Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

The behavior of beams of relativistic nonthermal electrons under the influence of collisions and synchrotron losses

For many astrophysical situations, such as in solar flares or cosmic gamma-ray bursts, continuum gamma rays with energies up to hundreds of MeV were observed, and can be interpreted to be due to bremsstrahlung radiation by relativistic electrons. The region of acceleration for these particles is not necessarily the same as the region in which the radiation is produced, and the effects of the transport of the electrons must be included in the general problem. Hence it is necessary to solve the kinetic equation for relativistic electrons, including all the interactions and loss mechanisms relevant at such energies. The resulting kinetic equation for non-thermal electrons, including the effects of Coulomb collisions and losses due to synchrotron emission, was solved analytically in some simple limiting cases, and numerically for the general cases including constant and varying background plasma density and magnetic field. New approximate analytic solutions are presented for collision dominated cases, for small pitch angles and all energies, synchrotron dominated cases, both steady-state and time dependent, for all pitch angles and energies, and for cases when both synchrotron and collisional energy losses are important, but for relativistic electrons. These analytic solutions are compared to the full numerical results in the proper limits. These results will be useful for calculation of spectra and angular distribution of the radiation (X rays, gamma-rays, and microwaves) emitted via synchrotron or bremsstrahlung processes by the electrons. These properties and their relevance to observations will be observed in subsequent papers.

Mctiernan, James M.↗

The metrology of spherical shells using synchrotron x ray microtomography

With recent advances in solid state imaging technology and the increasing availability of synchrotron x-ray radiation sources, synchrotron x-ray microtomography is emerging as a nondestructive technique for the evaluation of the structure and composition of small specimens with spatial resolution in the micron range. Synchrotron radiation offers the following advantages over conventional x-ray sources: high brightness, continuous emission which is tunable over a large energy range, faster data collection rates, and a highly collimated beam of large cross section permitting the illumination of large specimens. Synchrotron x-ray microtomography enables the structure of individual spheres to be evaluated in order to reveal the concentricity and sphericity of the internal void and the uniformity of the shell wall in the case of high quality spherical shells for Sandia National Laboratories' Inertial Confinement Fusion project.

Hmelo, Anthony B.↗

A Study of Short-Term Variations in Jupiter's Synchrotron Emission

Earth-based observations of the flux density and polarization of Jupiter's microwave emission provide useful data to test and constrain computational models of synchrotron radio emission from the inner regions of the Jovian magnetosphere. Stimulated by the sudden brightening of the synchrotron emission caused by the impacts of comet Shoemaker-Levy 9 in 1994, the observational techniques of the NASA-JPL Jupiter Patrol were modified to search for other short-term variations unrelated to the SL-9 event. The characteristics of the improved data base are described and the results of the search for variability on timescales of 5 to 100 days are reported. The first results of Jupiter observations from the Goldstone-Apple Valley Radio Telescope (GAVRT) project are reported and included in the data base. GAVRT is a new project in science education that engages middle- and high school students in science research. The paper also includes new observations of Jupiter's rotational beamed emission, commonly known as the "beaming curve", that describes the observed flux density as a function of System III longitude. The shape of the "beaming curve" is known to change with the parameter D(sub E), the declination of the earth relative to Jupiter's rotational equator. While the history of Jupiter's beaming curve exhibits remarkable stability and repeatability as a function of D(sub E), there may be evidence for short term departures from the nominal curves. Data supporting this tentative conclusion are presented. Preliminary results of a study comparing the observations and computer simulations of the synchrotron beaming curve will also be presented and discussed (see companion paper, "Modeling Jupiter's Synchrotron Emission", by Bolton et. al.). The research reported in this paper was performed by the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration.

Klein, M.J.↗

Synchrotron X-Ray Diffraction Analysis of Meteorites in Thin Section: Preliminary Results

X-ray diffraction is the pre-eminent technique for mineral identification and structure determination, but is difficult to apply to grains in thin section, the standard meteorite preparation. Bright focused X-ray beams from synchrotrons have been used extensively in mineralogy and have been applied to extraterrestrial particles. The intensity and small spot size achievable in synchrotron X-ray beams makes them useful for study of materials in thin sections. Here, we describe Synchrotron X-ray Diffraction (SXRD) in thin section as done at the National Synchrotron Light Source, and cite examples of its value for studies of meteorites in thin section.

