Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “switching frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A Single-Stage Isolated Resonant SiC DC/AC Inverter for Efficient High-Power Applications

This paper presents a single-stage series-resonant dual active half bridge (SR-DAHB) inverter suitable for high power applications. The topology is an isolated dual half-bridge circuit with an unfolding bridge. A combined phase-shift and frequency modulation technique is utilized to generate AC power output. In high-power applications where the switching devices operate at relatively high current and voltage, the switching loss becomes the major portion of the converter’s total loss as the devices are turned on and off under hard switching condition. The primary merit of the proposed single-stage SR-DAHB inverter with the combined phase-shift and frequency modulation control is to significantly reduce the switching loss so that it is not a function of load current. A precise and comprehensive power loss model is developed for both the SR-DAHB and DAHB to optimize the operation of the inverters. The objective of the optimization is to minimize the inverter total loss while calculating the optimum combination of frequency and phase shift. A 1.5 kV, 50 kW prototype was built to demonstrate the performance of the SRDAHB versus DAHB inverters with the combined phase-shift and frequency modulation control, and validate the theoretical analysis.

Tayebi, S. Milad↗

ac bidirectional motor controller

Test data are presented and the design of a high-efficiency motor/generator controller at NASA-Lewis for use with the Space Station power system testbed is described. The bidirectional motor driver is a 20 kHz to variable frequency three-phase ac converter that operates from the high-frequency ac bus being designed for the Space Station. A zero-voltage-switching pulse-density-modulation technique is used in the converter to shape the low-frequency output waveform.

Schreiner, K.↗

Defect-Enhanced Polarization Switching in the Improper Ferroelectric LuFeO 3

Results of switching behavior of the improper ferroelectric LuFeO 3 are presented. Here, using a model set of films prepared under controlled chemical and growth-rate conditions, it is shown that defects can reduce the quasi-static switching voltage by up to 40% in qualitative agreement with first-principles calculations. Switching studies show that the coercive field has a stronger frequency dispersion for the improper ferroelectrics compared to a proper ferroelectric such as PbTiO 3 . It is concluded that the primary structural order parameter controls the switching dynamics of such improper ferroelectrics.

36 MATERIALS SCIENCE↗

Improved Frequency-Domain Steady-State Modeling of the Dual-Active-Bridge Converter Considering Finite ZVS Transition Time Effects

This article presents an improved analytical modeling (IAM) approach for the dual-active-bridge (DAB) converter in the frequency-domain. Specifically, finite transition times are incorporated into the improved modeling that are significant in DAB converters operated at high frequency. The IAM approach is first motivated by comparing traditional frequency-domain modeling against realistic simulation results in LTspice. Next, the IAM approach is mathematically developed in an iterative fashion, where the conventional frequency-domain approach is used as the initialization of the operational behavior of the converter. Subsequent iterations of the IAM algorithm incorporate finite rise- and falltimes of device output capacitances based on detailed switching behavior analyses, which may considerably perturb the desired modulation parameters (i.e., phase shift and zero states). While the initially proposed IAM approach demonstrates advantages over ideal modeling, it is still shown to exhibit errors when applied to device transitions with significant nonlinearity in parasitic output capacitance. To account for this, a three-slope approximation to the switching transition is then motivated and developed, which enables significantly improved steady-state prediction accuracy. Simulation and experimental results confirm unacceptable inaccuracies associated with the conventional frequency-domain modeling across a wide range of operating conditions, alongside enhanced accuracy provided by the proposed modeling approach.

14 SOLAR ENERGY↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Phase and amplitude characteristics of InP:Fe modified interdigitated gap photoconductive microwave switches

The transmission amplitude and phase characteristics of InP:Fe modified interdigitated gap photoconductive microwave switches are reported. Measurements in the 0.1-1 GHz frequency range show that the phase is shifted about 90 deg and that the corresponding change in amplitude ranges from 43 dB at 0.1 GHz to 23 dB at 1 GHz when the illumination-induced conductance is switched from a low OFF-state value (aboit 4 x 10 to the -8 S) to a high ON-state value (5 mS). The observed characteristics can be described by a phase-shifting region and an amplitude modulation region. In the phase-shifting region the phase strongly depends on the conductance, and the amplitude is almost constant. In the amplitude modulation region both the amplitude and the phase depend on the conductance but the effect on the amplitude is much more pronounced. A lumped-element model describing the device performance is presented. It is concluded that these optoelectronic microwave switching devices are suitable for high-speed amplitude modulation but are not promising as high-speed phase shifters.

