Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shape optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Evaluating pulse-shaping capabilities of next-generation pulsed power architectures

This project evaluated the pulse shaping capabilities of next-generation pulsed power (NGPP) architectures. NGPP architectures share several common attributes including multiple independent pulse-generation lines, a radial water-insulated impedance transformer, and a central vacuum insulated load region. A multi-module circuit model was developed, incorporating independent pulse-generation lines and a 2-D transmission line mesh of the radial impedance transformer to assess the effects of azimuthal asymmetry in pulse-shaped experiments. Circuit model simulations demonstrated that NGPP architectures are able to produce the the desired current pulse shapes for exemplar NGPP experiments. Additionally, the project explored automated methods for experiment design, including derivative -ree optimization and machine learning. Pulse-shaped experiments require designers to determine machine parameters that reliably produce the desired current pulse at the load, a process that typically relies on expert knowledge and iterative adjustments using the Z circuit model. Given the increased complexity of NGPP systems, this manual approach may be impractical. While the evaluated methods do not eliminate the need for manual iteration, they can reduce the time required for experiment design. Derivative-free optimization automates much of the trial-and-error process, providing a close starting point for manual adjustments or making small modifications to near-final designs. Meanwhile, deep neural network methods can generate a good qualitative match to the desired current pulse in under one second without requiring circuit model simulations.

42 ENGINEERING↗

Soliton molecules: Experiments and optimization

Stable compound states of several fiber-optic solitons have recently been demonstrated. In the first experiment their shape was approximated, for want of a better description, by a sum of Gaussians. Here we discuss an optimization strategy which helps to find preferable shapes so that the generation of radiative background is reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of a Fast Neutron Scintillator for Real-Time Pulse Shape Discrimination in the Transient Reactor Test Facility (TREAT) Hodoscope

We present a multi-channel, fast neutron/gamma ray detector array system that utilizes ZnS(Ag) scintillator detectors. The system employs field programmable gate arrays (FPGAs) to do real-time all digital neutron/gamma ray discrimination with pulse height and time histograms to allow count rates in excess of 1,000,000 pulses per second per channel. The system detector number is scalable in blocks of 16 channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of cathode shape on vertical buffered electropolishing for niobium SRF cavities

This paper reports the research results of the effect of cathode shape during vertical buffered electropolishing (BEP) by employing a demountable single cell niobium (Nb) superconducting radio frequency (SRF) cavity. Several different cathode shapes such as, for instance, bar, ball, ellipsoid, and wheels of different diameters have been tested. Detailed electropolishing parameters including I–V characteristic, removal rate, surface roughness, and polishing uniformity at different locations inside the demountable cavity are measured. Similar studies are also done on conventional electropolishing (EP) for comparison. It is revealed that cathode shape has dominant effects for BEP especially on the obtaining of a suitable polishing condition and a uniform polishing rate in an Nb SRF single cell cavity. EP appears to have the same tendency. This paper demonstrates that a more homogeneous polishing result can be obtained by optimizing the electric field distribution inside the cavity through the modification of the cathode shape given the conditions that temperature and electrolyte flow are kept constant. Electric field distribution and electrolyte flow patterns inside the cavity are simulated via Poisson–Superfish and Solidworks respectively. Finally, with the optimal cathode shape, BEP shows a much faster polishing rate of ~2.5 μm/min and is able to produce a smoother surface finish in the treatments of single cell cavities in comparison with EP.

