Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

AGR-5/6/7 Irradiation As Run Predictions Using PARFUME

The PARticle FUel ModEl (PARFUME), a fuel performance modeling code used for high-temperature gas-cooled reactors, was used to model the Advanced Gas Reactor (AGR)-5/6/7 irradiation test using as-run physics and thermal data. The AGR-5/6/7 irradiation test consists of the combined fifth, sixth, and seventh planned irradiations of the AGR Fuel Development and Qualification Program. The AGR-5/6/7 test train is a multi-capsule, instrumented experiment that is designed for irradiation in the 133.4-mm diameter northeast flux trap position of the Advanced Test Reactor (ATR) at Idaho National Laboratory. Each capsule contains compacts filled with uranium oxycarbide unaltered fuel particles. This report documents the calculations performed to predict the failure probability of tristructural isotropic (TRISO)-coated fuel particles during the AGR-5/6/7 experiment. In addition, this report documents the calculated fission product release fraction from the fuel. The calculations include modeling of the AGR 5/6/7 irradiation that occurred from February 2018 to July 2020 over nine ATR cycles, including six normal cycles and three power axial locator mechanism cycles, for a total of approximately 376 effective full power days (EFPD). The irradiation conditions and material properties of the AGR-5/6/7 test predicted zero fuel particle failures in Capsules 1, 3, and 4. Fuel particle failures were predicted in two of the compacts in Capsule 2 and one particle failure is predicted in each one of the compacts in Capsule 5. All compacts that exhibited fuel particle failures predicted by PARFUME were caused by localized stress concentrations in the silicon carbide (SiC) layer caused by cracking in the inner pyrolytic (IPyC) layer. In addition, shrinkage of the buffer and IPyC layer during irradiation resulted in formation of a buffer-IPyC gap. Compacts with a lower irradiation temperature and fluence experienced the smallest buffer-IPyC gap formation. Conversely, higher irradiated temperature compacts with a high fluence experienced the largest buffer-IPyC gap formation. Compact 3-6-3 experienced the largest buffer IPyC gap formation of just under 21.7 µm. The release fraction of fission products silver (Ag), cesium (Cs), and strontium (Sr) vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 3, reaching up to 59.5% for the TRISO fuel particles (compact 3-6-3). The release fraction of the other two fission products, Cs and Sr, are much smaller. A maximum Cs release fraction of 1.1% occurred in compact 3-4-3 and 4.4% for Sr in compact 3-6-3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary design of a helium cryogenic system for SAND detector at LBNF-DUNE near site

The Long-Baseline Neutrino Facility (LBNF) is providing a helium cryogenic system to support the superconducting solenoid magnet of the System for on-Axis Neutrino Detection (SAND) for the Deep Underground Neutrino Experiment (DUNE) Near Site at Fermilab in Batavia, IL. The design started in 2020 and construction is set to begin in the mid 2020‘s.The helium cryogenic system primarily consists of a helium refrigerator system, distribution valve boxes, vacuum-jacketed helium and nitrogen transfer lines, warm gaseous helium transfer system, instruments and control system, and gaseous helium storage tanks. It is designed to provide supercritical helium at around 3 bara and 5 K with expansion from 3 to 1.2 bara in the SAND cryostat and 70K forced cold gas helium to cool the thermal shields of the SAND cryostat. The SAND superconductive magnet is indirectly cooled through a liquid helium thermosiphon cycle. A pair of 3 kA leads is cooled by the gas helium vaporized from the liquid helium reservoir in the cryostat turret. The helium system will share the liquid nitrogen tank and liquid nitrogen phase separator with the Near Site Liquid Argon system. The helium recycle compressor system, GHe tanks and LN2 tank will be located on the Surface. The cryogenic facilities including refrigerator cold box, valve boxes and LN2 phase separator will be located on the shaft cryo-mezzanine in the underground cavern. The shaft connecting surface and cavern is more than 60 meter deep. The helium vacuum-jacketed transfer line between the cold box and the SAND magnet is more than 50 meter long. This paper presents the preliminary design of the helium cryogenic system including the design scheme, process flow diagram, heat load estimates, layout plan and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The neutron number probability distribution in coupled lumped assemblies