Andersson, Ingmar L.↗

AC/DC Power Systems with Applications for future Lunar/Mars base and Crew Exploration Vehicle

ABSTRACT The Power Systems branch at JSC faces a number of complex issues as it readies itself for the President's initiative on future space exploration beyond low earth orbit. Some of these preliminary issues - those dealing with electric power generation and distribution on board Mars-bound vehicle and that on Lunar and Martian surface may be summarized as follows: Type of prime mover - Because solar power may not be readily available on parts of the Lunar/Mars surface and also during the long duration flight to Mars, the primary source of power will most likely be nuclear power (Uranium fuel rods) with a secondary source of fuel cell (Hydrogen supply). The electric power generation source - With nuclear power being the main prime mover, the electric power generation source will most likely be an ac generator at a yet to be determined frequency. Thus, a critical issue is whether the generator should generate at constant or variable frequency. This will decide what type of generator to use - whether it is a synchronous machine, an asynchronous induction machine or a switched reluctance machine. The type of power distribution system - the distribution frequency, number of wires (3- wire, 4-wire or higher), and ac/dc hybridization. Building redundancy and fault tolerance in the generation and distribution sub-systems so that the system is safe; provides 100% availability to critical loads; continues to operate even with faulted sub-systems; and requires minimal maintenance. This report descril_es results of a summer faculty fellowship spent in the Power Systems Branch with the specific aim of investigating some of the lessons learned in electric power generation and usage from the terrestrial power systems industry, the aerospace industry as well as NASA's on-going missions so as to recommend novel surface and vehicle-based power systems architectures in support of future space exploration initiatives. A hybrid ac/dc architecture with source side and load side redundancies and including emergency generators on both ac and dc sides is proposed. The generation frequency is 400 Hz mostly because of the technology maturity at this frequency in the aerospace industry. Power will be distributed to several ac load distribution buses through solid state variable speed, constant frequency converters on the ac side. A segmented dc ring bus supplied from ac/dc converters and with the capability of connecting/disconnecting the segments will supply power to multiple de load distribution buses. The system will have the capability of reverse flow from dc to ac side in the case of an extreme emergency on the main ac generation side.

Chowdhury, Badrul H.↗

Prognostic health monitoring in switch-mode power supplies with voltage regulation

The system includes a current injection device in electrical communication with the switch mode power supply. The current injection device is positioned to alter the initial, non-zero load current when activated. A prognostic control is in communication with the current injection device, controlling activation of the current injection device. A frequency detector is positioned to receive an output signal from the switch mode power supply and is able to count cycles in a sinusoidal wave within the output signal. An output device is in communication with the frequency detector. The output device outputs a result of the counted cycles, which are indicative of damage to an a remaining useful life of the switch mode power supply.

Hofmeister, James P↗

Space Shuttle communications RF switch matrix

The Shuttle Orbiter communications equipment includes phase modulation (PM) and frequency modulation (FM) channels. The PM section has the capability of routing high levels of energy (175 W) from any one of four transmitters to any one of four antennas, mutually exclusive. The FM channel uses a maximum of 15-W power routed from either of two transmitters to one of two antennas, mutually exclusive. The paper describes the design and the theory of a logic-controlled RF switch matrix devised for the purposes cited. Both PM and FM channels are computer-controlled with manual overrides. The logic interface is realized with CMOS logic for low power consumption and high noise immunity. The interior of the switch matrix is maintained at a pressure of 15 psi (90% nitrogen, 10% helium) by an electron beam-welded encapsulation. The computational results confirm the viability of the RF switch matrix concept.

Winch, R.↗

Monolithic optoelectronic circuit design for on-chip terahertz applications

We demonstrate a monolithic coplanar stripline platform for on-chip terahertz (THz) generation, transmission, and detection, addressing key challenges of mode purity, bandwidth, and referencing. Capacitive coupling of the photoconductive generator switch enforces pure odd-mode propagation, increases THz field strength, and extends the operational frequency range, achieving 0.05–1.4 THz. Our architecture enables fully monolithic fabrication with amorphous silicon switches, in situ field referencing, and galvanic isolation between generation and detection. Finite-element simulations and experiments confirm that suppressing parasitic modes improves signal integrity, providing a robust platform for high-fidelity THz spectroscopy, ultrafast electronics, and nanoscale quantum materials research.

Capacitive coupling↗

Pulse evolution and mode selection characteristics in a TEA-CO2 laser perturbed by injection of external radiation

A grating-tunable TEA-CO2 laser with an unstable resonator cavity, modified to allow injection of CW CO2 laser radiation at the resonant transition line by means of an intracavity NaCl window, has been used to study the coupling requirements for generation of single frequency pulses. The width and shape of the mode selection region, and the dependence of the gain-switched spike buildup time and the pulse shapes on the intensity and detuning frequency of the injected radiation are reported. Comparisons of the experimental results with previously reported mode selection behavior are discussed.

