Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tissue imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Deep learning for Alzheimer's disease: Mapping large-scale histological tau protein for neuroimaging biomarker validation

Abnormal tau inclusions are hallmarks of Alzheimer's disease and predictors of clinical decline. Several tau PET tracers are available for neurodegenerative disease research, opening avenues for molecular diagnosis in vivo. However, few have been approved for clinical use. Understanding the neurobiological basis of PET signal validation remains problematic because it requires a large-scale, voxel-to-voxel correlation between PET and (immuno) histological signals. Large dimensionality of whole human brains, tissue deformation impacting co-registration, and computing requirements to process terabytes of information preclude proper validation. We developed a computational pipeline to identify and segment particles of interest in billion-pixel digital pathology images to generate quantitative, 3D density maps. The proposed convolutional neural network for immunohistochemistry samples, IHCNet, is at the pipeline's core. We have successfully processed and immunostained over 500 slides from two whole human brains with three phospho-tau antibodies (AT100, AT8, and MC1), spanning several terabytes of images. Our artificial neural network estimated tau inclusion from brain images, which performs with ROC AUC of 0.87, 0.85, and 0.91 for AT100, AT8, and MC1, respectively. Introspection studies further assessed the ability of our trained model to learn tau-related features. We present an end-to-end pipeline to create terabytes-large 3D tau inclusion density maps co-registered to MRI as a means to facilitate validation of PET tracers.

60 APPLIED LIFE SCIENCES↗

Non-Equilibrium Plasma Interactions with Biomaterials, Biological Solutions and Tissues

Cold atmospheric pressure plasma discharges offer an abundant source of reactive oxygen and nitrogen species (RONS) at room temperature enabling unique interactions with biomaterials, biological solutions and tissues. These interactions particularly with living matter are presently an important intellectual frontier in plasma science with promising potential applications ranging from human health care to advanced biomaterial processing. Exciting case studies have been reported that illustrate the huge potential of cold atmospheric plasma technology in wound healing and cancer treatment. The interaction of plasma with conducting and dielectric biomaterials such as tissue strongly influences the plasma properties. In turn this changes the impact of the plasma on the biomaterial. Particularly in the case of living matter, liquid based solutions are ubiquitous which complicates interfacial processes. The lack of insight into the underlying mechanisms of the interaction of plasma with wounds and tumors is currently a bottleneck for the further development of the technology and gives rise to many interesting scientific questions. This project was focused on plasma properties and kinetics during plasma-biomaterial interactions. Both DC pulsed and RF driven atmospheric pressure plasma jets, extensively used by the plasma community were studied. The bio-interfaces included hydrogel as a tissue model, (saline) solutions, bacteria and virus. Plasma diagnostics used include Thomson scattering, Rayleigh scattering, Raman scattering, (two-photon absorption) laser induced fluorescence, optical emission spectroscopy, absorption spectroscopy, molecular beam mass spectrometry and fast imaging allowing to determine electron densities and temperatures, ionic species, reactive species including radicals, gas temperatures, gas composition, electric fields and solution components transferred to the gas phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution echocardiography

High resolution computer aided ultrasound system provides two-and three-dimensional images of beating heart from many angles. System provides means for determining whether small blood vessels around the heart are blocked or if heart wall is moving normally without interference of dead and noncontracting muscle tissue.

