuously conductive PEDOT:PSS/CB binder outperforms PVDF/CB by mitigating electrically isolated “dead” graphite, improving 100 cycle capacity retention at C/10 from 63 to 80%. Enhanced electrical contact with PEDOT:PSS/CB also reduces ion impedance and improves rate capabilities. Without CB however, PEDOT:PSS binder performs poorly in electrochemical studies despite promising ex situ electronic conductivity. This discrepancy is mechanistically elucidated through identification of redox activity between PEDOT:PSS and K + which results in high impedances in the anode operating voltage window. Additionally, the impact of conducting binder on mechanical properties and thermal safety of the anode is investigated. Brittleness and poor wettability of PEDOT:PSS are identified as issues, but greater stability against reactive KC 8 reduces overall heat generation. Binder substitution offers a promising means of mitigating issues with current KIB anodes regardless of active material, and the work herein addresses issues towards further improvement.

electrochemical impedance spectroscopy↗

Exploring the Basic Physical Mechanisms of Cathode- and Anode-Initiated High-Voltage Surface Flashover

Surface flashover in vacuum imposes a substantial physical limit on modern, large-scale pulsed power. One of the ramifications is a minimum size requirement for new machines, which in itself becomes a hard barrier to the modernization and improvement of existing infrastructure. Pulsed power topologies require the physical mechanisms of both anode- and cathode-initiated flashover to be considered. Originally, the geometrical implications of field emission at the cathode triple junction (CTJ) motivated the usage of configurations that avoid electrons impinging on the insulating material. This will largely suppress the cathode-initiated flashover, which is best described by the secondary electron avalanche mechanism, gas desorption, and final breakdown in the desorbed gas. It depends on the cascade growth of a conducting plasma along the length of the insulator from the cathode. Mitigating the cathode-initiated flashover typically comes at the cost of a significant field enhancement at the anode triple junction (ATJ). In a typical implementation, the anode field may be three times higher than the cathode field for a given voltage, making the corresponding anode-initiated flashover much more common than otherwise. In the case of pulsed, anode-initiated flashover, experimental evidence suggests that charge is directly extracted from the insulator resulting in the insulator taking on a net positive charge advancing the anode potential. Furthermore, along with accompanying gas desorption from the surface, the potential will then propagate from the anode toward the cathode until the effective length of the gap is sufficiently reduced to support flashover. The underlying physical mechanisms of cathode- and anode-directed flashover are discussed in light of previously gathered experimental data and recent experiments with pulsed, high-gradient, anode-initiated flashover.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the Langmuir probe system on the Mega Ampere Spherical Tokamak (MAST) Upgrade

A detailed description of the Langmuir probe system on Mega Ampere Spherical Tokamak Upgrade is presented. The system features 850 tile-embedded probes and 40 bespoke electronic modules that each have the capability to drive and acquire data from up to 16 probes in a time-multiplexed manner. The system provides spatiotemporal-resolved measurements (1 cm and ~1 ms, respectively) in the divertor region of ion saturation current, electron temperature, and floating potential. The standard interpretation of current-voltage (IV) characteristics is to apply a four-parameter fit, based on unmagnetized probe theory, which includes a linear model for the ion saturation region. In conclusion, to mitigate the effect of the magnetic field, analysis is restricted to the region of the IV characteristic, which is sensitive to only the tail of the electron energy distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant: Preprint

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and Power System Stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It mitigates the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Control of hybrid boosting in highly diluted internal combustion engines

A novel hybrid system enabling both flexible supercharging and limited torque assist is studied to mitigate transient response challenges of a turbocharged spark ignition engine equipped with low pressure exhaust gas recirculation. The hybrid system, called a power split supercharger (SC), is configured with a planetary gear set that splits the supercharging power between a small low-voltage electric motor and the engine crankshaft. The air path controller relies on the coordination of four actuators on the engine side and three low-level actuators on the hybrid boosting device. A decentralized control scheme is used in this work, in which the master–slave structure of the boost pressure controller decreases the turbo-lag associated with exhaust gas recirculation, while minimizing the SC operation for fuel economy. A vector reference governor is used to prevent compressor surge during engine tip-outs. In addition, the desired intake manifold pressure is modified to provide time for evacuating the exhaust gas recirculation and avoiding misfires when transitioning to low load, while the hybrid capability of the power split SC is used to recuperate the unwanted generated power. All controllers are validated on both a mean value engine model and a high-fidelity engine model. Practical challenges of implementing the vector reference governor to the highly nonlinear engine air path with pressure pulsations originating from the engine reciprocation are discussed and some solutions are proposed.