Here, the validity of the gamma distribution in describing the neutron number probability distribution function for both isolated and coupled multiplying assemblies when constrained to reproduce the true mean and variance is investigated in lumped geometry by numerical comparison with kinetic Monte Carlo simulations. The mean and variance are obtained from numerical solution of moment equations constructed from the relevant forward Master equation with assembly coupling coefficients obtained from a view factor method. Numerical results for a two-group, two coupled assemblies model, with static and dynamic reactivity insertion, show that except for subcritical assemblies, the gamma distribution well-approximates the number distribution. Differences in the fast and thermal neutron population shapes are explained in terms of effective source strengths due to downscatter and coupling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the onset of nucleate boiling in liquid xenon

We report the first precision measurement of the superheat temperature required for bubble nucleation in liquid xenon of Δ T wall,ONB = (16.9±0.5) K and Δ T wall,ONB = (19.2 +0.4 -1.1 ) K at pressures of P = (0.98±0.02) bar and P = (1.32 +0.05 -0.01 ) bar, respectively. Both are measured at a subcooled bulk fluid temperature of ~ 162 K. A dedicated liquid xenon setup is used to measure the temperature at which bubble nucleation first appears on the flat surface of a resistor. The associated average heat flux at the surface of the resistor is determined using fluid dynamics simulations. Future experiments can use these experimental results to determine the likelihood of boiling in liquid xenon and to design effective thermal sinks that prevent bubble nucleation.

47 OTHER INSTRUMENTATION↗

Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

36 MATERIALS SCIENCE↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Infrared MBE-Grown HgCdTe Focal Plane Arrays and Cameras After High Energy Neutron Irradiation

HgCdTe is one of the most important materials for the fabrication of infrared detectors and focal plane arrays (FPAs) deployed in environments where high-energy particles, such as protons and neutrons, are present. We designed and fabricated HgCdTe-based FPAs that can be used in high neutron radiation environments and we measured their characteristics. The influence of the radiation on the infrared FPAs and cameras is investigated. HgCdTe material and devices are capable of maintaining high performances in a high energy neutron irradiation environment. For MWIR FPA directly facing a $2.59 × 10^8$ n/cm$^2$ s neutron flux beam (with the highest energy 66 MeV) for 1 h, the noise equivalent differential temperature (NEDT) increased ~8 times after irradiation. However, NEDT decreased to 33 mK (compared to the original value of 21 mK) after one warming-up (to room temperature) and cooling-down cycle. The NEDT for the MWIR FPAs mounted parallel to the beam did not degrade (16 mK and 28 mK before irradiation, changed to 18 mK and 26 mK after irradiation, respectively).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intersubband Transitions in Lead Halide Perovskite-Based Quantum Wells for Mid-Infrared Detectors

Due to their excellent optical and electrical properties as well as versatile growth and fabrication processes, lead halide perovskites have been widely considered as promising candidates for green energy and applications related to optoelectronics. Here, we investigate their potential applications at infrared wavelengths by modeling the intersubband transitions in perovskite-based quantum well systems. Both single-well and double-well structures are studied, and their energy levels as well as the corresponding wave functions and intersubband transition energies are calculated by solving the one-dimensional Schrödinger equations. Via adjustment of the quantum well and barrier thicknesses, the intersubband transition energies can be tuned to cover a broad infrared wavelength range. We also find that the lead halide perovskite-based quantum wells possess high absorption coefficients. In conclusion, the widely tunable transition energies and high absorption coefficients of the perovskite-based quantum well systems, combined with their unique material and electrical properties, may enable an alternative material system for infrared photodetector applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BEYONDPLANCK XIV. Polarized foreground emission between 30 and 70 GHz