Nathan, R.↗

Portable Electron Microscopy for ISS and Beyond

Advances in space exploration have evolved in lockstep with key technology advances in diverse fields such as materials science, biological science, and engineering risk management. Research in these areas, where structure and physical processes come together, can proceed rapidly in part due to sophisticated ground-based analytical tools that help re-searchers develop technologies and engineering processes that push frontiers of human space exploration. Electron microscopes (EM) are an example of such a workhorse tool, lending a unique blend of strong optical scattering, high native resolution, large depth of focus, and spectroscopy via characteristic X-ray emission, providing exquisite high-magnification structural imaging and chemical analysis. Ground-based EM’s have been essential in NASA research for many years. In particular, in mineralogy and petrology, EM is used to understand the origin and evolution of the solar system, particularly rocky bodies. In microbiology, EM has helped visualize the architecture of tissues and cells. In engineering/materials science, EM has been used to characterize particulate debris in air and water samples, determine pore sizes in ceramics/catalysts, understand the nature of fibers, determine composition and morphology of new and existing materials, and characterize micro-textures of vapor deposited films. EM is highly effective at investigating a wide variety of nanoscale materials/biomaterials at the core of many of NASA’s inquiries. Despite exquisite optical performance and versatility, EM’s are traditionally large, heavy, and have high power consumption. They are also expensive so they tend to be housed at universities and large research institutions, or at major industrial laboratory sites with support staff, supplies, and skilled operators. Since most organizations cannot support their own EM, samples are often sent to these large institutions and service centers to be imaged, at great expense and of-ten with delay of weeks to months for complex analyses. Complexity, high cost, and maintenance associated with collecting EM image data has until now severely limited fields in which EM is used. Making EM accessible outside constrained terrestrial laboratory environments will bring EM’s performance and versatility to a much broader range of scientific and engineering endeavors, including in space.

Own, C. S.↗

Spatiotemporal metabolic responses to water deficit stress in distinct leaf cell-types of poplar

The impact of water-deficit (WD) stress on plant metabolism has been predominantly studied at the whole tissue level. However, plant tissues are made of several distinct cell types with unique and differentiated functions, which limits whole tissue ‘omics’-based studies to determine only an averaged molecular signature arising from multiple cell types. Advancements in spatial omics technologies provide an opportunity to understand the molecular mechanisms underlying plant responses to WD stress at distinct cell-type levels. Here, we studied the spatiotemporal metabolic responses of two poplar ( Populus tremula× P. alba ) leaf cell types -palisade and vascular cells- to WD stress using matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI). We identified unique WD stress-mediated metabolic shifts in each leaf cell type when exposed to early and prolonged WD stresses and recovery from stress. During water-limited conditions, flavonoids and phenolic metabolites were exclusively accumulated in leaf palisade cells. However, vascular cells mainly accumulated sugars and fatty acids during stress and recovery conditions, respectively, highlighting the functional divergence of leaf cell types in response to WD stress. By comparing our MALDI-MSI metabolic data with whole leaf tissue gas chromatography-mass spectrometry (GC-MS)-based metabolic profile, we identified only a few metabolites including monosaccharides, hexose phosphates, and palmitic acid that showed a similar accumulation trend at both cell-type and whole leaf tissue levels. Overall, this work highlights the potential of the MSI approach to complement the whole tissue-based metabolomics techniques and provides a novel spatiotemporal understanding of plant metabolic responses to WD stress. This will help engineer specific metabolic pathways at a cellular level in strategic perennial trees like poplars to help withstand future aberrations in environmental conditions and to increase bioenergy sustainability.

59 BASIC BIOLOGICAL SCIENCES↗

Spatial Glycomics and Kidney Disease

Glycans are critical for the kidney's physiological and pathological cellular functions, and our ability to reveal their spatial distributions within tissues has helped us reveal how these carbohydrate moieties are involved in many of these processes. This review discusses the role of different types of glycans in kidney biology and disease, common approaches used for glycan imaging, and how glycan imaging has helped us better understand kidney pathology. Here, we mainly focus on emerging methods using mass spectrometry imaging (MSI) because this technology is untargeted and provides complete information on glycan composition compared to the other methods, such as lectin and metabolite labeling, which are targeted and often inform only on the specific part of a glycan structure. We especially focus on protein N-glycosylation, as this is one of the most common post-translational modifications, and these moieties play a vital role in renal structure and function. The recent advancements in MSI of N-glycans we reviewed have provided new insights into the pathophysiology of the kidney and paved the way for clinical application.

