Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “surface cracks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Stationary Shoulder Friction Stir Assisted Scribe Technique for Dissimilar Joining

We report on implementation of a stationary shoulder in dissimilar joints of Al-steel and Al-carbon fiber reinforced polymer (CFRP) using friction stir assisted scribe technology (FaST ). Viable joint strength similar to that with the conventional FAST process was demonstrated in Al-steel. A significant improvement in as-welded surface roughness for both Al-steel and Al-CFRP cases was achieved by using stationary shoulder. Interrupted lap shear tests performed on Al-steel joints and a corresponding computational model indicate the joint failure typically occurs in Al sheet via a crack tip that originates at the steel hook tip on the loading side. A similar fracture path was observed in an Al-CFRP joint.

Das, Hrishikesh↗

Status of the Characterization of DEs from the Full Circumference Examination of the Inner Container Closure Weld Region (FY2020)

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR a laser confocal microscope (LCM) is used to perform close visual examination of the surface and measurements of corrosion features on the surface. DE containers from FY13 through FY16 were screened with three candidates selected for full circumference evaluation (FCE) according to the ICCWR examination protocol, During the FCE, FY16 DE05 and FY15 DE07 showed suspect major corrosion events, FY16 DE05 Section C2 shows two crack-like features, identified as Denebola and Draco. Both features are located at the boundary of Zone 2 and Zone 3. Consequently, Section C2 of FY16 DE05 was selected for examination by serial metallography at Savannah River National Laboratory (SRNL). For FY15 DE07 the suspect corrosion events were observed on Sections Cl and C2. Section Cl shows one crack-like feature, identified as Acrux. Section C2 shows three crack-like features, identified as Bellatrix, Cursa Minor and Cursa Major. Unlike Acrux and Bellatrix, which are located at the boundary of Zone 2 and Zone 3, Cursa Minor and Cursa Major are located in Zone 2. Sections Cl and C2 of FY15 DE07 were sent to Los Alamos National Laboratory (LANE) for characterization by X-Ray Tomography (XRT).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microstructure-Based Degradation Modeling in Solid Oxide Cells

The presentation is intended for a graduate class in Georgia Southern University taught by Dr. Hayri Sezer on electrochemistry, SOFC and Li ion battery. It summaries NETL's recent works on microstructure-based modeling of degradation in solid oxide cells. It covers the degradation mechanism of Ni coarsening, Ni migration and the build-up of oxygen partial pressure inside the electrolyte. The phase-field models developed for Ni coarsening and migration are reviewed and the results are compared to experiments in literature to examine different diffusion mechanisms (Ni self-diffusion, Ni(OH)2 diffusion in pores and Ni(OH) surface diffusion) and driving forces (Ni(OH)x concentration and Ni-YSZ contact angle change). It also demonstrates the developed model for oxygen partial pressure and shows that the predicted oxygen partial pressure can explain the Ni oxidation in the hydrogen electrode and crack growth on the electrolyte-oxygen electrode interface under certain operating conditions.

nickel coarsening↗

Microstructurally driven self-sharpening mechanism in beaver incisor enamel facilitates their capacity to fell trees

Beavers ( Castor ) stand out among mammals for their unique capacity to fell trees using their large, ever-growing incisors. This routine consumption of resistant fodder induces prodigious wear in the lower incisors, despite this blunting effect the incisors maintain a remarkably sharp cutting edge. Notably, the enamel edges of their incisors show a highly complex two-part microstructure of which the biomechanical import is unknown. Here, using fracture analysis, nanoindentation, and wear testing on North American beaver ( C. canadensis ) incisors we test the microstructure's possible contribution to maintaining incisal sharpness. Although comparable in hardness, the inner enamel preferentially fails and readily wears at 2.5 times the rate of the outer enamel. The outer microstructure redirects all fractures in parallel, decreasing fracture coalescence. Conversely, the inner microstructure facilitates crack coalescence increasing the wear rate by isolating layers of enamel prisms that readily fragment. Together these two architectures form a microstructurally driven self-sharpening mechanism contained entirely within the thin enamel shell. Here, our results demonstrate that enamel microstructures exposed at the occlusal surface can markedly influence both enamel crest shape and surface texture in wearing dentitions. The methods introduced here open the door to exploring the biomechanical functionality and evolution of enamel microstructures throughout Mammalia.

