Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “titanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Toward high laser power beam manipulation with nanophotonic materials: evaluating thin film damage performance

Nanophotonic materials enable unprecedented control of light-matter interactions, including the ability to dynamically steer or shape wavefronts. Consequently, nanophotonic systems such as metasurfaces have been touted as promising candidates for free-space optical communications, directed energy and additive manufacturing, which currently rely on slow mechanical scanners or electro-optical components for beam steering and shaping. However, such applications necessitate the ability to support high laser irradiances (> kW/cm 2 ) and systematic studies on the high-power laser damage performance of nanophotonic materials and designs are sparse. Here, we experimentally investigate the pulsed laser-induced damage performance (at λ ∼ 1 µm) of model nanophotonic thin films including gold, indium tin oxide, and refractory materials such as titanium nitride and titanium oxynitride. We also model the spatio-thermal dissipation dynamics upon single-pulse illumination by anchoring experimental laser damage thresholds. Our findings show that gold exhibits the best laser damage resistance, but we argue that alternative materials such as transparent conducting oxides could be optimized to balance the tradeoff between damage resistance and optical tunability, which is critical for the design of thermally robust nanophotonic systems. We also discuss damage mitigation and ruggedization strategies for future device-scale studies and applications requiring high power beam manipulation.

36 MATERIALS SCIENCE↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Image quality indicator and dechromator setup for static LANSCE proton radiography experiment

This document describes a static geometry consisting of a sphere of gold and Ti-6Al-4V alloy, along with an energy-loss matching dechromator composed of polycarbonate, to field with the X3 electromagnetic magnifying lens at LANSCE during the next beam cycle. This static configuration will allow us to: (1) characterize the system’s resolution at the material interface between the gold and titanium alloy, and test the image quality for fine features associated with the screws used to fasten the titanium alloy hemispheres; (2) tune our models of proton scattering and imaging for these materials; and (3) test a procedure to align the polycarbonate dechromator and the sphere within the proton beamline. The data will also be suitable for validation of the software options available for proton radiography simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history. Actual Titanium values are believed to be less than 10g on any given filter. Actual Tantalum values are believed to be less than 1g on any given filter

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cobalt-Free Cathodes for Next Generation Li-Ion Batteries

In this U.S. Department of Energy sponsored project Nexceris, in collaboration with project partners; The Ohio State University and Navitas Advanced Systems have advanced the technical maturity of a non-cobalt containing cathode for next-generation Li-ion batteries. The cathode is based on the lithium manganese nickel-titanium oxide, LiNi 0.5 Mn 1.5 TiO 4 (LNMTO) high voltage spinel. To address limitations with poor cycle and calendar life an microstucturally hierarchical LNMO/LNMTO core-shell cathode powder has been developed that enables the formation of a solid-electrolyte interface that effectively passivates the cathode surface. The microstructural enhancements of the cathode material focus on preferentially enriching the surface with titanium. In parallel, new, optimized binder and electrolyte chemistries have been incorporated to address degradation mechanisms associated with high-voltage systems. Single-layer pouch cell and large-format 2-Ah cell testing have shown that an optimized LNMO/LNMTO core-shell powder significantly improves initial cell capacity and cycle life compared to homogeneous LNMO powder. To support development and the fabrication of 2-Ah cells a novel Hybrid Alternative Wet-Chemical Synthesis (HAWCS) process have been developed. This low-cost, synthesis approach enables the excellent compositional and particle morphology control achieved with co-precipitation without the strict process controls and associated expensive process equipment.

25 ENERGY STORAGE↗

Responses to Nonconformances, AIHA Onsite Assessment August 29-31, 2022

A nonconformance report (NCR) was not generated to document the original Beryllium (Be) positive result being changed to negative due to an oversight by the lab. The sample was re-analyzed on the Agilent ICP-OES which includes software to deal with interferences and resulted in a negative for Be. In order to determine the cause of the false positive, which was originally thought to be due to the Titanium interference in the sample, the laboratory analyzed a blank and a reporting limit standard with 5 ppm and 10 ppm of Titanium added in. These were analyzed on the Perkin Elmer ICP 5 instrument to see if the positive Be was reproducible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Phase and Interfacial Effects of Spall Fracture in Additively Manufactured Ti-5Al-5V-5Mo-3Cr

