Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “unit testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Extremely Low Resource Optical Identifier: A License Plate for Your Satellite

Space object identification is vital for operating spacecraft, space traffic control, and space situational awareness, but initial determination, maintenance, and recovery of identity are all difficult, expensive, and error prone, especially for small objects like CubeSats. Attaching a beacon or license plate with a unique identification number to a space object before launch would greatly simplify the task, but radio beacons are power hungry and can cause interference. This work describes a new concept for a satellite license plate: the extremely low resource optical identifier. The extremely low resource optical identifier is a milliwatt-scale self-powered autonomous optical beacon that can be attached to any space object to transmit a persistent identification signal to ground stations. A system appropriate for a low-Earth-orbit CubeSat or other small space object can fit in a package with the area of a postage stamp and a few millimeters thick; and it requires no power, data, or control from the host object. The concept has been validated with ground tests, and the first flight-test unit is scheduled for launch in 2018. The unique identification number of a low-Earth-orbit satellite can be determined unambiguously in a single orbital pass over a low-cost ground station.

79 ASTRONOMY AND ASTROPHYSICS↗

Transformers and Long Short-Term Memory Transfer Learning for GenIV Reactor Temperature Time Series Forecasting

Automated monitoring of the coolant temperature can enable autonomous operation of generation IV reactors (GenIV), thus reducing their operating and maintenance costs. Automation can be accomplished with machine learning (ML) models trained on historical sensor data. However, the performance of ML usually depends on the availability of large amount of training data, which is difficult to obtain for GenIV, as this technology is still under development. We propose the use of transfer learning (TL), which involves utilizing knowledge across different domains, to compensate for this lack of training data. TL can be used to create pre-trained ML models with data from small-scale research facilities, which can then be fine-tuned to monitor GenIV reactors. In this work, we develop pre-trained Transformer and long short-term memory (LSTM) networks by training them on temperature measurements from thermal hydraulic flow loops operating with water and Galinstan fluids at room temperature at Argonne National Laboratory. The pre-trained models are then fine-tuned and re-trained with minimal additional data to perform predictions of the time series of high temperature measurements obtained from the Engineering Test Unit (ETU) at Kairos Power. The performance of the LSTM and Transformer networks is investigated by varying the size of the lookback window and forecast horizon. The results of this study show that LSTM networks have lower prediction errors than Transformers, but LSTM errors increase more rapidly with increasing lookback window size and forecast horizon compared to the Transformer errors.

LSTM↗

Hardware Selection and Performance of Low-Cost Fluorometers

Access to and extensive use of fluorometric analyses is limited, despite its extensive utility in environmental transport and fate. Wide-spread application of fluorescent tracers has been limited by the prohibitive costs of research-grade equipment and logistical constraints of sampling, due to the need for high spatial resolutions and access to remote locations over long timescales. Recently, low-cost alternatives to research-grade equipment have been found to produce comparable data at a small fraction of the price for commercial equipment. Here, we prototyped and benchmarked performance of a variety of fluorometer components against commercial units, including performance as a function of tracer concentration, turbidity, and temperature, all of which are known to impact fluorometer performance. While component performance was found to be comparable to the commercial units tested, the best configuration tested obtained a functional resolution of 0.1 ppb, a working concentration range of 0.1 to >300 ppb, and a cost of USD 59.13.

42 ENGINEERING↗

Observation and Estimation of Evapotranspiration from an Irrigated Green Roof in a Rain-Scarce Environment

While the rain-driven evapotranspiration (ET) process has been well-studied in the humid climate, the mixed irrigation and rain-driven ET process is less understood for green roof implementations in dry regions, where empirical observations and model parameterizations are lacking. This paper presents an effort of monitoring and simulating the ET process for an irrigated green roof in a rain-scarce environment. Annual ET rates for three weighing lysimeter test units with non-vegetated, sedums, and grass covers were 2.01, 2.52, and 2.69 mm d -1 , respectively. Simulations based on the three Penman–Monteith equation-derived models achieved accuracy within the reported range of previous studies. Compared to the humid climate, the overestimation of high ET rates by existing models is expected to cause a larger error in dry environments, where the enhanced ET process caused by repeated irrigations overlapped with hot, dry conditions often occurs during summer. The studied sedum species did not show significantly lower ET rates than native species, and could not effectively take advantage of the deep moisture storage. Therefore, native species, instead of the shallow-rooted species commonly recommended in humid climates, might be a better choice for green roofs in rain-scarce environments.

54 ENVIRONMENTAL SCIENCES↗

gcamdata: An R Package for Preparation, Synthesis, and Tracking of Input Data for the GCAM Integrated Human-Earth Systems Model

The increasing data requirements of complex models demand robust, reproducible, and transparent systems to track and prepare models’ inputs. Here we describe version 1.0 of the gcamdata R package that processes raw inputs to produce the hundreds of XML files needed by the GCAM integrated human-earth systems model. It features extensive functional and unit testing, data tracing and visualization, and enforces metadata, documentation, and flexibility in its component data-processing subunits. Although this package is specific to GCAM, many of its structural pieces and approaches should be broadly applicable to, and reusable by, other complex model/data systems aiming to improve transparency, reproducibility, and flexibility.

54 ENVIRONMENTAL SCIENCES↗

EVA maneuvering unit comparison.

Unstabilized astronaut, hand-held and integrated life support EVA maneuvering units tested in gimbaled six degree of freedom servo driven moving base simulator

Tobey, W. H.↗

Thermomechanical piston pump development

A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.