60 APPLIED LIFE SCIENCES↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Biophotonics and Bone Biology

One of the more serious side effects of extended space flight is an accelerated bone loss. Rates of bone loss are highest in the weight-bearing bones of the hip and spine regions, and the average rate of bone loss as measured by bone mineral density measurements is around 1.2% per month for persons in a microgravity environment. It is well known that bone remodeling responds to mechanical forces. We are developing two-photon microscopy techniques to study bone tissue and bone cell cultures to better understand the fundamental response mechanism in bone remodeling. Osteoblast and osteoclast cell cultures are being studied, and the goal is to use molecular biology techniques in conjunction with Fluorescence Lifetime Imaging Microscopy (FLIM) to study the physiology of in-vitro cell cultures in response to various stimuli, such as fluid flow induced shear stress and mechanical stress. We have constructed a two-photon fluorescence microscope for these studies, and are currently incorporating FLIM detection. Current progress will be reviewed. This work is supported by the NASA John Glenn Biomedical Engineering Consortium.

Zimmerli, Gregory↗

Probing the electronic properties of the electrified silicon/water interface by combining simulations and experiments.

Silicon (Si) is broadly used in electrochemical and photoelectrochemical devices, where the capacitive and Faradaic reactions at the Si/water interfaces are critical for signal transduction or noise generation. However, probing the electrified Si/water interface at the microscopic level remains a challenging task. Here we focus on hydrogenated Si surfaces in contact with water, relevant to transient electronics and photoelectrochemical modulation of biological cells and tissues. We show that by carrying out first principles molecular dynamics simulations of the Si(100)/water interface in the presence of an electric field we can realistically correlate the computed flat-band potential and tunneling current images at the interface with experimentally measured capacitive and Faradaic currents. Specifically, we validate our simulations in the presence of bias by performing pulsed chronoamperometry measurements on Si wafers in solution. Consistent with prior experiments, our measurements and simulations indicate the presence of voltage-dependent capacitive currents at the interface. We also find that Faradaic currents are weakly dependent on the applied bias, which we relate to surface defects present in newly prepared samples.

Ye, Zifan↗

Deep Learning Approaches to Surrogates for Solving the Diffusion Equation for Mechanistic Real-World Simulations

In many mechanistic medical, biological, physical, and engineered spatiotemporal dynamic models the numerical solution of partial differential equations (PDEs), especially for diffusion, fluid flow and mechanical relaxation, can make simulations impractically slow. Biological models of tissues and organs often require the simultaneous calculation of the spatial variation of concentration of dozens of diffusing chemical species. One clinical example where rapid calculation of a diffusing field is of use is the estimation of oxygen gradients in the retina, based on imaging of the retinal vasculature, to guide surgical interventions in diabetic retinopathy. Furthermore, the ability to predict blood perfusion and oxygenation may one day guide clinical interventions in diverse settings, i.e., from stent placement in treating heart disease to BOLD fMRI interpretation in evaluating cognitive function (Xie et al., 2019; Lee et al., 2020). Since the quasi-steady-state solutions required for fast-diffusing chemical species like oxygen are particularly computationally costly, we consider the use of a neural network to provide an approximate solution to the steady-state diffusion equation. Machine learning surrogates, neural networks trained to provide approximate solutions to such complicated numerical problems, can often provide speed-ups of several orders of magnitude compared to direct calculation. Surrogates of PDEs could enable use of larger and more detailed models than are possible with direct calculation and can make including such simulations in real-time or near-real time workflows practical. Creating a surrogate requires running the direct calculation tens of thousands of times to generate training data and then training the neural network, both of which are computationally expensive. Often the practical applications of such models require thousands to millions of replica simulations, for example for parameter identification and uncertainty quantification, each of which gains speed from surrogate use and rapidly recovers the up-front costs of surrogate generation. We use a Convolutional Neural Network to approximate the stationary solution to the diffusion equation in the case of two equal-diameter, circular, constant-value sources located at random positions in a two-dimensional square domain with absorbing boundary conditions. Such a configuration caricatures the chemical concentration field of a fast-diffusing species like oxygen in a tissue with two parallel blood vessels in a cross section perpendicular to the two blood vessels. To improve convergence during training, we apply a training approach that uses roll-back to reject stochastic changes to the network that increase the loss function. The trained neural network approximation is about 1000 times faster than the direct calculation for individual replicas. Because different applications will have different criteria for acceptable approximation accuracy, we discuss a variety of loss functions and accuracy estimators that can help select the best network for a particular application. We briefly discuss some of the issues we encountered with overfitting, mismapping of the field values and the geometrical conditions that lead to large absolute and relative errors in the approximate solution.