Additive manufactured Ti-5Al-5V-5Mo-3Cr (Ti-5553) is being considered as an AM repair material for engineering applications because of its superior strength properties compared to other titanium alloys. Here, we describe the failure mechanisms observed through computed tomography, electron backscatter diffraction (EBSD), and scanning electron microscopy (SEM) of spall damage as a result of tensile failure in as-built and annealed Ti-5553. We also investigate the phase stability in native powder, as-built and annealed Ti-5553 through diamond anvil cell (DAC) and ramp compression experiments. We then explore the effect of tensile loading on a sample containing an interface between a Ti-6Al-V4 (Ti-64) baseplate and additively manufactured Ti-5553 layer. Post-mortem materials characterization showed spallation occurred in regions of initial porosity and the interface provides a nucleation site for spall damage below the spall strength of Ti-5553. Preliminary peridynamics modeling of the dynamic experiments is described. Finally, we discuss further development of Stochastic Parallel PARticle Kinteic Simulator (SPPARKS) Monte Carlo (MC) capabilities to include the integration of alpha (α)-phase and microstructural simulations for this multiphase titanium alloy.

36 MATERIALS SCIENCE↗

Analysis of Solids Obtained from 201O, 201P, 202A, and 202B Contactors in the Salt Waste Processing Facility

In December 2022, Savannah River Mission Completion personnel recovered solids samples from four contractors (EXT-001, EXT-007, EXT-031, and EXT-040) employed at the Salt Waste Processing Facility (SWPF). These solids were submitted to Savannah River National Laboratory for analysis and characterization. This Technical Report outlines the analytical findings and observations associated with these samples and explores the potential source of solid generation within the SWPF. The following conclusions are offered as a result of this work: the light color solids recovered from EXT-007 are consistent with crystallized, soluble salt components (such as sodium nitrate, sodium hydroxide, and sodium carbonate), all of which can be easily re-dissolved in process water and do not represent a threat to SWPF CSSX processing. While the light solids from the top of EXT-040 were not analyzed, it is believed that they share similar characteristics to those recovered from EXT-007; The dark color solids recovered from EXT-001, EXT-031, and the inside of EXT-040 appear to be complex, consisting of several different types of solids: High concentrations of mercury (Hg, 40-75% by mass) partially present as elemental Hg are consistent with the precipitation of Hg 0 /Hg 2+ from disproportionation of Hg + species in pH swing conditions; Moderate concentrations of titanium (Ti) (2-7%, by mass) are also present, often co-located with Hg. This is consistent with co-precipitation, entrainment, and/or amalgamation of Ti and Hg; Moderate concentrations of iron (Fe) (1-3%, by mass) are observed in SWPF solids and are likely attributable to erosion of stainless-steel components within the CSSX process; Small concentrations of tungsten (W) and cobalt (Co) (<1%, by mass) are observed in SWPF solids. The presence of these solids is consistent with the erosion of components coated with W and Co (e.g., Stellite); Small concentrations of aluminum (Al) (<1%, by mass) are observed in the form of gibbsite and potentially sodium aluminosilicate. The presence of these compounds is likely attributable to the pH swing observed between the scrub and extraction cycles within the CSSX process. The following recommendations are made as a result of this work: Testing should be performed to determine the chemical drivers, process, and mechanism of Hg precipitation in CSSX processing. Special care should be taken to include titanium in tests to evaluate the potential for co-precipitation, entrainment, and amalgamation; Hg-mitigation options that would minimize or eliminate risks of Hg precipitation and solids accumulation (e.g., Hg-absorption techniques, ion exchange/adsorbents, flowsheet changes, etc.) should be assessed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electromagnetic Radioisotope Separator for Methods Development, Testing, and Training

The major goal of the project is the construction and operation of an electromagnetic isotope separator. Included in that goal is the construction and installation of a high throughput surface ion source, with specific applicability to the Lanthanides. The surface ion source features a single-piece titanium crucible insert that mates with a tantalum hot surface ionizer. The titanium crucible, which does not readily activate, can be loaded with samarium and then irradiated simultaneously, greatly reducing operator dose.

