Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Evaluation of dose recalculation vs dose deformation in a commercial platform for deformable image registration with a computational phantom

Deformable image registration (DIR) is an important tool for mapping both dose and contours of a new set of planning images when recurrent, that is, adaptive radiotherapy, or further treatment, that is, re-treatment, is required. The aim of this study was to evaluate the need for plan recalculation in deformed anatomies and to develop a reliable workflow for validating the DIR algorithm to be applied to dose warping such as dose accumulation (DA) for adaptive radiation therapy, and dose summation (DS) in the case of re-treatment. A set of 3 computational phantoms was developed to validate the application of B-Spline-based registrations for dose mapping among the various computed tomography image data sets. Two different versions were defined for each phantom to simulate clinical needs: adaptive radiotherapy and re-treatment; a DIR was performed to obtain a displacement vector field (DVF) for dose applications. Comparison of calculated and deformed doses was carried out by means of known markers inside the virtual phantoms. The differences were evaluated using a 3% dose index as acceptance criteria. A paired Wilcoxon signed-rank test was carried out to test the statistical significance of differences within the markers. Significant differences were only observed for the deformed dose in the DA test; no significant differences were observed for recalculated dose values in the DA and DS tests. The dose index is in accordance with these results. The warping dose process obtained by registering various sets of images was validated; a recalculation approach seems to be more accurate for DA purposes and image-guided adaptive radiation therapy (IGART) applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating User Errors and Temporal Trends in Marine Fish Communities Using 360-Degree Underwater Photography

The use of environmental DNA (eDNA) sampling has been proposed as a complementary method to monitor fish species in marine environments, offering a non-invasive and potentially more efficient approach to marine species observations. eDNA monitoring could be especially useful in and around sites targeted for marine energy generation as these regions need regular monitoring that would be impractical with traditional techniques. Before we can fully rely upon eDNA, we must first verify its accuracy against other proven methods, such as the use of underwater photography. In this study, I deployed a 360-degree camera in the tidal channel of Sequim Bay once a month during several hours overlapping slack tide. I investigated how having multiple people identify and count fish on underwater images could affect the overall results. Using chi square tests in R, I compared my fish identifications and counts to those made by another intern on the same images recorded in August. I found significant differences in the number of species identified and the total individual counts between the two different datasets. I also tested the statistical differences in both Shannon diversity and Pielou evenness indices between the August, September, and November camera deployments using a Hutcheson t-test. Only one significant difference was found in the Shannon index comparisons, and none were found between the Pielou evenness comparisons. These findings show that if multiple identifiers are used to process underwater images, quality control checks must be made to reduce the potential for error. This also points toward the possibility to leverage more advanced image analysis processes, such as automated image analysis software. The findings from this study also show that the dynamics of marine fish communities can vary over a few months; however, further analysis is needed to determine the extent of the seasonal changes in Sequim Bay.

59 BASIC BIOLOGICAL SCIENCES↗

Hypothesis testing of scientific Monte Carlo calculations

The steadily increasing size of scientific Monte Carlo simulations and the desire for robust, correct, and reproducible results necessitates rigorous testing procedures for scientific simulations in order to detect numerical problems and programming bugs. However, the testing paradigms developed for deterministic algorithms have proven to be ill suited for stochastic algorithms. In this paper we demonstrate explicitly how the technique of statistical hypothesis testing, which is in wide use in other fields of science, can be used to devise automatic and reliable tests for Monte Carlo methods, and we show that these tests are able to detect some of the common problems encountered in stochastic scientific simulations. We argue that hypothesis testing should become part of the standard testing toolkit for scientific simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CMB low multipole alignments across WMAP and Planck data releases

ABSTRACT The first observations of the cosmic microwave background (CMB) from NASA's Wilkinson Microwave Anisotropy Probe (WMAP) led to finding ‘alignment’ anomalies not expected from fluctuations in the isotropic cosmological model. We study the data of all 8 full-sky public releases since then to test for anomalous alignments and shapes of the first 60 multipoles, i.e. over the range $2\le l \le 61$. We use rotationally invariant and covariant statistics to test isotropy of all subsequent WMAP data releases, along with those from the ESA’s Planck mission. Anomalous alignments among the multipoles $l=1, 2, 3$ are very consistent and robust. More alignments are detected, some of them new, while significance is diluted by the large range of the search. Power entropy, a measure of the randomness of the multipoles, is consistently anomalous at about $2\sigma$ level or better across all data releases. It appears that the CMB is not as random as the cosmological principle predicts on large angular scales.

