Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Multiple relaxation and inhomogeneous broadening in resonance enhanced Raman scattering - Application to tunable infrared generation

The solutions for the imaginary susceptibility of the Raman field transition with arbitrary relaxation rates and field strengths are examined for differing sets of relaxation rates with emphasis on alkali metal vapors which have spontaneous emission dominated relaxation. The model is further expanded to include Doppler broadening and used to predict the peak gain as a function of detuning for a frequency doubled alexandrite laser-pumped cesium vapor gain cell.

Ryan, J. C.↗

Growth and characterization of materials for tunable lasers in the near infrared spectral region

Laser spectroscopy, crystal growth, and radiation damage research was performed. The laser spectroscopy effort focused on understanding the effects of excited state absorption processes involving pump photons. This was performed on a variety of rare earth ions in different hosts. The crystal growth and radiation damage effort focused on LiFY4 (YLF) doped with rare earth ions. The results of this work is described.

Powell, Richard C.↗

Operation of a step tunable megawatt gyrotron

An electron cyclotron resonance maser; gyrotron fundamental oscillator; advantages of gyrotrons; a schematic of the experiment; gyrotron design theory; 1 MW design parameters; compact ignition tokamak; and a gyrotron with quasi-optical output coupler are briefly presented. This presentation is represented by viewgraphs only.

Kreischer, K. E.↗

In situ stratospheric measurements of HNO3 and HCl near 30 km using the balloon-borne laser in situ sensor tunable diode laser spectrometer

In situ stratospheric measurements of the concentrations of the reservoir species HNO3 and HCl made during two flights of the high-resolution (0.0005/cm) balloon-borne laser in situ sensor instrument from Palestine, Texas, are reported. A measured HNO3 volume mixing ratio of 4.3 parts per billion by volume (ppbv) at 31 km altitude is about 1 ppbv larger than previously reported measurements at 32 deg N. An HCl mixing ratio of 1.6 ppbv at 29 km is in agreement with values obtained from earlier remote sensing techniques within the experimental uncertainties. Upper limits at 31 km of 0.4 ppbv for H2O2 and 0.2 ppbv for HOCl are also derived from analyses of spectra recorded near 1252/cm.

May, R. D.↗

Accurate frequency of the 119 micron methanol laser from tunable far-infrared absorption spectroscopy

High-accuracy absorption spectroscopy of CH3OH in the far infrared is discussed. In addition to 22 transitions in the ground state, the frequency of the (n, tau, J, K), (0, 1, 16, 8) to (0, 2, 15, 7) transition in the nu5 excited vibrational level, which is responsible for the laser emission at 119 microns, was measured. The measured frequency is 2,522,782.57(10) MHz at zero pressure, with a pressure shift of 6.1(32) kHz/Pa (0.805/420/ MHz/torr). An accurate remeasurement of the laser emission frequency has also been performed, and the results are in good agreement.

Inguscio, M.↗

ATLAS: Airborne Tunable Laser Absorption Spectrometer for stratospheric trace gas measurements

The ATLAS instrument is an advanced technology diode laser based absorption spectrometer designed specifically for stratospheric tracer studies. This technique was used in the acquisition of N2O tracer data sets on the Airborne Antarctic Ozone Experiment and the Airborne Arctic Stratospheric Expedition. These data sets have proved valuable for comparison with atmospheric models, as well as in assisting in the interpretation of the entire ensemble of chemical and meteorological data acquired on these two field studies. The N2O dynamical tracer data set analysis revealed several ramifications concerning the polar atmosphere: the N2O/NO(y) correlation, which is used as a tool to study denitrification in the polar vertex; the N2O Southern Hemisphere morphology, showing subsidence in the winter polar vortex; and the value of the N2O measurements in the interpretation of ClO, O3, and NO(y) measurements and of the derived dynamical tracer, potential vorticity. Field studies also led to improved characterization of the instrument and to improved accuracy.

Loewenstein, Max↗

Tunable far infrared studies of molecular parameters in support of stratospheric measurements

The purpose of this research is to make precise, fully line-resolved measurements of molecular parameters that are necessary for the analysis of spectra obtained in far infrared field measurement programs. These measurements make it possible to accurately analyze the data from field measurements to obtain atmospheric concentration profiles of key trace gases involved in the ozone chemistry. The research objectives include: measurements of pressure broadening of molecular lines of OH, O2, O3, HCl, and H2O, their temperature dependence, and, when possible, the pressure-induced frequency shifts of the lines; measurements of line positions of radical species, such as HO2.

Chance, K. V.↗

In situ stratospheric measurements of CH4, (C-13)H4, N2O, and OC(O-18) using the BLISS tunable diode laser spectrometer

Simultaneous in situ measurements of stratospheric CH4, (C-13)H4, N2O, OC(O-18), pressure, and temperature have been made from Palestine, Texas (32 deg N) in September 1988 with the JPL Balloon-borne Laser In Situ Sensor. Measurements of CH4 and N2O in the altitude range 30-35 km agree well with other measurements, except for an anomalously high value for the N2O at 31 km. Measurements of CH4 support earlier observations of fold in the vertical profile. A ratio for stratospheric (C-13)H4/CH4 of 0.0105 +/- 0.0010 implies an enrichment of delta(C-13) = -45 +/- 92 parts per thousand over the PDB value, in agreement with previous measurements in the troposphere. A large mixing ratio of 1.9 +/- 0.2 ppmv for OC(O-18) is measured, corresponding to an enrichment of delta(O-18) = 280 +/- 50 parts per thousand for the (O-18) isotopic species over the SMOW value.

Webster, Christopher R.↗

Acousto-optic tunable filter (AOTF) imaging spectrometer for NASA applications - System issues

A recently developed AOTF operating in the visible, 0.4-0.8 micron bandpass is presently compared with other spectrometer designs, with a view to the advantages it may uniquely offer for prospective NASA missions. Since spectral identification is accomplished by this system through the scanning of a few spectral bands, data storage requirements for spectral image analysis can be significantly reduced. Attention is given to spectral and imaging capabilities and their applicability to defense, remote sensing, and industrial uses.

Yu, Jeffrey↗

Amplified spontaneous emission measurement of a line-narrowed, tunable, Ti:Al2O3 amplifier using rubidium absorption

Amplified spontaneous emission, ASE, generated by a Ti:Al2O3 laser amplifier has been measured as a function of pump energy, and thus gain, using the atomic absorption of rubidium, Rb, gas at 0.780 micron. By tuning the Ti:Al2O3 laser, the Rb cell could selectively absorb the narrow spectral bandwidth laser radiation while transmitting the wide spectral bandwidth ASE. Transmission of laser amplifier pulses through a Rb absorption cell, measured at various temperatures, thus allows the measurement of the weak ASE in the vicinity of the strong laser pulse. A model for the transmission of Rb as a function of temperature and wavelength has been developed. The measured transmissions are in good agreement with the transmission model predictions.

Barnes, James C.↗

A tunable CMOS constant current source

A constant current source has been designed which makes use of on chip electrically erasable memory to adjust the magnitude and temperature coefficient of the output current. The current source includes a voltage reference based on the difference between enhancement and depletion transistor threshold voltages. Accuracy is +/- 3% over the full range of power supply, process variations, and temperature using eight bits for tuning.

Thelen, D.↗