07 ISOTOPE AND RADIATION SOURCES↗

Thermal Analysis and Simulations of the Abort Kicker Magnets Systems for the Electron-Ion Collider

The Abort Kicker Magnets system used in the current Relativistic Heavy Ion Collider (RHIC) to steer the circulating beam into the dump will be subjected to higher heat loads in the Electron-Ion Collider (EIC). After analyzing the existing abort kicker magnets and running thermal simulations in ANSYS it was concluded that they may not be suitable for use as-is in the future EIC due to heat and impedance concerns in the magnets. Possible solutions include adding a round titanium-coated ceramic beam tube to help solve the heat and impedance concerns, but this will reduce the limiting aperture of the kicker magnet. Another possible solution to meet all the performance requirements for EIC would be to add titanium-coated ceramic plates with water-cooling and tapered transitions that significantly improve the impedance and lower the heat in the magnets with less reduction to the aperture.

43 PARTICLE ACCELERATORS↗

Rheo–Electric Foundations and Engineering of Carbon Slurry Flow Electrodes

Flowable carbon slurry electrodes promise continuous, scalable electrochemical desalination and energy storage when their rheology (flow and stability) and electronic connectivity are jointly optimized. This report integrates six complementary thrusts that we executed under the Laboratory Directed Research and Development (LDRD) project: (i) a fast, ex situ, centrifuge-compatible method to quantify pellet (packed slurry) electronic conductivity, with a validated cell constant (“shape factor”) and quantitative structure–property insights for carbon mixtures; (ii) a controlled circulation study showing that peristaltic pumping can irreversibly alter particle size and morphology over laboratory-relevant durations; (iii) development of a miniature jet pump that preserves particle integrity while achieving entrainment ratios of 2–4 at practical flow rates; (iv) a comprehensive mapping of how a representative non-ionic surfactant (Tween 20) collapses the carbon gel network, separating network-percolation losses from intrinsic particle contact resistance; (v) in-situ visualization revealing how gravitational settling and flow-driven mixing compete to control charge transport, with dynamic bed layers preventing saturation while achieving 30-fold local concentration enhancement; and (vi) a simple, widely adoptable fabrication route to structured, gas-nitrided titanium nitride (TiN) titanium current collectors that dramatically lower interfacial losses and enable geometry-driven performance gains. Together, these results provide a coherent toolchain and design rules to accelerate formulation screening, de-risk device prototyping, and standardize characterization for carbon slurry electrodes in flow-electrode capacitive deionization (FCDI), electrochemical flow capacitor (EFC), and related systems.

25 ENERGY STORAGE↗

Towards a Unified Low-Cost Flow Plate, Flow-Field, PTL Solution for Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolysis is a highly efficient method for hydrogen production. Research cells typically consist of one proton exchange membrane, two catalyst layers, two porous transport layers, two flow-field plates, and two endplates. In commercial systems, the machined flow-field plates that are employed in research cells are typically replaced by stamped parts or open mesh material solutions to reduce manufacturing cost at scale. Nonetheless, the cell contains about 8 total interfaces: bipolar plate / flow plate material / porous transport medium / electrode / membrane / electrode / porous transport medium / flow plate material / bipolar plate. All these materials and interfaces need to be optimized for maximum performance and efficiency. Reducing the amount of interfaces by combining individual cell components directly benefits the fabrication cost (by reducing the parts count and the needs for surface coatings) and the electrochemical performance (by reducing ohmic losses). We have designed a novel PEM electrolysis cell with a piece of channeled titanium felt functioning as both the anode flow-field and the PTL, referred to as the channeled diffusion layer (CDL). The pores of the felt facilitate both in-plane and through-plane diffusion, ensuring maximum catalyst utilization while also minimizing mass transport loss. The titanium felt can be mass manufactured with existing stamping and forming methods and is therefore a promising candidate to reduce the capital cost of PEM electrolyzers whilst improving hydrogen production efficiency. Experiments conducted with 3mg IrOx/cm2 loading MEAs have shown a approximately 40% boost in peak current by implementing the CDL design. Low catalyst-loading MEAs are being tested in ongoing experiments and their results will be discussed and compared.