Treiman, A. H.↗

Synchrotron Vacuum Ultraviolet Light and Soft X-Ray Radiation Effects on Aluminized Teflon FEP Investigated

Since the Hubble Space Telescope (HST) was deployed in low Earth orbit in April 1990, two servicing missions have been conducted to upgrade its scientific capabilities. Minor cracking of second-surface metalized Teflon FEP (DuPont; fluorinated ethylene propylene) surfaces from multilayer insulation (MLI) was first observed upon close examination of samples with high solar exposure retrieved during the first servicing mission, which was conducted 3.6 years after deployment. During the second HST servicing mission, 6.8 years after deployment, astronaut observations and photographic documentation revealed significant cracks in the Teflon FEP layer of the MLI on both the solar- and anti-solar-facing surfaces of the telescope. NASA Goddard Space Flight Center directed the efforts of the Hubble Space Telescope MLI Failure Review Board, whose goals included identifying the low-Earth-orbit environmental constituent(s) responsible for the cracking and embrittling of Teflon FEP which was observed during the second servicing mission. The NASA Lewis Research Center provided significant support to this effort. Because soft x-ray radiation from solar flares had been considered as a possible cause for the degradation of the mechanical properties of Teflon FEP (ref. 1), the effects of soft xray radiation and vacuum ultraviolet light on Teflon FEP were investigated. In this Lewisled effort, samples of Teflon FEP with a 100-nm layer of vapor-deposited aluminum (VDA) on the backside were exposed to synchrotron radiation of various vacuum ultraviolet and soft x-ray wavelengths between 18 nm (69 eV) and 0.65 nm (1900 eV). Synchrotron radiation exposures were conducted using the National Synchrotron Light Source at Brookhaven National Laboratory. Samples of FEP/VDA were exposed with the FEP surface facing the synchrotron beam. Doses and fluences were compared with those estimated for the 20-yr Hubble Space Telescope mission.

Dever, Joyce A.↗

Neutrino Emission in the Hadronic Synchrotron Mirror Model: The "Orphan" Flare from 1ES 1959+650

A challenge to standard leptonic synchrotron self-Compton (SSC) models is the so-called orphan TeV flares, i.e., enhanced very high energy (VHE) gamma-ray emission without any contemporaneous X-ray flaring activity, that have recently been observed in TeV blazars (e.g., 1ES 1959+650). In order to explain the orphan TeV flare of 1 ES 1959+650 observed in 2002 June, the so-called hadronic synchrotron mirror model has been developed. Here relativistic protons are proposed to exist in the jet and interact with reflected electron synchrotron radiation of the precursor SSC flare. If the reflector is located in the cloud region, time shifts of several days are possible between the precursor and the orphan flare. The external photons, blue-shifted in the comoving jet frame, are able to excite the Delta(1232) resonance when interacting with protons of Lorentz factors gamma(sub p) approx. 10(exp 3)-10(exp 4). The decay products of this resonance include charged pions, which, on decay, give rise to neutrino production during the orphan flare. In this paper we calculate the expected neutrino emission for the 2002 June 4 orphan TeV flare of 1ES 1959+650. We compare our results with the recent observations of AMANDA-II of a neutrino event in spatial and temporal coincidence with the orphan flare of this blazar. We find that the expected neutrino signal from the hadronic synchrotron mirror model is insufficient to explain the claimed neutrino signal from the direction of 1ES 1959+650.

Reimer, A.↗

Gadolinium Deposition in Nephrogenic Systemic Fibrosis: An Examination of Tissue using Synchrotron X-ray Fluorescence Spectroscopy

Nephrogenic systemic fibrosis is a fibrosing disorder associated with gadolinium (Gd)-based contrast agents dosed during renal insufficiency. In two patients, Gd deposition in tissue affected by nephrogenic systemic fibrosis was quantified using inductively coupled plasma mass spectrometry. The presence of Gd was confirmed and mapped using synchrotron x-ray fluorescence spectroscopy. Affected skin and soft tissue from the lower extremity demonstrated 89 and 209 ppm ({micro}g/g, dry weight, formalin fixed) in cases 1 and 2, respectively. In case 2, the same skin and soft tissue was retested after paraffin embedding, with the fat content removed by xylene washes, and this resulted in a measured value of 189 ppm ({micro}g/g, dry weight, paraffin embedded). Synchrotron x-ray fluorescence spectroscopy confirmed Gd in the affected tissue of both cases, and provided high-sensitivity and high-resolution spatial mapping of Gd deposition. A gradient of Gd deposition in tissue correlated with fibrosis and cellularity. Gd deposited in periadnexal locations within the skin, including hair and eccrine ducts, where it colocalized to areas of high calcium and zinc content. Because of the difficulty in obtaining synchrotron x-ray fluorescence spectroscopy scans, tissue from only two patients were mapped. A single control with kidney disease and gadolinium-based contrast agent exposure did not contain Gd. Gd content on a gravimetric basis was impacted by processing that removed fat and altered the dry weight of the specimens. Gradients of Gd deposition in tissue corresponded to fibrosis and cellularity. Adnexal deposition of Gd correlated with areas of high calcium and zinc content.