36 MATERIALS SCIENCE↗

Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques

Purpose: The goal of this study is to determine a method for Monte Carlo (MC) characterization of the miniature electronic brachytherapy x-ray sources (MEBXS) and to set dosimetric parameters according to TG-43U1 formalism. TG-43U1 parameters were used to get optimal designs of MEBXS. Parameters that affect the dose distribution such as anode shapes, target thickness, target angles, and electron beam source characteristics were evaluated. Optimized MEBXS designs were obtained and used to determine radial dose functions and 2D anisotropy functions in the electron energy range of 25-80 keV. Methods: Tungsten anode material was considered in two different geometries, hemispherical and conical-hemisphere. These configurations were analyzed by the 4C MC code with several different optimization techniques. The first optimization compared target thickness layers versus electron energy. These optimized thicknesses were compared with published results by Ihsan et al.[Nucl. Instrum. Methods Phys. Res. B 264, 371-377 (2007)]. The second optimization evaluated electron source characteristics by changing the cathode shapes and electron energies. Electron sources studied included; (1) point sources, (2) uniform cylinders, and (3) nonuniform cylindrical shell geometries. The third optimization was used to assess the apex angle of the conical-hemisphere target. The goal of these optimizations was to produce 2D-dose anisotropy functions closer to unity. An overall optimized MEBXS was developed from this analysis. The results obtained from this model were compared to known characteristics of HDR {sup 125}I, LDR {sup 103}Pd, and Xoft Axxent electronic brachytherapy source (XAEBS) [Med. Phys. 33, 4020-4032 (2006)]. Results: The optimized anode thicknesses as a function of electron energy is fitted by the linear equation Y ({mu}m) = 0.0459X (keV)-0.7342. The optimized electron source geometry is obtained for a disk-shaped parallel beam (uniform cylinder) with 0.9 mm radius. The TG-43 distribution is less sensitive to the shape of the conical-hemisphere anode than the hemispherical anode. However, the optimized apex angle of conical-hemisphere anode was determined to be 60 deg. For the hemispherical targets, calculated radial dose function values at a distance of 5 cm were 0.137, 0.191, 0.247, and 0.331 for 40, 50, 60, and 80 keV electrons, respectively. These values for the conical-hemisphere targets are 0.165, 0.239, 0.305, and 0.412, respectively. Calculated 2D anisotropy functions values for the hemispherical target shape were F(1 cm, 0 deg.) = 1.438 and F(1 cm, 0 deg.) = 1.465 for 30 and 80 keV electrons, respectively. The corresponding values for conical-hemisphere targets are 1.091 and 1.241, respectively. Conclusions: A method for the characterizations of MEBXS using TG-43U1 dosimetric data using the MC MCNP4C has been presented. The effects of target geometry, thicknesses, and electron source geometry have been investigated. The final choices of MEBXS design are conical-hemisphere target shapes having an apex angle of 60 deg. Tungsten material having an optimized thickness versus electron energy and a 0.9 mm radius of uniform cylinder as a cathode produces optimal electron source characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-throughput homogenization of a quasi-Gaussian ultrafast laser beam using a combined refractive beam shaper and spatial light modulator

Efficiently shaping femtosecond, transverse Gaussian laser beams to flat-top beams with flat wavefronts is critical for large-scale material processing and manufacturing. Existing beam shaping devices fall short either in final beam homogeneity or efficiency. Here, we present an approach that uses refractive optics to perform the majority of the beam shaping and then uses a fine-tune device (spatial light modulator) to refine the intensity profile. For the beam that we selected, circularly asymmetric with intensity fluctuations, our method achieved a uniformity of 0.055 within 90% of the beam area at 92% efficiency. The optimization involved an iterative beam shaping process that converged to optimum within 10 iterations.

43 PARTICLE ACCELERATORS↗

SU-F-T-505: A Novel Approach for Sparing Critical Organs at Risk for Cancer Patients Undergoing Radiation Oncology Treatments

Purpose: A major goal of an effective radiation treatment plan is to deliver the maximum dose to the tumor while minimizing radiation exposure to the surrounding normal structures. For example, due to the radiation exposure to neighboring critical structures during prostate cancer treatment, a significant increase in cancer risk was observed for the bladder (77%) and the rectum (105%) over the following decade. Consequently, an effective treatment plan necessitates limiting the exposure to such organs which can best be achieved by physically displacing the organ at-risk. The goal of this study is to present a prototype for an organ re-positioner device designed and fabricated to physically move the rectum away from the path of radiation beam during external beam and brachytherapy treatments. This device affords patient comfort and provides a fully controlled motion to safely relocate the rectum during treatment. Methods: The NiTi shape memory alloy was designed and optimized for manufacturing a rectal re-positioner device through cooling and heating the core alloy for its shaping. This has been achieved through a prototyped custom designed electronic circuit in order to induce the reversible austenitic transformation and was tested rigorously to ensure the integrity of the actuated motion in displacement of the target anatomy. Results: The desirable NiTi shape-setting was configured for easy insertion and based on anatomical constraint. When the final prototype was evaluated, accuracy and precision of the maximum displacement and temperature changes revealed that the device could safely be used within the target anatomy. Conclusion: The organ re-positioner device is a promising tool that can be implemented in clinical setting. It provides a controlled and safe displacement of the delicate organ(s) at risk. The location of the organ being treated could also be identified using conventional onboard imaging devices or MV imaging available on-board most modern clinical accelerators.

