Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Mesoscopic approach to modeling electric vehicle fleets based upon driving activity data to investigate recharge strategies’ impact on grid loads

This paper presents a mesoscopic model to populate a set of sub-fleets of battery electric vehicles (BEVs) that simulates how grid power demand changes with varied mixes of different charging strategies. The proposed model considers real driving activities of vehicles based on the National Household Travel Survey (NHTS) and various charging strategies while parked (at home and in other locations). To be easily scaled to any fleet size, a mesoscopic model is implemented, where BEVs with the same physical properties and driving schedules and clustered together into sub-fleets. The degree of granularity is explored for stable results. Monte Carlo simulations were run to demonstrate the potential of this model's use in grid loads under various charging strategies. Furthermore, an example cost function was optimized to demonstrate finding optimal allocations of charging strategies.

Electric Vehicles, Grid Integration, Monte Carlo S↗

An Energy Efficient Ethernet Strategy Based on Traffic Prediction and Shaping

Recently, different communities in computer science, telecommunication, and control systems have devoted a huge effort towards the design of energy efficient solutions for data transmission and network management. This paper collocates along this research line and presents a novel energy efficient strategy conceived for Ethernet networks. The proposed strategy, which exploits the opportunities offered by the IEEE 802.3az amendment to the Ethernet standard (known as energy efficient Ethernet) is based on the possibility of predicting the future traffic from the analysis of the current data flow. In agreement with the results of such a dynamic prediction, Ethernet links can be forced into a low power consumption state for variable intervals. Theoretical bounds are derived to detail how the performance figures depend on the parameters of the designed strategy and scale with respect to traffic load. Furthermore, simulation results carried out with both real and synthetic traffic traces are presented to prove the effectiveness of the strategy, which leads to considerable energy savings at the cost of only a limited bounded delay in data delivery.

Cenedese, Angelo (ORCID:0000000322495094)↗

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY↗

Proactive Assignment Strategy With Human Choice Models for Boosting Pooled Rideshare Service

This study analyzes various human factors considerations in estimating discounts for pooled rideshare trips. The discounts are utilized in an optimization-based rideshare assignment strategy (proactive strategy) and compared against each other, as well as a heuristic strategy attempting to replicate current real-world pooling rates. Simulations within Austin, Texas and Greenville, South Carolina, reveal the proactive strategy’s ability to increase average vehicle occupancy by 0.23 persons/mile in Austin and 0.52 persons/mile in Greenville. A significant ability to decrease trip rejections and increase profitability is also observed. Finally, the strengths of particular combinations of factors are discussed relative to their effectiveness in each region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques

This paper presents a review of control strategies, stability analysis, and stabilization techniques for dc microgrids (MGs). Overall control is systematically classified into local and coordinated control levels according to respective functionalities in each level. As opposed to local control, which relies only on local measurements, some line of communication between units needs to be made available in order to achieve the coordinated control. Depending on the communication method, three basic coordinated control strategies can be distinguished, i.e., decentralized, centralized, and distributed control. Decentralized control can be regarded as an extension of the local control since it is also based exclusively on local measurements. In contrast, centralized and distributed control strategies rely on digital communication technologies. A number of approaches using these three coordinated control strategies to achieve various control objectives are reviewed in this paper. Moreover, properties of dc MG dynamics and stability are discussed. This paper illustrates that tightly regulated point-of-load converters tend to reduce the stability margins of the system since they introduce negative impedances, which can potentially oscillate with lightly damped power supply input filters. It is also demonstrated that how the stability of the whole system is defined by the relationship of the source and load impedances, referred to as the minor loop gain. Several prominent specifications for the minor loop gain are reviewed. Finally, a number of active stabilization techniques are presented.