Engineering↗

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING↗

Mitigation and Diagnosis of Pin-Hole Formation in Polymer Electrolyte Membrane Fuel Cells

In this work, we implement a calendering technique to flatten stray fibers within the gas diffusion media, thereby mitigating pin-hole formation in the hot-pressed MEAs. We have investigated the influence of calendering on the long-term durability for several types of gas diffusion electrodes (GDEs) using a combined chemical and mechanical accelerated stress test (AST). The calendered MEAs demonstrate an average AST lifetime improvement of 77% relative to the as-fabricated MEAs.

AMR↗

Pricing Strategy of Electric Vehicle Aggregators Based on Locational Marginal Price to Minimize Photovoltaic (PV) Curtailment

The global climate crisis demands urgent action to mitigate global warming. Using renewable energy sources, such as solar and wind power, for electricity generation is crucial. This shift from centralized to distributed power systems, however, brings challenges, including voltage fluctuations and renewable energy curtailment. The rapid growth of the electric vehicle (EV) industry adds complexity, increasing overall electricity demand and straining the power supply during peak charging times. This paper proposes a scheduling strategy for EV aggregators to reduce renewable energy curtailment and stabilize grid operation by strategically scheduling EV charging. Using Multi -Agent Transport Simulation (MATSim), a traffic simulation tool, EV driving data in Denver, Colorado, USA, were modeled. The EV aggregator adjusts charging fees based on locational marginal prices, encouraging EVs to charge at different stations according to pricing. Simulations on an IEEE 33-bus system with distributed energy resources and EV charging stations validate the proposed algorithm, demonstrating its effectiveness in reducing curtailment by 12.55% and stabilizing grid operation.

33 ADVANCED PROPULSION SYSTEMS↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Towards Scalable 3D Integration of 2T-nC FeRAM with Hundreds of Layer Stacking

In this article, we study the limits of the number of capacitors and read history dependence in a 2T-nC ferroelectric random-access memory (FeRAM) cell, paving the way for its high-density integration toward hundreds of stacked layers. Through a comprehensive experimental and simulation study on the scaling behavior of the 2T-nC FeRAM architecture, we demonstrate: (i) successful fabrication of 2T-64C cells with robust memory operation and clearly distinguishable ‘0’ and ‘1’ states, even in 64- capacitor configurations; (ii) that the parasitic capacitance of the floating node originates predominantly from the linear component of the ferroelectric capacitor, and its impact on n-scaling—due to degraded sense margin—can be mitigated by floating unselected capacitors with enough TΩ isolation; (iii) that sharing write and read transistors among n capacitors introduces a read history dependence issue due to fluctuating floating node voltage (VFN); and (iv) that a proposed FN discharge scheme can effectively eliminate read-sequence dependence, at the cost of reduced read endurance.

36 MATERIALS SCIENCE↗

Performance and Implementation Requirements for Residential EV Smart Charge Management Strategies

As the electrification of transportation expands, electric vehicle (EV) charging as residential loads will continue to grow. Residential EV charging has the potential to increase feeder peak loads and decrease voltage quality. As a result of this growing energy demand driven by EV, utilities may employ the use of smart charge management (SCM) controls to modify charging load profiles and mitigate these grid impacts. It is important that utilities understand both the potential benefits-as well as possible implementation challenges-before considering this technology as a solution to managing growing EV loads. In order for an SCM strategy to be an effective solution, the potential benefits must outweigh the implementation challenges. This study establishes and tests a novel framework to assess the implementation requirements of different SCM controls. It identifies a range of requirements specific to various SCM controls and implementation approaches to compare the relative challenges associated with the deployment of each. When paired with analysis on the effectiveness of the ability of each control to mitigate grid impacts from EV charging, this assessment is critical in comparing the value potential of different SCM controls.

ADVANCED PROPULSION SYSTEMS↗

Hardware Demonstration of Weak Grid Oscillations in Grid-Following Converters

The increasing penetration of inverter-based resources (IBRs) introduces some unexpected dynamic issues, including low-frequency oscillations. In this paper, a laboratory-scale grid-following voltage-source converter (VSC) system is implemented to demonstrate weak grid oscillations. Grid-following control is applied in VSC to provide active power, reactive power or ac voltage control. The test bed is also replicated in electromagnetic transient (EMT) simulation environment (MAT-LAB/SimPowerSystems) for benchmark purpose. Case studies are carried out to demonstrate low-frequency oscillations under real power/ac voltage or real power/reactive power control. The excellent agreement between the simulation and experimental results ensures that the two test beds are exchangeable and can be used for testing oscillation mitigation strategies in future research.