Patel, Sanjeet Kumar↗

Letter Report: LAW Simulant Development for Cast Stone Screening Test

More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is being constructed to treat the wastes and immobilize them in a glass waste form. The WTP includes a pretreatment facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the nonradioactive chemicals. The HLW will be converted to glass in the HLW vitrification facility for ultimate disposal at an offsite federal repository. At least a portion (~35%) of the LAW will be converted to glass in the LAW vitrification facility and will be disposed of onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize the wastes destined for each facility. However, a second facility will be needed for the expected volume of additional LAW requiring immobilization. A cementitious waste form known as Cast Stone is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with waste acceptance criteria for the IDF disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. Further, the waste form must be tested to provide the technical basis for understanding the long term performance of the waste form in the IDF disposal environment. These waste form performance data are needed to support risk assessment and performance assessment (PA) analyses of the long-term environmental impact of the waste disposal in the IDF. A testing program was developed in fiscal year (FY) 2012 describing in some detail the work needed to develop and qualify Cast Stone as a waste form for the solidification of Hanford LAW (Westsik et al. 2012). Included within Westsik et al. (2012) is a section on the near-term needs to address Tri-Party Agreement Milestone M-062-40ZZ. The objectives of the testing program to be conducted in FY 2013 and FY 2014 are to: • Determine an acceptable formulation for the LAW Cast Stone waste form. • Evaluate sources of dry materials for preparing the LAW Cast Stone. • Demonstrate the robustness of the Cast Stone waste form for a range of LAW compositions. • Demonstrate the robustness of the formulation for variability in the Cast Stone process. • Provide Cast Stone contaminant release data for PA and risk assessment evaluations. The first step in determining an acceptable formulation for the LAW Cast Stone waste form is to conduct screening tests to examine expected ranges in pretreated LAW composition, waste stream concentrations, dry-materials sources, and mix ratios of waste feed to dry blend. A statistically designed test matrix will be used to evaluate the effects of these key parameters on the properties of the Cast Stone as it is initially prepared and after curing. The second phase of testing will focus on selection of a baseline Cast Stone formulation for LAW and demonstrating that Cast Stone can meet expected waste form requirements for disposal in the IDF. It is expected that this testing will use the results of the screening tests to define a smaller suite of tests to refine the composition of the baseline Cast Stone formulation (e.g. waste concentration, water to dry mix ratio, waste loading).

Russell, Renee L.↗

A Statistical Perspective on Highly Accelerated Testing

Highly accelerated life testing has been heavily promoted at Sandia (and elsewhere) as a means to rapidly identify product weaknesses caused by flaws in the product's design or manufacturing process. During product development, a small number of units are forced to fail at high stress. The failed units are then examined to determine the root causes of failure. The identification of the root causes of product failures exposed by highly accelerated life testing can instigate changes to the product's design and/or manufacturing process that result in a product with increased reliability. It is widely viewed that this qualitative use of highly accelerated life testing (often associated with the acronym HALT) can be useful. However, highly accelerated life testing has also been proposed as a quantitative means for "demonstrating" the reliability of a product where unreliability is associated with loss of margin via an identified and dominating failure mechanism. It is assumed that the dominant failure mechanism can be accelerated by changing the level of a stress factor that is assumed to be related to the dominant failure mode. In extreme cases, a minimal number of units (often from a pre-production lot) are subjected to a single highly accelerated stress relative to normal use. If no (or, sufficiently few) units fail at this high stress level, some might claim that a certain level of reliability has been demonstrated (relative to normal use conditions). Underlying this claim are assumptions regarding the level of knowledge associated with the relationship between the stress level and the probability of failure. The primary purpose of this document is to discuss (from a statistical perspective) the efficacy of using accelerated life testing protocols (and, in particular, "highly accelerated" protocols) to make quantitative inferences concerning the performance of a product (e.g., reliability) when in fact there is lack-of-knowledge and uncertainty concerning the assumed relationship between the stress level and performance. In addition, this document contains recommendations for conducting more informative accelerated tests.

