Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Test of nuclear decay rate variation due to an antineutrino flux

Unexplained variations of the decay rate parameter for weak interaction decays such as β ± decay, electron capture, as well as strong interaction α decay have been reported. Because these variations have been presented by a number of groups, at various locations, using various types of detectors, different isotopes, and over extended periods of time, some researchers have interpreted the source of these variations as not from ambient environmental factors such as temperature, pressure, and humidity but via an unexplained fundamental interaction. The state of decay rate parameter variations experiments is reviewed, and the reported results are placed into a common comparable context by defining a phenomenological cross section. After that we make decay parameter measurements as a function of time at the level of 10 -5 in the presences of an antineutrino flux with an on-off cycle time of ≈ 30 days. This level of precision requires a detailed understanding of both systematic and statistical errors; otherwise, systematic errors in the measurement may mimic the decay events of fundamental interactions. The experiment searched for variation of the $^{54}_{25}$Mn, e - capture decay rate parameter and $^{137}_{55}$Cs, β - decay rate parameter both to a level of precision of 1 part in ≈10 5 by comparing the difference between the decay rate in the presence of an antineutrino flux ≈ 3 x 10 12 $\bar{ν}$ cm -2 s -1 and no flux measurements. The experiment was located 6.53 m from the reactor core of the High Flux Isotope Reactor at the Oak Ridge National Laboratory. Two weak interaction decays, one via electron capture and the other via β - decay, were selected because the final state and the time reverse state each contain a neutrino and antineutrino, covering arguments that the antineutrino flux may interact differently or not at all in one of the cases. The $\gamma$ spectra from both decays were collected and analyzed independently. The measured variation in the decay rate parameters are found to be δλ/λ =(0.034 ± 1.38) x10 -5 for $^{54}_{25}$Mn and δλ/λ =(0.67±1.56) x10 -5 for $^{137}_{55}$Cs. These results are consistent with no measurable decay rate parameter variation due to an antineutrino flux, yielding a 68% confidence level upper limit sensitivity for $^{54}_{25}$Mn δλ/λ ≤ 1.31 x 10 -5 or σ ≤ 1.29 x10 -25 cm 2 in cross section and for $^{137}_{55}$Cs δλ/λ ≤ 2.23 x 10 -5 or σ ≤ 5.69 x10 -27 cm 2 . The cross-section upper limit obtained in these null or no observable effect measurements are ≈ 10 4 times more sensitive than past experiments reporting positive results in 54 Mn and 137 Cs. . .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimation of the Mass Absorption Cross Section of the Organic Carbon Component of Aerosols in the Mexico City Metropolitan Area

Data taken from the MCMA-2003 and the 2006 MILAGRO field campaigns are used to examine the absorption of solar radiation by the organic component of aerosols. Using irradiance data from an Multi-Filter Rotating Shadowband Radiometer (MFRSR) and an actinic flux spectroradiometer, we find aerosol single scattering albedo, ω - 0,λ, as a function of wavelength, λ. We find that in near-UV spectral range (defined here as 250 nm to 400 nm) ω - 0,λ is much lower compared to ω - 0,λ at 500 nm suggesting enhanced absorption in the near-UV range. Absorption by elemental carbon, dust, or gas cannot account for this enhanced absorption leaving only the organic part of the aerosol to account for it. We use data from a surface deployed Aerodyne Aerosol Mass Spectrometer (AMS) along with the inferred ω - 0,λ to estimate the Mass Absorption Cross-section (MAC) for the organic carbon. We find that the MAC is about 10.5 m2/g at 300 nm and falls close to zero at about 500 nm; values that are roughly consistent with other estimates of organic carbon MAC. These MAC values can be considered as “radiatively correct” because when used in radiative transfer calculations the calculated irradiances match the measured irradiances at the wavelengths considered here. The uncertainties of individual estimates are quite large, ±30% at 300 nm for the random error, and even larger for a worst-case estimate of the systematic error, ±80%. The error represents the unusual circumstance where no error cancellation is permitted, and is unlikely ever to be realized.