We constrain polarized foreground emission between 30 and 70 GHz with the Planck Low Frequency Instrument (LFI) and WMAP data within the global Bayesian BeyondPlanck framework. We combine for the first time full-resolution Planck LFI time-ordered data with low-resolution WMAP sky maps at 33, 40 and 61 GHz. Spectral parameters are fit with a likelihood defined at the native resolution of each frequency channel. This analysis represents the first implementation of true multi-resolution component separation applied to CMB observations for both amplitude and spectral energy distribution (SED) parameters. For synchrotron emission, we approximate the SED as a power-law in frequency and find that the low signal-to-noise ratio of the current data strongly limits the number of free parameters that may be robustly constrained. We partition the sky into four large disjoint regions (High Latitude; Galactic Spur; Galactic Plane; and Galactic Center), each associated with its own power-law index. We find that the High Latitude region is prior-dominated, while the Galactic Center region is contaminated by residual instrumental systematics. The two remaining regions appear to be signal-dominated, and for these we derive spectral indices of $β$ S Spur = -3.17 ± 0.06 and $β$ S Plane = -3.03 ± 0.07, in good agreement with previous results. For thermal dust emission we assume a modified blackbody model and we fit a single power-law index across the full sky. We find $β$ d = 1.64 ± 0.03, which is slightly steeper than reported from Planck HFI data, but still statistically consistent at the 2σ confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase-field predictions of the influence of cooling rates during AM on the Evolution of Microstructures in Nickel-Based Single Crystal Superalloys

Additive manufacturing of single crystals made of Ni-based superalloys offers major cost savings for gas turbine engines with the inclusion of internal cooling channels. However, the lack of understanding of the effect of transient thermal conditions on solidification grain structure during additive manufacturing hinders the potential for process control to maintain the single crystal quality. The use of high-fidelity simulations through high performance computing to predict the evolution of the solidification microstructure will enhance the abilities to tailor the microstructures through process optimization. Phase field simulations are used to determine the effect local thermal conditions and defects on the stability of the solidification morphology, specifically with respect to the onset of columnar-to-equiaxed transition that results in the loss of the single crystal. The results are expected to be instrumental for developing future surrogate models to speed up the integration of design and manufacturing of turbine blades under the harsh in-service conditions.

36 MATERIALS SCIENCE↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Dark matter in X-rays: revised XMM-Newton limits and new constraints from eROSITA

We investigate two classes of dark matter (DM) candidates, sub-GeV particles and primordial black holes (PBHs), that can inject low-energy electrons and positrons into the Milky Way and leave observable signatures in the X-ray sky. In the case of sub-GeV DM, annihilation or decay into e + e - contributes to the diffuse sea of cosmic-ray (CR) leptons, which can generate bremsstrahlung and inverse Compton (IC) emission on Galactic photon fields, producing a broad spectrum from X-rays to γ-rays detectable by instruments such as eROSITA and XMM-Newton. For PBHs with masses below ∼10 17 g, Hawking evaporation similarly yields low-energy e ± , leading to comparable diffuse emission. Using the first data release from eROSITA and incorporating up-to-date CR propagation and diffusion parameters, we derive new constraints on both scenarios. For sub-GeV DM, we exclude thermally averaged annihilation cross sections in the range ∼ 10 -27 –10 -25 cm 3 /s and decay lifetimes of ∼ 10 24 –10 25 s for masses between 1 MeV and 1 GeV, with eROSITA outperforming previous X-ray constraints below ∼ 30 MeV. For asteroid-mass PBHs, we set new bounds on the DM fraction based on their Hawking-induced emission. Finally, we revisit previous constraints in 10.1088/1475-7516/2023/07/026JCAP 07 (2023) 026 and consequently 10.3847/1538-4357/ad41e0Astrophys. J. 968 (2024) 46 derived from XMM-Newton, finding that they were approximately four orders of magnitude too stringent due to the use of the instrument's geometric solid angle rather than its exposure-weighted solid angle. Upon using the exposure-weighted solid angle, we show that the revised XMM-Newton limits are slightly weaker than those from eROSITA.