08 HYDROGEN↗

Hydroxyapatite/TiO 2 Nanomaterial with Defined Microstructural and Good Antimicrobial Properties

Due to the growing number of people infected with the new coronavirus globally, which weakens immunity, there has been an increase in bacterial infections. Hence, knowledge about simple and low-cost synthesis methods of materials with good structural and antimicrobial properties is of great importance. A material obtained through the combination of a nanoscale hydroxyapatite material (with good biocompatibility) and titanium dioxide (with good degradation properties of organic molecules) can absorb and decompose bacteria. In this investigation, three different synthesis routes used to prepare hydroxyapatite/titanium dioxide nanomaterials are examined. The morphology and semiquantitative chemical composition are characterized by scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX). The obtained materials’ phase and structural characterization are determined using the X-ray powder diffraction method (XRD). The crystallite sizes of the obtained materials are in the range of 8 nm to 15 nm. Based on XRD peak positions, the hexagonal hydroxyapatite phases are formed in all samples along with TiO 2 anatase and rutile phases. According to SEM and TEM analyses, the morphology of the prepared samples differs depending on the synthesis route. The EDX analysis confirmed the presence of Ti, Ca, P, and O in the obtained materials. The IR spectroscopy verified the vibration bands characteristic for HAp and titanium. The investigated materials show excellent antimicrobial and photocatalytic properties.

60 APPLIED LIFE SCIENCES↗

Intrinsic Defect-Induced Local Semiconducting-to-Metallic Regions Within Monolayer 1T-TiS2 Displayed by First-Principles Calculations and Scanning Tunneling Microscopy

Using density functional theory (DFT) and scanning tunneling microscopy (STM), the intrinsic point defects, formation energy, and electronic structure of 1T-TiS2 were investigated. Defect systems include single-atom vacancies, interstitial and adatom additions, and direct atomic substitution. Using a collective approach for analyzing realistic systems for point defect investigation, we provide a more straightforward comparison to the experimental measurements, reproducing more realistic environmental conditions related to thin film growth. STM images are compared to computationally simulated electron density images to identify specific geometries that result from favorable point defects. DFT suggests that titanium interstitials are the most energetically favorable intrinsic defect, and sulfur vacancies are more likely to form than titanium vacancies within this realistic analysis, which is in agreement with STM data. A pristine, stoichiometric monolayer system is calculated to have a direct band gap of 0.422 eV, which varies based on local point defects. Local semiconducting-to-metallic electronic transitions are predicted to occur based on the presence of Ti interstitials.

Keeney, P. J.↗

Critical feature and seawater testing of cross-flow rotor components fabricated with additive manufacturing

Advanced manufacturing (AM) materials were investigated for their suitability for use in cross-flow turbine rotors. AM materials were categorized into 3 classes – plastics, metals, and ceramics – and reviewed for suitability based on a set of engineering requirements and criteria. Two plastics and two metals were selected to undergo further testing: Essentium CF25, Markforged Onyx, Titanium Ti-6Al-4V, and Inconel 718. Dogbone-shaped specimens were printed from each material in two sets. The first set was tensile tested to get a material baseline. The second set was submerged in the seawater tanks at PNNL-Sequim for 6 months to determine water uptake, corrosion, and biofouling resistance and then subsequently tensile tested. While few macroscopic changes could be observed after seawater testing, the plastic materials degraded significantly as compared to baseline, while the metal material properties remained consistent. Titanium and Inconel are used consistently by industry in extreme conditions, and the materials show promising performance for marine energy use cases.

McVey, James R.↗

A Study of a Surrogate Nuclear Thermal Propulsion Fuel Element

We report a surrogate fuel, Zirconium Carbide/Titanium Nitride has been prepared using a simple method to obtain a more uniform distribution of titanium nitride in the zirconium carbide matrix. Powders were sintered using Spark Plasma Sintering at 1750oC and 1850oC using a modified sintering profile. This resulted in a fairly uniform distribution of titanium nitride in the zirconium carbide matrix with a density of 95% of theoretical at 1850oC. Scanning electron microscopy, indentation hardness and x-ray diffraction results are given.

36 MATERIALS SCIENCE↗

Process for the separation and purification of medical isotopes

The invention provides a method for isolating medical isotopes, the method having the steps of dissolving titanium nuclear targets to create a solution; contacting the solution with a resin so as to retain the isotopes on the resin and generate an eluent containing titanium; contacting the isotope-containing resin with acid of a first concentration to remove impurities from the resin; and contacting the isotope-containing resin with an acid of a second concentration to remove isotope from the resin.

07 ISOTOPE AND RADIATION SOURCES↗