54 ENVIRONMENTAL SCIENCES↗

ON THE NATURE OF SMALL PLANETS AROUND THE COOLEST KEPLER STARS

We constrain the densities of Earth- to Neptune-size planets around very cool (T{sub e} = 3660-4660 K) Kepler stars by comparing 1202 Keck/HIRES radial velocity measurements of 150 nearby stars to a model based on Kepler candidate planet radii and a power-law mass-radius relation. Our analysis is based on the presumption that the planet populations around the two sets of stars are the same. The model can reproduce the observed distribution of radial velocity variation over a range of parameter values, but, for the expected level of Doppler systematic error, the highest Kolmogorov-Smirnov probabilities occur for a power-law index {alpha} Almost-Equal-To 4, indicating that rocky-metal planets dominate the planet population in this size range. A single population of gas-rich, low-density planets with {alpha} = 2 is ruled out unless our Doppler errors are {>=}5 m s{sup -1}, i.e., much larger than expected based on observations and stellar chromospheric emission. If small planets are a mix of {gamma} rocky planets ({alpha} = 3.85) and 1 - {gamma} gas-rich planets ({alpha} = 2), then {gamma} > 0.5 unless Doppler errors are {>=}4 m s{sup -1}. Our comparison also suggests that Kepler's detection efficiency relative to ideal calculations is less than unity. One possible source of incompleteness is target stars that are misclassified subgiants or giants, for which the transits of small planets would be impossible to detect. Our results are robust to systematic effects, and plausible errors in the estimated radii of Kepler stars have only moderate impact.

79 ASTRONOMY AND ASTROPHYSICS↗

Redshift evolution and covariances for joint lensing and clustering studies with DESI Y1

ABSTRACT Galaxy–galaxy lensing (GGL) and clustering measurements from the Dark Energy Spectroscopic Instrument Year 1 (DESI Y1) data set promise to yield unprecedented combined-probe tests of cosmology and the galaxy–halo connection. In such analyses, it is essential to identify and characterize all relevant statistical and systematic errors. We forecast the covariances of DESI Y1 GGL + clustering measurements and the systematic bias due to redshift evolution in the lens samples. Focusing on the projected clustering and GGL correlations, we compute a Gaussian analytical covariance, using a suite of N-body and lognormal simulations to characterize the effect of the survey footprint. Using the DESI one percent survey data, we measure the evolution of galaxy bias parameters for the DESI luminous red galaxy (LRG) and bright galaxy survey (BGS) samples. We find mild evolution in the LRGs in $0.4 < z < 0.8$, subdominant to the expected statistical errors. For BGS, we find less evolution for brighter absolute magnitude cuts, at the cost of reduced sample size. We find that for a redshift bin width $\Delta z = 0.1$, evolution effects on DESI Y1 GGL is negligible across all scales, all fiducial selection cuts, all fiducial redshift bins. Galaxy clustering is more sensitive to evolution due to the bias squared scaling. Nevertheless the redshift evolution effect is insignificant for clustering above the 1-halo scale of $0.1h^{-1}$ Mpc. For studies that wish to reliably access smaller scales, additional treatment of redshift evolution is likely needed. This study serves as a reference for GGL and clustering studies using the DESI Y1 sample.

79 ASTRONOMY AND ASTROPHYSICS↗

MINOS results from the NuMI beam

We present an updated measurement of {nu}{sub {mu}} disappearance in the NuMI neutrino beam using MINOS detectors. This preliminary result is based on 2.5x10{sup 20} protons on target. We observe 563 charged-current {nu}{sub {mu}} events in the Far Detector, where we expect 738{+-}30 in the absence of neutrino oscillations. The observed deficit is consistent with oscillation hypothesis. The best fit to oscillation parameters yields {delta}m{sub 23}{sup 2} = 2.38{sub -0.16}{sup +0.20}x10{sup -3} eV{sup 2} and sin{sup 2} 2{theta}{sub 23} = 1.00{sub -0.08} with errors quoted at the 68% confidence level. The uncertainties include both statistical and systematic errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact And Robust Laser Impulse Measurement Device, With Ultrashort Pulse Laser Ablation Results