Sabelman, E. E.↗

Development of improved pyroelectric detectors. Measurements of pyroelectric material characteristics and FET characteristics

Research was undertaken to improve the detectivity of the pyroelectric detector with the ultimate goal of operation at or near the temperature-noise limit. Two general areas of investigation were undertaken: (1) to improve responsivity through the use of new materials; and (2) to reduce noise through improved field effect transistor characteristics, and improved electroding of the pyroelectric material. FET's are being obtained from various manufacturers, evaulated, and selected units tested for evaluation of characteristics critical to their use as preamplifiers with pyroelectric detectors.

Weiner, S.↗

End-to-end test of the electron-proton spectrometer

A series of end-to-end tests were performed to demonstrate the proper functioning of the complete Electron-Proton Spectrometer (EPS). The purpose of the tests was to provide experimental verification of the design and to provide a complete functional performance check of the instrument from the excitation of the sensors to and including the data processor and equipment test set. Each of the channels of the EPS was exposed to a calibrated beam of energetic particles, and counts were accumulated for a predetermined period of time for each of several energies. The counts were related to the known flux of particles to give a monodirectional response function for each channel. The measured response function of the test unit was compared to the response function determined for the calibration sensors from the data taken from the calibration program.

Cash, B. L.↗

Nondestructive testing of electro thermal devices

This paper describes the results of a recent investigation into 'thermal time constant' nondestructive testing of high reliability electrical fuses. The use of established nondestructive test technology for examining the quality and firing characteristics of electro-explosive devices has been successfully applied to the inspection and prediction of the functional performance of electrical fuses. The technique requires application of a low level current pulse to the electrical fuse with an oscilloscope display of the curve as generated by the temperature coefficient of resistance feedback. The heating curve of temperature vs time is composed of one predominant thermal time constant, which is the product of the test unit's thermal capacity and thermal resistance. It has been found that the quality of the individual electrical fuse, for instance, the relative condition of the critical internal weld or solder joint, can be examined nondestructively.

Earnest, J. E., Jr.↗

Design and testing of an energy flywheel for an Integrated Power/Attitude Control System /IPACS/

This paper summarizes the design of a prototype flywheel energy storage assembly developed to evaluate the spacecraft Integrated Power and Attitude Control System (IPACS) concept. In the IPACS application, the flywheel assembly is used for kinetic electrical energy storage as well as conventional angular momentum control. The kinetic energy storage function dictates high rotational speeds which require new approaches to the design of the major components: rotors, motor-generators, bearing systems, and electronics. The paper includes a general description of a NASA-contracted prototype assembly, a discussion of major component design characteristics, and the presentation of preliminary test results as compared with analytical predictions. The test data were obtained from preliminary tests of the NASA prototype assembly as well as from a Rockwell prototype test unit.

Notti, J. E.↗

Statistical properties of filtered pseudo-random digital sequences

A tutorial presentation of pseudo-random digital sequences, their generation and properties is given. The results of a study of filtered pseudo-random sequences, and their statistical properties are reported. The generator, to be used in a telemetry communications system test unit, must generate its pseudo-random signals by filtering a long digital sequence. Desired signal properties include: (1) approximately Gaussian amplitude probability density function; and (2) signal spectral envelope approximately that of the filter being used in the generator. Filtered maximum-length sequences have been used for this, and similar applications in the past. The results were good for low-pass filtered sequences when the ratio of digital clock frequency to filter cutoff frequency was between fifteen and twenty. However, for higher values of this ratio, a definite skewing of the amplitude density function was observed.

Weathers, G. D.↗

Thermal analyses of the International Ultraviolet Explorer (IUE) scientific instrument using the NASTRAN thermal analyzer (NTA): A general purpose summary

The NTA Level 15.5.2/3, was used to provide non-linear steady-state (NLSS) and non-linear transient (NLTR) thermal predictions for the International Ultraviolet Explorer (IUE) Scientific Instrument (SI). NASTRAN structural models were used as the basis for the thermal models, which were produced by a straight forward conversion procedure. The accuracy of this technique was sub-sequently demonstrated by a comparison of NTA predicts with the results of a thermal vacuum test of the IUE Engineering Test Unit (ETU). Completion of these tasks was aided by the use of NTA subroutines.

Jackson, C. E., Jr.↗

High-resolution gray-scale recorder

Electronic circuit makes it possible to obtain gray-scale recordings with good contrast and linearity over entire recording density range for ultrasonic testing unit. Electronic circuit produces square wave of constant voltage but of varying width. Frequency of square-wave pulses can be adjusted to determine optimum pulse frequency.

Moorhead, P. E.↗

A directional filter diplexer using optical techniques for millimeter to submillimeter wavelengths

An optical diplexer for injection of a local oscillator into a mixer, useful in the submillimeter and short millimeter range, is described. It has very low insertion loss for both the signal and local oscillator (LO) and high rejection of LO noise. The measured performance of a unit tested at 337 GHz indicates a loss of about 0.2 dB for both inputs and 20-dB noise rejection.

Erickson, N. R.↗

The 25 kW power module evolution study. Part 3: Conceptual designs for power module evolutions. Volume 3: Cost estimates

Cost data generated for the evolutionary power module concepts selected are reported. The initial acquisition costs (design, development, and protoflight unit test costs) were defined and modeled for the baseline 25 kW power module configurations. By building a parametric model of this initial building block, the cost of the 50 kW and the 100 kW power modules were derived by defining only their configuration and programmatic differences from the 25 kW baseline module. Variations in cost for the quantities needed to fulfill the mission scenarios were derived by applying appropriate learning curves.

Source record↗