X-rays↗

Physical origins of the varying performance and unusual transport behaviors among thermoelectric A Mg 2 Sb 2 materials ( A = Ca, Sr, Sm, Yb, and Mg)

Contrary to the similar thermoelectric performance among both AZn 2 Sb 2 and AMg 2 Bi 2 compounds, their isostructural counterparts, AMg 2 Sb 2 , can exhibit thermoelectric figure of merit values that vary by orders of magnitude with different A elements. Here, we reveal physical origins accounting for the significantly differing performance among AMg 2 Sb 2 -based compounds (A = Ca, Sr, Sm, Yb, and Mg) through comprehensive analyses, where it is shown that the dispar- ities in performance at the macroscale essentially originate from the widely varying activation energies that equal amounts of dopant can induce. Meanwhile, a few unusual transport behaviors regarding electrical conductivity, carrier concentration, or lattice thermal con- ductivity among these compounds have been identified, and we also present their rationales in depth. Furthermore, this mechanism-focused study can not only promote further understanding of the complex transport behaviors in condensed matter but be instrumental in rationally tun- ing the physical properties of materials as well.

36 MATERIALS SCIENCE↗

Design of a 140 GHz waveguide notch filter for millimeter-wave receiver module protection in fusion plasma diagnostics

A carefully designed waveguide-based millimeter-wave notch filter, operating at 140 GHz, safeguards plasma diagnostic instruments from gyrotron leakage. Here, utilizing cylindrical cavity resonators with aperture coupling, the filter efficiently resonates 140 GHz wave-power into the TE 11p mode, optimizing various geometrical parameters for practical fabrication and high-yield production. Thorough thermal analysis ensures its ability to handle power. The filter achieves outstanding performance with over 90 dB rejection at 140 GHz while providing low insertion loss over the passband (110–138 GHz), which is ideally suited for system-on-chip approach F-band diagnostic system applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ARENA Test Bed – A Versatile Resource for I&C Development and Validation

The Accelerated and Real-time Experimental Nodal Assessment (ARENA) Test Bed at the Pacific Northwest National Laboratory (PNNL) is a versatile resource for development and validation of instrumentation and control (I&C) technologies. This capability was created to facilitate in-situ testing of nuclear electrical cables in various simulated operational environments. Using cable trays, a control box, and selected test components, low voltage cables can be staged to experience local adverse environments such as elevated temperature and water immersion. Cable condition can be continuously monitored over time to track the effect of local stresses using nondestructive assessment tools. A heads-up display (ARENA TV) plots key data in real-time for users. The ARENA Test Bed has recently been used to evaluate the potential for spread spectrum time domain reflectometry (SSTDR) to monitor thermal aging of a portion of live cable powering a three-phase motor. The arrangement provided the opportunity to directly compare the performance of the novel online SSTDR method with offline results from the more standard frequency domain reflectometry (FDR) method. The ability of SSTDR and FDR to identify the presence of water in immersed shielded and unshielded cables and to detect ground faults was also assessed. A digital twin is being developed to track and predict FDR signals from a thermally aging conceptual cable region to compare with measured signals from the ARENA physical counterpart. The test bed concept addresses an important need in nuclear I&C monitoring tool development. New tools and techniques can be developed in the test bed and validated versus known methods and physical measurements. Digital twins and machine learning engines can be populated with measured data in a controlled environment that would not be readily available in the actual nuclear power plant. Proposed monitoring strategies can be confirmed for effectiveness through objective evaluation. It is anticipated that the PNNL ARENA Test Bed will be a valuable resource in advancing nuclear plant instrumentation.

nuclear electrical cables, ARENA Test Bed, conditi↗

Physics-based compact modeling of electro-thermal memristors: Negative differential resistance, local activity, and non-local dynamical bifurcations