Bao, Li↗

Carbonate Management to Enable Energy- and Carbon-Efficient CO 2 Electrolysis (Final Technical Report)

The rapid growth and plummeting cost of solar energy have spurred growing interest in using CO 2 electrolysis to produce chemicals and fuels as an alternative to conventional petrochemical processes. High-temperature (>800 °C) solid oxide electrolyzers that convert CO 2 into CO and O 2 have recently become commercially available. Low-temperature electrolysis cells offer the prospect of more convenient and flexible operation, which is critical for utilizing intermittent solar energy, and provide access to more valuable C 2+ products such as ethylene, ethanol, and propanol. Over the past 10 years, research in this area has yielded substantial progress in both fundamental understanding of the requisite electrocatalytic reactions and design of prototype devices. Leveraging insights from fuel cells and membrane water electrolyzers, researchers have developed electrolysis cells with gas diffusion electrodes (GDE) that have demonstrated high CO 2 electrolysis current densities (>100 mA cm –2 ) as well as promising selectivity and stability. Despite these advances, the energy efficiency (electrical energy-to-product) and carbon efficiency (CO 2 -to-product) of low-temperature CO 2 electrolysis remain far too low for large-scale deployment. A preponderance of evidence indicates that the principal source of efficiency losses is the rapid and thermodynamically favorable reaction of CO 2 with hydroxide (OH – ) to form carbonate (CO 3 2– ). Carbonate formation imposes steady-state electrolysis conditions that result in large voltage and CO 2 losses for all known (photo)electrochemical CO 2 cells. While much current research remains focused on CO 2 reduction catalyst design, this largely overlooked CO 3 2– problem presents a fundamental scientific barrier to creating a viable electrochemical option for converting solar energy into chemicals and fuels. The project pursues an integrated, multi-PI research effort that establishes a fundamental science of CO 3 2– management. PI Kanan and Co-PI Mani’s contribution to the project is to evaluate strategies to mitigate the CO 3 2– problem by changing the properties of the electrolyte and the environment in which CO 2 reduction catalysis takes place. Experimental studies showed that electrolytes composed of a high concentration of both CO 3 2– and HCO 3 – , which serve as moderately alkaline buffers, improved the cell voltage by compared to all-HCO 3 – electrolytes, but these buffered systems still show substantial CO 2 uptake that reduces pH over time. Computational studies developed a homogenized model of a CO 2 reduction catalyst layer that permits a low-cost exploration of the high-dimensional parameter space associated with catalyst layers on gas diffusion electrodes. The model was validated by accurately reproducing experimental data for the related but simpler reaction of CO reduction and then used to probe the effects of catalyst layer architecture on CO 2 reduction. Minimizing the size of catalyst and hydrophobic domains in the catalyst layer is predicted to mitigate CO 3 2– formation and thereby enable prolonged operation at elevated pH. In support of the CO 2 electrolysis studies, a new method for rapidly prototyping electrochemical cells was developed and validated. The method uses a combination of 3D printing and electroless plating to generate conductive cell components for evaluating new cell designs. The carbonate problem encompasses mass transport processes and acid-base reactions that are relevant to many other electrochemical systems. Investigation of strategies to address the carbonate problem led to an additional line of inquiry into the physicochemical phenomena that determine the efficiency of electrochemical acid-base production, which has numerous applications in the broader field of carbon management. New strategies for using the supporting electrolyte to inhibit H + /OH – recombination in electrochemical acid-base production were evaluated, leading to the development of a novel acid-base producing system that eliminates the need for ion exchange membranes and exhibits promising efficiency and current densities for scalable applications.

25 ENERGY STORAGE↗

A Hybrid Transmitter With Voltage-Mode SST Preemphasis and Current-Mode Transmitter Equalization Capable of Operating at 77 K in DUNE

The Deep Underground Neutrino Experiment (DUNE) requires that the front-end transmitters operate at cryogenic temperature and drive 25–35 m long twin-axial (twinax) cables. Here, to compensate the frequency-dependent channel loss over the long cables and alleviate the de-emphasizing of the low-frequency signal magnitude, a hybrid of a current-mode (CM) transmitter equalization (TXEQ) and a voltage-mode (VM) preemphasis is proposed. The TXEQ employs a finite-impulse response (FIR) filter to boost the high-frequency components while de-emphasizing the low-frequency signal magnitude, thereby flattening the overall channel frequency response and reducing the intersymbol interference (ISI). The VM preemphasis is proposed to further mitigate ISI by boosting the high-frequency portion without degrading the signal magnitude, allowing for high signal swing. The main driver utilizes VM source-series-terminated (SST) output stages, which offers higher signal swing and better power efficiency than the conventional CM logic (CML) drivers. To ensure the lifetime and reliability at cryogenic temperature, the transmitter is implemented in a 65-nm CMOS process operating at 1.1 V of supply voltage and employing transistors with larger than minimum lengths. Silicon measurement results at 77 K have validated the proposed approaches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-State Fault Current Limiter Development: Design and Testing Update of a 15kV SSCL Power Stack