60 APPLIED LIFE SCIENCES↗

The Facial Reconstruction of a Mesolithic Dog, Muge, Portugal

This paper presents the facial reconstruction of a Mesolithic dog whose skeleton was recovered from the Muge shell middens (Portugal) in the 19th century. We used the anatomical deformation approach based on a collection of computer tomography images as an attempt to reconstruct the Muge dog’s head appearance. We faced a few challenges due to the level of bone displacement and the absence of some cranium anatomical parts, as well as accurate information on soft tissue thickness for modern dogs. This multidisciplinary study combined anatomical, veterinary, zooarchaeological, artistic and graphic aspects to allow for the facial reconstruction of the Muge dog. Albeit an approximation, it confers a recognition to this prehistoric finding.

Moraes, Cicero (ORCID:0000000294790028)↗

Vascular Patterning Analysis by VESGEN 2D/3D with Bioinformatics: Updates for Rodent Tissues

Fractally branching vascular systems are a complex physiological requirement shared by humans with all higher terrestrial life forms, including other vertebrates, insects, and higher land plants. Vascular trees, networks, and tree-network composites are therefore mapped and quantified by the VESsel GENeration Analysis (VESGEN) software according to weighted physiological vascular rules that include vessel connectivity, tapering and bifurcational branching. According to fluid dynamics, successful vascular transport depends upon a complex distributed system of highly regulated laminar flow. VESGEN has elucidated changes in vascular patterning resulting from inflammatory, developmental and other signaling pathways within numerous tissues of major model organisms important for Space Biology, especially for rodents. Important early stage regenerative opportunities have been identified by VESGEN vascular analysis for visual impairments in the human retina, and is currently being used for research into astronaut visual and ocular disorders associated with long duration missions. The VESGEN 2D software is a mature, automated, widely published capability for which beta testing and public release by NASA is planned for the upcoming year. Early-stage capabilities for VESGEN 3D analysis are under development for the rodent retina and intestine as prototype tissues. A prototype VESGEN 2D Bioinformatics software capability has also been developed to associate phenotypic changes in molecular expression with vascular structure and function. By new VESGEN bioinformatic innovations, expression patterns of the genetic, transcriptional, protein and other markers for regulatory molecules such as vascular endothelial growth factor (VEGF) and their receptors, often indicators of tissue oxygenation status, are co-localized with alterations in vascular pattern. Biomarkers are therefore mapped and quantified as information dimensions directly correlated with the spatial dimensions of a vascular pattern. Further important technology innovations by NASA include substantial image segmentation advances for more automated binary extraction of the grayscale vascular patterns, together with informative associated image quality assessments. Vascular mapping and quantification capabilities for the rodent retina and intestine are illustrated for VESGEN 2D, along with technology status reports on VESGEN 3D and Bioinformatic capabilities. Research partially supported by Ames Center Innovation Awards.

