Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “version control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Primary Tumor Necrosis Predicts Distant Control in Locally Advanced Soft-Tissue Sarcomas After Preoperative Concurrent Chemoradiotherapy

Purpose: Various neoadjuvant approaches have been evaluated for the treatment of locally advanced soft-tissue sarcomas. This retrospective study describes a uniquely modified version of the Eilber regimen developed at the University of Chicago. Methods and Materials: We treated 34 patients (28 Stage III and 6 Stage IV) with locally advanced soft-tissue sarcomas of an extremity between 1995 and 2008. All patients received preoperative therapy including ifosfamide (2.5 g/m2 per day for 5 days) with concurrent radiation (28 Gy in 3.5-Gy daily fractions), sandwiched between various chemotherapy regimens. Postoperatively, 47% received further adjuvant chemotherapy. Results: Most tumors (94%) were Grade 3, and all were T2b, with a median size of 10.3 cm. Wide excision was performed in 29 patients (85%), and 5 required amputation. Of the resected tumor specimens, 50% exhibited high (>=90%) treatment-induced necrosis and 11.8% had a complete pathologic response. Surgical margins were negative in all patients. The 5-year survival rate was 42.3% for all patients and 45.2% for Stage III patients. For limb-preservation patients, the 5-year local control rate was 89.0% and reoperation was required for wound complications in 17.2%. The 5-year freedom-from-distant metastasis rate was 53.4% (Stage IV patients excluded), and freedom from distant metastasis was superior if treatment-induced tumor necrosis was 90% or greater (84.6% vs. 19.9%, p = 0.02). Conclusions: This well-tolerated concurrent chemoradiotherapy approach yields excellent rates of limb preservation and local control. The resulting treatment-induced necrosis rates are predictive of subsequent metastatic risk, and this information may provide an opportunity to guide postoperative systemic therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

VOLTTRON Version 3.x

VOLTTRON™ is an agent execution platform providing services to its agents that allow them to easily communicate with physical devices and other resources. VOLTTRON™ delivers an innovative distributed control and sensing software platform that supports modern control strategies, including agent-based and transaction-based controls. It enables mobile and stationary software agents to perform information gathering, processing, and control actions. VOLTTRON™ can independently manage a wide range of applications, such as HVAC systems, electric vehicles, distributed energy or entire building loads, leading to improved operational efficiency.

Source record↗

Sensitivity of summer ensembles of fledgling superparameterized U.S. mesoscale convective systems to cloud resolving model microphysics and grid configuration

The sensitivities of simulated mesoscale convective systems (MCSs) in the central U.S. to microphysics and grid configuration are evaluated here in a global climate model (GCM) that also permits global-scale feedbacks and variability. Since conventional GCMs do not simulate MCSs, studying their sensitivities in a global framework useful for climate change simulations has not previously been possible. To date, MCS sensitivity experiments have relied on controlled cloud resolving model (CRM) studies with limited domains, which avoid internal variability and neglect feedbacks between local convection and larger-scale dynamics. However, recent work with superparameterized (SP) GCMs has shown that eastward propagating MCS-like events are captured when embedded CRMs replace convective parameterizations. This study uses a SP version of the Community Atmosphere Model version 5 (SP-CAM5) to evaluate MCS sensitivities, applying an objective empirical orthogonal function algorithm to identify MCS-like events, and harmonizing composite storms to account for seasonal and spatial heterogeneity. A five-summer control simulation is used to assess the magnitude of internal and interannual variability relative to 10 sensitivity experiments with varied CRM parameters, including ice fall speed, one-moment and two-moment microphysics, and grid spacing. MCS sensitivities were found to be subtle with respect to internal variability, and indicate that ensembles of over 100 storms may be necessary to detect robust differences in SP-GCMs. Furthermore, these results emphasize that the properties of MCSs can vary widely across individual events, and improving their representation in global simulations with significant internal variability may require comparison to long (multidecadal) time series of observed events rather than single season field campaigns.