30 DIRECT ENERGY CONVERSION↗

A Strategy for Forced Oscillation Suppression

Wide-area time-synchronized measurements have recently revealed troublesome forced oscillations (FOs) within modern synchronized power grids. In some cases, these FOs represent a dangerous hazard to the system. Recent research has focused on locating the source of FOs to provide operators with knowledge for mitigating their impact locally. This paper presents a complementary mitigation strategy, which is to purposely induce a second oscillation into the grid which cancels the impact of the FO. Such a strategy is complementary in that it may provide valuable time to operators attempting to locate the FOs source and to determine how to rectify it. This paper presents a suppression control strategy which modulates controllable devices to automatically cancel the impact of the FO without the need for locating the source of the original FO. The strategy is based upon tuned feedback control. In this study, the approach is demonstrated on a simulation system via modulation of inverter-based generation.

42 ENGINEERING↗

A strategy to objectively evaluate the necessity of correcting detected target deviations in image guided radiotherapy

Image guided radiotherapy technologies are being increasingly utilized in the treatment of various cancers. These technologies have enhanced the ability to detect temporal and spatial deviations of the target volume relative to planned radiation beams. Correcting these detected deviations may, in principle, improve the accuracy of dose delivery to the target. However, in many situations, a clinical decision has to be made as to whether it is necessary to correct some of the deviations since the relevant dosimetric impact may or may not be significant, and the corresponding corrective action may be either impractical or time consuming. Ideally this decision should be based on objective and reproducible criteria rather than subjective judgment. In this study, a strategy is proposed for the objective evaluation of the necessity of deviation correction during the treatment verification process. At the treatment stage, without any alteration from the planned beams, the treatment beams should provide the desired dose coverage to the geometric volume identical to the planning target volume (PTV). Given this fact, the planned dose distribution and PTV geometry were used to compute the dose coverage and PTV enclosure of the clinical target volume (CTV) that was detected from imaging during the treatment setup verification. The spatial differences between the detected CTV and the planning CTV are essentially the target deviations. The extent of the PTV enclosure of the detected CTV as well as its dose coverage were used as criteria to evaluate the necessity of correcting any of the target deviations. This strategy, in principle, should be applicable to any type of target deviations, including both target deformable and positional changes and should be independent of how the deviations are detected. The proposed strategy was used on two clinical prostate cancer cases. In both cases, gold markers were implanted inside the prostate for the purpose of treatment setup verification and were used to determine potential target deviations. To derive the detected CTV geometry from the planning CTV based on the locations of the gold markers, the CTV was approximated with an elastic semirigid body model. The derived CTV geometry and shape were confirmed with CBCT imaging. The evaluation results and the related mathematical equations and computational algorithm are presented. It is concluded that the proposed strategy is potentially useful in establishing objective criteria for the necessity of correction of the target deviations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

General strategy for the protection of organs at risk in IMRT therapy of a moving body

We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dose delivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control of radiation delivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dose delivered to OAR in cases where organs at risk move relative to a treatment target.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automated generation of IMRT treatment plans for prostate cancer patients with metal hip prostheses: Comparison of different planning strategies

Purpose: To compare IMRT planning strategies for prostate cancer patients with metal hip prostheses.Methods: All plans were generated fully automatically (i.e., no human trial-and-error interactions) using iCycle, the authors' in-house developed algorithm for multicriterial selection of beam angles and optimization of fluence profiles, allowing objective comparison of planning strategies. For 18 prostate cancer patients (eight with bilateral hip prostheses, ten with a right-sided unilateral prosthesis), two planning strategies were evaluated: (i) full exclusion of beams containing beamlets that would deliver dose to the target after passing a prosthesis (IMRT{sub remove}) and (ii) exclusion of those beamlets only (IMRT{sub cut}). Plans with optimized coplanar and noncoplanar beam arrangements were generated. Differences in PTV coverage and sparing of organs at risk (OARs) were quantified. The impact of beam number on plan quality was evaluated.Results: Especially for patients with bilateral hip prostheses, IMRT{sub cut} significantly improved rectum and bladder sparing compared to IMRT{sub remove}. For 9-beam coplanar plans, rectum V{sub 60Gy} reduced by 17.5%{+-} 15.0% (maximum 37.4%, p= 0.036) and rectum D{sub mean} by 9.4%{+-} 7.8% (maximum 19.8%, p= 0.036). Further improvements in OAR sparing were achievable by using noncoplanar beam setups, reducing rectum V{sub 60Gy} by another 4.6%{+-} 4.9% (p= 0.012) for noncoplanar 9-beam IMRT{sub cut} plans. Large reductions in rectum dose delivery were also observed when increasing the number of beam directions in the plans. For bilateral implants, the rectum V{sub 60Gy} was 37.3%{+-} 12.1% for coplanar 7-beam plans and reduced on average by 13.5% (maximum 30.1%, p= 0.012) for 15 directions.Conclusions: iCycle was able to automatically generate high quality plans for prostate cancer patients with prostheses. Excluding only beamlets that passed through the prostheses (IMRT{sub cut} strategy) significantly improved OAR sparing. Noncoplanar beam arrangements and, to a larger extent, increasing the number of treatment beams further improved plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