Parsons-Wingerter, P.↗

Imaging and spatially resolved mass spectrometry applications in nephrology

The application of spatially resolved mass spectrometry (MS) and MS imaging approaches for studying biomolecular processes in the kidney is rapidly growing. These powerful methods, which enable label-free and multiplexed detection of many molecular classes across omics domains (including metabolites, drugs, proteins and protein post-translational modifications), are beginning to reveal new molecular insights related to kidney health and disease. Further, the complexity of the kidney often necessitates multiple scales of analysis for interrogating biofluids, whole organs, functional tissue units, single cells and subcellular compartments. Various MS methods can generate omics data across these spatial domains and facilitate both basic science and pathological assessment of the kidney. Optimal processes related to sample preparation and handling for different MS applications are rapidly evolving. Emerging technology and methods, improvement of spatial resolution, broader molecular characterization, multimodal and multiomics approaches and the use of machine learning and artificial intelligence approaches promise to make these applications even more valuable in the field of nephology. Overall, spatially resolved MS and MS imaging methods have the potential to fill much of the omics gap in systems biology analysis of the kidney and provide functional outputs that cannot be obtained using genomics and transcriptomic methods.

60 APPLIED LIFE SCIENCES↗

Nuclear emulsion measurements of the astronauts' radiation exposures on Skylab missions 2, 3, and 4

On the Skylab missions, Ilford G.5 and K.2 emulsions were flown as part of passive dosimeter packs carried by the astronauts on their wrists. Due to the long mission times, latent image fading and track crowing imposed limitations on a quantitative track and grain count analysis. For Skylab 2, the complete proton energy spectrum was determined within reasonable error limits. A combined mission dose equivalent of 2,490 millirems from protons, tissue stars and neutrons was measured on Skylab 2. A stationary emulsion stack, kept in a film vault drawer on the same mission, displayed a highly structured directional distribution of the fluence of low-energy protons (enders) reflecting the local shield distribution. On the 59 and 84-day mission 3 and 4, G.5 emulsions had to be cut on the microtom to 5-7 microns for microscopic examination. Even so, the short track segments in such thin layers precluded a statistically reliable grain count analysis. However, the K.2 emulsions still allowed accurate proton ender counts without special provisions.

Schaefer, H. J.↗

Sharp-Focus Composite Microscope Imaging by Computer

Enhanced depth of focus aids medical analysis. Computer image-processing system synthesizes sharply-focused composite picture from series of photomicrographs of same object taken at different depths. Computer rejects blured parts of each photomicrograph. Remaining in focus portions form focused composite. System used to study alveolar lung tissue and has applications in medicine and physical sciences.

Wall, R. J.↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

61 RADIATION PROTECTION AND DOSIMETRY↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal electron sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BioTransformer 3.0 – A Web Server for Accurately Predicting Metabolic Transformation Products

BioTransformer 3.0 is a freely available web server that supports accurate, rapid and comprehensive in silico metabolism prediction. It combines machine learning approaches with a rule-based system to predict small-molecule metabolism in human tissues, the human gut as well as the external environment (soil and water microbiota). Simply stated, BioTransformer takes a molecular structure as input (SMILES or SDF) and outputs an interactively viewable/sortable table of the predicted metabolites or transformation products (SMILES, PNG images) along with the enzymes that are predicted to be responsible for those reactions and richly annotated downloadable files (CSV and JSON). The entire process typically takes a few seconds. Previous versions of BioTransformer focused exclusively on predicting the metabolism of xenobiotics (such as plant natural products, drugs, cosmetics and other synthetic compounds) using a limited number of pre-defined steps and somewhat limited rule-based methods. BioTransformer 3.0, uses much more sophisticated methods and incorporates new databases, new constraints and new prediction modules to not only more accurately predict the metabolic transformation products of exogenous xenobiotics but also the transformation products of endogenous metabolites, such as amino acids, peptides, carbohydrates, organic acids, and lipids. BioTransformer 3.0 can also support customized sequential combinations of these transformations along with multiple iterations to simulate multi-step human and/or environmental biotransformation events. Performance tests indicate that BioTransformer 3.0 is 40-50% more accurate, much less prone to combinatorial “explosions” and far more comprehensive in terms of metabolite coverage/capabilities than previous versions of BioTransformer.

59 BASIC BIOLOGICAL SCIENCES↗