54 ENVIRONMENTAL SCIENCES↗

Supercapacitor to Provide Ancillary Services: Preprint

Supercapacitor technology has reached a level of maturity as a viable energy storage option available to support a modern electric power system grid; however, its application is still limited because of its energy capacity and the cost of the commercial product. In this paper, we demonstrate transient models of supercapacitor energy storage plants operating in coordination with run-of-the-river (ROR), doubly-fed induction generator hydropower plants (HPP) using a system control concept and architecture developed. A detailed transient model of a supercapacitor energy storage device is coupled with the grid via a three-phase inverter/rectifier and bidirectional DC-DC converter. In addition, we use a version of a 14-bus IEEE test case that includes the models of the supercapacitor energy storage device, ROR HPPs, and synchronous condensers that use the rotating synchronous generators of retired coal-powered plants. The purpose of the synchronous condensers is to enhance the system stability by providing voltage and reactive power control, provide power system oscillations damping, and maintain system inertia at secure levels. The control layer provides coordinated, decentralized operation of distributed ROR HPPs and energy storage as aggregate support to power system operations.

25 ENERGY STORAGE↗

A-B Transition in Superfluid $^3$He and Cosmological Phase Transitions

First-order phase transitions in the very early universe are a prediction of many extensions of the Standard Model of particle physics and could provide the departure from equilibrium needed for a dynamical explanation of the baryon asymmetry of the Universe. They could also produce gravitational waves of a frequency observable by future space-based detectors such as the Laser Interferometer Space Antenna. All calculations of the gravitational wave power spectrum rely on a relativistic version of the classical nucleation theory of Cahn-Hilliard and Langer, due to Coleman and Linde. The high purity and precise control of pressure and temperature achievable in the laboratory made the first-order A to B transition of superfluid $^3$He ideal for test of classical nucleation theory. As Leggett and others have noted, the theory fails dramatically. The lifetime of the metastable A phase is measurable, typically of order minutes to hours, far faster than classical nucleation theory predicts. If the nucleation of B phase from the supercooled A phase is due to a new, rapid intrinsic mechanism that would have implications for first-order cosmological phase transitions as well as predictions for gravitational wave production in the early universe. Here we discuss studies of the A-B phase transition dynamics in $^3$He, both experimental and theoretical, and show how the computational technology for cosmological phase transition can be used to simulate the dynamics of the A-B transition, support the experimental investigations of the A-B transition in the QUEST-DMC collaboration with the goal of identifying and quantifying the mechanism(s) responsible for nucleation of stable phases in ultra-pure metastable quantum phases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Outcomes of Sinonasal Cancer Treated With Proton Therapy

Purpose: To report disease outcomes after proton therapy (PT) for sinonasal cancer. Methods and Materials: Eighty-four adult patients without metastases received primary (13%) or adjuvant (87%) PT for sinonasal cancers (excluding melanoma, sarcoma, and lymphoma). Common histologies were olfactory neuroblastoma (23%), squamous cell carcinoma (22%), and adenoid cystic carcinoma (17%). Advanced stage (T3 in 25% and T4 in 69%) and high-grade histology (51%) were common. Surgical procedures included endoscopic resection alone (45%), endoscopic resection with craniotomy (12%), or open resection (30%). Gross residual disease was present in 26% of patients. Most patients received hyperfractionated PT (1.2 Gy [relative biological effectiveness (RBE)] twice daily, 99%) and chemotherapy (75%). The median PT dose was 73.8 Gy (RBE), with 85% of patients receiving more than 70 Gy (RBE). Prognostic factors were analyzed using Kaplan-Meier analysis and proportional hazards regression for multiple regression. Dosimetric parameters were evaluated using logistic regression. Serious, late grade 3 or higher toxicity was reported using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 4. The median follow-up was 2.4 years for all patients and 2.7 years among living patients. Results: The local control (LC), neck control, freedom from distant metastasis, disease-free survival, cause-specific survival, and overall survival rates were 83%, 94%, 73%, 63%, 70%, and 68%, respectively, at 3 years. Gross total resection and PT resulted in a 90% 3-year LC rate. The 3-year LC rate was 61% for primary radiation therapy and 59% for patients with gross disease. Gross disease was the only significant factor for LC on multivariate analysis, whereas grade and continuous LC were prognostic for overall survival. Six of 12 local recurrences were marginal. Dural dissemination represented 26% of distant recurrences. Late toxicity occurred in 24% of patients (with grade 3 or higher unilateral vision loss in 2%). Conclusions: Dose-intensified, hyperfractionated PT with or without concurrent chemotherapy results in excellent LC after gross total resection, and results in patients with gross disease are encouraging. Patients with high-grade histology are at greater risk of death from distant dissemination. Continuous LC is a major determinant of survival justifying aggressive local therapy in nearly all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Zero Energy Ready Home Multifamily Case Study Analysis