59 BASIC BIOLOGICAL SCIENCES↗

Microbeam, timing and signal-resolved studies of nuclear materials with synchrotron X-ray sources

The development of ultra-brilliant synchrotron X-ray sources enables characterization methods that are particularly important for nuclear materials. Here we discuss emerging synchrotron methods with unprecedented signal-to-noise, spatial and time resolution. Microprobe methods are discussed that extend virtually any X-ray characterization measurement to ultra-small sample volumes. This ability is critical to resolve heterogeneities in nuclear materials and for studies on volumes with vastly lower activity than are needed for traditional X-ray characterization. Specific methods discussed include microdiffraction for the characterization of local crystal structure and micro-spectroscopy techniques that allow for characterization of elemental distributions with sensitivity for daughter products, oxidation states and diffusion through buffer layers. Opportunities are also discussed that exploit the high brilliance and pulsed nature of synchrotron radiation to reduce backgrounds from sample radiation and to study materials dynamics.

36 MATERIALS SCIENCE↗

Synchrotron Radiation Circular Dichroism (SRCD) Spectroscopy: An Emerging Method in Structural Biology for Examining Protein Conformations and Protein Interactions

Circular dichroism (CD) spectroscopy is a well-established technique in structural biology. The use of synchrotron radiation as an intense light source for these measurements extends the applications possible using lab-based instruments. In recent years, there has been a major growth in synchrotron radiation circular dichroism (SRCD) beamlines worldwide, including ones at the NSLS, ISA, SRS, HiSOR, BSRF, NSRRC, SOLEIL, Diamond, TERAS, BESSYII, and ANKA synchrotrons. Through the coordinated efforts of beamline scientists and users at these sites, important proof-of-principle studies have been done enabling the method to be developed for novel and productive studies on biological systems. This paper describes the characteristics of SRCD beamlines and some of the new types of applications that have been undertaken using these beamlines.

43 PARTICLE ACCELERATORS↗

Determination of Endosperm Protein Secondary Structure in Hard Wheat Breeding Lines using Synchrotron Infrared Microspectroscopy

One molecular aspect of mature hard wheat protein quality for breadmaking is the relative amount of endosperm protein in the a-helix form compared with that in other secondary structure forms including {beta}-sheet. Modeling of a-helix and {beta}-sheet absorption bands that contribute to the amide I band at 1650 cm-1 was applied to more than 1500 spectra in this study. The microscopic view of wheat endosperm is dominated by many large starch granules with protein in between. The spectrum produced from in situ microspectroscopy of this mixture is dominated by carbohydrate bands from the large starch granules that fill up the field. The high spatial resolution achievable with synchrotron infrared microspectroscopy enables revealing good in situ spectra of the protein located interstitially. Synchrotron infrared microspectroscopic mapping of 4 {mu}m thick frozen sections of endosperm in the subaleurone region provides spectra from a large number of pixels. Pixels with protein-dominated spectra are sorted out from among adjacent pixels to minimize the starch absorption and scattering contributions. Subsequent data treatment to extract information from the amide I band requires a high signal to noise ratio. Although spectral interference of the carbohydrate band on the amide band is not a problem, the scattering produced by the large starch granules diminishes the signal to noise ratio throughout the spectrum. High density mapping was done on beamlines U2B and U10B at the National Synchrotron Light Source at Brookhaven National Laboratory, Upton, NY. Mapping with a single masked spot size of 5.5 {mu}m diameter or confocal 5 {mu}m x 5 {mu}m spot size, respectively, on the two beamlines used produced spectra for new breeding lines under current consideration. Appropriate data treatment allows calculation of a numerical estimate of the a-helix population relative to other secondary protein structures from the position and shape of the amide I absorption band. Current breeding lines show a substantial variance in this feature and its determination allows the prediction of relative quality for breadmaking to be taken into consideration for subsequent steps in the wheat breeding process. Data treatments include deconvolution, modeling of the individual resulting bands that contribute to the amide I band to enable measurement of the relative amounts of both forms. Results with specimens representing multiple crop years of hard winter wheat breeding are reported. It is evident that a range is available for the breeder to choose from, that allows including this protein molecular structural attribute in the selection process.