FusionArc optimization: A hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy

Purpose: To introduce a hybrid volumetric modulated arc therapy/intensity modulated radiation therapy (VMAT/IMRT) optimization strategy called FusionArc that combines the delivery efficiency of single-arc VMAT with the potentially desirable intensity modulation possible with IMRT.Methods: A beamlet-based inverse planning system was enhanced to combine the advantages of VMAT and IMRT into one comprehensive technique. In the hybrid strategy, baseline single-arc VMAT plans are optimized and then the current cost function gradients with respect to the beamlets are used to define a metric for predicting which beam angles would benefit from further intensity modulation. Beams with the highest metric values (called the gradient factor) are converted from VMAT apertures to IMRT fluence, and the optimization proceeds with the mixed variable set until convergence or until additional beams are selected for conversion. One phantom and two clinical cases were used to validate the gradient factor and characterize the FusionArc strategy. Comparisons were made between standard IMRT, single-arc VMAT, and FusionArc plans with one to five IMRT/hybrid beams.Results: The gradient factor was found to be highly predictive of the VMAT angles that would benefit plan quality the most from beam modulation. Over the three cases studied, a FusionArc plan with three converted beams achieved superior dosimetric quality with reductions in final cost ranging from 26.4% to 48.1% compared to single-arc VMAT. Additionally, the three beam FusionArc plans required 22.4%-43.7% fewer MU/Gy than a seven beam IMRT plan. While the FusionArc plans with five converted beams offer larger reductions in final cost-32.9%-55.2% compared to single-arc VMAT-the decrease in MU/Gy compared to IMRT was noticeably smaller at 12.2%-18.5%, when compared to IMRT.Conclusions: A hybrid VMAT/IMRT strategy was implemented to find a high quality compromise between gantry-angle and intensity-based degrees of freedom. This optimization method will allow patients to be simultaneously planned for dosimetric quality and delivery efficiency without switching between delivery techniques. Example phantom and clinical cases suggest that the conversion of only three VMAT segments to modulated beams may result in a good combination of quality and efficiency.