60 APPLIED LIFE SCIENCES↗

Optimization of wind plant layouts using an adjoint approach

Abstract. Using adjoint optimization and three-dimensional steady-state Reynolds-averaged Navier–Stokes (RANS) simulations, we present a new gradient-based approach for optimally siting wind turbines within utility-scale wind plants. By solving the adjoint equations of the flow model, the gradients needed for optimization are found at a cost that is independent of the number of control variables, thereby permitting optimization of large wind plants with many turbine locations. Moreover, compared to the common approach of superimposing prescribed wake deficits onto linearized flow models, the computational efficiency of the adjoint approach allows the use of higher-fidelity RANS flow models which can capture nonlinear turbulent flow physics within a wind plant. The steady-state RANS flow model is implemented in the Python finite-element package FEniCS and the derivation and solution of the discrete adjoint equations are automated within the dolfin-adjoint framework. Gradient-based optimization of wind turbine locations is demonstrated for idealized test cases that reveal new optimization heuristics such as rotational symmetry, local speedups, and nonlinear wake curvature effects. Layout optimization is also demonstrated on more complex wind rose shapes, including a full annual energy production (AEP) layout optimization over 36 inflow directions and 5 wind speed bins.

17 WIND ENERGY↗

BISON fuel performance modeling optimization for experiment X447 and X447A using axial swelling and cladding strain measurements

With the recent need to qualify new reactor designs such as the Versatile Test Reactor (VTR), fuel performance calculations need to be performed to determine safety criteria of the proposed designs. In order to validate the fuel performance results obtained by a fuel performance code, BISON, for new reactor designs, legacy fuel from EBR-II and FFTF MFF with Post -Irradiation Examination (PIE) data need to be used as validation cases to benchmark models. Here in this work, BISON has been paired with the Fuels Irradiation & Physics Database (FIPD) and IFR Materials Information System (IMIS) to supply PIE data for comparison with simulations of EBR-II experiments X447/X447A. X447/X447A were assessed by implementing models for Fuel Cladding Chemical Interaction (FCCI) within BISON and optimizing the friction coefficient between the fuel surface and the cladding, the anisotropic swelling factor, and the HT9 first thermal creep scalar (which scales the first term in the HT9 creep equation) to best match the PIE axial fuel swelling height and cladding profilometry for all pins in X447/X447A. The optimal values were found using a generic algorithm developed to select different values for the three parameters until end criteria was met and error couldn’t be reduced further. The BISON-simulated cladding profilometry was evaluated using Standard Error of the Estimate (SEE) to account for the profile shape of the cladding profilometry. Optimal values for the friction coefficient, anisotropic fuel swelling factor, and HT9 first thermal creep scalar were found to best fit the BISON simulation results to the PIE measurements found in IMIS and FIPD. Improvements to current models are suggested to account for the underprediction of fuel swelling at low burnups and the overprediction of fuel swelling at higher burnups observed for the axial fuel swelling height. Although two pins in EBR-II X447/X447A (DP70 and DP75) were known to fail due to FCCI, none of the pins simulated in BISON reached a cumulative damage fraction (CDF) above 0.008 with FCCI correlations coupled in the BISON simulations. The error estimate generated for all pins in X447/X447A using optimal values was 209 µm, which is deemed acceptable.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Carbon fiber design improvements based on economic models