43 PARTICLE ACCELERATORS↗

Chemical Dynamics, Molecular Energetics, and Kinetics at the Synchrotron

Scientists at the Chemical Dynamics Beamline of the Advanced Light Source in Berkeley are continuously reinventing synchrotron investigations of physical chemistry and chemical physics with vacuum ultraviolet light. One of the unique aspects of a synchrotron for chemical physics research is the widely tunable vacuum ultraviolet light that permits threshold ionization of large molecules with minimal fragmentation. This provides novel opportunities to assess molecular energetics and reaction mechanisms, even beyond simple gas phase molecules. In this perspective, significant new directions utilizing the capabilities at the Chemical Dynamics Beamline are presented, along with an outlook for future synchrotron and free electron laser science in chemical dynamics. Among the established and emerging fields of investigations are cluster and biological molecule spectroscopy and structure, combustion flame chemistry mechanisms, radical kinetics and product isomer dynamics, aerosol heterogeneous chemistry, planetary and interstellar chemistry, and secondary neutral ion-beam desorption imaging of biological matter and materials chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benefits of Synchrotron Microangiography for Dynamic Studies of Smooth Muscle and Endothelial Roles in the Pathophysiology of Vascular Disease

Changes in endothelial and smooth muscle function compromise organ perfusion in the chronic disease states of diabetes, atherosclerosis and hypertension. Moreover, vascular dysfunction increases the likelihood of lethal acute events such as myocardial infarction and stroke, which are now leading causes of adult mortality. Many circulating and local tissue factors in these disease states contribute to impaired vasomotor regulation of the arterial vessels, leading to spasm, chronic constriction and eventually vessel remodelling. X-ray contrast absorption imaging allows assessment of vessel lumen diameter and the factors contributing to steady-state vessel calibre, however, conventional clinical devices (>200 {mu}m resolution) are not adequate to detect microvessels or accurately assess function in real time. Using synchrotron imaging we are now able to detect small vessel calibres ({approx}30 {mu}m) and quantify regional differences in calibre even under conditions of high heart rate (>500 bpm). Herein we describe recent experiments that were conducted at the Japanese Synchrotron, SPring-8 using anaesthetised Sprague-Dawley rats and C57Bl/6 mice and a synchrotron radiation contrast angiography (single narrow energy bandwidth) approach based on selective arterial injection of iodine contrast agents. Application of this approach to imaging of the heart and other vasculatures are described. Our studies show that within-animal comparisons of 3-4 branching orders of arterial vessels are possible using small bolus contrast injections and appropriate contrast washout times (15-30 min) in many organ systems. Determination of relative calibre changes before and after any treatment allows us to evaluate the contributions of different endogenous factors and ligand-receptor pathways in the maintenance of vasomotor tone. Finally, we will present our findings relating to novel therapies to prevent endothelial dysfunction in heart failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchrotron radiation from a runaway electron distribution in tokamaks

The synchrotron radiation emitted by runaway electrons in a fusion plasma provides information regarding the particle momenta and pitch-angles of the runaway electron population through the strong dependence of the synchrotron spectrum on these parameters. Information about the runaway density and its spatial distribution, as well as the time evolution of the above quantities, can also be deduced. In this paper, we present the synchrotron radiation spectra for typical avalanching runaway electron distributions. Spectra obtained for a distribution of electrons are compared with the emission of mono-energetic electrons with a prescribed pitch-angle. We also examine the effects of magnetic field curvature and analyse the sensitivity of the resulting spectrum to perturbations to the runaway distribution. The implications for the deduced runaway electron parameters are discussed. We compare our calculations to experimental data from DIII-D and estimate the maximum observed runaway energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ALICE—An advanced reflectometer for static and dynamic experiments in magnetism at synchrotron radiation facilities