Leon Chua's Local Activity theory quantitatively relates the compact model of an isolated nonlinear circuit element, such as a memristor, to its potential for desired dynamical behaviors when externally coupled to passive elements in a circuit. However, the theory's use has often been limited to potentially unphysical toy models and analyses of small-signal linear circuits containing pseudo-elements (resistors, capacitors, and inductors), which provide little insight into required physical, material, and device properties. Furthermore, the Local Activity concept relies on a local analysis and must be complemented by examining dynamical behavior far away from the steady-states of a circuit. In this work, we review and study a class of generic and extended one-dimensional electro-thermal memristors (i.e., temperature is the sole state variable), re-framing the analysis in terms of physically motivated definitions and visualizations to derive intuitive compact models and simulate their dynamical behavior in terms of experimentally measurable properties, such as electrical and thermal conductance and capacitance and their derivatives with respect to voltage and temperature. Within this unified framework, we connect steady-state phenomena, such as negative differential resistance, and dynamical behaviors, such as instability, oscillations, and bifurcations, through a set of dimensionless nonlinearity parameters. In particular, we reveal that the reactance associated with electro-thermal memristors is the result of a phase shift between oscillating current and voltage induced by the dynamical delay and coupling between the electrical and thermal variables. We thus, demonstrate both the utility and limitations of local analyses to understand non-local dynamical behavior. Critically for future experimentation, the analyses show that external coupling of a memristor to impedances within modern sourcing and measurement instruments can dominate the response of the total circuit, making it impossible to characterize the response of an uncoupled circuit element for which a compact model is desired. However, these effects can be minimized by proper understanding of the Local Activity theory to design and utilize purpose-built instruments.

Brown, Timothy D. (ORCID:0000000347068355)↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigations into the Ternary NaF-KF-UF4 Salt System – Phase A

A knowledge gap exists in the data and understanding of fresh fuel salt and irradiated multicomponent fuel salt systems thermophysical properties. Quantifying these properties is necessary for the design and construction of test reactors, as well as the licensing of future commercial molten-salt reactors. To facilitate thermal property determination on a proposed fuel salt composition for Seaborg Technologies, several samples containing depleted uranium tetrafluoride (UF4), sodium fluoride (NaF), and potassium fluoride (KF) were blended, and a melt temperature analysis was performed. From the melting temperature analysis, it was determined that sample Seaborg-7, a ternary salt composition of 26.4UF4-24.7KF-48.9NaF (mol%), was very near a ternary eutectic point. Therefore, thermal properties such as melting temperature, salt stability, density, heat capacity, thermal diffusivity, and viscosity were experimentally determined on the Seaborg-7 salt. These measurements document the baseline properties of fresh fuel salt as a function of temperature, where future experiments on irradiated fuel salt will provide a holistic perspective on the change of thermophysical properties during reactor operations. Several precision instruments were used to collect property data, and instrument calibrations and data collection were performed and documented in a standardized and reproducible manner with meticulous detail. This process ensured that the measurement procedures and resulting data can readily be duplicated elsewhere. The Seaborg-7 salt was shown to be stable at temperatures up to 900°C, as no mass change was observed upon repeated heating and cooling. The peak melting temperature was determined to be 547°C (557°C endset). The enthalpy of fusion (??H?_fus^o) was determined to be 167.5 ± 2.7 J/g while the enthalpy of crystallization (??H?_c^o) was determined to be -147.8 ± 13.3 J/g. In addition to the eutectic melting peak, upon heating, several pre eutectic peaks were observed, occurring at 470°C (onset) and 499°C (peak). Specific heat capacity measurements showed a slightly increasing trend with respect to temperature in the solid phase, while the liquid-specific heat capacity showed a somewhat flat trend with an average value of 106.1 ± 1.24 J/mol·K between 600 to 800°C. Three independent trials using the Seaborg-7 salt determined the density to be ?(T) = 4.908 – 0.000363·T(°C), validated between 32 to 200°C, and ?(T) = 4.808 – 0.00113·T(°C), validated between ~575 to 850°C. Thermal diffusivity was determined for the liquid state and is represented by the linear equation y = 0.1581 + 0.000207·T(°C) between 550 to 850°C. The viscosity was determined from 600 to 800°C and is represented by the exponential fit equation, ? (mPa·s) = 736.58e^(-0.006·T(°C)). This report documents the conclusion of fuel salt thermophysical property measurements for the Seaborg SPP, Phase A project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