59 BASIC BIOLOGICAL SCIENCES↗

The influence of electrochemical cycling protocols on capacity loss in nickel-rich lithium-ion batteries

The transition towards electric vehicles and more sustainable transportation is dependent on lithium-ion battery (LIB) performance. Ni-rich layered transition metal oxides, such as NMC811 (LiNi 0.8 Mn 0.1 Co 0.1 O 2 ), are promising cathode candidates for LIBs due to their higher specific capacity and lower cost compared with lower Ni content materials. However, complex degradation mechanisms inhibit their use. In this work, tailored aging protocols are employed to decouple the effect of electrochemical stimuli on the degradation mechanisms in graphite/NMC811 full cells. Using these protocols, impedance measurements, and differential voltage analysis, the primary drivers for capacity fade and impedance rise are shown to be large state of charge changes combined with high upper cut-off voltage. Focused ion beam-scanning electron microscopy highlights that extensive microscale NMC particle cracking, caused by electrode manufacturing and calendering, is present prior to aging and not immediately detrimental to the gravimetric capacity and impedance. Scanning transmission electron microscopy electron energy loss spectroscopy reveals a correlation between impedance rise and the level of transition metal reduction at the surfaces of aged NMC811. The present study provides insight into the leading causes for LIB performance fading, and highlights the defining role played by the evolving properties of the cathode particle surface layer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feasibility of Lead Fast Reactor Heat Exchanger Tube Online Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Deciphering atomistic mechanisms of the gas-solid interfacial reaction during alloy oxidation

Gas-solid interfacial reaction is critical to many technological applications from heterogeneous catalysis to stress corrosion cracking. A prominent question that remains unclear is how gas and solid interact beyond chemisorption to form a stable interphase for bridging subsequent gas-solid reactions. Here, we report real-time atomic-scale observations of Ni-Al alloy oxidation reaction from initial surface adsorption to interfacial reaction into the bulk. We found distinct atomistic mechanisms for oxide growth in O 2 and H 2 O vapor, featuring a “step-edge” mechanism with severe interfacial strain in O 2 , and a “subsurface” one in H 2 O. Ab initio density functional theory simulations rationalize the H 2 O dissociation to favor the formation of a disordered oxide, which promotes ion diffusion to the oxide-metal interface and leads to an eased interfacial strain, therefore enhancing inward oxidation. Our findings depict a complete pathway for the Ni-Al surface oxidation reaction and delineate the delicate coupling of chemomechanical effect on gas-solid interactions.

36 MATERIALS SCIENCE↗

Progress Toward Molten Salt Reactor Heat Exchanger On-Line Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Summary of Chloride-induced Stress Corrosion Cracking Experiments with a Spent Fuel Storage Canister Large Plate

This report provides a comprehensive summary of the crack growth rate testing and the experiments to evaluate the corrosion behavior of welded plate material taken from the Sandia National Laboratories’ full-size mockup of a spent nuclear fuel (SNF) dry storage canister. The information includes that previously reported, and new work on detailed surface characterization of the corrosion attack from the large plate experiment. The work and the results inform aging management programs for the SNF canisters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding the role of water-soluble guar gum binder in reducing capacity fading and voltage decay of Li-rich cathode for Li-ion batteries

The practical application of high-capacity Li-rich cathode materials is hindered by capacity fading and voltage decay. The capacity fading and voltage decay could be effectively overcome by using water-soluble guar gum (GG) binder instead of traditional polyvinylidene fluoride (PVDF). However, the specific role of the GG binder is not clear yet, though the GG binder can significantly improve the electrochemical performance of Li-rich cathode. To understand the effect of GG binder on the morphology, microstructure of electrode and electrode/electrolyte interfaces, ex-situ scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray adsorption near edge spectroscopy (XANES), in-situ electrochemical impedance spectroscopy (EIS) were applied to comparatively study the charge-discharge processes of Li-rich Li 1.2 Ni 0.2 Mn 0.6 O 2 cathode when using GG and PVDF as binders. The results indicate that the GG binder can prevent electrode crack and active material loss, ascribing to the strong mechanical adhesion of GG binder with active material particles and current collector. It has found that the GG binder can also induce the formation of a uniform layer on Li 1.2 Ni 0.2 Mn 0.6 O 2 particles’ surface. As a consequence, both the electrolyte decomposition and the electrode corrosion were significantly inhibited. The strong chelation between Mn 2+ and polar OH group restrain Mn ion dissolution, which contributes to surface structural transformation mitigation. Here, our study reveals the role of water-soluble GG binder in reducing capacity fading and voltage decay of Li-rich material and is of great importance in design functional binders for high-performance Li-rich electrodes.