An impulse measurement device and analysis package was conceived, designed, constructed, tested, and demonstrated to be capable of: measuring nanoNewton-seconds to milliNewton-seconds of impulse due to laser-ablation; being transported as carry-on baggage; set-up and tear-down times of less than an hour; target exchange times of less than two minutes (targets can be ablated at multiple positions for thousands of shots); measurements in air and in vacuum; error of just a few percent; repeatability over a wide range of potential systematic error sources; and time between measurements, including ring-down and analysis, of less than 30 seconds. The instrument consists of a cantilever (i.e. leaf spring), whose time-dependent displacement/oscillation is measured and analyzed to determine the impulse imparted by a laser pulse to a target. These shapes are readily/commercially available, and any target material can be used, provided it can be fashioned in the form of a cantilever, or as a coating/film/tape, suitable for mounting on a cantilever of known geometry. The instrument was calibrated both statically and dynamically, and measurements were performed on brass, steel, and Aluminum, using laser pulses of {approx}7 ns, {approx}500 ps, and {approx}500 fs. The results agree well with those published in the literature, with surface effects, atmosphere, and pre-/post-pulses demonstrating interesting effects and indicating areas for further study. These parameters should be carefully controlled and held constant during a series of measurements. The impulse imparted by ablation due to laser filaments in air was also explored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of absolute hadronic branching fractions of D mesons and e{sup +}e{sup -}{yields}DD cross sections at the {psi}(3770)

Using 281 pb{sup -1} of e{sup +}e{sup -} collisions recorded at the {psi}(3770) resonance with the CLEO-c detector at CESR (Cornell Electron Storage Ring), we determine absolute hadronic branching fractions of charged and neutral D mesons using a double tag technique. Among measurements for three D{sup 0} and six D{sup +} modes, we obtain reference branching fractions B(D{sup 0}{yields}K{sup -}{pi}{sup +})=(3.891{+-}0.035{+-}0.059{+-}0.035)% and B(D{sup +}{yields}K{sup -}{pi}{sup +}{pi}{sup +})=(9.14{+-}0.10{+-}0.16{+-}0.07)%, where the first uncertainty is statistical, the second is all systematic errors other than final-state radiation (FSR), and the third is the systematic uncertainty due to FSR. We include FSR in these branching fractions by allowing for additional unobserved photons in the final state. Using an independent determination of the integrated luminosity, we also extract the cross sections {sigma}(e{sup +}e{sup -}{yields}D{sup 0}D{sup 0})=(3.66{+-}0.03{+-}0.06) nb and {sigma}(e{sup +}e{sup -}{yields}D{sup +}D{sup -})=(2.91{+-}0.03{+-}0.05) nb at a center-of-mass energy, E{sub cm}=3774{+-}1 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charm quark system at the physical point of 2+1 flavor lattice QCD

We investigate the charm quark system using the relativistic heavy quark action on 2+1 flavor PACS-CS configurations previously generated on 32{sup 3}x64 lattice. The dynamical up, down, and strange quark masses are set to the physical values by using the technique of reweighting to shift the quark-hopping parameters from the values employed in the configuration generation. At the physical point, the lattice spacing equals a{sup -1}=2.194(10) GeV and the spatial extent L=2.88(1) fm. The charm quark mass is determined by the spin-averaged mass of the 1S charmonium state, from which we obtain m{sub charm}{sup MS}({mu}=m{sub charm}{sup MS})=1.260(1)(6)(35) GeV, where the errors are due to our statistics, scale determination and renormalization factor. An additional systematic error from the heavy quark is of order {alpha}{sub s}{sup 2}f(m{sub Q}a)(a{Lambda}{sub QCD}), f(m{sub Q}a)(a{Lambda}{sub QCD}){sup 2}, which are estimated to be a percent level if the factor f(m{sub Q}a) analytic in m{sub Q}a is of order unity. Our results for the charmed and charmed-strange meson decay constants are f{sub D}=226(6)(1)(5) MeV, f{sub D{sub s}}=257(2)(1)(5) MeV, again up to the heavy quark errors of order {alpha}{sub s}{sup 2}f(m{sub Q}a)(a{Lambda}{sub QCD}), f(m{sub Q}a)(a{Lambda}{sub QCD}){sup 2}. Combined with the CLEO values for the leptonic decay widths, these values yield |V{sub cd}|=0.205(6)(1)(5)(9), |V{sub cs}|=1.00(1)(1)(3)(3), where the last error is because of the experimental uncertainty of the decay widths.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LAMOST DR1: Stellar Parameters and Chemical Abundances with SP-Ace

We present a new analysis of the LAMOST DR1 survey spectral database performed with the code SP-Ace, which provides the derived stellar parameters T{sub eff}, logg, [Fe/H], and [α/H] for 1,097,231 stellar objects. We tested the reliability of our results by comparing them to reference results from high spectral resolution surveys. The expected errors can be summarized as ∼120 K in T{sub eff}, ∼0.2 in logg, ∼0.15 dex in [Fe/H], and ∼0.1 dex in [α/Fe] for spectra with S/N > 40, with some differences between dwarf and giant stars. SP-Ace provides error estimations consistent with the discrepancies observed between derived and reference parameters. Some systematic errors are identified and discussed. The resulting catalog is publicly available at the LAMOST and CDS websites.