Flamant, P. H.↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Quantifying the quantum heat contribution from a driven superconducting circuit

Heat flow management at the nanoscale is of great importance for emergent quantum technologies. For instance, a thermal sink that can be activated on-demand is a highly desirable tool that may accommodate the need to evacuate excess heat at chosen times, e.g., to maintain cryogenic temperatures or reset a quantum system to ground, and the possibility of controlled unitary evolution otherwise. Here we propose a design of such heat switch based on a single coherently driven qubit. We show that the heat flow provided by a hot source to the qubit can be switched on and off by varying external parameters, the frequency and the intensity of the driving. The complete suppression of the heat flow is a quantum effect occurring for specific driving parameters that we express and we analyze the role of the coherences in the free-qubit energy eigenbasis. We finally study the feasibility of this quantum heat switch in a circuit QED setup involving a charge qubit coupled to thermal resistances. In this work, we demonstrate robustness to experimental imperfections such as additional decoherence, paving the road towards experimental verification of this effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submicrosecond Power-Switching Test Circuit

A circuit that changes an electrical load in a switching time shorter than 0.3 microsecond has been devised. This circuit can be used in testing the regulation characteristics of power-supply circuits . especially switching power-converter circuits that are supposed to be able to provide acceptably high degrees of regulation in response to rapid load transients. The combination of this power-switching circuit and a known passive constant load could be an attractive alternative to a typical commercially available load-bank circuit that can be made to operate in nominal constant-voltage, constant-current, and constant-resistance modes. The switching provided by a typical commercial load-bank circuit in the constant-resistance mode is not fast enough for testing of regulation in response to load transients. Moreover, some test engineers do not trust the test results obtained when using commercial load-bank circuits because the dynamic responses of those circuits are, variously, partly unknown and/or excessively complex. In contrast, the combination of this circuit and a passive constant load offers both rapid switching and known (or at least better known) load dynamics. The power-switching circuit (see figure) includes a signal-input section, a wide-hysteresis Schmitt trigger that prevents false triggering in the event of switch-contact bounce, a dual-bipolar-transistor power stage that drives the gate of a metal oxide semiconductor field-effect transistor (MOSFET), and the MOSFET, which is the output device that performs the switching of the load. The MOSFET in the specific version of the circuit shown in the figure is rated to stand off a potential of 100 V in the "off" state and to pass a current of 20 A in the "on" state. The switching time of this circuit (the characteristic time of rise or fall of the potential at the drain of the MOSFET) is .300 ns. The circuit can accept any of three control inputs . which one depending on the test that one seeks to perform: a repetitive waveform from a signal generator, momentary closure of a push-button switch, or closure or opening of a manually operated on/off switch. In the case of a signal generator, one can adjust the frequency and duty cycle as needed to obtain the desired AC power-supply response, which one could display on an oscilloscope. Momentary switch closure could be useful for obtaining (and, if desired, displaying on an oscilloscope set to trigger on an event) the response of a power supply to a single load transient. The on/off switch can be used to switch between load states in which static-load regulation measurements are performed.

Folk, Eric N.↗

Synchronous micromechanically resonant programmable photonic circuits

Abstract Programmable photonic integrated circuits (PICs) are emerging as powerful tools for control of light, with applications in quantum information processing, optical range finding, and artificial intelligence. Low-power implementations of these PICs involve micromechanical structures driven capacitively or piezoelectrically but are often limited in modulation bandwidth by mechanical resonances and high operating voltages. Here we introduce a synchronous, micromechanically resonant design architecture for programmable PICs and a proof-of-principle 1×8 photonic switch using piezoelectric optical phase shifters. Our design purposefully exploits high-frequency mechanical resonances and optically broadband components for larger modulation responses on the order of the mechanical quality factor Q m while maintaining fast switching speeds. We experimentally show switching cycles of all 8 channels spaced by approximately 11 ns and operating at 4.6 dB average modulation enhancement. Future advances in micromechanical devices with high Q m , which can exceed 10000, should enable an improved series of low-voltage and high-speed programmable PICs.

42 ENGINEERING↗

A 50-kW Bidirectional Step-up / Step-down DC/DC Oak Ridge Converter for Wireless Charger Applications

This study presents a novel bidirectional concept by using Oak Ridge Converter (ORC) for wireless energy conversion (WEC) technologies such as wireless electric vehicle (EV) chargers, wireless mobile or energy storage systems (MESS / ESS), etc. The presented system can be deployed in a bidirectional wireless power transfer (WPT) structure for different input voltages by using two different operating frequencies. The proposed concept here achieves zero voltage switching (ZVS) in during step-up and step-down configurations. The system overall theoretical design and experimental test results are presented for 50 kW power transfer in both bidirectional operations modes. The laboratory demonstration of the system is presented for the three-phase bidirectional system with 6 inches of airgap between the coils and output of 560 VDC with 95.4% dc-to-dc efficiency.

Asa, Erdem↗