25 ENERGY STORAGE↗

Effect of die design on microstructure and mechanical joint strength in friction self-piercing riveted AA7055-T76 and AA7055-T76

In the present study, a unique friction self-piercing riveting (F-SPR) was applied to join high-strength, low-ductility aluminum alloy (AA) 7055-T76 and AA7055-T76 to mitigate a cracking issue. Also, the effect of die design on both joint formation and the mechanical joint performance were investigated. A crack-free joint was achieved when joining AA7055-T76 and AA7055-T76 by F-SPR. As the bottom diameter of the die increased, the mechanical interlocking distance initially increased then became almost saturated. At the same time, the solid-state bonding gradually disappeared, and the lap-shear fracture changed from bottom aluminum fracture to rivet pull-out with partial bottom aluminum fracture. The average maximum lap-shear joint strength of 11.57 kN and cross tension of 5.65 kN were achieved from the D2 die design owing to the combined contributions from high mechanical interlocking distance and good solid-state bonding at the joint interface. Ultrafine grain refinement was observed at the region next to the rivet shank outer surface and along the materials flow line between the top and bottom aluminum sheet in the rivet cavity. Further, because of the same joint-process parameters, the hardness profile at the joints made by different dies did not show obvious differences. As the distance from the base metal to the rivet outer surface decreased, frictional heat caused the hardness to initially decrease from 190 to 150 HV in the heat-affected zone. Hardness increased up to 175 HV in the thermomechanical affected zone (TMAZ-I) owing to large plastic deformation.

36 MATERIALS SCIENCE↗

Chromium Tolerant, Highly Active and Stable Electrocatalytic Internal Surface Coating for Cathode of Commercial SOFCs (Final Report)