The Solid-State Fault Current Limiter (SSCL) is a promising technology that can be applied to utility power delivery systems to address the problem of increasing fault currents associated with load growth. As demand continues to grow, more power is added to utility system either by increasing generator capacity or by adding distributed generators, resulting in higher available fault currents, often beyond the capabilities of the present infrastructure. The SSCL is power-electronics based equipment designed to work with the present utility system to address this problem. The SSCL monitors the line current and dynamically inserts additional impedance into the line in the event of a fault being detected. The SSCL is based on a modular design and can be configured for 5kV through 69kV systems at nominal current ratings of 1000A to 4000A. Results and Findings This report provides the final test results on the development of 15kV class SSCL single phase power stack. The scope of work included the design of the modular standard building block sub-assemblies, the design and manufacture of the power stack and the testing of the power stack for the key functional tests of continuous current capability and fault current limiting action. Challenges and Objectives Solid-State Current Limiter technology impacts a wide spectrum of utility engineering and operating personnel. It addresses the problems associated with load growth both at Transmission and Distribution class networks. The design concept is pioneering in terms of developing the most efficient and compact power electronics equipment for utility use. The initial test results of the standard building blocks are promising. The independent laboratory tests of the power stack are promising. However the complete 3 phase system needs rigorous testing for performance and reliability. Applications, Values, and Use The SSCL is an intelligent power-electronics device which is modular in design and can provide current limiting or current interrupting capabilities. It can be applied to variety of applications from distribution class to transmission class power delivery grids and networks. It can also be applied to single major commercial and industrial loads and distributed generator supplies. The active switching of devices can be further utilized for protection of substation transformers. The stress on the system can be reduced substantially improving the life of the power system. It minimizes the voltage sag by speedy elimination of heavy fault currents and promises to be an important element of the utility power system. DOE Perspective This development effort is now focused on a 15kV system. This project will help mitigate the challenges of increasing available fault current. DOE has made a major contribution in providing a cost effective SSCL designed to integrate seamlessly into the Transmission and Distribution networks of today and the future. Approach SSCL development program for a 69kV SSCL was initiated which included the use of the Super GTO advanced semiconductor device which won the 2007 R&D100 Award. In the beginning, steps were identified to accomplish the economically viable design of a 69kV class Solid State Current Limiter that is extremely reliable, cost effective, and compact enough to be applied in urban transmission. The prime thrust in design and development was to encompass the 1000A and the 3000A ratings and provide a modular design to cover the wide range of applications. The focus of the project was then shifted to a 15kV class SSCL. The specifications for the 15kV power stack are reviewed. The design changes integrated into the 15kV power stack are discussed. In this Technical Update the complete project is summarized followed by a detailed test report. The power stack independent high voltage laboratory test requirements and results are presented. Keywords Solid State Current Limiter, SSCL, Fault Current Limiter, Fault Current Controller, Power electronics controller, Intelligent power-electronics Device, IED

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structure/Interface Coupling Effect for High-Voltage LiCoO 2 Cathodes

LiCoO 2 (LCO) is widely applied in today's rechargeable battery markets for consumer electronic devices. However, LCO operations at high voltage are hindered by accelerated structure degradation and electrode/electrolyte interface decomposition. To overcome these challenges, co-modified LCO (defined as CB-Mg-LCO) that couples pillar structures with interface shielding are successfully synthesized for achieving high-energy-density and structurally stable cathode material. Benefitting from the "Mg-pillar" effect, irreversible phase transitions are significantly suppressed and highly reversible Li + shuttling is enabled. Interestingly, bonding effects between the interfacial lattice oxygen of CB-Mg-LCO and amorphous Co x B y coating layer are found to elevate the formation energy of oxygen vacancies, thereby considerably mitigating lattice oxygen loss and inhibiting irreversible phase transformation. Meanwhile, interface shielding effects are also beneficial for mitigating parasitic electrode/electrolyte reactions, subsequent Co dissolution, and ultimately enable a robust electrode/electrolyte interface. As a result, the as-designed CB-Mg-LCO cathode achieves a high capacity and excellent cycle stability with 94.6% capacity retention at an extremely high cut-off voltage of 4.6 V. We report these findings provide new insights for cathode material modification methods, which serves to guide future cathode material design.