61 RADIATION PROTECTION AND DOSIMETRY↗

Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements

Purpose: Four-dimensional computed tomography (4DCT) can be used to make measurements of pulmonary function longitudinally. The sensitivity of such measurements to identify change depends on measurement uncertainty. Previously, intrasubject reproducibility of Jacobian-based measures of lung tissue expansion was studied in two repeat prior-RT 4DCT human acquisitions. Difference in respiratory effort such as breathing amplitude and frequency may affect longitudinal function assessment. In this study, the authors present normalization schemes that correct ventilation images for variations in respiratory effort and assess the reproducibility improvement after effort correction.Methods: Repeat 4DCT image data acquired within a short time interval from 24 patients prior to radiation therapy (RT) were used for this analysis. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. In addition to computing the ventilation maps from end expiration to end inspiration, the authors investigated the effort normalization strategies using other intermediated inspiration phases upon the principles of equivalent tidal volume (ETV) and equivalent lung volume (ELV). Scatter plots and mean square error of the repeat ventilation maps and the Jacobian ratio map were generated for four conditions: no effort correction, global normalization, ETV, and ELV. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2 mm distance-to-agreement and 5% ventilation difference.Results: The pattern of regional pulmonary ventilation changes as lung volume changes. All effort correction strategies improved reproducibility when changes in respiratory effort were greater than 150 cc (p < 0.005 with regard to the gamma pass rate). Improvement of reproducibility was correlated with respiratory effort difference (R = 0.744 for ELV in the cohort with tidal volume difference greater than 100 cc). In general for all subjects, global normalization, ETV and ELV significantly improved reproducibility compared to no effort correction (p = 0.009, 0.002, 0.005 respectively). When tidal volume difference was small (less than 100 cc), none of the three effort correction strategies improved reproducibility significantly (p = 0.52, 0.46, 0.46 respectively). For the cohort (N = 13) with tidal volume difference greater than 100 cc, the average gamma pass rate improves from 57.3% before correction to 66.3% after global normalization, and 76.3% after ELV. ELV was found to be significantly better than global normalization (p = 0.04 for all subjects, and p = 0.003 for the cohort with tidal volume difference greater than 100 cc).Conclusions: All effort correction strategies improve the reproducibility of the authors' pulmonary ventilation measures, and the improvement of reproducibility is highly correlated with the changes in respiratory effort. ELV gives better results as effort difference increase, followed by ETV, then global. However, based on the spatial and temporal heterogeneity in the lung expansion rate, a single scaling factor (e.g., global normalization) appears to be less accurate to correct the ventilation map when changes in respiratory effort are large.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-18A-01: Radiation Dose Reducing Strategies in CT, Fluoroscopy and Radiography

Advances in medical x-ray imaging have provided significant benefits to patient care. According to NCRP 160, there are more than 400 million x-ray procedures performed annually in the United States alone that contributes to nearly half of all the radiation exposure to the US population. Similar growth trends in medical x-ray imaging are observed worldwide. Apparent increase in number of medical x-ray imaging procedures, new protocols and the associated radiation dose and risk has drawn considerable attention. This has led to a number of technological innovations such as tube current modulation, iterative reconstruction algorithms, dose alerts, dose displays, flat panel digital detectors, high efficient digital detectors, storage phosphor radiography, variable filters, etc. that are enabling users to acquire medical x-ray images at a much lower radiation dose. Along with these, there are number of radiation dose optimization strategies that users can adapt to effectively lower radiation dose in medical x-ray procedures. The main objectives of this SAM course are to provide information and how to implement the various radiation dose optimization strategies in CT, Fluoroscopy and Radiography. Learning Objectives: To update impact of technological advances on dose optimization in medical imaging. To identify radiation optimization strategies in computed tomography. To describe strategies for configuring fluoroscopic equipment that yields optimal images at reasonable radiation dose. To assess ways to configure digital radiography systems and recommend ways to improve image quality at optimal dose.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-02: Comparison of Two RapidArc Delivery Strategies in Stereotactic Body Radiotherapy of Stage I and II Peripheral Lung Tumors with Unflattened Beams