Circular fiber geometries are predominant in commercial carbon fiber material systems, but the use of this fiber shape has numerous limitations. Circular geometries have continuous symmetry, which is helpful for various processing considerations, but also have the largest possible maximum diffusion thickness for a given fiber area. This characteristic means that circular carbon fibers always have the highest material processing cost and lowest production throughput compared to any other fiber shape with the same area and tow count. To quantify material cost and other benefits for non-circular carbon fiber geometries, process models for polyacrylonitrile based carbon fiber production are developed in relationship to the carbon fiber shape, size, and tow count. For a given fiber shape, precursor production costs are shown to favor maximizing fiber size while conversion costs are minimized by the smallest fiber size. These competing cost trends result in a numerically optimal fiber size for a given shape and tow count, while both cost components are decreased by increasing tow count. Cost–performance tradeoffs for three lobe fiber geometries are studied by supplementing the cost trends with a numerical failure model to predict compressive strength for discrete shape variants. The shape selection is shown to be more sensitive to variations in cost than compressive strength while suboptimal shape designs can improve manufacturing robustness and achievable fiber volume fractions. Finally, an optimal three lobe carbon fiber is identified that balances the set of considerations while reducing costs and embodied energy and increasing production throughput compared to a commercial carbon fiber.

Carbon fiber↗

Complex shaped boron carbides from negative additive manufacturing

In this paper, complex shaped boron carbide with carbon (B 4 C/C) at near-full densities were achieved for the first time using negative additive manufacturing techniques via gelcasting. Negative additive manufacturing involves 3D printing of sacrificial molds used for casting negative copies. B 4 C powder distributions and rheology of suspensions were optimized to successfully cast complex shapes. In addition to demonstrating scalability of these complex geometries, hierarchically meso-porous structures were also shown to be possible from this technique. Resorcinol-Formaldehyde (RF) polymer was selected as the gelling agent and can also pyrolyze into a carbon aerogel network to act as the sintering aid for B 4 C. Finally, due to the highly effective distribution of in situ carbon for the B 4 C matrix, near-full sintered density of 97–98% of theoretical maximum density was achieved.

36 MATERIALS SCIENCE↗

Top-down design of protein architectures with reinforcement learning

As a result of evolutionary selection, the subunits of naturally occurring protein assemblies often fit together with substantial shape complementarity to generate architectures optimal for function in a manner not achievable by current design approaches. We describe a “top-down” reinforcement learning–based design approach that solves this problem using Monte Carlo tree search to sample protein conformers in the context of an overall architecture and specified functional constraints. Cryo–electron microscopy structures of the designed disk-shaped nanopores and ultracompact icosahedra are very close to the computational models. The icosohedra enable very-high-density display of immunogens and signaling molecules, which potentiates vaccine response and angiogenesis induction. Our approach enables the top-down design of complex protein nanomaterials with desired system properties and demonstrates the power of reinforcement learning in protein design.

Science & Technology - Other Topics↗

New natural shapes of non-Gaussianity from high-derivative interactions and their optimal limits from WMAP 9-year data

Given the fantastic experimental effort, it is important to thoroughly explore the signature space of inflationary models. The fact that higher derivative operators do not renormalize lower derivative ones allows us to find a large class of technically natural single-clock inflationary models where, in the context of the Effective Field Theory of Inflation, the leading interactions have many derivatives. We systematically explore the 3-point function induced by these models and their overlap with the standard equilateral and orthogonal templates. We find that in order to satisfactorily cover the signature space of these models, two new additional templates need to be included. We then perform the optimal analysis of the WMAP 9-year data for the resulting four templates, finding that the overall significance of a non-zero signal is between 2–2.5σ, depending on the choice of parameter space, partially driven by the preference for nonzero f{sub NL}{sup orth} in WMAP9.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An energy-optimization method to study gel-swelling in confinement

Using our open-source programming environment Morpho, an energy-optimization method is developed to compute equilibrium shapes of an arbitrarily confined swollen hydrogel. The internal strains and contact forces are measured, probing its mechanics.

Joshi, Chaitanya↗