79 ASTRONOMY AND ASTROPHYSICS↗

Charm quark system at the physical point of 2+1 flavor lattice QCD

We investigate the charm quark system using the relativistic heavy quark action on 2+1 flavor PACS-CS configurations previously generated on 32{sup 3} x 64 lattice. The dynamical up, down, and strange quark masses are set to the physical values by using the technique of reweighting to shift the quark-hopping parameters from the values employed in the configuration generation. At the physical point, the lattice spacing equals a{sup -1} = 2.194(10) GeV and the spatial extent L = 2.88(1) fm. The charm quark mass is determined by the spin-averaged mass of the 1S charmonium state, from which we obtain m{sub charm}{sup M{bar S}} ({mu} = m{sub charm}{sup M{bar S}}) = 1.260(1)(6)(35) GeV, where the errors are due to our statistics, scale determination and renormalization factor. An additional systematic error from the heavy quark is of order {alpha}{sub s}{sup 2}f(m{sub Q}a)(a{Lambda}{sub QCD}), f(m{sub Q}a)(a{Lambda}{sub QCD}){sup 2}, which are estimated to be a percent level if the factor f(m{sub Q}a) analytic in m{sub Q}a is of order unity. Our results for the charmed and charmed-strange meson decay constants are f{sub D} = 226(6)(1)(5) MeV, f{sub D}{sub s} = 257(2)(1)(5) MeV, again up to the heavy quark errors of order {alpha}{sub s}{sup 2}f(m{sub Q}a)(a{Lambda}{sub QCD}), f(m{sub Q}a)(a{Lambda}{sub QCD}){sup 2}. Combined with the CLEO values for the leptonic decay widths, these values yield |V{sub cd}| = 0.205(6)(1)(5)(9), |V{sub cs}| = 1.00(1)(1)(3)(3), where the last error is because of the experimental uncertainty of the decay widths.

2+1↗

Dielectric-barrier-discharge plasma-assisted hydrogen diffusion flame. Part 1: Temperature, oxygen, and fuel measurements by one-dimensional fs/ps rotational CARS imaging

One-dimensional hybrid fs/ps CARS imaging provides single-laser-shot measurements of temperature, oxygen, and hydrogen in a plasma-assisted hydrogen diffusion flame. The coaxial dielectric-barrier-discharge burner collapses the Re ~50 hydrogen diffusion flame to within ~5 mm of the burner surface at an applied AC potential of 8.75 kV at 18 kHz, coinciding nicely with the full spatial extent of the 1D CARS measurements. Translating the burner through the measurement volume allowed for measurements at numerous radial locations in increments of 1 mm with a resolution of 140 µm × 30 µm × 600 µm, sufficient to resolve spatial gradients in this unsteady flame. Longer probe delays, required for improved dynamic range in regions of high temperature fluctuations, proved difficult to model as a result of a nontrivial decay in the O 2 Raman coherence arising from complexities associated with the triplet ground electronic state of the O 2 molecule. Oxygen linewidths were treated empirically using the observed O 2 coherence decay in spectra acquired from the product gases of lean, near-adiabatic H 2 /air flames stabilized on a Hencken flat-flame burner. While still leading to errors up to 10% at worst, the empirically determined Raman linewidth factors eliminated any systematic error in the O 2 /N 2 measurements with probe delay. Temperature measurements in the Hencken Burner flames proved to be insensitive to probe pulse delay, providing robust thermometry. Here, demonstration of this technique in both the canonical Hencken burner flames and a new DBD burner validates its effectiveness in producing multiple spatially resolved measurements in combustion environments. Measurements in the DBD burner revealed an unsteady, counterflow flattened flame structure near the fuel orifice which became unsteady as the reaction zone curves towards the surface for larger radial positions. Lastly, fluctuations in the fuel concentration were largest at the source, as the large, plasma-generated, unsteady external toroidal vortex that dominates the transport in this flame provides enhanced ventilation of the flame surface in close proximity to the fuel tube.