This project is aimed to develop a chromium (Cr) tolerant, highly active, and stable coating layer on the internal surfaces of the porous composite cathode from commercially available SOFCs. Such coating layer was developed using the additive manufacturing process of Atomic Layer Deposition (ALD) and has been applied on the cathode consisting of either an electronic conductor of LaxSr 1-x MnyO 3-δ (LSM) or mixed ionic and electronic conducting La x Sr 1-x Co y Fe 1-y O 3-δ (LSCF). PI's work has demonstrated that the internal surface of cathode from the commercial cells, can be further tailored using ALD coating to dramatically enhance the cell performance. For instance, ALD layer consisting heterostructured nano composite of nano-Pt and nano-(Mn 0.8 Co 0.2 ) 3 O 4 oxide on the internal surface of porous LSM/YSZ cathode from SOFCs, has resulted in the large reduction of the cell polarizations resistance by up to 53%, and enormous increase of power density over 370%. For the cells with LSCF/Sm 2 O 3 doped CeO 2 (SDC) cathode, the conformal layer of nano-composite consisting of superjacent CoOx and subjacent minimum amount of Pt nano-grains has resulted in the power density enhancement by 126% for the large scale industry tubular cells at 750°C, and both the performance enhancement and nanostructure of the ALD layer are stable over ~ 2000 h continuous operation performed at industry test station. In the meanwhile, those ALD coating layer developed by PI's work is also inherently Cr-tolerant, and could act as physical barrier for preventing Cr diffusion into the cathode backbone, so as to mitigate the Cr poisoning effect on the cathode. In this project, the impact of Cr on the performance of those ALD coated commercial cells has been evaluated. Based on evolution of the cell performance, the ALD coating layer chemistry and ALD coating layer thickness has been optimized to maximize the overall Cr tolerance, cell power density and cell longevity. Different ALD coating has been applied onto the internal surface of LSM/YSZ and LSCF/SDC backbone respectively. The architecture/scaffold structures on the internal surface of different cathode, designed by this project, was catalogued and analyzed using High Resolution Transmission Electron Microscopy (HRTEM), and cell power/durability performance are assured via comprehensive electrochemical performance testing in the industry operation relevant conditions. The impact of the electrochemical operation current density, the water humidity, the cell operation temperature, and cell operation duration on the Cr tolerance of ALD coated cells has been systematically investigated. There is completely different nanostructure degradation mechanisms between LSM and LSCF cells induced by Cr contamination. For the LSCF/SDC baseline cell, With the Cr source, there is no apparent Sr surface segregation phase even for the baseline cell operated for 3000 h at 750 °C. With the Cr source, there is significant amorphous (SrCr)Ox phase accumulated in the original pore region. For the commercial baseline cells, Cr contaminants on the LSM electrode severely impacted the entire cell's electrochemical performance and nanostructure degradation. Those degradations include (1). Peak power density loss of 64 % after 109 h of operation. The dramatic increase in Rp (2). They are cracking at LSM/SSZ interface, LSM grains. SSZ remains intact but with (CrMn)Ox. By contrast, ALD coating (MnCo)Ox/Pt dramatically improves the Cr resistance, as follows (1). ALD-coated cell with a power density is 280-380 % of the baseline cell, depending on the ALD layer thickness. (2). For a cell with a 20 nm thick ALD layer, there is a large performance enhancement (> 200 % power density) induced by ALD coating of Cr-tolerant Mn 0.8 Co 0.2 Ox. (3). For a cell with a 20 nm thick ALD layer, after 168 h at 750 °C power density of the ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination for 109 h. The ALD coating on the internal surface of cathode developed by this project integrated multi-functions. Those multi-functions include (1). Dramatically improving the cell power density for the commercial cells; (2). Dramatically improving contamination resistance of the cathode, for being an excellent protection coating layer sealing off Cr contamination. (3). Dramatically increasing the cell longevity by potentially preventing the microstructure evolution and grain coarsening of the cathode. Overall, this project will provide a simple solution to simultaneously enhance power density and increase the reliability, robustness, and endurance of commercial SOFCs, over the entire operating temperature range of 650-800 °C. For the inherently functional SOFC, the ALD coating of LSM based cathode mitigate the Cr-contamination. Power density of ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination. In addition to SOFCs, the novel on-demand design approach and creation of multifunctional heterogeneous architecture on the electrode surface presented in this work opens further research for their application in other types of fuel cells, batteries, and sensors for which electrochemical reactions on the surface are similarly critical.

36 MATERIALS SCIENCE↗

Accurately constituting robust interfaces for high-performance high-energy lithium metal batteries

High-energy lithium metal batteries (LMBs) have received ever-increasing interest. Among them, coupling lithium metal (Li) with nickel-rich material, LiNi x Mn y Co z O 2 (NMCs, x ≥ 0.6, x + y + z = 1), is promising because Li anodes enable an extremely high capacity (∼3860 mA h g −1 ) and the lowest redox potential (−3.04 V vs. standard hydrogen electrode), while NMCs can achieve a much higher capacity of ∼200 mA h g −1 and lower cost than those of LiCoO 2 . However, the resultant Li‖NMC cells have been hindered from commercialization due to a series of challenges related to the interface stability of both Li anodes and NMC cathodes. Specifically, Li anodes suffer from Li dendritic growth and the formation of solid electrolyte interphase (SEI), while NMC cathodes suffer from the formation of cathode electrolyte interphase (CEI) and other interface-related issues, including transition metal dissolution, oxygen release, cracking, and so on. To tackle these issues, recently, two sister techniques, atomic and molecular layer deposition (ALD and MLD), have emerged and exhibit tremendous capabilities to accurately constitute robust interfaces to achieve high-performance Li‖NMC LMBs. They can uniquely develop uniform and conformal films as surface coatings of LMBs in a precisely controllable mode at the atomic/molecular level, while proceeding with film deposition at low temperatures (e.g., ≤250 °C). In this Feature Article, we review the latest research progress in developing novel surface coatings via ALD and MLD for Li‖NMC LMBs and discuss outcomes for pursuing high performance.

25 ENERGY STORAGE↗

SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking (FY2020 Progress Report)

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g. height, color and grayscale values; all as functions of a location in a plane projection). It is the objective of this project to produce a user-friendly interface that incorporated all operations needed to perform surface examination. For this reason, a Matlab-based Graphical User Interface (GUI) was created to integrate data input with software developed for processing and evaluation. In summary, the GUI permits selective downloading of binary data, interrogation of attributes, data labeling, flagging of significant features, execution of Machine Learning (ML) algorithms, output of parameters for trained ML algorithms, reports of ML model accuracy with respect to labeled data, and generation of graphical representations of various analyses.