42 ENGINEERING↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Supplemental Immobilization of Hanford Low-Activity Waste: Cast Stone Augmented Formulation Matrix Tests

More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in Washington State. The HLW will be vitrified in the HLW facility for ultimate disposal at an offsite federal repository. A portion (~35%) of the LAW will be vitrified in the LAW vitrification facility for disposal onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize all of the wastes destined for those facilities. However, a second facility will be needed for the expected volume of LAW requiring immobilization. Cast Stone, a cementitious waste form, is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with the waste acceptance criteria for the disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. A testing program was developed in fiscal year (FY) 2012 describing in detail the work needed to develop and qualify Cast Stone as a waste form for the solidification of Hanford LAW. A statistically designed test matrix was used to evaluate the effects of key parameters on the properties of the Cast Stone as it is initially prepared and after curing. For the processing properties, the water-to-dry-blend mix ratio was the most significant parameter in affecting the range of values observed for each property. The single shell tank (SST) Blend simulant also showed differences in measured properties compared to the other three simulants tested. A review of the testing matrix and results indicated that an additional set of tests would be beneficial to improve the understanding of the impacts noted in the Screening Matrix tests. A set of Cast Stone formulations were devised to augment the original screening test matrix and focus on the range of the test conditions. Fly ash and blast furnace slag were limited to either northwest or southeast and the salt solutions were narrowed to the Average and the SST Blend at the 7.8M Na concentration. To fill in the matrix, a mix ratio of 0.5 was added. In addition, two admixtures, Xypex Admix C-500 and Rheomac SF100 (silica fume), were added as an additional dry material binder in select compositions. As in the Screening Matrix, both fresh and cured properties were evaluated for the formulations. In this study, properties that were influenced by the W/DM ratio in the Screening Matrix; flow diameter, plastic viscosity, density, and compressive strength, showed consistent behavior with respect to W/DM. The leach index for highly soluble components, sodium and nitrate, were not influenced by changes in formulation or the admixtures. The leach index for both iodine and Tc-99 show an influence from the addition of the admixture, Xypex Admix C-500. Additional testing should be performed to further evaluate the influence of Xypex Admix C-500 on the leach index over a range of admixture concentrations, Cast Stone formulations, and curing and storage conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Parameter-masked Mock Data Challenge for Beyond-two-point Galaxy Clustering Statistics

The past few years have seen the emergence of a wide array of novel techniques for analyzing high-precision data from upcoming galaxy surveys, which aim to extend the statistical analysis of galaxy clustering data beyond the linear regime and the canonical two-point (2pt) statistics. We test and benchmark some of these new techniques in a community data challenge named “Beyond-2pt,” initiated during the Aspen 2022 Summer Program “Large-Scale Structure Cosmology beyond 2-Point Statistics,” whose first round of results we present here. The challenge data set consists of high-precision mock galaxy catalogs for clustering in real space, in redshift space, and on a light cone. Participants in the challenge have developed end-to-end pipelines to analyze mock catalogs and extract unknown (“masked”) cosmological parameters of the underlying ΛCDM models with their methods. The methods represented are density-split clustering, nearest neighbor statistics, BACCO power spectrum emulator, void statistics, LEFTfield field-level inference using effective field theory (EFT), and joint power spectrum and bispectrum analyses using both EFT and simulation-based inference. In this work, we review the results of the challenge, focusing on problems solved, lessons learned, and future research needed to perfect the emerging beyond-2pt approaches. The unbiased parameter recovery demonstrated in this challenge by multiple statistics and the associated modeling and inference frameworks supports the credibility of cosmology constraints from these methods. The challenge data set is publicly available, and we welcome future submissions from methods that are not yet represented.