42 ENGINEERING↗

Elastic nucleon-pion scattering at m π = 200 MeV from lattice QCD

Elastic nucleon-pion scattering amplitudes are computed using lattice QCD on a single ensemble of gauge field configurations with N f = 2 + 1 dynamical quark flavors and m π = 200 MeV. The s-wave scattering lengths with both total isospins I = 1/2 and I = 3/2 are inferred from the finite-volume spectrum below the inelastic threshold together with the I = 3/2 p-wave containing the Δ(1232) resonance. The amplitudes are well-described by the effective range expansion with parameters constrained by fits to the finite-volume energy levels, enabling a determination of the I = 3/2 scattering length with statistical errors below 5%, while the I = 1/2 scattering length is somewhat less precisely evaluated. Systematic errors due to excited states and the influence of higher partial waves are controlled, providing a step toward future computations down to physical light quark masses with multiple lattice spacings and volumes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE SEVENTH DATA RELEASE OF THE SLOAN DIGITAL SKY SURVEY

This paper describes the Seventh Data Release of the Sloan Digital Sky Survey (SDSS), marking the completion of the original goals of the SDSS and the end of the phase known as SDSS-II. It includes 11,663 deg{sup 2} of imaging data, with most of the {approx}2000 deg{sup 2} increment over the previous data release lying in regions of low Galactic latitude. The catalog contains five-band photometry for 357 million distinct objects. The survey also includes repeat photometry on a 120 deg. long, 2.{sup 0}5 wide stripe along the celestial equator in the Southern Galactic Cap, with some regions covered by as many as 90 individual imaging runs. We include a co-addition of the best of these data, going roughly 2 mag fainter than the main survey over 250 deg{sup 2}. The survey has completed spectroscopy over 9380 deg{sup 2}; the spectroscopy is now complete over a large contiguous area of the Northern Galactic Cap, closing the gap that was present in previous data releases. There are over 1.6 million spectra in total, including 930,000 galaxies, 120,000 quasars, and 460,000 stars. The data release includes improved stellar photometry at low Galactic latitude. The astrometry has all been recalibrated with the second version of the USNO CCD Astrograph Catalog, reducing the rms statistical errors at the bright end to 45 milliarcseconds per coordinate. We further quantify a systematic error in bright galaxy photometry due to poor sky determination; this problem is less severe than previously reported for the majority of galaxies. Finally, we describe a series of improvements to the spectroscopic reductions, including better flat fielding and improved wavelength calibration at the blue end, better processing of objects with extremely strong narrow emission lines, and an improved determination of stellar metallicities.

79 ASTRONOMY AND ASTROPHYSICS↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

TU-C-BRE-07: Quantifying the Clinical Impact of VMAT Delivery Errors Relative to Prior Patients’ Plans and Adjusted for Anatomical Differences

Purpose: There is increased interest in the Radiation Oncology Physics community regarding sensitivity of pre-treatment IMRT/VMAT QA to delivery errors. Consequently, tools mapping pre-treatment QA to the patient DVH have been developed. However, the quantity of plan degradation that is acceptable remains uncertain. Using DVHs adapted from prior patients’ plans, we developed a technique to determine the magnitude of various delivery errors required to degrade a treatment plan to outside the clinically accepted range. Methods: DVHs for relevant organs at risk were adapted from a population of prior patients’ plans using a machine learning algorithm to establish the clinically acceptable DVH range specific to the patient’s anatomy. We applied this technique to six low-risk prostate cancer patients treated with single-arc VMAT and compared error-induced DVH changes to the adapted DVHs to determine the magnitude of error required to push the plan outside of the acceptable range. The procedure follows: (1) Errors (systematic ' random shift of MLCs, gantry-MLC desynchronization, dose rate fluctuations, etc.) were simulated and degraded DVHs calculated using the Varian Eclipse TPS. (2) Adapted DVHs and acceptable ranges for DVHs were established. (3) Relevant dosimetric indices and corresponding acceptable ranges were calculated from the DVHs. Key indices included NTCP (Lyman-Kutcher-Burman Model) and QUANTEC’s dose-volume Objectives: s of V75Gy≤0.15 for the rectum and V75Gy≤0.25 for the bladder. Results: Degradations to the clinical plan became “unacceptable” for 19±29mm and 1.9±2.0mm systematic outward shifts of a single leaf and leaf bank, respectively. All other simulated errors fell within the acceptable range. Conclusion: Utilizing machine learning and prior patients’ plans one can predict a clinically acceptable range of DVH degradation for a specific patient. Comparing error-induced DVH degradations to this range, it is shown that single-arc VMAT plans for low-risk prostate are relatively insensitive to many potential delivery errors.