3013 corrosion↗

Acoustic sensing and autoencoder approach for abnormal gas detection in a spent nuclear fuel canister mock-up

Currently, spent nuclear fuel (SNF) from commercial nuclear power plants is stored in stainless-steel canisters for interim dry storage. To provide an inert environment, these canisters are backfilled with helium after vacuum drying. However, the helium environment may be contaminated during extended storage because of the material degradation. For example, the heavier fission gas xenon may be released from the fuel rods into the canister cavity should the fuel cladding be breached. Other gases such as air and water vapor may also be present as a result of leakage caused by chloride-induced stress corrosion cracking on the canister walls or by insufficient vacuum drying. Therefore, monitoring the gas composition can provide critical information about the health of SNF canisters. In this study, noninvasive testing was conducted on a 2/3-scaled SNF canister mock-up using acoustic sensing. Ultrasonic transducers were placed on the exterior surface of the canister to probe the gas composition. A dataset was collected by sealing the canister mock-up and introducing up to 1.53% argon or 1.29% air into the helium background gas. Three methods were used to detect changes in the gas composition: the time-of-flight (TOF) method, the differential method, and the autoencoder method. Results showed that the TOF method had sufficient resolution to detect abnormal gas concentrations of less than 1.0%. The differential method demonstrated a periodic in-phase and out-of-phase behavior between the benchmark (i.e., pure helium) and abnormal (i.e., with argon or air) state signals. The variational autoencoder (VAE) and the Wasserstein autoencoder (WAE) were trained on the benchmark data and were applied directly to the abnormal state data. It was found that both the unsupervised VAE and the WAE were able to distinguish the benchmark and abnormal states of the canister mock-up based on the reconstruction error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring of helium gas leakage from canister storing spent nuclear fuel: Radiological consequences and management

Chloride-induced stress corrosion cracking (CISCC) of canisters has been identified as a potential degradation mechanism requiring ageing management — especially in a marine air environment. Methods for monitoring helium gas leakage from canisters have been developed on the basis of a phenomenon that the bottom temperature of the canister increases as the top temperature of the canister decreases when helium gas leaks during storage. In this paper, we consider the radiological consequences of CISCC based on two scenarios of helium gas leakage and propose effective management that includes a timeline for monitoring and mitigation. Monitoring helium gas leakage by measuring the difference in temperature between canister surfaces in the dry cask storage of spent fuel (SF) can detect leakage before SF undergoes oxidation as a result of air ingress and before country-specific regulatory limits of off-site doses are exceeded, thereby enabling mitigatory action.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grain Size Variations in the Murray Formation: Stratigraphic Evidence for Changing Depositional Environments in Gale Crater, Mars

The lowermost exposure of the Murray formation in Gale crater, Mars, was interpreted as sediment deposited in an ancient lake based on data collected by the Curiosity rover. Constraining the stratigraphic extent and duration of this environment has important implications for the paleohydrology of Gale. Insights into early Martian environments and paleofluid flow velocity can be obtained from grain size in rocks. Visual inspection of grain size is not always available for rocks investigated at field sites on Mars due to limited image coverage. But grain sizes can also be estimated from the Gini Index Mean Score, a grain-size proxy that uses point-to-point chemical variations in ChemCam Laser Induced Breakdown Spectroscopy data. Here, new Gini Index Mean Score results indicate that the Murray formation is dominated by mudstones with grains smaller than the spatial resolution of all rover cameras. Intervals of fine to coarse sandstone also are present, some of which are verified using observations of grain size and sedimentary structures in associated images. Overall, results demonstrate that most of the Murray consists of mudstone, suggesting settling of grains from suspension in low energy depositional environments such as lakes. Some of the mudstones contain desiccation cracks indicating periods of drying with a lowering of lake water level. However, beds and lenses of cross-bedded sandstones are common at specific intervals, suggesting episodes of fluvial and possibly eolian deposition. The persistence of lacustrine deposits interspersed with fluvial deposits suggests that liquid water was sustained on the Martian surface for tens of thousands to millions of years.

58 GEOSCIENCES↗