Krause, Elisabeth [Univ. of Arizona, Tucson, AZ (U↗

Relationship Between Neurocognitive Function and Quality of Life After Whole-Brain Radiotherapy in Patients With Brain Metastasis

Purpose: To examine the relationship between neurocognitive function (NCF) and quality of life (QOL) in patients with brain metastases after whole-brain radiotherapy. Patients and Methods: A total of 208 patients from the whole-brain radiotherapy arm of a Phase III trial (PCI-P120-9801), who underwent regular NCF and QOL (ADL [activities of daily living] and FACT-Br [Functional Assessment of Cancer Therapy-Brain-specific]) testing, were analyzed. Spearman's rank correlation was calculated between NCF and QOL, using each patient's own data, at each time point. To test the hypothesis that NCF declines before QOL changes, the predictive effect of NCF from previous visits on QOL was studied with a linear mixed-effects model. Neurocognitive function or QOL deterioration was defined relative to each patient's own baseline. Lead or lag time, defined as NCF deterioration before or after the date of QOL decline, respectively, was computed. Results: At baseline, all NCF tests showed statistically significant correlations with ADL, which became stronger at 4 months. A similar observation was made with FACT-Br. Neurocognitive function scores from previous visits predicted ADL (p < 0.05 for seven of eight tests) or FACT-Br. Scores on all eight NCF tests deteriorated before ADL decline (net lead time 9-153 days); and scores on six of eight NCF tests deteriorated before FACT-Br (net lead time 9-82 days). Conclusions: Neurocognitive function and QOL are correlated. Neurocognitive function scores from previous visits are predictive of QOL. Neurocognitive function deterioration precedes QOL decline. The sequential association between NCF and QOL decline suggests that delaying NCF deterioration is a worthwhile treatment goal in brain metastases patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PROBABILITY BASED CORROSION CONTROL FOR HIGH LEVEL WASTE TANKS: INTERIM REPORT

Controls on the solution chemistry (minimum nitrite and hydroxide concentrations) are in place to prevent the initiation and propagation of pitting and stress corrosion cracking in high level waste (HLW) tanks. These controls are based upon a series of experiments performed on carbon steel coupons in simulated waste solutions. An experimental program was undertaken to investigate reducing the minimum molar nitrite concentration required to confidently inhibit pitting. A statistical basis to quantify the probability of pitting for the tank wall, when exposed to various dilute solutions, is being developed. Electrochemical and coupon testing are being performed within the framework of the statistical test matrix to determine the minimum necessary inhibitor concentrations and develop a quantitative model to predict pitting propensity. A subset of the original statistical test matrix was used to develop an applied understanding of the corrosion response of the carbon steel in the various environments. The interim results suggest that there exists some critical nitrite concentration that sufficiently inhibits against localized corrosion mechanisms due to nitrates/chlorides/sulfates, beyond which further nitrite additions are unnecessary. The combination of visual observation and the cyclic potentiodynamic polarization scans indicate the potential for significant inhibitor reductions without consequence specifically at nitrate concentrations near 1 M. The complete data sets will be used to determine the statistical basis to confidently inhibit against pitting using nitrite inhibition with the current pH controls. Once complete, a revised chemistry control program will be devised based upon the probability of pitting specifically for dilute solutions which will allow for tank specific chemistry control implementation.