Two multifamily buildings planned in Climate Zone 4 were analyzed to determine the cost, energy and performance implications of redesigning them to comply with Zero Energy Ready Home, a recognition program of the U.S. Department of Energy. Energy modeling was conducted on one representative apartment in each building using BEopt. Construction costs were obtained from the developer and subcontractors to determine savings and cost increases over ENERGY STAR. It was found that seven items would be necessary to change to comply with ZERH criteria when starting from the original design which was compliant with ENERGY STAR version 3.0. Design changes were made to the exterior walls, domestic water heating system, duct protection, duct design, garage ventilation, and pest control to comply with ZERH requirements. Energy impacts of upgrading from the original design to ZERH resulted in 2 to 8% reduction in modeled source energy consumption, or 1.7 to 10.4 MMBtu per year, although the original design was already about 8% better than a design configured to minimum ENERGY STAR criteria. According to the BEopt analysis, annualized energy related costs of the ZERH design were slightly higher for the apartment and slightly lower for the townhome when compared to the original design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TA-3-38 Metals Fab SWPPP Rev 2 Jan 2017-Final

The TA-3-38 MFS is part of LANL’s Utilities and Infrastructures (UI) Facilities Operations Directorate (FOD) with day-to-day management provided by the Logistics Division Central Shops (LOG-CS); which has established a Stormwater Pollution Prevention Team (PPT) whose members are responsible for assisting the facility manager in developing and revising the facility’s SWPPP as well as maintaining control measures and taking corrective actions when required. All PPT members will have access to either a hard copy or an electronic version of this SWPPP. A list of PPT members along with duties and contact information is provided in Appendix A of this SWPPP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TA-3-38 Carpenter's Shop SWPPP Rev 2 Jan 2017-Final

The TA-3-38 CS is part of LANL’s Utilities and Infrastructure (UI) Facilities Operations Directorate (FOD) with day-to-day management provided by the Logistics Division Central Shops (LOG-CS); which has established a Stormwater Pollution Prevention Team (PPT) whose members are responsible for assisting the facility manager in developing and revising the facility’s SWPPP as well as maintaining control measures and taking corrective actions when required. All PPT members will have access to either a hard copy or an electronic version of this SWPPP. A list of PPT members along with duties and contact information is provided in Appendix A of this SWPPP

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stormwater Pollution Prevention Plan for the TA-03-38 Carpenter's Shop, Los Alamos National Laboratory, Revision 3 Final, January 2018

The TA-03-38 CS is part of LANL’s Utilities and Infrastructure (UI) Facilities Operations Directorate (FOD) with day-to-day management provided by the Logistics Division Central Shops (LOG-CS); which has established a Stormwater Pollution Prevention Team (PPT) whose members are responsible for assisting the facility manager in developing and revising the facility’s SWPPP as well as maintaining control measures and taking corrective actions when required. All PPT members will have access to either a hard copy or an electronic version of this SWPPP. A list of PPT members along with duties and contact information is provided in Appendix A of this SWPPP.

54 ENVIRONMENTAL SCIENCES↗

Stormwater Pollution Prevention Plan for the TA-03-38 Metals Fabrication Shop, Los Alamos National Laboratory, Revision 3 Final, January 2018

The TA-03-38 MFS is part of LANL’s Utilities and Infrastructures (UI) Facilities Operations Directorate (FOD) with day-to-day management provided by the Logistics Division Central Shops (LOG-CS); which has established a Stormwater Pollution Prevention Team (PPT) whose members are responsible for assisting the facility manager in developing and revising the facility’s SWPPP as well as maintaining control measures and taking corrective actions when required. All PPT members will have access to either a hard copy or an electronic version of this SWPPP. A list of PPT members along with duties and contact information is provided in Appendix A of this SWPPP.

54 ENVIRONMENTAL SCIENCES↗

Stormwater Pollution Prevention Plan for the TA-03-22 Power and Steam Plant, Los Alamos National Laboratory, Revision 3 Final, January 2018

The TA-03-22 Power and Steam Plant (PSP) is part of LANL’s Utilities and Institutional (UI) Facilities Operations Directorate (FOD) with day-to-day management provided by UI facility and operations personnel; which has established a Stormwater Pollution Prevention Team (PPT) whose members are responsible for assisting the facility manager in developing and revising the facility’s SWPPP as well as maintaining control measures and taking corrective actions when required. All PPT members will have access to either a hard copy or an electronic version of this SWPPP.