60 APPLIED LIFE SCIENCES↗

Effects of Setup Errors and Shape Changes on Breast Radiotherapy

Purpose: The purpose of the present study was to quantify the robustness of the dose distributions from three whole-breast radiotherapy (RT) techniques involving different levels of intensity modulation against whole patient setup inaccuracies and breast shape changes. Methods and Materials: For 19 patients (one computed tomography scan and five cone beam computed tomography scans each), three treatment plans were made (wedge, simple intensity-modulated RT [IMRT], and full IMRT). For each treatment plan, four dose distributions were calculated. The first dose distribution was the original plan. The other three included the effects of patient setup errors (rigid displacement of the bony anatomy) or breast errors (e.g., rotations and shape changes of the breast with respect to the bony anatomy), or both, and were obtained through deformable image registration and dose accumulation. Subsequently, the effects of the plan type and error sources on target volume coverage, mean lung dose, and excess dose were determined. Results: Systematic errors of 1-2 mm and random errors of 2-3 mm (standard deviation) were observed for both patient- and breast-related errors. Planning techniques involving glancing fields (wedge and simple IMRT) were primarily affected by patient errors ({approx}6% loss of coverage near the dorsal field edge and {approx}2% near the skin). In contrast, plan deterioration due to breast errors was primarily observed in planning techniques without glancing fields (full IMRT, {approx}2% loss of coverage near the dorsal field edge and {approx}4% near the skin). Conclusion: The influences of patient and breast errors on the dose distributions are comparable in magnitude for whole breast RT plans, including glancing open fields, rendering simple IMRT the preferred technique. Dose distributions from planning techniques without glancing open fields were more seriously affected by shape changes of the breast, demanding specific attention in partial breast planning techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sub-divertor fuel isotopic content detection limit for JET and its impact on ICRF core heating and DTE2 operation

The ability to detect and control fuel isotopic content down to a 1% concentration level is greatly important for the upcoming JET DTE2 campaign, as well as its associated TT and DD phases. A reduction of H minority concentration even from 2% down to 1% is shown in this paper to have significant impact on the effectiveness of ion cyclotron range of frequencies core heating, while the ability to maintain T or D concentration at or below 1% is critical to limiting fusion neutron generation in the DD and TT phases, correspondingly. The sub-divertor measurement of (global) isotopic concentration, based on Penning-activated optical spectroscopy, can deliver minimally this 1% detection for DTE2 as long as light collection from the Penning emission can be optimized and gradual window transmission deterioration can be minimized. Here, this is simulated with a statistical analysis developed to understand the uncertainty sources in the JET DTE1 data, as well as to guide the optimization of an upgraded, fuel-isotopic content (and helium-ash concentration) gas analysis system for the JET divertor in preparation for DTE2. While this random error can be reduced to allow measurement substantially below 1% concentration, analysis also shows a systematic error of up to 1% understood to be due to plasma–surface interactions in the Penning excitation, suggesting that 1% may still be the low-end limit for the sub-divertor measurement, unless a Penning-source conditioning approach is also developed.

fusion fuel isotopic content↗

DETECTION OF GAMMA-RAY POLARIZATION IN PROMPT EMISSION OF GRB 100826A

We report the polarization measurement in prompt {gamma}-ray emission of GRB 100826A with the Gamma-Ray Burst Polarimeter on board the small solar-power-sail demonstrator IKAROS. We detected the firm change of polarization angle (PA) during the prompt emission with 99.9% (3.5{sigma}) confidence level, and the average polarization degree ({Pi}) of 27% {+-} 11% with 99.4% (2.9{sigma}) confidence level. Here the quoted errors are given at 1{sigma} confidence level for the two parameters of interest. The systematic errors have been carefully included in this analysis, unlike other previous reports. Such a high {Pi} can be obtained in several emission models of gamma-ray bursts (GRBs), including synchrotron and photospheric models. However, it is difficult to explain the observed significant change of PA within the framework of axisymmetric jet as considered in many theoretical works. The non-axisymmetric (e.g., patchy) structures of the magnetic fields and/or brightness inside the relativistic jet are therefore required within the observable angular scale of {approx}{Gamma}{sup -1}. Our observation strongly indicates that the polarization measurement is a powerful tool to constrain the GRB production mechanism, and more theoretical works are needed to discuss the data in more detail.

79 ASTRONOMY AND ASTROPHYSICS↗