36 MATERIALS SCIENCE↗

Trends in extreme temperature over Nigeria from percentile‐based threshold indices

ABSTRACT This study analyses spatial and temporal trends in extreme temperature indices over Nigeria. The percentile indices were calculated from newly homogenized daily minimum and maximum temperature data for the period 1971–2012 for 21 stations in Nigeria. Indices describing the characteristics of hot extremes and cold extremes are calculated with the RClimDex software. The annual and seasonal trends in these indices are obtained using the ordinary least square fit and the statistical significance tested using the R‐based modified Mann–Kendall test. We examine characteristics of these indices for the entire country and separately for the three geographical zones in Nigeria: Guinea, Savanna, and Sahel. The spatial and temporal patterns of trends in the indices indicate that Nigeria has experienced statistically significant increase in the frequency of hot extreme and decrease in cold extreme events. Although majority of the stations have significant trends in warm days and warm nights, the annual trend is greatest in warm nights. In addition, the rate of warming in minimum temperature (‘warm nights’) is stronger in June, July, August ( JJA ) and September, October, November ( SON ) compare with December, January, February ( DJF ) and March, April, May ( MAM ). As for the trends in cold days and cold nights, the trends in cold nights are larger than for cold days at both the annual and seasonal scales. The regional analysis indicates that trends in warm nights and cold nights are most pronounced in Guinea and Sahel regions.

Abatan, Abayomi A.↗

AGR-3/4 Data Qualification Report for ATR Cycles 151A, 151B, 152A, 152B, 154A, and 154B

This data report provides the qualification status of Advanced Gas Reactor-3/4 (AGR-3/4) fuel irradiation experimental data from Advanced Test Reactor (ATR) Cycles 151A, 151B, 152A, 152B, 154A, and 154B, as recorded in the Nuclear Data Management and Analysis System (NDMAS). Of these cycles, ATR Cycle 152A is a low power cycle that occurred when the ATR core was briefly at low power. The irradiation data are not used for physics and thermal calculation, but the qualification status of these cycle data is still covered in this report. On the other hand, during ATR Cycles 153A (unplanned Outage cycle) and 153B (Power Axial Locator Mechanism [PALM] cycle), the AGR-3/4 was pulled out from the ATR core and stored in the canal to avoid being overheated. Therefore, qualification of the AGR-3/4 irradiation data from these 2 cycles was excluded in this report. By the end of ATR Cycle 154B, AGR-3/4 was irradiated for a total of 264.1 effective full power days. The AGR-3/4 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates, pressure, and moisture content), and Fission Product Monitoring System (FPMS) data (release rates and release-to-birth rate ratios [R/Bs]) for each of the twelve capsules in the AGR-3/4 experiment. The final data qualification status for these data streams is determined by a Data Review Committee (DRC) composed of AGR technical leads, Sitewide Quality Assurance (QA), and NDMAS analysts. The DRC convened on February 12, 2014, reviewed the data acquisition process, and considered whether the data met the requirements for data collection as specified in QA-approved Very High Temperature Reactor (VHTR) Technology Development Office (TDO) data collection plans. The DRC also examined the results of NDMAS data testing and statistical analyses, and confirmed the qualification status of the data as given in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA

Purpose: A novel patient-specific intensity modulated radiation therapy (IMRT) QA system, 3DVH software and mapcheck 2, purports to be able to use diode array-measured beam doses and the patient's DICOM RT plan, structure set, and dose files to predict the delivered 3D dose distribution in the patient for comparison to the treatment planning system (TPS) calculated doses. In this study, the composite dose to an ion chamber and film in phantom predicted by the 3DVH and mapcheck 2 system is compared to the actual measured chamber and film doses. If validated in this context, then 3DVH can be used to perform an equivalent dose analysis as that obtained with film dosimetry and ion chamber-based composite IMRT QA. This is important for those losing their ability to perform film dosimetry for true composite IMRT QA and provides a measure of confidence in the accuracy of 3DVH 3D dose calculations which may replace phantom-based IMRT QA. Methods: The dosimetric results from 15 consecutive patient-specific IMRT QA tests performed by composite field irradiation of ion chamber and EDR2 film in a solid water phantom were compared to the predicted doses for those virtual detectors based on the calculated 3D dose by the 3DVH software using mapcheck 2 measured doses of each beam within each plan. For each of the 15 cases, immediately after performing the ion chamber plus film measurements, the mapcheck 2 was used to measure the dose for each beam of the plan. The dose to the volume of the virtual ion chamber and the dose distribution in the plane of the virtual film calculated by the 3DVH software was extracted. The ratio of the measured to 3DVH or eclipse-predicted ion chamber doses was calculated. The same plane in the phantom measured using film and calculated with eclipse was exported from 3DVH and the 2D gamma metric was used to compare the relationship between the film doses and the eclipse or 3DVH predicted planar doses. Also, the 3D gamma value was calculated in the 3DVH software which compares the eclipse dose to the 3DVH predicted dose distribution. For the 2D and 3D gamma metrics, 2% dose and 2 mm distance to agreement (DTA) were used. In addition, a simple dose difference was performed using either a 2% or 3% dose difference tolerance. Results: The mean ratio {+-} standard deviation of the measured vs 3DVH or vs eclipse-predicted dose to the ion chamber was 1.013 {+-} 0.015 and 1.003 {+-} 0.012, respectively. For 3DVH vs eclipse, the mean percentage of pixels failing the 3D gamma metric was 1.2% {+-} 1.4% while the failure rate for the 2D gamma metric was 1.1% {+-} 0.9%. When either 3DVH or eclipse was compared to EDR2 film, the gamma failure rate was 2.3% {+-} 2.0% and 1.6% {+-} 1.7%, respectively. Mean dose difference failures were 9%-27% {+-} 5%-15% for 2 or 3% dose difference tolerances, depending on the combination of systems tested. No statistically significant differences were found for any of the planar dosimetric comparisons. Conclusions: 3DVH + mapcheck 2 predicts the same absolute dose, the percent of pixels failing the gamma metric, and the percent of pixels failing 2% or 3% dose difference tolerance tests as one would have obtained had one made measurements in solid water phantom using an ion chamber and coronal film instead of a diode array. This is also a necessary although not sufficient condition for validation of the accuracy of 3DVH predictions of the 3D dose using beam-by-beam measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Percent-Level Test of Isotropic Expansion Using Type Ia Supernovae

We propose and implement a novel, robust, and nonparametric test of statistical isotropy of the expansion of the Universe and apply it to around 1000 type Ia supernovae from the Pantheon sample. We calculate the angular clustering of supernova magnitude residuals and compare it to the noise expected under the isotropic assumption. We also test for systematic effects and demonstrate that their effects are negligible or are already accounted for in our procedure. Here, we express our constraints as an upper limit on the rms spatial variation in the Hubble parameter at late times. For the sky smoothed with a Gaussian with FWHM = 60°, less than 1% rms spatial variation in the Hubble parameter is allowed at 99.7% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical Analysis of Low Flow Filter Efficiency Testing Results for Nuclear Material Storage Container Filters

Air filters designed to contain plutonium particulates while allowing hydrogen gas to escape are used in a variety of low flow rate applications in the nuclear industry. Examples include nuclear material storage containers, glove box bag-out bags and waste drums. Filter efficiency testing is essential to ensure filter performance, and yet the low testing flow rates present some challenges because the testing flow rates can be 5 to 6 orders of magnitude lower than those used to test large HEP A filter systems used in facility ventilation systems. Statistical analysis of low flow filter efficiency test results on nuclear material storage container filters has proven to be essential to ensure that the testing processes, test equipment, and filters meet the design requirements. This poster will describe the testing apparatus used to test nuclear material storage container filters and the use of statistical methods to analyze low flow filter efficiency test results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bayesian optimized collection strategies for fatigue strength testing

Abstract A statistical framework is presented enabling optimal sampling and analysis of constant life fatigue data. Protocols using Bayesian maximum entropy sampling are built based on conventional staircase and stress step methods, reducing the requirement of prior knowledge for data collection. The Bayesian Staircase method shows improved parameter estimation efficiency, and the Bayesian Stress Step method shows equal accuracy to the standard method at larger step size allowing experimentalists to lessen concerns of loading history. Statistical methods for determining model suitability are shown, highlighting the influence of protocol. Experimental validation is performed, showing the applicability of the methods in laboratory testing.

36 MATERIALS SCIENCE↗