We report on significant developments of a high vacuum reflectometer (diffractometer) and spectrometer for soft x-ray synchrotron experiments which allows conducting a wide range of static and dynamic experiments. Although the chamber named ALICE was designed for the analysis of magnetic hetero- and nanostructures via resonant magnetic x-ray scattering, the instrument is not limited to this technique. The versatility of the instrument was testified by a series of pilot experiments. Static measurements involve the possibility to use scattering and spectroscopy synchrotron based techniques (photon-in photon-out, photon-in electron-out, and coherent scattering). Dynamic experiments require either laser or magnetic field pulses to excite the spin system followed by x-ray probe in the time domain from nano- to femtosecond delay times. In this temporal range, the demagnetization/remagnetization dynamics and magnetization precession in a number of magnetic materials (metals, alloys, and magnetic multilayers) can be probed in an element specific manner. We demonstrate here the capabilities of the system to host a variety of experiments, featuring ALICE as one of the most versatile and demanded instruments at the Helmholtz Center in Berlin-BESSY II synchrotron center in Berlin, Germany.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field transients of coherent terahertz synchrotron radiation accessed via time-resolving and correlation techniques

Decaying oscillations of the electric field in repetitive pulses of coherent synchrotron radiation in the terahertz frequency range was evaluated by means of time-resolving and correlation techniques. Comparative analysis of real-time voltage transients of the electrical response and interferograms, which were obtained with an ultrafast zero-bias Schottky diode detector and a Martin-Puplett interferometer, delivers close values of the pulse duration. Consistent results were obtained via the correlation technique with a pair of Golay Cell detectors and a pair of resonant polarisation-sensitive superconducting detectors integrated on one chip. The duration of terahertz synchrotron pulses does not closely correlate with the duration of single-cycle electric field expected for the varying size of electron bunches. We largely attribute the difference to the charge density oscillations in electron bunches and to the low-frequency spectral cut-off imposed by both the synchrotron beamline and the coupling optics of our detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchrotron radiation by fast fermions in heavy-ion collisions

We study the synchrotron radiation of gluons by fast quarks in strong magnetic field produced by colliding relativistic heavy ions. We argue that due to high electric conductivity of plasma, the magnetic field is almost constant during the entire plasma lifetime. We calculate the energy loss due to synchrotron radiation of gluons by fast quarks. We find that the typical energy loss per unit length for a light quark at the Large Hadron Collider is a few GeV per fm. This effect alone predicts quenching of jets with p{sub perpendicular} up to about 20 GeV. We also show that the spin-flip transition effect accompanying the synchrotron radiation leads to a strong polarization of quarks and leptons with respect to the direction of the magnetic field. Observation of the lepton polarization may provide a direct evidence of existence of strong magnetic field in heavy-ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of Synchrotron Radiation from Electrons Accelerated in a Petawatt-Laser-Generated Plasma Cavity

The dynamics of plasma electrons in the focus of a petawatt laser beam are studied via measurements of their x-ray synchrotron radiation. With increasing laser intensity, a forward directed beam of x rays extending to 50 keV is observed. The measured x rays are well described in the synchrotron asymptotic limit of electrons oscillating in a plasma channel. The critical energy of the measured synchrotron spectrum is found to scale as the Maxwellian temperature of the simultaneously measured electron spectra. At low laser intensity transverse oscillations are negligible as the electrons are predominantly accelerated axially by the laser generated wakefield. At high laser intensity, electrons are directly accelerated by the laser and enter a highly radiative regime with up to 5% of their energy converted into x rays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Role of Synchrotron infra red microspectroscopy in studying epidermotropism of cutaneous T-cell lymphoma

The molecular mechanisms of epidermotropism in mycosis fungoides (MF) are not well understood to date. The aim of this study was to differentiate between epidermal and dermal lymphocytes within the skin of MF patients. This study was done on 10 MF patients with a mean age of 50 years diagnosed clinically in the Department of Dermatology, Cairo University, Egypt. A 6 mm biopsy was taken from each patient in order to confirm the diagnosis. Skin biopsies were cut, put on low e-slides and then stained with H&E. Further examination with Synchrotron infrared (IR) microspectroscopy was done in National Synchrotron Light Source - Brookhaven National Laboratory, New York, USA. Immunophenotyping using antibodies CD3, CD4, CD8, CD20 and CD30 was also done. Statistical analysis was done by Student's t-test and cluster analysis. Both epidermal and dermal lymphocytes were clustered separately. Also, Amide I and RNA and DNA within the lymphocytes were significantly different between the epidermis and the dermis. The biochemical analysis of protein, RNA and DNA with Synchrotron IR microspectroscopy is a promising tool for studying epidermotropism in cutaneous T-cell lymphoma.

43 PARTICLE ACCELERATORS↗