54 ENVIRONMENTAL SCIENCES↗

Stormwater Pollution Prevention Plan for the TA-60-02 Salvage/Warehouse, Los Alamos National Laboratory, Revision 3 Final, January 2018

The TA-60-02 Salvage/Warehouse is part of LANL’s Utilities and Infrastructures (UI) Facilities Operations Directorate (FOD) with day-to-day management provided by the Logistics Division Central Shops (LOG -CS); which has established a Stormwater Pollution Prevention Team (PPT) whose members are responsible for assisting the facility manager in developing and revising the facility’s SWPPP as well as maintaining control measures and taking corrective actions when required. All PPT members will have access to either a hard copy or an electronic version of this SWPPP. A list of PPT members along with duties and contact information is provided in Appendix A of this SWPPP.

54 ENVIRONMENTAL SCIENCES↗

SFWST Disposal Research R&D 5-Year Plan (FY2023 Update)

This FY2023 report is the second update to the Disposal Research (DR) Research and Development (R&D) 5-year plan for the Spent Fuel and Waste Science and Technology (SFWST) Campaign DR R&D activities. In the planning for FY2020 in the U.S. Department of Energy (DOE) NE-81 SFWST Campaign, the DOE requested development of a high-level summary plan for activities in the DR R&D program for the next five (5)-year period, with periodic updates to this summary plan. The DR R&D 5-year plan was provided to the DOE based initially on the FY2020 priorities and program structure (initial 2020 version of this 5-year plan) and provides a strategic summary guide to the work within the DR R&D technical areas (Control Accounts, CA), focusing on the highest priority technical thrusts. This 5-year plan is a living document (planned to be updated periodically) that provides review of SFWST R&D accomplishments (as seen on the 2021 revision of this 5-year plan), describes changes to technical R&D prioritization based on (a) progress in each technical area (including external technical understanding) with specific accomplishments and (b) any changes in SFWST Campaign objectives and/or funding levels (i.e., Program Direction). Updates to this 5-year plan include the DR R&D adjustments to high-priority knowledge gaps to be investigated in the near-term, as well as the updated longer-term DR R&D directions for the program activities. This plan fulfills the Milestone M2SF23SN010304083 in DR Work Package (WP) SF-23SN01030408 (GDSA - Framework Development – SNL).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building America Case Study: Multifamily Zero Energy Ready Home Analysis, Elmsford, New York

Two multifamily buildings planned in Climate Zone 4 were analyzed to determine the cost, energy and performance implications of redesigning them to comply with Zero Energy Ready Home, a recognition program of the U.S. Department of Energy. Energy modeling was conducted on one representative apartment in each building using BEopt. Construction costs were obtained from the developer and subcontractors to determine savings and cost increases over ENERGY STAR. It was found that seven items would be necessary to change to comply with ZERH criteria when starting from the original design which was compliant with ENERGY STAR version 3.0. Design changes were made to the exterior walls, domestic water heating system, duct protection, duct design, garage ventilation, and pest control to comply with ZERH requirements. Energy impacts of upgrading from the original design to ZERH resulted in 2 to 8 percent reduction in modeled source energy consumption, or 1.7 to 10.4 MMBtu per year, although the original design was already about 8 percent better than a design configured to minimum ENERGY STAR criteria. According to the BEopt analysis, annualized energy related costs of the ZERH design were slightly higher for the apartment and slightly lower for the townhome when compared to the original design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solid state grain alignment of permanent magnets in near-final shape

Magnet microstructure manipulation in the solid state by controlled application of a sufficient stress in a direction during high temperature annealing in a single-phase region of heat-treatable magnet alloys, e.g., alnico-type magnets is followed by magnetic annealing and draw annealing to improve coercivity and saturation magnetization properties. The solid-state process can be termed highly controlled abnormal grain growth (hereafter AGG) and will make aligned sintered anisotropic magnets that meet or exceed the magnetic properties of cast versions of the same alloy types.

Anderson, Iver E.↗

Solid state grain alignment of permanent magnets in near-final shape

Magnet microstructure manipulation in the solid state by controlled application of a sufficient stress in a direction during high temperature annealing in a single-phase region of heat-treatable magnet alloys, e.g., alnico-type magnets is followed by magnetic annealing and draw annealing to improve coercivity and saturation magnetization properties. The solid-state process can be termed highly controlled abnormal grain growth (hereafter AGG) and will make aligned sintered anisotropic magnets that meet or exceed the magnetic properties of cast versions of the same alloy types.

Anderson, Iver E.↗