Purpose: The full arcs strategy used in SBRT with RapidArc and unflattened (FFF) beams in large and heterogeneous peripheral non-smallcell lung cancer (NSCLC) appears to be suboptimal as it increases the disadvantageous dose to the contralateral lung, which potentially increases the toxicity to surrounding tissues. In this study, we investigated, for the first time, the dose delivery strategies using partial arcs (PA) and the fully rotational arcs with avoidance sectors (FAAS) for SBRT with FFF beams in peripheral NSCLC patients. Methods: Eighteen patients with NSCLC (stage I and II) were selected for this study. Nine patients with a GTV <= 10cc were designated as the small tumor group. The remaining nine patients with a GTV between 10 cc and 44 cc were assigned to the large tumor group. The treatment plans were generated in eighteen patients using PA and FAAS, respectively, and delivered with a Varian TrueBeam Linac. Dosimetry of the target and organs at risk (OAR), total MU, out-of-field dose, and delivery time were analyzed. Delta4 and Portal dosimetry were employed to evaluate the delivery accuracy. Results: or the small tumor group, the FAAS plans significantly achieved a better conformity index, the lower total MU and out-of-field dose, a shorter treatment time, and the reduced doses to cord, heart, and lung (p < 0.05). But the target doses were slightly higher than that delivered by PA plans. For the large tumor group, the PA plans significantly attained a better conformity index and a shorter treatment time (p < 0.05). Furthermore, all plans achieved a high pass rate, with all the gamma indices greater than 97% at the Γ{sub 3mm,} {sub 3%} threshold. Conclusion: This study suggests that FAAS strategy is more beneficial for small tumor patients undergoing lung SBRT with FFF beams. However, for large tumor patients, PA strategy is recommended. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

60 APPLIED LIFE SCIENCES↗

Statistical-learning strategies generate only modestly performing predictive models for urinary symptoms following external beam radiotherapy of the prostate: A comparison of conventional and machine-learning methods

Purpose: Given the paucity of available data concerning radiotherapy-induced urinary toxicity, it is important to ensure derivation of the most robust models with superior predictive performance. This work explores multiple statistical-learning strategies for prediction of urinary symptoms following external beam radiotherapy of the prostate. Methods: The performance of logistic regression, elastic-net, support-vector machine, random forest, neural network, and multivariate adaptive regression splines (MARS) to predict urinary symptoms was analyzed using data from 754 participants accrued by TROG03.04-RADAR. Predictive features included dose-surface data, comorbidities, and medication-intake. Four symptoms were analyzed: dysuria, haematuria, incontinence, and frequency, each with three definitions (grade ≥ 1, grade ≥ 2 and longitudinal) with event rate between 2.3% and 76.1%. Repeated cross-validations producing matched models were implemented. A synthetic minority oversampling technique was utilized in endpoints with rare events. Parameter optimization was performed on the training data. Area under the receiver operating characteristic curve (AUROC) was used to compare performance using sample size to detect differences of ≥0.05 at the 95% confidence level. Results: Logistic regression, elastic-net, random forest, MARS, and support-vector machine were the highest-performing statistical-learning strategies in 3, 3, 3, 2, and 1 endpoints, respectively. Logistic regression, MARS, elastic-net, random forest, neural network, and support-vector machine were the best, or were not significantly worse than the best, in 7, 7, 5, 5, 3, and 1 endpoints. The best-performing statistical model was for dysuria grade ≥ 1 with AUROC ± standard deviation of 0.649 ± 0.074 using MARS. For longitudinal frequency and dysuria grade ≥ 1, all strategies produced AUROC>0.6 while all haematuria endpoints and longitudinal incontinence models produced AUROC<0.6. Conclusions: Logistic regression and MARS were most likely to be the best-performing strategy for the prediction of urinary symptoms with elastic-net and random forest producing competitive results. The predictive power of the models was modest and endpoint-dependent. New features, including spatial dose maps, may be necessary to achieve better models.

60 APPLIED LIFE SCIENCES↗

WE-E-BRB-01: Personalized Motion Management Strategies for Pencil Beam Scanning Proton Therapy

Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed. Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian.; H. Li, Na.

60 APPLIED LIFE SCIENCES↗

Combination Attenuation Offers Strategy for Live Attenuated Coronavirus Vaccines

With an ongoing threat posed by circulating zoonotic strains, new strategies are required to prepare for the next emergent coronavirus (CoV). Previously, groups had targeted conserved coronavirus proteins as a strategy to generate live attenuated vaccine strains against current and future CoVs. With this in mind, we explored whether manipulation of CoV NSP16, a conserved 2'O methyltransferase (MTase), could provide a broad attenuation platform against future emergent strains. Using the severe acute respiratory syndrome-CoV mouse model, an NSP16 mutant vaccine was evaluated for protection from heterologous challenge, efficacy in the aging host, and potential for reversion to pathogenesis. Despite some success, concerns for virulence in the aged and potential for reversion makes targeting NSP16 alone an untenable approach. However, combining a 2'O MTase mutation with a previously described CoV fidelity mutant produced a vaccine strain capable of protection from heterologous virus challenge, efficacy in aged mice, and no evidence for reversion. Together, the results indicate that targeting the CoV 2'O MTase in parallel with other conserved attenuating mutations may provide a platform strategy for rapidly generating live attenuated coronavirus vaccines. IMPORTANCE Emergent coronaviruses remain a significant threat to global public health and rapid response vaccine platforms are needed to stem future outbreaks. However, failure of many previous CoV vaccine formulations has clearly highlighted the need to test efficacy under different conditions and especially in vulnerable populations such as the aged and immunocompromised. This study illustrates that despite success in young models, the 2'O methyltransferase mutant carries too much risk for pathogenesis and reversion in vulnerable models to be used as a stand-alone vaccine strategy. Importantly, the 2'O methyltransferase mutation can be paired with other attenuating approaches to provide robust protection from heterologous challenge and in vulnerable populations. Coupled with increased safety and reduced pathogenesis, the study highlights the potential for 2'O methyltransferase attenuation as a major component of future live attenuated coronavirus vaccines.

Evolview, evolgenius, SARS-CoV, NSP14 exonuclease↗

Promoting Sustainable Transportation Modes: A Systematic Review of Behavior-Change Strategies

In previous studies, many travel-behavior-change strategies often relied on single behavior determinants or psychological theories, overlooking the incorporation of sociopsychological theories for guidance in their design. Integrating these theories could offer consistent guidance for program developers and enhance intervention effectiveness. This paper systematically reviews interventions targeting travel-behavior change, with a focus on self-determination theory and its principles of satisfying individuals’ competence, autonomy, and relatedness needs for enacting change. Additionally, experiment design methods, including randomized controlled trials and quasi-experimental designs, are reviewed and discussed. Key findings highlight the effectiveness of personalized interventions and integrating feedback with goal-setting strategies. Given the limited direct references to sociopsychological theories in existing studies, we explore relevant sociopsychological theories applicable to travel-behavior-change programs to provide examples of how strategies could be designed based on them. This review contributes valuable insights into the development of strategies for changing travel behavior, offering a theoretical framework for researchers and practitioners to guide intervention design, experimentation, and evaluation. In conclusion, leveraging these theories not only facilitates reproducibility but also provides a standardized approach for transportation demand management program developers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studsvik R2 materials test reactor Ad Hoc depletion strategy for the derivation of the fuel isotopic composition of the MPCMIV benchmark

The Ad Hoc Depletion Strategy elaborated by the NINE company, developed in support of the organization of the MPCMIV (Multi-physics Pellet Cladding Mechanical Interaction Validation) benchmark input and output specifications, is presented. This work aims at illustrating the strategy itself and then showing the results obtained with its application over the Studsvik R2 Testing Reactor, which is analyzed in the benchmark. The objective of the application of the strategy is to compute the fuel elements isotopic compositions at the beginning of some core loadings of interest for the benchmark. To this objective, it is necessary to implement first the simulation model of the three single assembly types and perform the infinite lattice depletions, then, to build the full core model and to perform the simulation of the core cycle. All the models and simulations were carried out with the use of the Monte Carlo particle transport code Serpent 2. Finally, the simulations results are assessed against Studsvik isotopic compositions of the fuel elements discharged from the R2 Reactor at the end of the core loading. Several assumptions were necessary during all the steps of the strategy, to overcome the lack of information regarding the core management. For this reason, the solution found at the end of the current analysis may not be completely optimized and further improvements regarding the model assumptions will be tested in a future work. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